Boeing 737-924ER
Service difficulty reports · 3,682
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025092609296Floorbeam · corrodedMAIN CABIN FLOORBEAM AT STA 987 RBL45 CORRODED AT GIRT BAR FITTING HOLE. CORROSION LEVEL. 2 - OUT OF LIMITS ON PRIMARY STRUCTURE. REPAIRED BS 987 FLOORBEAM AT RBL 45 IAW SRM 53-70-51-2R-6.SDR CALA2025092609295Floorbeam · corrodedCORROSION AT CABIN FLOORBEAM STA 947, RBL 28. REPAIR ACCOMPLISHED ON THE MAIN CABIN FLOORBEAM STA 947 IAW EC/RA 5370-01198 & SRM 53-70-51-2R-5.SDR CALA2025092609294Hmu · failedLEFT ENGINE DID NOT PRODUCE TAKE OFF POWER. MAX THRUST REQUESTED L 97-98 MAX WHEN 101. AIR RETURN, REMOVED AND REPLACED HMU ASSEMBLY ON NR 1 ENGINE IAW AMM 73-11-01-400-801. LEAK CHECKED GOODSDR CALA2025092509261Floorbeam · corrodedMAIN CABIN FLOORBEAM AT BS 987 LBL45 CORRODED AT GIRT BAR FITTING HOLE (DOME NUT) LOCATION. REMOVED CORROSION, FOUND TO BE 100%, OUT OF LIMITS IAW SRM 53-70-51-1A-1 DETAIL C. REPAIRED AREA IAW SRM 53-70-51-2R, REPAIR 6, & SRM 51-20-01. ACCOMPLISHED DVI IAW SSDR CALA2025092409218Bolt · looseLEFT WHEEL WELL, AILERON CABLE PULLEY HARDWARE BACKING OFF. AMM-20-51-11-910-801. RETORQUED HARDWARE. NO DEFECTS NOTED.SDR CALA2025092409192Unknown · odorON TAKEOFF AND DESCENT BAD ODOR SUSPECTED FROM PACKS PERFORMED IDLE CHECK BOTH PACKS RUNNING AUTO AND HIGH FIVE MINUTES NO SMELLS. RAN BOTH ENGINES FIRST RUN AND ONE AT 75% AND TWO AT 90% FOR FIVE MINUTES., POWER UP TO N1 84% AND N2 93% FIVE MINUTES NO SMELLSSDR CALA2025092409217Structure · crackedL1 DOOR INNER CHORD CRACKED AT STA 312. REMOVED AND REPLACED L1 DOOR INNER CHORD AS PER SRM 51-40-02-0G-0 AND DWG 141A8110,SDR CALA2025092409196Light · detachedSEAT ROW 8 EMERGENCY LIGHT ASSY DETACHED FROM SEAT. REPLACED LIGHT HOUSING WITH NEW, REFERENCE AMM TASK 33-51-11-960-802.SDR CALA2025092309170Battery Pack · inoperativeEXIT ROW EMERGENCY LIGHTS INOPERATIVE ROWS 15-21, RED EMERGENCY AISLE LIGHTS INOPERATIVE. REPLACED ALL 4 FUSES IN POWER SUPPLY AND SWAPPED IN NEW BATTERY AT BS 570 ON ACFT LEFT (FWD OF ROW 20A FLOOR PANEL), NO HELP. SWAPPED IN NEW BATTERY CHARGER WITH NEW SDR CALA2025092409213Skin · damagedREF LOG PAGE 5420901 FOR REPAIR OF TAILSTRIKE DAMAGE TO AFT LOWER FUSELAGE. R & R SKIN ACCOMPLISHED. OK TO CLEAR.SDR CALA2025092409195Light · brokenEMERGNCY EXIT PLACARD LEFT N RIGHT CHIP REMOVED AND REPLACED RH/LH OVERWING EMERGENCY EXIT LENS COVERS REF CONFIGURATION DRAWING NO. 3351DD15945. PRECAUTIONARY