Boeing 737-924ER
Service difficulty reports · 3,682
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2020100701156Switch · defectiveELECTRIC TRIM WILL NOT TRIM UP STAB OUT OF TRIM SPEED TRIM FAIL T/S, IAW FIM 27-41-00-810; WDM 27-41-11, WDM 27-41-12. FOUND F/O COLUMN SWITCHING MODULE(M1201) AT FAULT STAB TRIM PITCH UP WORKED, IAW MM 27-41-51. PITCH TRIM UP WORKED CONSISTANTLY, BUT LAND VSDR CALA2020092601149Tube · severedNR 1 ENGINE FIRE EXTINGUISHING TUBE P/N 364A3101-6 SEVERED AT LT WING REAR SPAR AFT OF AFT STRUT FAIRING, REF. AAR N/R:99900255. GENERATED BY : V925564. REMOVED AND REPLACED NR 1 ENGINE FIRE EXTINGUSHING TUBE P/N 364A3101-5, AS PER B737 AMM 20-10-51-000-801 SDR CALA2020092101133Charger · inoperativeEMERGENCY BATTERY PACK M1695 WILL NOT TURN OFF EMERGENCY LIGHTS SPT 7002823. REMOVED AND REPLACED BATTERY PACK M1695, IAW B737NG AMM 31-51-06. OPS CHECK PASSES SSFR REPORT FORM 46-0024 ENTERED BY UAL INSPECT ION U354653 7/18/20 DATA TRANSCRIBED FROM NR 70028SDR CALA2020091801132Battery Pack · inoperativeEMERGENCY BATTERY PACK M1694 INOP. REMOVED AND REPLACED M1694, AS PER AMM 33-51-06-960-805. OPS CHECKS NORMAL.SDR CALA2020091501112Trim System · malfunctionedCREW REPORTS STAB TRIM WILL NOT ELECTRICALLY IN THE UP POSITION PERFORMED FIM 27-41-00-810-800. OPS CHECK GOOD AND PERFORMED CAT III TEST, PER AMM 22-11-00.SDR CALA2020091501108Check Valve · failedA/C WILL NOT PRESSURIZE IN AUTO/MANUAL. REMOVED CHECK VALVE, REF MM 21-21-01-000-804-002, PARTS AND HARWARE IN AREA. ADD EMP:U353062 PARTS RECEIVED. TETR 1930. REPLACED CHECK VALVE, PER AMM 21-21-01-000-804-002-2. OPS CHECKS GOOD WITH NO LEAKS NOTED.SDR CALA2020091501102Battery Pack · dischargedEMERGENCY LIGHTS IN UPPER CABIN AT ROW 29 & 34 INOP. REPLACED BATTERY PACK LOCATED ON CEILING PANEL AT 31 DEF, AS PER AMM 33-51-06-960-805. LIGHTS CHECK GOOD. LOG CLEARED.SDR CALA2020091501101Battery Pack · dischargedEMERGENCY EXIT LIGHTS AT RIGHT OVERWING EXIT DOOR INOP. REPLACE BATTERY PACK AT M 1695, PER AMM 33-51-06-960-805. OPS CHECKS GOOD.SDR CALA2020091501100Control Panel · malfunctionedINFLT WX RADAR FAILED SCREEN SHOWS WXR FAIL CONT STAB. REMOVED AND REPLACED WEATHER RADAR TRANSCEIVER M.M. 34-43-41. DURING OPS CHECK M.M. 34-43-00 WEATHER RADAR WOULD NOT TEST. TEST LIGHTS ON RADAR CONTROL PANEL WERE INTERMINTENT. REMOVED AND REPLACED RADSDR CALA2020081101094Control Panel · stuckAUTO PRESSRIZATION PANEL ALTITUDE SELECTOR STUCK AT 36500 TROUBLESHOOT PER FIM 21-31-00-810-803 K. R & R CABIN PRESSURE CONTROL PANEL IAW TASK 21-31-02-000-801 AND TASK 21-31-02-400-801 AND GROUND TEST TASK 21-31-00-700-802 TEST GOOD.SDR CALA2020080901092Proximity Switch · faultedLANDING GEAR WILL NOT RETRACT PSEU BITE SHOWS NO PRIMARY POWER