Boeing 737-924ER
Service difficulty reports · 3,682
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025110410882Skin · crackedCRACK FOUND AT RIGHT HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 120.30, 26" FROM FRONT SPAR, I/B ROW. CRACK LENGTH:1" REF. AAR N/R:99951969 INSTALLED NEW REPAIR DOUBLER ON RT HORIZONTAL STABILIZER LOWER SKIN AND 2EA REPAIR FILLERS AT STAB STA 120.30 PER SRM SDR CALA2025100809794Web · corrodedFWD PIT DOOR CUTOUT, LOWER SILL CORRODED ON UPPER SURFACE. CORROSION FOUND TO BE 100% OUT OF LIMITS. REMOVED AND REPLACED LOWER MAIN SILL WEB PN 143A8122- 10 IAW BOEING DWG 143A8122 AND SRM 51-40-02-0G-0.SDR CALA2025100809787Unknown · odorDIRTY SOCK SMELL CAME BACK ON CLIMB WENT AWAY IN CRUISE STRONG O N APPROACH. PROCEEDED TO RUN AIR CONDITIONING SYSTEM ON AIRCRAFT FOR FURTHER TROUBLESHOOTING PER AMM TASK 05-51-26-800-801-C1 (SUBTASK 05-51-26-200-001-C10). NO FOUL SMELL WAS NOTED. AIRCRAFT OKSDR CALA2025100709724Engine · odorDIRTY SOCK SMELL AT TAKEOFF POWER WENT AWAY CRUISE CAME BACK ON IDLE DESCENT NOTED DISCREPANCY ORDOR COCKPIT/FWD. CABIN . NOTED PREVIOUS STATION OVERNIGHT WORK #1 ENGINE WASH. SUSPECT RESIDUAL CONTAMINATION. PERFORM CONTAMINATION REMOVAL #1 AND #2 ENGINES AND SDR CALA2025100709723Unknown · vaporCHEMICAL FUME ODOR AND VISIBLE VAPOR IN WHEEL WELL TUNED ON PACKS AND HYD SYSTEM, UNABLE TO DUPLICATE. NO EVIDENCE OF VAPOR OR ODOR NOTED. REF AMM 05-51-00SDR CALA2025100709722Retainer · looseWHEN FA SHOWED UP DOOR 2L WAS PARTIALLY ARMED AND THE DOOR MIGHT HAVE BEEN OPENED FA FOUND 1/2 OF THE GIRT BAR FALLEN OFF OF RETAINER AND LYING ON THE FLOOR. INSPECTED SLIDE AND GIRT BAR RETAINER. ALL CKS OKAY REF AMM 25-66-01...SUSPECT BAR LOOSELY INSTALLED ISDR CALA2025100709741Transition Panel · corrodedFWD PIT, R/H TRANSITION PANEL CORRODED ON UPPER SURFACE FROM BS 492 TO BS 500A APPROX. RBL- 24. BLENDED AND REMOVED CORROSION IN SEVERAL AREAS 100% MATERIAL LOSS FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED DAMAGE TRANSITION PNL FROM FWD CARGO COMPARTSDR CALA2025100709740Floor Support · corrodedAFT CARGO COMPARTMENT DOOR CUTOUT LOWER SILL HAS CORROSION AT MULTIPLE PLACES. AFT CARGO COMPARTMENT DOOR CUTOUT LOWER SILL WEB FOUND TO BE OUT OF LIMITS IAW 737-800ER SRM 53-30-15-1A-1 FIG 103 REMOVED AND REPLACED WEB PART #146A8123U25 ATSMRO PO # 1133565 ISDR CALA2025100609608A/C Pack · odorSTRONG SMELL AFTER PACK TRANSFER FROM ENG TO APU AFTER LDG IMAGE OF SMOKE/ODOR IN THE PLANE QUESTIONAIRE ACCOMPLISHED TASK 05-51-26-800-801 INITIAL INSPECTION WITH NO FINDINGS. NO FURTHER ACTION REQUIRED AIRCRAFT IS OK FOR SERVICE.SDR