Boeing 757-2B7
Service difficulty reports · 3,730
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572B7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA060108Skin · damagedSTA 222 S-29R BURN MARK. INSTALLED FASTENERS IAW SRM 53-00-01, SEC 1 PAR 3, DEFECT SIZE: .125 INCH.SDR USAA060107Skin · damagedSTA 370 AND S24R BURN MARK. INSTALLED RIVET IAW SRM 53-00-01, DEFECT SIZE: .125 INCH.SDR USAA060106Skin · damagedSTA 656 AND S24R BURN MARK. INSTALLED RIVET IAW SRM 53-00-01 REPAIR 6, DEFECT SIZE: .125 INCH.SDR USAA060112Skin · damagedSTATION 492 STRINGER 25 AND 26 DAMAGED. INSTALLED RIVET IAW SRM 53-00-01 SECTION ONE PAR 3, DEFECT SIZE: .125 INCH.SDR USAA060020Floorbeam · corrodedFOUND FLOORBEAM CORRODED STA 1640 BETWEEN LBL 60 TO RBL 60 ON FLOORBEAM. REPAIRED PER EA NR 97242, DEFECT SIZE: 2" BY 2" BY .060", 12" BY 2" BY .060", 12" BY 2" BY .050", 2" BY 2" BY .040".SDR USAA060025Unknown · corrodedFOUND CORROSION MAIN CABIN, BS 1711-1718, LBL 2-10, BS 1719-1715 LBL 13-22, 2725-1718 LBL 25-. REPLACED 3 G-4-B GALLEY DRAIN PAN COMPARTMENT BASES PER EA 86451A, FINAL REPAIR, DEFECT SIZE: 7.7 BY 8.0 BY .117", 8.3 BY 4.0 BY .108" BY 7.0 BY 3.0 BY .112".SDR USAA060024Support · corrodedFOUND CORROSION AFT CARGO DOOR SILL BETWEEN FS 1380-1410 STR 26. REMOVED AND REPLACED PRT PER SRM 53-00-53, 51-40-02, 52-20-01; CORROSION TASK C5315602.SDR USAA060023Support Angle · corrodedFOUND SUPPORT ANGLE CORRODED, STA 1460 STR 27L. FAB'D SUPPORT ANGLE PER SRM 51-40-02, 51-40-05; CORROSION TASK NR C53-155-02, DEFECT SIZE: 2"L BY 1/2"W BY .020"D.SDR USAA060021Support · corrodedFOUND CORROSION AROUND FASTENER HOLES, L4 DOOR STA 1660-1680, LBL APPROX 55. REMOVED SILL SUPPORT AND FAB NEW SUPPORT PER SRM 51-40-02, 53-00-04, DEFECT SIZE: .500 RADIUS BY .025 DEEP.SDR USAA060019Stringer · corrodedFOUND STA 1470 RBL 2, 7 AND LBL 16,7,11. CUT OUT DAMAGE SECTIONS OF STRINGER, FAB'D AND INSTALLED REPAIR ANGLES PER SRM 53-00-53, 51-70-11 AND EA, DEFECT SIZE: .250 CIRCUMFERENCE AROUND FASTENER HOLE (6 PLACES) BY .051 DEPT.SDR USAA060022Transition Panel · corrodedFOUND CORROSION STA 1300-1400 STR 27L AND STA 1200-1300 STR 27L. FAB'D NEW PART PER SRM 51-21-01, 53-00-53; STA 1200-1400 BLENDED AREA AND PRIMED. CORROSION TASK NR C5315502, DEFECT SIZE: 4" L BY 3"W BY .007"D AND 4"L BY 3"W BY .003"D.SDR USAA0620Floorbeam · corrodedSTA 1640 BETWEEN LBL 60 TO RBL 60 ON FLOORBEAM CORRODED. REPAIRED PER EA 97242, DEFECT SIZE: 2" X 2" X .060", 12" X 2" X .060", 12" X 2" X .050", 2" X 2" X .040".SDR USAA0625Pan · corrodedMAIN CABIN, BS 1711-1718, LBL 2-10, BS 1719-1715 LBL 13-22, 2725-1718 LBL 25 CORROSION. REPLACED 3 G-4-B GALLEY