TO LGTV AND MESSAGE 29-20001. RIGHT GEAR GROUND SHIFT TELEFLEX CABLE IS INTACT. REQUIRES FURTHER TS AULS, PSEU SHOWS VALID VOLTAGE FROM D11138. PER FIM PSEU REQUIRES REPLACEMENT. OF C/B''S ,CHECKEDSDR CALA2020080901088Pump · inoperativeHYDRAULIC PRESSURE INDICATED ZERO FOR SYSTEM B. REPLACED THE NR 2 ENGINE HYD PUMP IAW 29-11-11.SDR CALA2020080901084Skin · crackedFOUND A CRACK AT SURROUNDING DOUBLER LWR FWD ZONE OF ELECTRICAL GROUND POWER RECEPTACLE DOOR CUT OUT. REPAIRED EGPR DOOR CUT OUT DOUBLER IAW SRM 53-10-15, REPAIR 4, FIG. 204, SHEET 1 & 2.SDR CALA2020080901082Doubler · crackedFOUND A CRACK AT SURROUNDING DOUBLER LWR FWD ZONE OF ELECTRICAL GROUND POWER RECEPTACLE DOOR CUT OUT. REPAIRED THE DAMAGED DOUBLER IAW SRM 53-10-15, FIG 204, REPAIR 4.SDR CALA2020072001063Rod · damagedWHILE PERFORMING WALKAROUND, FOUND THE RT INBOARD AFT FLAP IN THE EXTENDED POSITION. DURING INSPECTION, FOUND THE FLAP ACTUATING MECHANISM ROD DAMAGED, FLAP DRIVE ATTACH FITTING DISCONNECTED AND SHEARED OFF FASTENERS. ALSO FOUND DAMAGE INSIDE BOTTOM OF FLAP CSDR CALA2020072001061Pitot Head · obstructedAFTER TAKE OFF A/T DISCTD AND EEC ILL W/ SPD TRIM FAIL AND A/S DISAGREE RRH FOLLOWD RETURNED TO DEPARTURE. FOUND DEBRIS IN F/O PITOT TUBE, FLUSHED WITH NITROGEN. DISCONNECTED AND REMOVED F/O'S PITOT TUBE AND RIGHT ADM. PURGED LINE BETWEEN BOTH PITOT AND SDR CALA2020072001057Skin · dentedLH NOSE FUSELAGE SKIN FWD AND ABOVE THE L1 DOOR BETWEEN S-5L AND S-6L AT APPROX STA 272 HAS A DENT THAT MEASURE 1.7"X 3.7" X .022" DEEP. ACCOMPLISHED PART 1 AND PART 1A OF ECRA 5330-06406.SDR CALA2020071201052Charger · inoperativeRH FWD OVERWING EMERGENCY LIGHT KAPUT. REPLACED CORRESPONDING BATTERY CHARGER AND BATTERY PER AMM 33-51-06, OPS NORMAL ADD EMP:94595SDR CALA2020070401038Placard · missingPER ''A'' CHECK PAPERWORK, ISO IDENTIFICATION STICKER MISSING FROM F/O HARNESS REEL. SHOULDER HARNESS REEL ASSY NEEDS REPLACED. REPLACED F/O SEAT SHOULDER HARNESS AND REEL ASSY. OPS NORMAL. REF AMM25-11-00. PER GMM 09-25-05 FLIGHT DECK SEATS. VERIFY SAFSDR CALA2020060801013Power Supply · inoperativeM2626 EMERGENCY POWER SUPPLY PUSH TO TEST BUTTON STICKS. JUST ABOVE SEAT 30ABC MOUNTED ON CEILING PANEL REMOVED AND REPLACED M2626 EMERGENCY POWER SUPPLY ASSY WITH SERVICABLE UNIT, RO 5021132. OPS CHECK GOOD REF AMM 33-51-01-960-806. OPS CHECK GOOD.SDR CALA2020060801012Battery Pack · dischargedEMERGENCY AISLE PATH LIGHTING INOP AT ROWS 27 THRU 34 T/S AISLE PATH LIGHTING, FOUND M2626, BATTERY PACK TO BE FAULTY, REMOVED AN REPLACE BATTERY PACK WITH SERVICABLE UNIT. RO 5158418 REF AMM 33-51-06-960-805.SDR CALA2020053101008Battery Pack · dischargedEMERGENCY EXIT LIGHT POWER SUPPLY M1676 FAILS CAPACITY CHECK REF JC 29-012 1-5801. REPLACED