CALA2025103010756Skin · damagedAFTER FURTHER EVALUATION, LIGHTNING STRIKE FOUND TO BE OUT LIMI TS REQUIRE REPAIR ON FUSELAGE SKIN BTW STA 380 TO STA 400 AND S- -5R TO S-6R. PERFORMED REPAIR ON FUSELAGE SKIN BTW STA 380 TO STA 400 AND S- -5R TO S-6R IAW SRM 53-00-01-2R-3, THIS REPAIR IS A SDR CALA2025100909837Baffle · corrodedFWD CARGO BAY, STRINGER 26L BETWEEN BS 500F - 500G BAFFLE IS CORRODED ON UPPER FLANGE. AFTER INVESTIGATION, DAMAGED AREA AT WAS CONCLUDED THAT THE MATERIAL IS FOUND TO BE 100% OUT OF LIMITS DUE TO EVIDENT EXPOLATION IAW SRM 53-00-53-1A-2, FIG 103. LOCATEDSDR CALA2025100809792Attach Angle · crackedFOUND CRACK LOWER FUSELAGE REAR SPAR LEFT VAPOR BARRIER UPPER ATTACHED ANGLE LBL 7, BS 663.75. INSTALLED REPAIR AT BS 663 LT VAPOR BARRIER ANGLE FROM LBL 5 TO LBL 30 PER SRM 57-10-10-2R-5.SDR CALA2025100809791Angle · corrodedFWD PIT, LEFT SUPPORT ASSY CORRODED AT LOWER AREA AT BS 500L APPROX. AT LBL-24. REMOVED SUPPORT ASSY (ANGLE) IAW SRM 51-40-02 AND REMOVAL DAMAGE CORROSION. MAT. REMAINED .037" FOUND WITHOUT LIMITS OF .056". LOCATED & DRILLED 1EA NEW SUPPORT ASSY (ANGLE) IASDR CALA2025100709735Floor Support · corrodedMAIN CABIN FLOOR SUPPORT INTERCOSTAL FLOOR BOARD FASTENER HOLES 2EA HAVE CORROSION IN THE BORE BETWEEN STA 294.5 AND 312 AT APPROX LBL12. MAIN CABIN FLOOR STA 294.5 - 312 LBL 11.1 BLENDED AFFECTED AREA ON INTERCOSTAL TO REMOVED CORROSION, REMAINING MATERIALSDR CALA2025100709734Attach Angle · crackedFOUND CRACK LOWER FUSELAGE REAR SPAR RT VAPOR BARRIER UPPER ATTACH ANGLE RBL 7 STA 663.75. INSTALLED REPAIR AT STA 663 RH VAPOR BARRIER ANGLE FROM RBL 5 TO RBL 30 PER SRM 57-10-10-2R-5. ACCOMPLISHED REPAIR AT STA 663 LH VAPOR BARRIER ANGLE FROM LBL 5 TO LBSDR CALA2025100709733Floor Panel · puncturedFWD CARGO PIT FLOOR PANEL 120CF HAS TWO PUNCTURES. IAW SRM 53-30-53. FABRICATED NEW FWD CARGO FLOOR PANEL 120CF IAW EC/RA 5320-02744 REV A. PRIMED AND ALODINED FLOOR PANEL IAW SRM 51-20-01.SDR CALA2025100609656Filter · dirtyVERY MUSTY SMELL COMING FROM AIR VENTS TOMC LOCKED LP. PLEASE PERFORM CONDITIONAL INSP PER AMM 05-51-26-800-801-C1. PERFORM AC PACK BURN OUT AND REPLACE RECIRC FILTERS. REVIEWED WORK HISTORY AND FOUND #1 ENG WASH WAS JUST COMPLETED IN RDU LAST NIGHT DURING SDR CALA2025100609607Smoke Detector · false activationLAVATORY E SMOKE ALARM SOUNDING AT GATE. NO SMOKE OR FUMES OBSERVED. CONFIRMED WITH FLIGHT CREW NO PRESENCE OF SMOKE. PERFORMED OPSCHECK OF LAV E SMOKE DECET. OPS CHECK GOOD AT THIS TIME. OK TO CONTINUE AT THIS TIMESDR CALA2025100609606None · odorSTRONG GASOLINE ODOR IN FRONT OF AIRCRAFT AND COCKPIT FAINT SMELL AFT OF THE