PERFORMED EMERGENCY LIGHTS OPS CHECK REF AMM 33-51-00-710-801, OPS CHECK GOOD AT THIS TIME.PARTS USESDR CALA2025092409194Light · broken9ABC EMERGENCY EXIT LIGHT TRIM PIECE BROKEN. LIGHT IS LAYING ON FLOOR ATTACHED BY LIGHT CABLE. RAR EMERGENCY LIGHT FLOOR PROXIMITY PATH LIGHT ASSY PER AMM 33-51-11-960-802. NO FURTHER DEFECTS NOTED AT THIS TIME. A/C OK FOR SERVICE.SDR CALA2025092209073Potable Water · contaminatedMULTIPLE PAX AND FAS STATE THAT HOT WATER, SMELLS AND TASTES LIKE CHE MICALS, CA SMELLED TO CONFIRM. DRAINED PORTABLE WATER TWICE. RESERVICED AND RAN WATER THRU ALL COFFEEMAKERS AND RAN ALL LAVS SINK WATER. NO SMELL. AC OK FOR SERVICESDR CALA2025092609290Attach Angle · crackedFOUND A CRACK ON LOWER FUSELAGE RT REAR SPAR VAPOR BARRIER UPPER ATTACHED ANGLE AT RBL 7, BS 663.75. REPAIR ACCOMPLISHED IAW SRM 57-10-10-2R-5 PAGE 1-7,11-12 FIGURE 202 SHEET 6. PSDR CALA2025092409211Attach Angle · crackedFOUND CRACK LOWER FUS LT REAR SPAR VAPOR BARRIER UPPER ATTACH ANGLE AT LBL 7 BS 663.75. REPAIR ACCOMPLISHED IAW SRM 57-10-10-2R-5 PAGE 1-7,11-12 FIGURE 202 SHEET 6.SDR CALA2025092209103Channel · corrodedFWD CARGO LEFT "Z" CHANNEL IS CORRODED AT B/S 500D-500L. REMOVED AND REPLACED LEFT Z-CHANNEL SECTION AND SPLICE FROM STA 500D TO 500L PER SRM 51-40-02-0G-0 AND DWG#143A7500.SDR CALA2025092209070Unknown · odorVERY MUSTY SMELL FROM PACKS ON GROUND. MULT PASSENGER COMPLAINTS. HAD CREW FILL OUT SMOKE/ODOR FORM. INSPECTED BOTH ENGINE COMPRESSOR INLETS FOR EVIDENCE OF INGESTION, NONE FOUND. INSPECTED APU INLET FOR EVIDENCE OF INGESTION, NONE FOUND. RAN PACKS ON APU BSDR CALA2025092409210Floor Support · crackedCRACKED UPPER INTERCOSTAL STRAP AT FWD CABIN STA. 380 BL 0. REMOVED AND REPLACED UPPER INTERCOSTAL STRAP AT STA 380-400 BL 0 AS PER SRM 51-10-02-0G-0 AND DWG 143A5400. REMOVED AND REPLACED UPPER INTERCOSTAL STRAP AT STA 380-400 BL 0 AS PER SRM 51-10-02-0G-0 ASDR CALA2025100709731Intercostal · corrodedEXFOILIATED OUT OF LIMITS CORROSION AT INTERCOASTAL BETWEEN STA 947 & STA9 67 RBL-28. REPLACED INTERCOSTAL BETWEEN STA 947.5 & STA 967 RBL-28 (REMOVAL AND INSTALLATION ACCOMPLISHED IN TASK CARD SERIAL #: 99946877) PER REF SRM 51-40-05-0G-0, AMM 51-21-41-370-SDR CALA2025100609634Floorbeam · crackedFOUND CRACK LOWER FUS CTR REAR SPAR R/H VAPOR BARRIER UPPER ATTACHED ANGLE RBL 7 STA 663.75. ACCOMPLISHED STA-663.75 RT VAPOR BARRIER ATTACH ANGLE SPLICE REPAIR FROM RBL-5 TO RBL-30 AS PER SRM 57-10-10-2R-5 .SDR CALA2025092209089Angle · crackedFOUND CRACK LOWER FUS CTR WING REAR SPAR L/H WAPOR BARRIER UPPER ATTACHED ANGLE LBL 7 STA 663.75. ACCOMPLISHED STA-663.75 LH VAPOR BARRIER ATTACH ANGLE SPLICE REPAIR FROM LBL-5 TO LBL-35 AS PER SRM 57-10-10-2R-5.SDR CALA2025091909041Bleed Valve · inoperativeLEFT ENGINE BLEED PRESSURE INDICATES 7PSI IN CLIMB & CRUISE, OPENED NR 1 ENGINE & TR FOUND NO OBVIOUS VISIAL DESCREPENCIES. OPENED & CLOSED NR 1 ENGINE. PERFORMED HIGH POWER RUN REF FIM 36-10 TASK 804. ZERO DUCT PRESSURE ON ENG NR 1 AT ALL POWER LEVELS. PSDR CALA2025091709000Floor Support · corrodedEXFOILATED CORROSION BETWEEN STA 947 & STA 967 RBL -50. REMOVED AND REPLACED FLOOR SUPPORT BETWEEN STA 947.5 AND STA 967 RBL 50 IAW SRM 51-40-05-0G-0,SRM 51-40-02-0G-0 AND DWG 147A5760SDR CALA2025091608984Fuse · failedEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. AISLE PATH EMERGENCY LIGHTS ROWS 6ABC, 7ABC, 8ABC, 9ABC, 10ABC, 11ABC INOPERATIVE. REPLACED POWER SUPPLY FUSES ALONG SIDEWALL BEHIND MID LAV IAW AMM 33-51-06-960-804. OPS CK GOOD OF AISLE PATH LIGHTS.SDR CALA2025091608961Battery Pack · dischargedALL OF FIRST CLASS EMERGENCY PATHWAY LIGHTS INOP EMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - REPLACED BATTERY PACK FUSES FOR FIRST CLASS EMERG LIGHTS REF AMM 33-51-06, NO HELP. OPS TESTED EEL LIGHTS. ALL LIGHTS CONNECTED TO BATTERY PACK M28SDR CALA2025091809040Actuator · trippedDURING FINAL APPR FLAPS GOT STUCK AT FLAPS 5. PERFROMED CHECKLIST. USED ALTERNATE FLAPS SWITCH. CREW STATES, FLAPS 30 SELECTED ON APPROACH INTO ORD. SOMETHING FELT WRONG AND LOOKED AT FLAP MECHANICAL INDICATOR ON FWD PANEL & FLAPS LOCKED AT 5 DEGREES & NEESDR CALA2025091809039Radome · no discrepancyREJECTED T/O FOR BIRDSTRIKE TO THE NOSE AT AROUND 115 KNOTS PERFORMED BIRDSTRIKE INSPECTION REF AMM 05-51-18-210-801. FOUND SMALL BLOOD SPOT ON UPPER RIGHT SIDE OF NOSE RADOME. CLEANED BIRDSTRIKE AND INSPECTED AREA WITH NO DEFECTS NOTED,SDR CALA2025091709002Door · out of adjustFLIGHT CREW INDICATED DURING CREW DEBRIEF THAT LANDING GEAR FAILED TO RETRACT. DURING INITIAL EVALUATION FOUND ALT GEAR EXT HANDLE DOOR IN COCKPIT NOT SEATED. CREW INDICATED CYCLED ALT GEAR EXT HANDLE DOOR & VERIFIED CLOSED. ATTEMPED ANOTHER GEAR RETRACTIONSDR CALA2025091708987Slide · no discrepancySLIDE STICKING OUT OF GIRT BAR DOOR 1L INSPECTED 1L SLIDE PACK ORIENTATION, Z FOLD CORRECT AND CORRECT SLIDE PRESSURE GOOD REF AMM 25-66-01-200-802.SDR CALA2025091608950Light · inoperativeL2 