SDR UALA2013070204603Scuff Plate · tornAFT CARGO DOOR LOWER SILL SCUFF PLATE IS TORN. FOUND DAMAGE WITHIN ALLOWABLE LIMITS. PERFORMED INTERIM REPAIR IAW ECRA 5310-04203, PART 1. REQUIRES DAILY INSPECTION OF REPAIR IAW PART 2.SDR UALA2013070204602Actuator · leakingHYDRAULIC FLUID LEAKING FROM LT ENGINE. OTBD UPPER REVERSER ACTUATOR LEAKING BEYOND LIMITS.SDR UALA2013070104590Audio Panel · contaminatedCAPTAIN`S AUDIO CONTROL PANEL CONTAMINATED. REPLACED CAPTAIN`S AUDIO SELECT PANEL IAW AMM.SDR UALA2013070204634Cap · missingEMERGENCY LIGHT END CAP NOT INSTALLED NEAR SEAT 40C. REPLACED MISSING END CAP.SDR UALA2013070204635Cap · missingEMERGENCY LIGHT END CAP MISSING AT SEAT 6A & 1B. REPLACED END CAP.SDR UALA2013070204623Floorbeam · corrodedFLOORBEAM, BS 1640, LBL 10 - RBL 56 HAS SPOTS OF CORROSION. FLOORBEAM REPAIRED IAW SRM 53-00-01. REPAIR 10.SDR UALA2013070104593Bonding Strap · brokenPC AIR ACCESS DOOR BONDING STRAP BROKEN. REPLACED STRAP.SDR UALA2013070204617Engine · leakingF/O POINTED OUT OIL LEAKING FROM NR 2 ENGINE, FOUND OIL LEAKING OUT OF 2.5 BLEED PORT, ON FURTHER INSPECTION WITH BOROSCOPE, FOUND OIL RUNNING DOWN INSIDE OF ENGINE AT THE SEAM. SUSPECT IT IS A LEAK FROM THE NR 2 MAIN BEARING CARBON SEAL.SDR UALA2013070104595Window Shade · broken7A WINDOW SHADE ASSY BROKEN.SDR UALA2013070104592Bottle · low pressureL2 DOOR SLIDE BOTTLE CHARGE LOOKS AS IF IT IS IN THE RED. REPLACED 2L SLIDE IAW AMM, OPS CHECKED GOOD.SDR UALA2013070104589Handle · bindingCAPTAIN`S SLIDING WINDOW HANDLE STUCK IN LOCKED POSITION. FOUND AFT WINDOW TRACK TRIM STUCK. REPOSITION TRIM. CAPTAIN SLIDING WINDOW HANDLE, OPS NORMAL. OK TO CONTINUE.SDR UALA2013070104588Signal Cond Unit · faultyRIGHT ENGINE VIBRATION INDICATION READS HIGH, LOW, ZERO, BLANK, FLUCTUATES OR INOPERATIVE. NO ABNORMAL VIBRATION PERCEIVED. OTHER ENGINE PARAMETERS NORMAL. REPLACED AIRBORNE VIBRATION MONITOR SIGNAL CONDITIONER IAW AMM.SDR UALA2013070104587Lanyard · unsecureLANYARD HANGING FROM SLIDE PACK AT DOOR 2L. STOWED LANYARD AT SLIDE PACK AT DOOR 2L.SDR UALA2013070104586Fuel/Oil Cooler · leakingNR 1 ENGINE IS LEAKING MORE THAN 60 DROPS PER MINUTE FROM DRAIN MAST NR 5, FUEL OIL COOLER-OIL SCUPPER IAW AMM 71-71-00. REPLACED FUEL-OIL HEAT EXCHANGER IAW AMM AND FUEL-OIL HEAT EXCHANGER BYPASS VALVE.SDR UALA2013070104585Indicator · faultyCOCKPIT AND WING FUEL PANELS HAVE NO POWER, FUEL QTY BITE STATUS MESSAGE ON EICAS. REPLACED FQIS PROCESSOR DUE TO SEVERAL FAULTS. FOUND RT WING QTY GAUGE SHORTED. REPLACED RT FUEL QTY INDICATOR AT REFUELING