AIRCRAFT THERE WAS A GASOLINE POWERED AIR CART ATTACHED TO THE AIRCRAFT. THE AIR FROM THE CART DOES NOT HAVE ANY GASOLINE ODOR. CART REMOVED FROM THE AIRCRAFT AND APU IS BEING USED TOSDR CALA2025100709750Power Supply · inoperativeCABIN SEAT EMERGENCY LIGHTS INOP FROM 22ABC TO 27ABC. REPLACED FUSE NUMBER 2 ON EMERGENCY BATTERY PACK CHARGER M1670 IAW AMM 33-51-06-960-804.PERFORMED EMERGENCY LIGHTS OPERATIONAL CHECK IAW AMM 33-51-00-720-801. OPS CHECK GOO D.SDR CALA2025102610518Web · corrodedMAIN CABIN L/H SIDE CREASE BEAM WEB IS CORRODED ON THE UPPER SURFACE AT THE MID EXIT DOOR PLUG FWD LOWER BONDING WIRE CONTACT POINT. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS. ORIG MAT .063,MAT LOSS .014, REMAINING MAT .049 IAW SRM 51-10-02.SDR CALA2025101610167Frame · damagedEA2500-13122 OPS 011 F.S 727K TO 727L RT SIDE STRINGER 5R WAP#3 & GROUND CLIP INTERFERES WITH THE INTERCOSTAL INSTALLATION REQUESTING ENGINEERING ASSISTANCE. SUPPORT TASK NSA EMX NR 00224 ESFR CREATED FOR INT DURING CXF MOD. RELOCATED GROUND CLIP AND WAP #3 FRSDR CALA2025100609666Seal · missingLEFT WING I/B FLAP LOWER O/B SEAL MISSING. UPATED PICTURE. INSTALLED LEFT WING I/B FLAP LOWER O/B SEAL IAW AMM 27-51-11.SDR CALA2025100209561Life Raft · not reportedINFLATABLE LIFE RAFT REPLACE - REMOVED AND REPLACED LIFE RAFT ACT ACT REF TASK CARD 29-2560-1-9801SDR CALA2025100209552Gauge · no discrepancyR2 DOOR GAUGE IN THE RED. SLIDE GAGE 1 NEEDLE WITH ON HIGH SIDE OF RED. OK FOR SERVICE REF AMM 25-66-01SDR CALA2025100209542Proximity Sensor · damagedPOST FLT REP NOT SENDING WITH MCD OPEN MCDU DISPLAYED MAIN CABIN DOOR OPEN REQD WHEN CREW TRIED TO SEND POST FLIGHT REPORT. CYCLED MAIN CABIN DOOR OPEN AND CLOSED MULTIPLE TIMES, MESSAGE CLEARED. DOOR 1L DOOR SENSOR REPORTING TO ACARS INTERMITENT, NEEDS MORE TSDR CALA2025100209529Battery Pack · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. EMERGENCY LIGHTS INOP, ROW 7 TO 14. REPLACED BATTERY PACK AT ROW 8A, SN OFF 309032, SN ON 375810. REF AMM 33-51-06, ROWS 7 THRU 14 CHECK GOOD.SDR CALA2025100209523Oven · odorOVEN 204 EMMITS STRONG BURNING SMELL, CLEANED OVEN AND PEFORMED OPS CHKD GOOD.SDR CALA2025100909833Seat Track · corrodedMID WET AREA AFTER FURTHER EVALUATION ON SEAT TRACK BETWEEN STA 500C AND STA 500E LBL 24, FOUND TO BE OUT LIMITS. REPAIRED AND RESTORED MID WET AREA ON SEAT TRACK BTW STA 500C-ST A 500E LBL24 IAW B737 SRM 53-00-52-2R-4,SRM 51-40-05-0G-0,SRM 51 -40-08-0G-0,SRMSDR CALA2025100809789Seat Track · corrodedMID WET AREA AFTER FURTHER EVALUATION ON SEAT TRACK BETWEEN STA 500C AND 500E LBL 45 FOUND TO BE OUT LIMITS, REQUIRE REPAIR. REPAIRED