DRAIN PAN COMPARTMENT BASES PER EA 86451A, FINAL REPAIR, DEFECT SIZE: 7.7 X 8.0 X .117", 8.3 X 4.0 X .108" X 7.0 X 3.0 X .112", 7.7.SDR USAA0624Support · corrodedAFT CARGO DOOR SILL BETWEEN FS 1380-1410 STR 26 CORRODED. REMOVED & REPLACED PRT PER SRM 53-00-53, 51-40-02, 52-20-01; CORROSION TASK C5315602.SDR USAA0623Support Angle · corrodedSTA 1460 STR 27L CORRODED. FAB'D SUPPORT ANGLE PER SRM 51-40-02, 51-40-05; CORROSION TASK C53-155-02, DEFECT SIZE: 2"L X .5"W X .020"D.SDR USAA0621Support · corrodedAROUND FASTENER HOLES, L4 DOOR STA 1660-1680, LBL APPROX 55 CORRODED. REMOVED SILL SUPPORT & FAB NEW SUPPORT PER SRM 51-40-02, 53-00-04, DEFECT SIZE: .500 RADIUS X .025 DEEP.SDR USAA0619Stringer · corrodedSTA 1470 RBL 2, 7 & LBL 16, 7, 11 CORRODED. CUT OUT DAMAGE SECTIONS OF STRINGER, FAB'D & INSTALLED REPAIR ANGLES PER SRM 53-00-53, 51-70-11 & EA, DEFECT SIZE: .250 CIRCUMFERENCE AROUND FASTENER HOLE (6 PLACES) X .051 DEPT.SDR USAA0622Transition Panel · corrodedSTA 1300-1400 STR 27L & STA 1200-1300 STR 27L CORRODED. FAB'D NEW PART PER SRM 51-21-01, 53-00-53; STA 1200-1400 BLENDED AREA & PRIMED. CORR TASK C5315502, DEFECT SIZE: 4"L X 3"W X .007"D & 4"L X 3"W X .003"D.SDR USAA06000BFloor Support · corrodedLOCATION: STA 1660-1680, RBL APPROX. 55 ACTION: REMOVED & REPLACED WITH NEW SUPPORT (FLOOR) PER SRM 53-00-51, 51-40-05, 51-21-01, DEFECT SIZE: 20"L X 2"W X .020"DSDR USAA06000AClip · corrodedLOCATION: STA 1670-1680 ACTION: REMOVED & REPLACED WITH NEW FLOOR SUPPORT (CLIP) PER SRM 53-00-51, 51-10-02, 51-40-05, 51-20-01 DEFECT SIZE: 5.40"L X 2.40"W X .069"DSDR USAA060003Cargo Track · corrodedFOUND TIE DOWN FITTING CORRODED STA 1200-1640, AFT CARGO RT FLOOR. REMOVED CORROSION, INSPECTED, REPLACED OUT OF LIMIT TIE DOWN FITTINGS PER SRM 51-40-02, EA 97241, DEFECT SIZE: 2"L BY 1"W.SDR USAA060004Cargo Track · corrodedTIE DOWN FITTING CORRODED STA 1200-1640 AFT CARGO LT FLOOR TIE DOWN FITTINGS. REMOVED CORROSION, INSPECTED PER SRM 51-10-02, EA 97241, DEFECT SIZE: 2"L BY 1"W.SDR USAA062Floor Support · corrodedSTA 1660-1680, RBL APPROX 55 CORRODED. REMOVED & REPLACED WITH NEW SUPPORT (FLOOR) PER SRM 53-00-51, 51-40-05, 51-21-01, DEFECT SIZE: 20"L X 2"W X .020"D.SDR USAA061Clip · corrodedSTA 1670-1680 CORRODED. REMOVED & REPLACED WITH NEW FLOOR SUPPORT (CLIP) PER SRM 53-00-51, 51-10-02, 51-40-05, 51-20-01, DEFECT SIZE: 5.40"L X 2.40"W X .069"D.SDR USAA063Cargo Track · corrodedSTA 1200-1640, AFT CARGO RT FLOOR TIE DOWN FITTINGS CORRODED. REMOVED CORROSION, INSPECTED, REPLACED OUT OF LIMIT TIE DOWN FITTINGS PER SRM 51-40-02, EA 97241, DEFECT SIZE: 2"L X 1"W.SDR USAA064Cargo Track · corrodedSTA 1200-1640 AFT CARGO LEFT FLOOR TIE DOWN FITTINGS CORRODED. REMOVED CORROSION, INSPECTED PER SRM 51-10-02, EA 97241, DEFECT SIZE: 2"L X 1"W.SDR USAA051Clip · corrodedSTA 1670-1680 CORROSION. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT (CLIP) IAW SRM 53-00-51, 51-10-02, 51-40-05, 51-20-01, DEFECT SIZE: 5.40 INCH L X 2.40 INCH W X .069 INCH D.SDR USAA053Fitting · corrodedSTA 1200-1640, AFT CARGO RT FLOOR TIE DOWN FITTINGS CORRODED. REMOVED CORROSION, INSPECTED, REPLACED OUT OF LIMIT TIE DOWN FITTINGS IAW SRM 51-40-02, EA 97241, DEFECT SIZE: 2 INCH L X 1INCH W.SDR USAA054Fitting · corrodedSTA 1200-1640 AFT CARGO LT FLOOR TIE DOWN FITTINGS CORRODED. REMOVED CORROSION, INSPECTED PER SRM 51-10-02, EA 97241, DEFECT SIZE: 2 INCHES L X 1INCH W.SDR USAA052Floor Support · corrodedSTA 1660-1680, RBL APPROX 55 CORROSION. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT IAW SRM 53-00-51, 51-40-05, 51-21-01, DEFECT SIZE: 20 INCH L X 2 INCH W X .020 INCH D.SDR BB06001Fan · failedFLIGHT 723, CLT-BOS, AT THE BEGINNING OF THE DESCENT, FA'S NOTICED SMOKE ODOR FROM THE MID TO THE REAR OF THE AIRCRAFT, FOLLOWED BY AN EQUIPMENT COOLING OVERHEAT. CREW DECLARED AN EMERGENCY AND LANDED BOS WITH NO FURTHER INCIDENT. MAINTENANCE REPLACED THE LESDR BB05106Charger · faultyMCO - THE L2 DOOR EXTERIOR EMERGENCY SLIDE LIGHT WAS FOUND INOPERATIVE. MAINTENANCE REPLACED THE L2 DOOR EMERGENCY LIGHTS CHARGER ASSEMBLY. OPERATIONALLY CHECKS OK.SDR USAA051303Sill · corrodedFOUND CORROSION DOOR SILL SUPPORT AT R1. REPLACED CORRODED SILL SUPPORT (BY FAB) PER SRM 53-00-51, 51-40-02, 51-20-01, DEFECT SIZE: 36 BY 4 BY .015.SDR USAA051298Mount · corrodedFOUND GALLEY MOUNT CORRODED STA 327 RBL 45. REMOVED AND REPLACED WITH NEW MOUNT PER SRM 53-00-51, DEFECT SIZE: 1"W BY 2"L BY .025"D.SDR USAA051299Floor Support · corrodedFOUND FLOOR SUPPORT CORRODED (FITTING) STA 324-345 RBL 3. REMOVED AND REPLACED WITH NEW SUPPORT PER SRM 53-10-13 AND 51-40-02, DEFECT SIZE: 3"L BY 2"W BY .040"D.SDR USAA051300Floor Support · corrodedFOUND STA 324 AND 342 FLOOR SUPPORT CORRODED. FAB'D NEW FLOOR SUPPORT PER MAE TRAVELER T5/551168, SRM 51-010-00 AND SRM 53-00-51, DEFECT SIZE: 3"W BY 2"W BY .025"D.SDR USAA051302Floorbeam · corrodedFOUND FLOORBEAM CORRODED STA 324 RBL 58 UPPER CAP. FAB FLOORBEAM UPPER CAP AND SPLICE ANGLES PER SRM 53-00-51, 51-40-02, 51-20-01, 51-70-12, EA 96967, DEFECT SIZE: 4"L BY 3"W BY 0.025"D.SDR USAA051304Sill · corrodedFOUND DOOR SILL SUPPORT CORRODED AT R1 DOOR. REMOVED AND REPLACED CORRODED SUPPORT (BY FAB) PER SRM 53-00-51, 51-40-02, DEFECT SIZE: 2.5 BY 1.0 BY .020".SDR USAA051301Floor Support · corrodedFOUND FLOOR SUPPORT CORRODED, STA 