DOOR EMERGENCY LIGHT INOP REMOVED AND REPLACED L2 DOOR EMERGENCY LIGHT IN REF WITH AMM 33-51-04. OPS CHECK GOOD.SDR CALA2025091709001Flap · no discrepancyFLAP OVERSPEED AT FL10 BY 4 KNOTS. PERFORMED PHASE 1 INSPECTION IAW AMM 05-51-08-210-801. NO DEFECTS FOUND. OK FOR SERVICESDR CALA2025091608966Valve · faultedRTO 50 KTS PULLING LEFT DURING OPS CHECK OF N/W STEERING FOUND WHEN TURNING FULL LEFT METERING VALVE STICKS THEN RETURNS TO CENTER SLOWLY, CAN ALSO HEAR VALVE BYPASSING INTERNALLY. RECOMMEND METERING VALVE R/R. T/S USING FIM 32-51 TASK 810. REMOVED NLG STEERINSDR CALA2025091608959Girt Bar · no discrepancyDOOR L2 GIRT BAR HAS A PIECE OF CLOTH THAT DOEST LOOK NORMAL REPOSITIONED SLIDE BUSTLE MATERIAL. OPS CHK IS GOOD. SLIDE REMOVAL NOT NESSASARY.SDR CALA2025091508912Seat Track · corrodedMID PASSENGER COMPARTMENT FLOOR SEAT TRACK LBL24.75 BETWEEN STA 500D AND STA500E SHOWS CORROSION IN SEVERAL PLACES. INSTALLED SEAT TRACK REPAIR SPLICE CHANNELS BETWEEN STA 500C/D : 500E/F AND A NEW SEAT TRACK SECTION FROM STA 500C+10 TO STA 500E+10 AT LBL 24SDR CALA2025091508911Fuse · failedFLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOPERATIVE ON THE SEATS OF ROWS 1AB THRU 5AB. (TOTAL OF 10 WHITE LIGHTS). REMOVED AND REPLACED OPEN FUSE ON POWER SUPPLY M02816. OPS CHECK OF EMERGENCY LIGHTS, GOOD. REF AMM 33-51-06.SDR CALA2025091508910Light · damagedONE WHITE EXIT LIGHT ON ARMREST AT 3B INOPERATIVE. ADJACENT LIGHTS FWD AND BEHIND INOPERATIVE LIGHT ARE OPERATIVE. NO EMERGENCY LIGHTS WORK. LENS FOR WHITE FLOOR PROXIMITY LIGHT ON SEAT 3B IS DAMAGED. ALL FLOOR PROXIMITY LIGHTS FWD AND AFT OF 3B LOCATION OSDR CALA2025091508887Acm · failedRIGHT PACK LIGHT ILLUMINATED PERFORMED DCPC BITE TEST, REF FIM 21-31 TASK 801, NO EXISTING FAULTS ON DCPC 1 OR 2. RAN RIGHT PACK AND ACM IS NOT TURNING PUTTING OUT EXHAUST AND CAUSING A OVERHEAT. ACM REPLACEMENT REMOVED AND REPLACE IAW AMM 21-51-04. RT PACK SDR CALA2025091508873Battery Pack · no testEMERGENCY LIGHTS FROM ROW 28-34 INOP REMOVED AND REPLACED BATTERY PACK ON M1898 IN CEILING PANEL AT ROW 28 REF MM 33-51-06. OPS CHECKS GOODSDR CALA2025091508916Control Chain · out of adjustTRIM WHEEL NOT CORRECT, PILOT REPORTS AN UNUSUAL GRINDING NOISE FROM RT STAB TRIM WHEEL IN FLT. ALSO REPORTED A NOISE SIMILAR TO THAT OF SERVO ACTUATION, SOUNDED LIKE A SPEED BRAKE SERVO IAW PILOT STABILIZER CONTROL CHAIN. FOUND TO NEED ADJUSTMENT. ADJUSSDR CALA2025091508897Girt Bar · out of