BATTERY PACK FOR MM1676 IAW AMM 33-51-06-960-805. DADO PNL NEEDS TO BE INSTALLED AND CAPACITY CHECK NEEDS TO BE ACCOMPLISHED IAW AMM 33-51-06-200-801 FOR JC 29-1012-1SDR CALA2020053101007Battery Pack · dischargedEMERGENCY EXIT LIGHT POWER SUPPLY M2627 FAILED CAPACITY CHECK REF JC 29-1012-1-5801. REPLACED BATTERY PACK FOR M2627 IAW AMM 33-51-06-960-805. CEILING PNL NEEDS TO BE INSTALLED AND CAPACITY CHECK NEEDS TO BE ACCOMPLISHED IAW AMM 33-51-06-200-801 FOR JC 29-10SDR CALA2020053101006Battery Pack · dischargedEMERGENCY EXIT LIGHT POWER SUPPLY M2626 FAILED CAPACITY CHECK REF JC 29-1012-1-5801. REPLACED BATTERY PACK FOR M2626 IAW AMM 33-51-06-960-805. CEILING PNL NEEDS TO BE INSTALLED AND CAPACITY CHECK NEEDS TO BE ACCOMPLISHED IAW AMM 33-51-06-200-801 FOR JC 29-10SDR CALA2020053101005Battery Pack · dischargedEMERGENCY EXIT LIGHT POWER SUPPLY M1695 FAILS CAPACITY CHECK REF JC 29-1012-1-5801. REPLACED BATTERY PACK FOR M1695 IAW AMM 33-51-06-960-805. DADO PNL NEEDS TO BE INSTALLED AND CAPACITY CHECK NEEDS TO BE ACCOMPLISHED IAW AMM 33-51-06-200-801 FOR JC 29-1012-1SDR CALA2020053101004Battery Pack · dischargedEMERGENCY EXIT LIGHT POWER SUPPLY M1674 FAILED CAPACITY CHECK REF JC 29-1012-1-5801. REPLACED BATTERY PACK FOR M1674 IAW AMM 33-51-06-960-805. CEILING PNL AT ENTRYWAY NEEDS TO BE INSTALLED AND CAPACITY CHECK NEEDS TO BE ACCOMPLISHED IAW AMM 33-51-06-200-801 SDR CALA2020053100995Battery Pack · dischargedAISLE EMERGENCY LIGHT AT ROW 29 AND 34 RIGHT SIDE DO NOT ILLUMINATE. REPLACED BATTERY PACK M2627 IAW AMM 33-51-06-960-805. BOTH LIGHTS OPERATIONS CHECK NORMAL..SDR CALA2020050200888Battery Pack · defectiveEMERGENCY ISLE PATH LIGHTING INOP ROWS 27-31 FOUND BATT PACK DEAD M2626 NOT CHARGING. RMVD AND REPLACED PER AMM 33-51-06 960-805 BATT PACK AND CHARGER ASSY/ W SVCBLE CHARGER D717-02-030 AND BATT PACK AD-D717-01-100. OPS OK.SDR CALA2020050200910Skin · crackedLH LOWER HORIZONTAL SKN REPAIR REQUIRED FOR ACCESS TO STA. 92.7 RIB REPAIRS AT STIFFENERS #1 AND #2. CUT OUT SKIN FOR ACCESS TO RIB REPAIR. FABRICATED AND IUNSTALLED REPAIR DOUBLER PER SRM 55-10-01,REPAIR 11. INITIATED DIP TO PERF ORM A DETAIL VISUAL AND EXTERSDR CALA2020050200909Skin · crackedLEFT HORIZONTAL STABILIZER LOWER SKIN AT STATION 147.00 IS CRACKED AT CENTER SECTION CLOSE TO DRAIN HOLE. CUT OUT DAMAGE SKIN AND INSTALLED REPAIR DOUBLER PER SRM 55-10-0 1,REPAIR 11. INITIATED DIP TO PERFORM A DETAIL VISUAL AND EXTERN AL LFEC INSPECTION AT 56SDR CALA2020050200908Skin Panel · crackedR/H HORIZONTAL STABILIZER LOWER IN-SPAR SKIN PANEL IS CRACKED AT STAB STA 157.1 APPROX 16" FROM AFT SPAR REPAIRED CRACKED SKIN REF SRM 55-10-01 REPAIR 11 SEE HANGER NON- ROUTINE 9740028. INITIATED DIP TO INSPECT REPAIR AT 56,000 