Boeing 757-222
Service difficulty reports · 15,539
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '757222' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010020300439Valve · failedSPAR VALVE AND ENG VALVE CAME ON AFTER ENGINE START AND FLAMED OUT (RT ENG). SPAR VALVE LIGHT ON PEDESTAL AND ENGINE VALVE LIGHT COME ON AFTER TURNING ON ENGINE ANTI-ICE. REPLACED NR 2 ENG SPAR VALVE. OPS CHECK GOOD.SDR UALA2010020300429Light · looseFLOOR EXIT LIGHTING STRIP LOOSE AT ROW 22. CLEAR COVERING. OP'S CHECK NORMAL.SDR UALA2010020200416Skin · damagedFOUND 3 LIGHTENING STRIKES ON FWD UPPER FUSELAGE, NR 1 AT STA 621, 1 INCH BELOW STR 4R, .100 INCH IN DIAMETER AND .020 INCH DEEP. NR 2 AT STA 626, 1-4 INCH BELOW STR 4R, .150 INCH IN DIAMETER AND .002 INCH DEEP. NR 3 AT STA 633,1-4 INCH BELOW STR 4R, .100 INCHSDR UALA2010020100399Control Rod · out of adjustFA'S REPORT THAT 2L WAS DIFFICULT TO ARM BUT SHOWS CORRECTLY ARMED. FOUND RIG TO RETRACTABLE DOOR OUT OF ADJUSTMENT AND BINDING. ADJUSTED CONTROL ROD.SDR UALA2010020100400Cover · looseEMERGENCY LIGHTING STRIP LOOSE BEHIND 34 ABC. SECURED EMERGENCY LIGHT STRIP COVER.SDR UALA2010020100395Light · inoperativeFOUND AFT IN FRONT OF LAV SMALL EGRESS LIGHTING STRIP NOT WORKING. REPLACED SMALL EMERGENCY LIGHT STRIP IN FRONT OF AFT FWD LAV DOOR. OK FOR SERVICE.SDR UALA2010020100404Wire · damagedAFT DRAIN MASK IS FROZEN. FOUND BURNED WIRES IN AFT PIT. DAMAGED WIRES ARE LOCATED ON RT SIDE, NEAR CEILING AFT OF AFT VENT LINE. APPROX STA NR 1697.7. OTBD OF WATER TANK. THERE ARE 6 WIRES DAMAGED. REPAIRED WIRES IAW SWPM. SEPARATE WU GENERATED FOR OPS CK SDR UALA2010020100396O-Ring · leakingNR 1 ENG HAS HYD FLUID LEAK UNDER FAN COWL. FOUND LWR INBD REVERSER ACTUATOR FLEX SHAFT TUBE LEAKING AT 'B' NUT. INSTALLED NEW O-RINGS AND PACKINGS. LEAK CHECKS NORMAL.SDR UALA2010020100386Fan Blade · nickedNR 2 ENG HAS NICKED ON FAN BLADE (MARKED WITH TAPE). ACCOMPLISHED BLADE REPAIR. NEED TO EDDY CURRENT REPAIR. ACCOMPLISHED HFEC PER MM. NO CRACK NOTED. ADDITIONAL .020 BLEND OUT REQUIRED PER MM. ACCOMPLISHED REPAIR OF BLADE IAW MM.SDR UALA2010020100384Drain Valve · openPOTABLE WATER ISSUE, FLT DIVERTED. FOUND OVERBOARD DRAIN VALVE AT SERVICE PANEL OPEN. CLOSED VALVE, SERVICED SYS. ALL OP'S GOOD COMPRESSOR INOP PRECAUTIONARY IAW OPBLM. BECAUSE ACFT DIVERTED FOR THE COMPRESSOR VIBRATION, REPLACE COMPRESSOR PRECAUTIONARY.SDR UALA2010012900375Floor Panel · delaminatedDURING REMOVAL OF FWD DRAIN MAST, FOUND THAT THE 2 AFT HOLES OF PANEL 193AL THAT ATTACHES DRAIN MAST TO PANEL ARE DAMAGED. PANEL IS DELAMINATED AND FILLER IS MISSING LEAVING A 6 INCH BY 4 INCH HOLE, DELAMINATED AREA IS 6 BY 10 INCHES. REMOVED FWD