PANEL AND OPS CHECKED GOOD.SDR UALA2013070104564Filter · odorBURNING ODOR IN CABIN AND COCKPIT DURING CRUISE AT FL370. TURNED RT RECIRCULATION FAN OFF, ODOR GONE. REPLACED RT AND LT RECIRCULATION FAN FILTERS IAW MM-21-25-02 AND ACCOMPLISHED CHECK, IAW MM-21-00-01 OPS CHECKED NORMAL. NO ELECTRICAL ODOR NOTED.SDR UALA2013070204616Wire · brokenNO MAIN BATTERY VOLTS DISPLAYED ON EICAS ELEC PAGE. BROKEN WIRE FROM D40246P TO D40904P, REF WD 24-34-11. ACCOMPLISHED WIRING INTERIM REPAIR IAW ECRA 2434-01044. BATTERY VOLTAGE DISPLAYS CORRECTLY ON EICAS.SDR UALA2013070104556Floor Panel · corrodedAFT CABIN UPPER FLOOR DECK PLATE AT BS 1681 CORRODED FROM LBL 11 TO RBL 61. REPAIR UPPER DECK PLATE IAW ECRA 5330-04259 REPAIR 2.SDR UALA2013070104565Cover · unsecurePAX & CREW TRIPPING ON SEAM OF RUBBER FLOORING-CARPET BY MID GALLEY. SURFACE NOT SMOOTH. REMOVED STRIPPING AT FWD AND AFT ENDS OF MID GALLEY FLOOR MAT AND INSTALLED DOUBLE BACK TAPE AND CLEAR MYLAR OVER IAW ECRA 2533-01004 AND TRM 25-33-01-004.SDR UALA2013070104563Girt Bar · obstructedR1 DOOR WILL NOT ARM. FOUND R-1 DOOR STATIC LINE EXCESS LENGTH INTERFERS WITH GIRT BAR LATCH STOWED LINE. DOOR ARMS NORMAL, ALL OPS NORMAL.SDR UALA2013070104562Seat · brokenCONTROLS AND WIRING HANGING OUT AT SEAT 20C. ARMCAP AT SEAT 20C ATTACH POINT BROKEN. REPLACED ARM REST CAP.SDR UALA2013070104555Floorbeam · corrodedMAIN CABIN STA 324, RBL 42 FLOORBEAM UPPER SURFACE HAS AREAS OF CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED FLOORBEAM UPPER FLANGE CORROSION, FOUND OUT OF LIMITS. INSTALLED FLOORBEAM UPPER CHORD SPLICE REPAIR AND PARTIAL UPPER CHORD REPLACEMENT AT STA 324 SDR UALA2013070104554Skin · dentedLT EXTERIOR SKIN STA 1700+10, 3" BELOW STR 25L DENTED. EVALUATED AND FOUND THAT THE DAMAGE REQUIRES REPAIR . CUT OUT DENT AND REPAIRED IAW ECRA 5360-01316. SKIN HAS BEEN REPAIRED AT BS 1710 JUST ABOVE S-26 IAW ECRA 5360-01316 TO STAGE 1 & 2 STANDARDS. A NEW FSDR UALA2013070104553Floorbeam · corrodedWHILE WORKING BS 1681, FLOORBEAM, CORROSION WAS FOUND AT BS RBL 45 AND 55 UNDER FWD SIDE OF BEAM UPPER FLANGE. CORROSION IS 100 PERCENT MATERIAL LOSS. REMOVED PART IAW SRM 51-40-02. FAB NEW PART REF WO27297-2400-0199 FROM BAC 1518-347-7075-T65U AND ANODIZED SDR UALA2013062804530Floor Support · crackedMAIN CABIN FLOOR SUPPORT CRACKED AROUND FASTENER HOLES BS 1520 TO 1540 BL 0. LOCATED AND FABBED NEW UPPER ATTACH ANGLE AND SHIM FOR MAIN CABIN FLOOR SUPPORT IAW DWG 140N2505 AND SRM 53-00-51, REPAIR 4, FIG 201. MAJOR REPAIR.SDR UALA2013062804533Floorbeam · damagedSCRIBE MARK DAMAGE ON CABIN FLOORBEAM AT BS 1600 RBL 27-43. REPAIRED DAMAGE ON CABIN FLOORBEAM .SDR UALA2013062804532Attach Bracket · corrodedMAIN CABIN, BS 1140, S17R CUSP WEB ATTACH BRACKET HAS CORROSION BS 1140 STR 17R. SUP: REPAIR IN COMPLIANCE WITH NON ROUTINE, NR 20452, REMOVED CORROSION ON MAIN CABIN CUSP WEB ATTACH BRACKET AT BS 1140 STR 17R ORIGINAL MAT THICKNESS OF .063IN MAT REMOVED IS 00SDR UALA2013062804545Actuator · faultyAPU DOOR STATUS MESSAGE, APU FAULTED. FOUND APU INLET ACTUATOR CIRCUIT BREAKER IN AFT BAY OPEN, RESET, OPENED APU DOOR FULLY. APU OIL LEVEL GOOD, 1 QT ADDED. CIRCUIT BREAKER TRIPPED TWICE ON SHUTDOWN WHEN DOOR CLOSING. SUSPECT ACTUATOR, REPLACED APU DOOSDR UALA2013062804531Floorbeam · corrodedMAIN CABIN BS 1681, LBL 52 FLOORBEAM ANGLE HAS CORROSION BS 1681, LBL 52. REPAIR IN COMPLIANCE WITH NON ROUTINE NR 20419. R & R ANGLE IAW SRM 51-40-02, PAR 7, FIG 12. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101. REMOVED AND REPLACED MAIN CABSDR CALA2013082790804Retaining Clip · damagedEXIT LIGHT LENS RETENTION CLIPS DAMAGED OVER DOOR 2L. REINSTALLED SIGN.SDR UALA2013062704491Reveal · missingWINDOW REVEAL AT SEAT ROW 20ABC MISSING. REPLACED WINDOW REVEAL AT PAX SEAT 20A.SDR UALA2013062704499Fan · noisyCOMMUNICATION IMPOSSIBLE WITH RT RECIRCULATION FAN ON. REPLACED RT RECIRCULATION FAN, OPS CHECKED OK. NO LEAKS NOTED.SDR UALA2013062704500Warning Message · illuminatedC HYD ELEC 1 EICAS DISPLAYED. LOW PRESSURE LIGHT ALSO ILLUMINATED ON OVERHEAD PANEL. OPS NORMAL.SDR UALA2013062704496Wire · brokenF/O'S HAND MICROPHONE INOPERATIVE. FOUND BROKEN WIRE AT HANDSET JACK, REPAIRED, OPS OK.SDR UALA2013062704492Connector · shortedRIGHT FWD OVERWING EMERGENCY LIGHT INOPERATIVE. NO POWER TO TERMINALS AT LIGHT ASSY. FOUND CONNECTOR MISSING GROUND, CONNECTOR SHORTED TO GROUND. SECURED GROUND WIRE, OPS CHECKED OK IAW WDM 33-51-13.SDR UALA2013062704490Control Panel · damagedFLIGHT DECK WET WITH HIGH HUMIDITY. REPLACED VHF COMM 1 & 2 CONTROL PANELS IAW AMM. REPLACED ADF CONTROL PANEL IAW AMM. REPLACED RT EFIS CONTROL PANEL IAW AMM. REPLACED ILS CONTROL PANEL IAW AMM. UNITS REPLACED DUE TO FOGGING IN DISPLAYS. ALL TEST REFERENCSDR FDEA201306261399Angle · corrodedBS 1635, S7L DOOR UPPER SILL INBD ANGLE FOUND CORRODED. REPAIRED IAW EA F-5310-T0301642, PART 1.SDR UALA2013062604440Fan · noisyLEFT RECIRCULATION FAN HAD A LOUD BEARING NOISE WHILE RUNNING. SELECTED OFF AND NOISE DISSIPATED. REPLACED LT RECIRCULATION FAN.SDR UALA2013062604439Strut · out of adjustNOSE WHEEL HAS