Boeing 757-2Q8
Service difficulty reports · 2,798
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572Q8' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572Q8' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA12014926818Skin · gouged3 INCH LONG GOUGE IN SKIN AT STA 1661 AND STRINGER S-20L .015 TO .025" REPAIRED AND INSTALLED PERMANENT REPAIR IAW ERA 509451-14, REV.SDR DALA12014916818Skin · punctured3 X 4" PUNCTURE IN SKIN AT BS 1630 BETWEEN STRINGER S-20L AND S-19L REPAIRED AND INSTALLED PERMANENT REPAIR IAW ERA 509449-14 REV.SDR DALA1254906804Transceiver · inoperativeWEATHER RADAR INOPERATIVE ON TAXI OUT. TRANSCEIVER WILL SWEEP ANTENNA BUT WILL NOT PAINT WEATHER.SDR DALA1254456809Fuse · inoperativeTHE EMERGENCY EXIT SIGN ABOVE L1 DOOR INOPERATIVE. R & R F2 FUSE AT POWER SUPPLY M731. OPS CHECKED GOOD.SDR DALA1250386809Battery Pack · inoperativeEMERGENCY EXIT SIGN ABOVE L1 DOOR INOPERATIVE. FOUND BATTERY PACK M731 FAULTY. REPLACED BATTERY PACK IAW AMM 33-51 CHECKED GOOD. OK FOR SERVICE.SDR DALA1250196801Floorbeam · crackedFLOORBEAM AT BS 700 CRACKED AT LBL 24.75 AND LBL 45.5. REPAIR COMPLETED IAW ER/A 507520-14.SDR DALA1249776803Slide · low pressureL3 EMERGENCY EXIT DOOR SLIDE LOW PRESSURE PRESSURE INDICATOR BEFORE GREEN BAND. REMOVED AND INSTALLED L3 DOOR SLIDE IAW JIC OPN 78020.SDR DALA1249156806Skin · burnedFOUND LIGHTNING STRIKE DAMAGE ON LT PACK DOOR, REPAIRED DAMAGE IAW SRM 52-40-02.SDR FDEA201209193355Slide · dislodgedDOOR APPEARED TO BE ARMED AFTER DOOR WAS OPENED. WHEN F/O OPENED LT ENTRY DOOR THE SLIDE WAS CAUGHT ON GIRT BAR AREA AND SLIDE FELL OUT. SLIDE DID NOT INFLATE F/O THOUGHT DOOR WAS UNARMED. FOUND L1 DOOR ASSIST BOTTLE DISCHARGED & DOOR WAS ARMED. R & R LEFT SDR DALA12007576818Control Panel · odorAIR RETURN BACK TO DEPARTURE DUE TO BURNING ELECTRIC ODOR IN THE FLIGHT DECK AND CABIN. FOUND VOR/DME CONTROL PANEL WITH ELECTRICAL ODOR. R & R PANEL, CHECKED OK.SDR DALA1248726808Seat Track · damagedSEAT TRACK AT 33ABC DAMAGED. REPAIRED IAW ERA 506996-14.SDR DALA1248696809Power Supply · inoperativeDURING EMERGENCY LIGHTS TEST, FOUND LT DOOR EXIT OVERHEAD SIGN OUT AND GALLEY 1A EMERGENCY EXIT LIGHT OUT. FOUND EMERGENCY LIGHT POWER SUPPLY M0731 BAD. R & R POWER SUPPLY M0731 IAW AMM 33-5. CHECKED OK.SDR DALA1247956809Battery Pack · inoperativeDURING MAINTENANCE CHECK, FOUND L1 OVERHEAD EXIT LIGHT INOPERATIVE. MAINTENANCE REPLACED BATTERY PACK AND CHARGER M731 PER IAW 33-51. OPERATION OF LIGHT NOW CHECKED OK.SDR FDEA201208042855Cam · out of rigDURING B CHECK, L1 DOOR UPPER FWD CAM PLATE NEEDS TO BE RIGGED. ACCOMPLISHED RIGGING OF L1 DOOR UPPER FWD CAM PLATE IAW AMM. NO FAULTS NOTED.SDR FDEA201208042854Roller · out of adjustDURING B-CHECK, FOUND L1 DOOR UPPER FWD CRANK ARM ROLLER CONTACTS THE CAM PLATE WHEN CLOSING THE DOOR. ACCOMPLISHED RIGGING OF L1 DOOR UPPER FWD CRANK ROLLER CAM PLATE AND ROLLER IAW AMM NO FAULTS NOTED.SDR FDEA201207272716Proximity Switch · malfunctionedON APPROACH, RECEIVED A L/E SLAT ASYM ALERT. ACFT DID NOT HAVE CONTROL PROBLEMS. UNABLE TO EXTEND FLAPS BEYOND 0 DEGREE AND 1 DEGREE, HYDRAULICALLY. USED ALTERNATE FLAPS FOR LANDING. R & R LOSS SENSING SWITCH FOR INBOARD LE SLATS IAW AMM 27-81-41-4, THRUSDR FDEA201207262701Window · out of adjustCAPTAIN`S SLIDING