DRAIN MAST,SDR UALA2010012900374Light · inoperativeFOUND EMERGENCY EGRESS LIGHTING OUT AT FWD MID LAV DOOR. REPLACED EMERGENCY EGRESS LIGHTING STRIP IN FRONT OF MID LAV DOOR.SDR UALA2010012800359Structure · delaminatedNR 2 ENG REVERSER UPPER BI-FURCATION IS DELAMINATED. APPROX 300 SQUARE INCHES FWD END GOING AFT (MARKED) ACCOMPLISHED TIME LIMITED BACK SHEET REPAIR IAW MM-78-31-93. REPAIR INSTALLED MEASURES APPROX 280 SQ INCHES. IAW MM PG 803: REPAIR TO BE RE-CHECKED ATSDR UALA2010012800356Light · inoperativeEMERGENCY FLOOR LIGHT AT AFT LAV IS IN-OP. REPLACED EMERGENCY LIGHT SECTION AT AFT LAV. PCN 560-3325. OPS CHECKS GOOD.SDR UALA2010012800340Ground Wire · damagedFOUND G2B GALLEY COUNTER NOT GROUNDED. HOT PLATE INOP UNTIL GROUNDS FIXED. SUPPLEMENTAL DATA UPDATE PULLED AND COLLARED HOT PLATE CB. ALSO PULLED AND COLLARED G2B GALLEY CB ON P70 PANEL. NEEDS GD9095 & GD9074 CONNECTED TO GROUND. FOUND OPEN ON GROUND TO AIRFRASDR UALA2010012900378Lamp · inoperativeR1 DOOR EXTERIOR SLIDE EMERGENCY LIGHT IS INOP. RELAMPED R1 DOOR EXT SLIDE EMERGENCY LIGHT AND OPS CHECK.SDR UALA2010012900376Lamp · inoperativeR2 DOOR EXTERIOR EMERGENCY LIGHT IS INOPERATIVE. LAMP FOUND DEFECTIVE. RELAMPED R2 DOOR EXIT LIGHT. OPS CHECK OK.SDR UALA2010012800355Wire · damagedEMERGENCY LIGHT WIRES CUT ON WALL ACROSS FROM 1L CLOSET. NEED TO HAVE FEMALE PLUG SPLICED TO BE ABLE TO CONNECT NEW EMERGENCY LIGHT THAT WAS INSTALLED. CUT IS IN FLAT WIRE, WILL NEED NEW LIGHT ASSY. PARTS NEEDED 5879-1 AND 5863-1 LEAD IN CABLE. REPAIRED EMERSDR UALA2010012800344Charger · inoperativeEMERGENCY SLIDE ILLUMINATING LIGHT AT DOOR 2R IS INOP. ALSO EMERGENCY FLOOR STRIP IN FIRST CLASS IS INOP. REMOVED AND REPLACED EMERGENCY BATTERY CHARGER ABOVE R2 DOOR AND OPS CHECK LIGHT.SDR UALA2010012700324Bearing · damagedR MED NR 4 RT BODY TORQUE TUBE BEARING BROKEN. PART OF BEARING STUCK IN CAM PLATE, PART OF BEARING STUCK ON BODY TORQUE TUBE. (LOWER MOST BEARING) CHECKED MED 4 RT AND FOUND SAFE FOR FERRY FLIGHT. REPLACED BEARING. REINSTALLED BODY TORQUE TUBE. OPS CHECK OK.SDR UALA2010012800342Ground Wire · looseF/A RECEIVED SHOCK FROM TOUCHING METAL IN MID GALLEY. DEACTIVATED MID FWD GALLEY BOTH COFFEEMAKERS & MID FWD GALLEY COFFEE WARMER, NO SHOCK FELT. BOTH COFFEEMAKERS COLLARED. FOUND G2A GALLEY COUNTER & G2B GALLEY COUNTERS NOT GROUNDED. FOUND G2A COUNTER AT 36SDR UALA2010012700336Connector · damagedFROM AISLE ROW 9C BACK TO MID CABIN EMERGENCY LIGHT STRIP INOPERATIVE. REPAIR POWER CONNECTOR, CHECKS NORMAL.SDR UALA2010012700335Exhaust Valve · faultyOVERBOARD EXHAUST VALVE TEST STATUS MESSAGE. REPLACED EQUIPMENT COOLING OVERBOARD EXHAUST VALVE. OP CKS NORMAL.SDR UALA2010012700331Pdu · faultedNR 2 ENG EICAS MSG ENG SEC CONT DISPLAYED. REPLACED NR 2 ENG EEC ALTERNATOR STATOR. MSG STILL RETURNS. WIRING CHECKED GOOD. REPLACED PDIU M10553 PER AMM. NO MESSAGES PRESENT.SDR UALA2010012700330Cover · damagedEMERGENCY FLOOR LIGHTING BUCKLED ROW 9-15. REPAIRED EMERGENCY LIGHT COVER.SDR UALA2010012700325Socket · faultyLAV 3L MIRROR LIGHT INOP. NEED NEW LAMP SOCKET. CHANGED LAMP SOCKET, OPS CHECKED OK.SDR UALA2010012600323Scavenge Pump · leakingNR 2 ENGINE REQUIRED 8 QUARTS UPON ARRIVAL. ENG LEAK CHECK REVEALED A HOLE IN OIL PUMP CASE. REMOVING PUMP AWAITING PART, 615-9009 ON AOG K6781. REPLACED LUBE AND SCAV PUMP. RAN ENG AND ADJUSTED THE PRES TRIM VALVE. OPS ARE NORMAL.SDR UALA2010012600317Skin · gougedLT WING OTBD FLAP UPPER SKIN GOUGED WS 460. UPDATE FLAP SKIN SUSTAINED DAMAGE. REMOVED AND REPAIRED LT WING OTBD FLAP UPPER SKIN PANEL. REINSTALLED FLAP SKIN PANEL.SDR UALA2010012600322Lamp · inoperative1L SLIDE LIGHT WILL NOT ILLUMINATE WHEN SLIDE IS ARMED. RELAMPED, CHECKS OK.SDR UALA2010012600316Skin · wornRT WING INBD FORE FLAP, UPPER SKIN WORN AT NR8 SPOILER. REPAIRED DAMAGE IAW REO-G13193. THE REPAIR IS A MAJOR REPAIR IAW UA SRM. IT RECEIVED STAGE 1 APPROVAL VIA FAA FORM 8100-9, DATED 20JAN10. A NEW FAA FORM 8100-9 MUST BE ISSUED WITHIN 24 MONTHS FROM 20SDR UALA2010012600315Panel · chafedLT WING INBD FLAP PANEL, OTBD UPPER SURFACE CHAFED. ACP REPAIR IAW REO-G13194. THE REPAIR IS MAJOR REPAIR IAW SRM AND UA EVA 73321, THE REPAIR HAS RECEIVED STG 1 APPROVED VIA FAA FORM 8100-9. CONTINUE, 24 MONTHS FROM 20JAN10 DTA 10-002 HAS BEEN CREATED TO TRSDR UALA2010012600314Proximity Sensor · faultyDOOR 4R SLIDE LIGHT INOPERATIVE. REPLACED FWD PROX SENSORS 10224, OPS CK GOOD.SDR UALA2010012500313Control Valve · faultyLEFT PACK OFF LIGHT AND EICAS MESSAGE NOT ON WITH PACK SELECTED OFF, IAW CREW. REPLACED FLOW CONTROL AND SHUTOFF VALVE. OPS GOOD.SDR UALA2010012500296Control Panel · intermittentRT ENG SQUIB FAILURE, RTFL. ACCOMPLISHED MEL 2620J. FOUND SQUIB OK. CONTROL PANEL SWITCH NR 2 INTERMITTENT. VERIFIED FAULT. REPLACED TEST PANEL. OP CKS GOOD.SDR UALA2010012500295Guide Arm · bindingDOOR 1R BINDS WHEN OPENING. HINGE ARM FOUND TO BE CONTACTING GUIDE ARM. ADJUSTED SERRATED PLATE AND GUIDE ARM. DOOR OPS GREAT.SDR UALA2010012500291Connector · unsecureFLOOR EMERGENCY LIGHT STRIP UNPLUGGED LAST ROW OF ECONOMY CABIN. FOUND PLUG UNSECURE. SECURED EMERGENCY LIGHT STRIP PLUG, OPS TEST OK.SDR UALA2010012500289Charger · inoperativeAFT COACH EMERGENCY LIGHT STRIP HAS BROKEN PINS. REMOVED AND REPLACED AFT COACH EMERGENCY LIGHT STRIP. REMOVED AND REPLACED BATTERY CHARGER M10817, OPS CHECK GOOD.SDR UALA2010012500288Slide · out of