AND RESTORED MID WET AREA ON SEAT TRACK BTW STA 500C-ST A500E LBL45 IAW SRM 53-00-52-2R-4,SRM 51-40-05-0G-0,SRM 51-40-08-0G-SDR CALA2025100709738Support Beam · damagedCENTER LOWER SUPPORT BEAM LOWER CHORD RBL 540 DAMAGED. PRIMARY STRUCTURE REQUIRES R IAW SRM 57-10-13-2R-3 MATERIAL ID FOR STRAP ITEM (1) AND FILLER ITEM (4), 7075 T6 .125" PO#3919569330. LOCATION CORRECTION, DAMAGE IS OF THE LOWER SUPPORT BEAM LOWER CHORD ASDR CALA2025100209563Wire Harness · chafedEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. EXIT ROW EMERGENCY LIGHT AT SEAT 3AB(AFT LIGHT) IS INOPERATIVE. PERFORMED GVI OF SEAT EMERGENCY LIGHTS HARNESS AND FOUND HARNESS DAMAGED INSIDE TRAY TABLE POCKET. HARNESS REPLACEMENT REQUIRED PARTS UPDATED PERFORMSDR CALA2025100309582Fairing · crackedFOUND CRACK NO-2 PYLON LOWER FIXED FAIRING INTERNAL AFT SUPPORT RIB MKD DOT 022 REF AAR N/R 99957175 ESFR ENTERED. REMOVED AND REPLECED # 2 PYLON AFT FAIRING EDGE ASSY AS PER B737 SRM 51-40-02-0G-0 AND DWG'S 313A2400 AND 313A2750.SDR CALA2025102610514Floor Support · crackedMAIN CABIN FLOOR SUPPORT INTERCOSTAL HAS 2EA CRACKS BETWEEN STA 277 AND 294.5 AT BLO IN THE UPPER SURFACE COMMON TO THE FLOOR BOARD FASTENER HOLES. CLEANED INTERCOSTAL, FOUND 100% OUT OF LIMITS. LOCATED AND DRILLED AND INSTALLED NEW INTERCOSTAL IAW BDWG 141ASDR CALA2025102610511Floor Support · cracked(B737-53-3-0711) MAIN CABIN FLOOR SUPPORT INTERCOSTAL UPPER SURFACE IS CRACKED AT THE FLOOR BOARD FASTENER HOLE STA 312 AND 328 AT APPROX LBL46. BLENDED OUT INTERCOSTAL, FOUND 100% OUT OF LIMITS. REMOVED, LOCATED AND DRILLED NEW INTERCOSTAL AND INSTALLED AT SDR CALA2025092909349Charger · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK, FOUND SEAT ROW 8ABC TO 14ABC FLOOR PROXIMITY LIGHT INOPS. FOUND BAD POWER SUPPLY M02503. NEED POWER SUPPLY AND BATTERY.. REPLACED BATTERY CHARGER AND BATTERY PACK AT M02503, PER AMM 33-51-06-960-805, OPS OK.SDR CALA2025093009449Control Unit · faultedHIGHSPEED REJECT 120KTS OVHT/DET MAST CAUTION AND FUEL. CTR TANK S LT FIRE FAULT/APU DT INOP REPORTED BY PILOT. REF LOGPAGE 6438947 FOR ORIGINAL LOG PAGE. CLOSED ORINGINAL REFER LP 6440071,. SEE THOSE FOR WORK COMPLETED REGARDING THIS EVENT. BOTH CENTER FUEL TSDR CALA2025093009429Lens · missingFWD COAT CLOSET EMERG EXIT LIGHT COVER MISS ING. LT WORKS. REPLACED LENS AT CORNER OF LH FW CLOSET. LIGHT OPS CHECK GOOD. REF IPC 33-14-00-02 AND EA3314-01014.SDR CALA2025092909355Power Supply · inoperativeR2 DOOR EMERGENCY LIGHTS INOP REPLACED R2 DOOR EMERGENCY LIGHTS BATTERY PACK AND POWER SUPPLY POSITION M1672 PER AMM 33-51-06, OPS CHECK GOOD, NO DEFECTS NOTED