312-324 RBL 43. FAB PART PER MAE TRAVELER T5/551155 AND SRM 51-40-02, 53-00-51, 51-40-05, 51-20-02, DEFECT SIZE: 1"L BY 1" W BY 0.032"D.SDR USAA051236Intercostal · corrodedFOUND INTERCOSTAL CORRODED CABIN FLOOR STA 1661-1681 RBL10; LEVEL 1;CORROSION LEVEL 1; TASK C53-252-03. FABRICATED NEW INTERCOSTAL AND INSTALLED PER SRM 51-30-01, DEFECT SIZE: 2" SQ.SDR USAA051235Support · corrodedFOUND SUPPORT CORRODED STA 1640 AND 1681 RBL 57; CORROSION LEVEL 1; TASK C53-252-03. REMOVED, FABRICATED AND INSTALLED SUPPORTS PER SRM 51-40-02, 53-00-51, DEFECT SIZE: 1 BY 2 BY .065 AND 2 BY 2.5 BY .070.SDR USAA051234Plate · corrodedFOUND PLATE SUPPORTS CORRODED STA 1640-1681 LBL 57 WL 208.10; CORROSION LEVEL 1; TASK C53-251-03. REMOVED, FABRICATED AND INSTALLED SUPPORTS PER SRM 51-40-02, 53-60-51 FIG 101 AND 51-20-02, DEFECT SIZE: 1" BY 1" AND 1.5" BY 2".SDR USAA051233Floor Support · corrodedFOUND FLOOR SUPPORT CORRODED STA 1640-1661 BL 0; CORROSION LEVEL 1; TSK C53-251-03. INSTALLED FABRICATED FLOOR SUPPORT PER SRM 51-10-02, 51-40-02, 51-40-05, DEFECT SIZE: 2" BY 3" AREA.SDR USAA051232Floorbeam · corrodedFOUND CORROSION STA 397 RBL 51, WL 208.10; CORROSION LEVEL 1; TASK C53-222-03. FABRICATED AND INSTALLED FLOOR SUPPORT PER SRM 53-00-51, 51-40-02, DWG 141N5170, DEFECT SIZE: 4" BY 3" BY .030".SDR USAA051231Mount · corrodedFOUND GALLEY MOUNT PAD CORRODED STA 1687 RBL 7; LEVEL 1; TASK C53-252-03. REMOVED AND REPLACED WITH NEW MOUNT PAD PER SRM 51-40-02 DEFECT SIZE: 1 SQ IN.SDR USAA051230Support Angle · corrodedFOUND SUPPORT ANGLES CORRODED STA 1650-1675 RBL 62 WL 208.10 (R-4 DOOR) THRESHOLD; CORROSION LEVEL 1; TASK C53. FABRICATED AND INSTALLED NEW SUPPORT ANGLES PER SRM 51-20-02, 51-40-02, BOEING DWG 146N8712 AND 146N8769 DEFECT SIZE: 0.5" BY 0.37" BY 0.013" ANDSDR USAA051228Mount · corrodedAFT GALLEY MOUNT AT BS 1687 LBL 7; CORROSION LEVEL 1; TASK C53-251-03. REMOVED AND REPLACED GALLEY MOUNT PAD PER SRM 51-40-02, DEFECT SIZE: 1 SQ IN.SDR USAA051227Floor Support · corrodedFOUND FLOOR SUPPORT STA 345 AND 365.25 BL 0; CORROSION LEVEL 1; TASK C53-322-03. INSTALLED NEW BEAM PER BOEING DWG 141N5191, SRM 51-30-05, 51-40-02 AND 51-30-05, DEFECT SIZE: 1.5" BY 1" BY 0.012" AREA.SDR USAA051237Floorbeam · corrodedSTA 1640 RBL 56 AND LBL 56 MAIN CABIN FLOORBEAM CORRODED. REPLACED NEW UPPER CHORD AND SPLICE PER TYP REP 53-15-01 AND SRM 51-40-02, DEFECT SIZE: 10" L BY 1.5" W BY .97"D.SDR USAA051223Floorbeam · corrodedFOUND FLOORBEAM WEB CORRODED STA 331 RBL 1, FLOORBEAM WEB; LEVEL 1;TASK C53-222-03. REMOVED AND REPLACED FLOORBEAM; LEVEL 1; TASK C53-222-03, DEFECT SIZE: 1.9"L BY 1.6"W BY .080"D.
Back to Boeing 757-2B7