toleranceR2 DOOR SLIDE LACING PULLED LOOSE AT GIRT BAR. SLIDE FOUND UNDERSERVICED. REMOVED AND REPLACED SLIDE PACK.SDR UALA2010012500287Light · faultyFIRST CLASS FLOOR EMERGENCY LIGHTS HAS 3 HALF LIT LIGHT STRIP. REMOVED AND REPLACED EMERGENCY LIGHT IN FIRST CLASS AREA AND OPS CHECK GOOD.SDR UALA2010012500286Light · faultyEMERGENCY FLOOR LIGHT AT FWD CLOSET IS TOO SHORT. REMOVED AND REPLACED EMERGENCY LIGHT AT FWD CLOSET. OPS CHECKS GOOD.SDR UALA2010012500285Sequence Valve · failedNLG DID NOT EXTEND IN FLT. RAN ALT EXTEND CHECKLIST & GOT GREEN LIGHTS. NORMAL LANDING. REPLACED NLG SEQUENCE VALVE. AFTER REPLACEMENT OF SEQUENCE VALVE ACCOMPLISHED NOSE GEAR EXTENSION AND RETRACTION TEST NUMEROUS TIMES AND GEAR. OPS CHECKED NORMAL. NO LSDR UALA2010012500290A/C Pack · odorPACKS PUT OUT STRONG MUSTY ODOR WHEN FLYING IN MOISTURE. SEE HISTORY. ACCOMPLISHED ENG RUN OIL LEAKAGE EXTERNAL FROM REV COWL OPEN ACT REF LM3422 AND CREATED SMC08. SECOND RUN NEEDS TO BE ACCOMPLISHED REF SMC08.SDR UALA2010012500283Engine · bird ingestionBIRDSTRIKE AT ROTATION ON TAKEOFF, RT ENG ODOR IN COCKPIT & CABIN. NOTED HIGH VIBRATION LEVEL (33.0) AT CLIMB PWR. ACCOMPLISHED BIRDSTRIKE INSP. ACP INSP OF EXHAUST AREA, 10TH AND 14TH STAGE BLEED DUCTS ON METAL FOUND (PB 10). BORESCOPED 6TH STG COMP IAW MM NSDR UALA2010012500280Light · inoperativeMID COACH EMERGENCY LIGHT STRIP PARTIALLY INOP (BENT). REMOVED AND REPLACED COACH EMERGENCY LIGHT STRIP REF MM 33-51-11. WORK IS ACP ON NR 27414.SDR UALA2010012500279Piston · damagedMAIN CABIN R1 DOOR EMERGENCY POWER SPRING CYLINDER PISTON DOES NOT HAVE RED BAND VISIBLE. ADJUSTED EMERGENCY POWER SPRING CYLINDER PISTON. ADJUSTED EMERGENCY POWER SPRING CYLINDER PISTON.SDR UALA2010012200272Eec · faultyNR 1 ENG WITH EEC MAINT POWER SELECT SWITCH IN ALTN POSITION. EPCS PAGE DISPLAYS NO CHANNEL SELECTED. CHANNEL SELECT SWITCH HAS NO EFFECT. SQUARE BOX AROUND PRI, SEC, NOT DISPLAYED. THRUST REV WILL NOT DEPLOY. REPLACED EEC. PROBLEM STILL PERSISTS. REPLACEDSDR UALA2010012100262Floorboard · faultyFLOORBOARD IN MIDDLE OF AISLE BETWEEN ROW 7 & 8 SPONGY. INSTALLED TEMP SHEETMETAL REPAIR. REPLACED FLOOR PANEL.SDR UALA2010012000245Smoke Goggles · faultyCAPT AND OBSERVER'S SMOKE GOGGLE BANDS HAVE NO ELASTICITY. GOGGLES FOUND FAULTY. REPLACED BOTH GOGGLES.SDR UALA2010012000243Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED AT STA 365 RBL 60. MAJOR REPAIR ACCOMPLISHED: REPAIRED FLOORBEAM AT STA 365. REMOVED DAMAGE AND REINSTALLED SUPPORT STRUCTURE.SDR UALA2010012000242Torque Tube · gougedMAIN CABIN DOOR 4L, BODY TORQUE TUBE HOLD OPEN COLLAR GOUGED. REMOVED AND REPLACED L4 DOOR TORQUE TUBE HOLD OPEN COLLAR.
Back to Boeing 757-222