AT THIS TIME, A/C OK TO CONTINUE.SDR CALA2025092909354Battery Pack · faultedROW 1EF-7DEF OVERHEAD BIN EMERGENCY LIGHTS INOPERATIVE. REPLACED ROW 1EF-7DEF OVERHEAD BIN EMERGENCY LIGHTS BATTERY PACK AND POWER SUPPLY POSITION M1676 IAW AMM 33-51-06, OPS CHECK GOOD, NO DEFECTS NOTED. ACFT OK TO CONTINUE SERVICE.SDR CALA2025092909387Door · missingLAVATORY SERVICE DOOR MISSING. PERFORMED INSTALLATION OF WASTE TANK SERVICE DOOR IAW AMM 52-49-01.SDR CALA2025092909351Light · detachedSEAT 5B HAS EMERGENCY LIGHT ASSY HANGING BY AISLE SIDE SECURED AISLE EMERGENCY LIGHT AT SEAT 5B. REF CMM 25-22-51SDR CALA2025110410881Skin · cracked[EA 5510-01843]- CRACK FOUND AT LEFT HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 157.10 , 23" FROM FRONT SPAR , I/B ROW. CRACK LENGTH: 1.5". REF AAR N/R 99951973 ACCOMPLISHED REPAIR ON LEFT HORIZONTAL STABILIZER LOWER SKIN, AT STA: 157.10, 23.0" FROM FRONT SPSDR CALA2025092909393Module · faultedSTABILIZER FAILS TO TRIM NOSE UP & NOSE DOWN FULL ELECTRIC TRIM FAIL SPEED TRIM FAIL LIGHT ILLUM UPON INITIAL EVALUATION TRIM SWITCHES ARE INOP. PERFORMED FIM 22-11 TASK 849. FOUND FAULT 22-11161, 22-11182, 22-11186. PERFORMED FIM 22-15 TASK 821. HORIZONTAL SSDR CALA2025092909371Cover · broken34ABC AISLE EMERGENCY LIGHT BROKEN REF AMM 33-51-11 REPLACED FLOOR PROXIMITY LIGHT. VERIFIED LIGHT OPERATIONAL.SDR CALA2025092909361Switch · fodAFT CARGO LIGHT ON TAKEOFF WENT OUT AT 10K CAME BACK ON AT T/D VERIFIED AFT CARGO DOOR IS SECURED AND CLOSED. MEL APPLIED PERFORMED VISUAL INSPECTION. FOUND FOD IN WIRING OF AFT CARGO DOOR SWITCH. REMOVED FOD. OPS CHECK GOOD. OK TO CONTINUESDR CALA2025092909366Skin · delaminatedUPON EXTERNAL WALKAROUND FOUND OUTBD RIGHT TRAILING EDGE FLAP DELAMINATED. INSPECTED FLAP TRACKS AND HDWR, STARTED INSTALLATION OF R/H OUTBOARD AFT FLAP REF AMM 27-51-22-400-801 STEPS 3G THRU 3H (4)-(F) VERIFIED R/H OUTBD AFT FLAP INSTALLATION STEPS 3G-3H(4SDR CALA2025092609312Repair · missingDURING EXTERNAL WALKAROUND, FOUND AREA ON RT OTBD FLAP, INBD TRAILING EDGE HAD A PREVIOUS REAPAIR OF APPROXIMATELY 69.56 SQ/IN WITH REPAIR DOUBLER MISSING AND AN AREA OF APPROXIMATELY 28 SQ/IN DELAMINATED. WORK WILL BE ACCOMPLISHED ON ORIGINAL LOG 6397083.SDR CALA2025092609307Floorbeam · crackedMID CABIN FLOORBEAM FOUND CRACKED AT BS 540 BETWEEN BL 0 AND LBL 24.75. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-02-0G-0, AND DWG 143A5240.SDR CALA2025092609285Girt Bar · no discrepancyR2 DOOR ESCAPE SLIDE MATERIAL IS TOUCHING THE FLOOR, INSPECTED R2 DOOR SLIDE GIRT. FOUND WITHIN LIMITS IAW AMM 25-66-01-400-803. OK FOR SERVICE.
Back to Boeing 737-924ER