FLIGH T CYCLES AND SUBSEQUENT 9SDR CALA2020050200893Skin · crackedRIGHT HORIZONTAL STAB LOWER SKIN AT STATION 120.30 HAS 2 CRACKS AT CENTER SECTION CLOSE TO DRAIN HOLE. CUTOUT DAMAGED SKIN AND INSTALLED REPAIR DOUBLER PER SRM 55-10-0 1 REPAIR 11. INITIATED DIP TO PERFORM DETAILED VISUAL AND LFEC I NSPECTION AT 56000 TOTAL FLSDR CALA2020050200892Skin · crackedRIGHT HORIZONTAL STAB. LOWER SKIN AT STA.111.10 IS CRACKED AT C ENTER SECTION,CLOSE TO DRAIN HOLE. MARKED CUT OUT DAMAGE SKIN AND INSTALLED DOUBLER PER SRM 55-10-01,REPAI R 11. INITIATED DIP TO PERFORM A DETAIL VISUAL AND EXTERNAL LFEC INSPECTON AT 56,000 FLIGSDR CALA2020050200891Stringer · corrodedSTRINGER 23 LEFT HAS CORROSION AND MISSING OR LOOSE PAINT FROM F RAME 295.5 TO 351 IN E&E COMPARTMENT. BLENDED OUT DAMAGE AREA AND INSTALLED REPAIR ANGLE PER EC/RA#531 0-07782,PART 1. INITIATED DIP TO "ACCOMPLISH INSPECTION REQUIREM ENTS ON OR BEFORE THE AIRCRSDR CALA2020042400874Battery · dischargedEMERGENCY LIGHTS IN INTERIOR INOP ALL SECTIONS EXCEPT THE OV WNG EXITS- NEEDS 12 EA PACKS AND BATTS NIS CLE. PACK EQUIP NUMBERS AS FOLLOWS- M1674/1675 FWD ENTRY M1676/M2503 MAIN BAIN F/C FWD STA 500 C/E. M1670/1671 MAIN CABIN MID AFT STA 727C/K M2626/2627 MAINSDR CALA2020042400868Battery Pack · dischargedEMERGENCY LIGHTS INOP. AISLE LIGHTS FROM ROW 22ABC TO 34ABC. OVHD LIGHTS IN SAME SECTION. EXTERIOR LIGHTS AT AFT LEFT OVERWING DOOR AND GRD LIGHT. REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK M1670 AND BATTERY PACK ON M2626 REF MM 33-51-06. OPS CK OK.SDR CALA2020042000857Battery Pack · dischargedMISC EMERGENCY SEAT PROXIMITY, AISLE AND INSIDE & OUTSIDE OVER WING EXIT LIGHTS INOP DURING TEST REMOVED AND REPLACED BATTERY FOR MODULE M1694 AND M1695. R/R M1671 AND BATT. R/ R M 2626. REFF MM 33-51-06-960-806, MM 33-51-06-960-806. M 2626, M 2503 AND M1676 RSDR CALA2020041000809Seat Track · corrodedCABIN SEAT TRACK LBL 45.50 HAS AREAS OF CORROSION IN CROWN SECTION BETWEEN STA. 500D & 500E (UNDER LAV "T") REF; FLEETCYCLE NR 9735418 REPLACED SECTION OF SEAT TRACK BETWEEN STA. 480 AND 500F REF. SRM 53-00-01 REPAIR 4 (UNDER LAV "T") REF; FLEETCYCLE NR 973541SDR CALA2020041000808Seat Track · corrodedCABIN SEAT TRACK LBL 24.75 HAS AREAS OF CORROSION IN CROWN SECTION BETWEEN STA. 500D & 500F(UNDER LAV "T") REPLACED SECTION OF SEAT TRACK BETWEEN STA. 480 AND 500F REF. SRM 53-00-01 REPAIR 4 (UNDER LAV "T") REF; FLEETCYCLE NR 9735416 SIGNIFICANT FINDINGS REPORSDR CALA2020040300787Light · inoperativeEMER EXIT LOCATOR SIGN JUST AFT OF DOOR 2RH INOP. REPLACED LIGHT ASSY REF AMM 33-51-01-960-802 OPS CHECKED OK. INSPECTED EMER LOCATOR SIGN REF ANN 33-51-01-960-802SDR CALA2020040300785Drain Line · leakingFO''S PITOT DRAIN TUBE IS LEAKING