A VERTICAL OSCILLATION DURING TAXI ABOVE 10 KNOTS. FOUND STRUT "X" DIMENSION HIGH, ADJUSTED TO PROPER LEVEL IAW AMM 12-51-02.SDR UALA2013062604434Floorbeam · corrodedFLOORBEAM BS 365, RBL 5.5 TO RBL 63 MULTIPLE AREA CORRODED. REPAIRED FLOORBEAM IAW ECRA 5310-05536. HFEC OF CUTOUT AND FASTENER HOLES, NO DEFECT NOTED. REPAIR IS STRUCTURALLY ACCEPTABLE AS CAT A AS DEFINED IN SRM 51-00-06.SDR UALA2013062704498Fan · inoperativeDURING PRESSURIZATION, LT RECIRCULATION FAN INOPERATIVE AND EICAS MESSAGE SHOWED INTERMITTENTLY. REPLACED LT RECIRCULATION FAN IAW MM, OPS AND LEAK CHECKED OK.SDR UALA2013062604435Floorbeam · corrodedFWD CABIN FLOORBEAM AT BS 365 FROM BL 0 TO RBL 56 CORRODED. REPAIRED FLOORBEAM LBL 12 TO RBL 65 IAW ECRA 5310-05536. HFEC CUTOUT & FASTENER HOLES, NO DEFECT NOTED. REPAIR IS STRUCTURALLY ACCEPTABLE AS CAT A REPAIR AS DEFINED IN SRM 51-00-06. MAJOR REPAIR.SDR UALA2013062604425Connector · burnedSMOKE REPORTED IN CABIN. WHILE TROUBLESHOOTING LOG 1 FOUND GALLEY 1 ANR 2 OVEN CONNECTOR YSAD2 POS 3 BURNED. REPLACED NR 2 OVEN.SDR UALA2013062604441Lamp · inoperativeRIGHT OVERWING AFT EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP, CHECKED GOOD.SDR UALA2013062604428Actuator · leakingNR 1 ENGINE ACCUMULATED A LARGE PUDDLE OF HYD FLUID ON GROUND IN LESS THAN 30 MINS. RAN THRUST REVERSER AND FOUND ACTIVE LEAK COMING FROM ROD END OF INBD CENTER ACTUATOR. STARTED REMOVAL AND INSTALLATION IAW AMM.SDR UALA2013062604429Actuator · leakingPUSH CREW NOTICED HYD FLUID UNDER LEFT WING NEAR AILERON ON WALKAROUND WITH HYD PRESSURIZED. AILERON PCA REPLACED. NO LEAKS NOTED.SDR UALA2013062604427Plate · crackedFWD CARGO BAY THRESHOLD PLATE HAS ONE PREVIOUSLY WELD REPAIR THAT IS CRACKED. STOP DRILLED ONE INCH CRACK IAW ECRA 5310-04203. FILLED CRACK WITH SEALANT APPLIED ALUMINUM TAPE OVER CRACK.SDR UALA2013062604426Blade · damagedNR 1 FAN BLADE ON RT ENGINE HAS NICK NEAR THE TIP. INSPECTED AND REPAIRED NR 1 ENG FAN BLADE IAW MM.SDR UALA2013062704497Module · faultyFUEL CONTROL PANEL ASSY SWITCH S5 FAILED. CMM 28-41-71, PG 1005, FUNCTIONAL TEST STAT 48 AND 51. RESISTANCE TOO HIGH. REF COA 507225, STEP 1A2-4. R & R S5 SWITCH MASTER MODULE. ACCOMPLISHED FUNCTIONAL TEST IAW CMM, CHECKS GOOD.SDR UALA2013062404379Door · brokenFLT DIVERTED. AIRFRAME VIBRATION CAN BE FELT THROUGHOUT THE CABIN AND IN FLT DECK ESPECIALLY AT FLOOR AREA. CHANGING AIRSPEED AND ALTITUDE-NO HELP. FEELS LIKE CONTINUAL LIGHT TURBULENCE WITH NONE REPORTED IN AREA, F/A REPORTS NORMAL WING APPEC. FELT MORE
Back to Boeing 757-222