adjustR1 GIRT BAR FLAP LOOSE. GIRT BAR ADJUSTED OK FOR SERVICE.SDR CALA2025091508895Bracket · unsecureR2 DOOR SLIDE BRACKET LOOSE. SECURED FLOOR-MOUNTED ESCAPE SLIDE BRACKET IAW AMM 25-66-02-000-801 & AMM 25-66-02-400-801SDR CALA2025091508882Unknown · odorELECTRICAL ODOR IN CABIN ON ROTATION. ODOR SINCE DISSIPATED NOTHING ELSE ABNORMAL COMPLETED ECRA 0500-01013 UP TO STEP C(2) D. CONTINUE AT STEP C(2) E. FOUND NOISE COMING FROM RIGHT PACK BAY, SUSPECT ACM. DID FURTHER TROUBLSHOOTING USING FIM 21-00 TASK SDR CALA2025091208826Lens · missingEMG LIGHT SWITCH COVER STATION 712. INSTALLED EMERGENCY LIGHT ASSEMBLY LENS NEAR AFT LOWER EDGE OF COMPRTMENT #712 COAT CLOSET. EMERGENCY LIGHT FUNCTIONL CHECKS GOOD REF. AMM 33-51-00 / CMM 25-20-23SDR CALA2025091508893Bracket · no discrepancySERVICE DOOR EMERG SLIDE BAR FLOOR BRACKET LOOSE. INSPECTED SERVICE DOORS SLIDES IAW AMM 25-66-01. NO DAMAGE OR LOOSE BRACKETS FOUND. NOTICED NEXT TO 2R DOOR FA SEAT CLIP DETACHED. ADJUSTED CLIP TO FA SEAT.SDR CALA2025091208862Duct · blownBLEED TRIP OFF LIGHT COMES ON DURING CLIMB LIGHT NO. 2 RESET DONE DUCT PRESS SPLIT RIGHT DUCT 16 PSI LEFT DUCT 40 PSI FOUND E2 PRECOOLER DUCT ASSY. BLOWN OFF REMOVED AND REPLCED E2 PRECOOLER DUCT ASSY. REF: AMM 36-12-01-000-801.PARTS USED: 29-3611-3-0032,QTYSDR CALA2025091208837Angle · damagedON THE L/H HORZ BEAM ANGLE. ACCOMPLISH INSPECTION REQUIREMENTS PER PART 2 OF EC/RA 5380-01429 ON OR BEFORE 09 SEPT 2027. ON THE LH REAR SPAR HORIZONTAL BEAM ANGLE ACCOMPLISH REQUIREMENTS PER PART 2 OF EC/RA# 5380-01429.SDR CALA2025091108767Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE AT ROWS 8 THRU 14 IN MAIN CABIN. SWAPPED 2503 BATTERY AND CHARGER, NO HELP. TRIED OTHER BATTERIES FROM OTHER LOCATIONS, NO HELP. 2503 DOES TEST. HOWEVER ONLY T-LAV LOWER LIGHTS AND 2 CEILING LIGHTS FUNCTION. TESTED ALL BATTERY PSDR CALA2025091108766Battery Pack · inoperativeEMERGENCY FLOOR LIGHTS ROW 35 AND UP, PLUS 2L DOOR LIGHTS OUT. REMOVED AND REPLACED BATTERY PACK, REF AMM TASK 33-51-06-960-805. OPS CKS NORMAL.SDR CALA2025091108764Girt Bar · fodDOOR 2R GIRT BAR GETTING STUCK IN THE BRACKET PERFORMED INSPECTION OF DOOR 2R GIRT BAR HOLDER FOUND DIRT AND DEBRIS BETWEEN BRACKET. CLEANED BOTH BRACKETS. COULD NOT DUPLICATE DEFECTSDR CALA2025091108763Girt Bar · out of adjustF/A REPORTS DOOR 2L GIRT BAR IS DIFFICULT TO REMOVE FROM STOWED POSITOIN. ADJUSTED 2L GIRT BAR SO THAT IT FITS ITS STOWAGE CLAMPS.
Back to Boeing 737-924ER