REF LP 4817950. REMOVED FO''S PITOT DRAIN TUBE FROM A/C FOR REPLACEMENT. VERIFIED REMOVED INSTALLED F/O PITOT TUBE REF AMM 34-11-01-400-801 UP TO AND INCLUDING STEP F (21). MUST PROCEED WITH STEP G INSTALLATION TEST ROTABLE PASDR CALA2020040300779Pressure Deck · crackedPRESSURE DECK VERTICAL WEB IS CRACKED AT STA.663 AND APPROX. RB L 34. INSTALLED REPAIR DOUBLER PER SRM 57-10-10,REPAIR 3,ALTERNATIVE 2 .INITTIATED DIP TO PERFORM HFEC AND LFEC INSPECTIONS AT 56,000 F LIGHT CYCLES AFTER REPAIR INSTALLATION AND REPEAT INSPECTIONSDR CALA2020033000755Unknown · malfunctionedFMC CLIMB PAGE WOULD NOT RECGONIZE FLAPS UP WITH AC SYSTEMS SHOW ING FLAPS UP BITE TEST OF FSEU SHOWED NO CURRENT FAULTS, LAST FAULT WAS 189 LEGS AGO. BITE TEST OF FMC,S SHOWED NO FAULTS. PERFORMED LAND VERIFY AND COMPLETE AUTO LAND TEST ALL TESTS PASSED. REF SDR CALA2020032700735Probe · defectiveLOST ALL TEMP AND PERFORMANCE DATA ON CLIMBOUT R&R TAT PROBE REF AMM 34-21-06.OPS CHECK NORMAL.PERFORMED LAND V ERY TEST.TEST PASSED.AIRCRAFT IS FULL AUTOLAND CAT CAPABILITY ISDR CALA2020032700734Light · inoperativeSEAT 20ABC EMER EXIT PATHWAY FLOOR ILLUM LIGHT INOP. RELAMPED REF AMM 33-51-11-960-801 OPS CHECKED OK. ACP''D IDT INSPECTION IAW GMM 09-10-05SDR CALA2020032700711Rib · damagedR/H LOWER HORZ SKIN AT STA 129.50 REQUIRES SKIN CUTOUT TO ACCESS RIB REPAIR AT #3 RIB VERTICAL STIFFENER. REF. F/C 9731226 AND F/C 9731183. FOR DIP REINSPECTION PURPOSES. REPAIRED PER SRM 55-10-01 REPAIR 11 REF. F/C N/R 9731226 FOR ALL WORK PERFORMED. PLACED OSDR CALA2020032700710Rib · damagedLH LOWER HORZ SKIN AT STA 101.90 REQUIRES SKIN CUTOUT TO ACCESS RIB REPAIR AT THE SECOND RIB STIFFENER. RER. F/C 9731274. FOR DIP REINSPECTION PURPOSES. REPAIRED PER SRM 55-10-01 REPAIR 11 REF. F/C N/R 9731274 FOR ALL WORK PERFORMED. PLACED ON DIP FOR INSPECTISDR CALA2020032700709Skin · crackedLEFT HORIZONTAL STAB LOWER SKIN CRACKED AT STA 147.90 6 INCHES FWD OF DRAIN HOLE. ENDS OF CRACK MARKED AND VERIFIED BY HFEC. REPAIRED PER SRM 55-10-01 REPAIR 11 REF. F/C N/R 9731201 FOR ALL WORK PERFORMED. PLACED ON DIP FOR INSPECTION PER SRM 55-10-01 REPAIR SDR CALA2020032700708Skin · crackedRIGHT HORIZONTAL STAB LOWER SKIN CRACKED AT STA 101.90 8 INCHES AFT OF DRAIN HOLE. ENDS OF CRACK MARKED AND VERIFIED BY HFEC. REPAIRED PER SRM 55-10-01 REPAIR 11 REF. F/C N/R 9731202 FOR ALL WORK PERFORMED. PLACED ON DIP FOR INSPECTION PER SRM 55-10-01 REPAIR SDR CALA2020032700707Skin · crackedLEFT HORIZONTAL STAB LOWER SKIN CRACKED AT STA 101.90 8 INCHES AFT OF DRAIN HOLE. ENDS OF CRACK MARKED AND VERIFIED BY HFEC. REPAIRED PER SRM 55-10-01 REPAIR 11 REF. F/C N/R 9731199 FOR ALL WORK PERFORMED. PLACED ON DIP FOR INSPECTION PER SRM 55-10-01 REPAIR
Back to Boeing 737-924ER