WINDOW DOES NOT STAY CLOSED WITH LATCH LOCKED CLOSED. WINDOW WILL CRANK OPEN WITH WINDOW LOCKED CLOSED. PERFORMED ADJUSTMENT TEST IAW MM 56-11-02-5. CAPTAINS SLIDING WINDOW, OPS CHECK NORMAL. RII ACCOMPLISHED.SDR FDEA201207262700Window · out of adjustF/O SLIDING WINDOW DOES NOT STAY CLOSED WITH LOCK IN LOCKED CLOSED. WINDOW WILL CRANK OPEN WITH WINDOW IN LOCKED CLOSED. PERFORMED ADJUSTMENT TEST OF F/O'S SLIDING WINDOW IAW MM 56-11-02-5. FINAL CLOSED.SDR DALA1239526818Skin · corrodedSKIN CORRODED AROUND UPPER AND LOWER SURFACE OF CTR LOWER LAVATORY PANEL. COMPLIED WITH ERA 503383-14 REV A,SDR DALA1236736818Floorbeam · damagedFLOORBEAM UPPER CAP, DAMAGED AT BS 418 - LBL 55. REMOVED DAMAGED SECTION OF FLOORBEAM. BEGAN MAKING REPAIR PARTS REF SRM 53-00-511. REPAIRED PER PRI 503241-14 REV O.SDR DALA1237416818Frame · dentedDURING HMV, ONE DENT WAS FOUND ON THE UPPER FLANGE OF THE BS 1260 LOWER FRAME BETWEEN STR 23L AND STR 24L. REPAIRED THE DAMAGE TO THE FRAME PER SRM 53-00-07 REPAIR 5, FIGURE 201, DETAIL III.SDR DALA12003606818Frame · dentedDURING HMV, ONE DENT WAS FOUND ON THE LT SIDE C2 CARGO BAY BS 1300- FRAME FLANGE. REMOVED DAMAGED AREA PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF CUTOUT, NO ITEMS NOTED. FABRICATED REPAIR AND INSTALLED. TREATED, PRIMED AND PAINTED REF ERA50279SDR DALA1233736818Support · corrodedFORE AND AFT SUPPORTS UPPER AND LOWER SIDES FOUND CORRODED, OF LOWER LAVATORY PANEL. REMOVED SUPPORTS AND FOUND TO BE CORRODED BEYOND LIMITS. INSTALLED SUPPORT.SDR DALA1233726818Support · corrodedCORROSION FOUND AT FORE & AFT SUPPORTS FOR LOWER CENTER LAVATORY PANEL. AFT SUPPORT REMOVED ON NR 262 LOCATED ALL FASTENER HOLES AND SIZED DWG 149N7701. INSTALLED AFT SUPPORT BRACKETS FOR BOTH LEFT AND RIGHT PANEL SUPPORT BRACKETS DRILLED HOLES FOR NUTPLATESDR DALA13022596818Frame · damagedFRAME DAMAGED BS 1300, S25L. REPAIRED IAW ERA 06-502791-14AD.SDR FDEA201205161817Lamp · inoperativeL1 SLIDE LIGHT INOPERATIVE. RELAMPED IAW AMM 33-51-06-2-1. OPS CHECKED GOOD.SDR DALA1232216818Frame · dentedFOUND DENT, ON FRAME BS 1460. REMOVED DAMAGE AREA PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. COMPLIED WITH HFEC INSPECTION OF EXITING HOLES PER SRM 53-00-07 FIG 201. NO CRACKS FOUND, COLD WORKED END FASTENER HSDR DALA1232196818Frame · dentedFOUND DENT ON CARGO BAY FRAME BS 1480. REMOVED DAMAGE AREA PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. COMPLIED WITH BHEC IN EXITING HOLES COMMON TO REPAIR IAW NDT MANUAL PT 6 51-00-16. FABRICATED REPAIR PER SDR DALA1231836818Floorbeam · corrodedDURING INSPECTION CORROSION WAS DISCOVERED TO THE UPPER CAP OF THE FLOORBEAM LOCATED AT STATION 1640 AROUND FASTENER HOLES AND AT DOOR THRESHOLD. REMOVED DAMAGE AREA AND INSPECTED. NO DISCREPANCIES NOTED. FABRICATED REPAIR AND TREATED AREA.SDR DALA1232266818Frame · dentedFOUND DENT ON FRAME BS 720. REMOVED DAMAGE PER SRM 53-00-07 REPAIR 5. FORMED REPAIR ANGLE PER SRM 53-00-07 REPAIR 5. HFEC INSPECTION OF DAMAGE CUT OUT OK IAW SRM 53-00-07. COMPLIED WITH HFEC OF HOLES COMMON TO THE REPAIR PER SRM 53-00-07 REPAIR 5. NO INDISDR DALA1232246818Frame · dentedFOUND DENT ON FRAME BS 1580. REMOVED DAMAGED AREA PER SRM 53-00-07 REPAIR 5. PERFOMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. FABRICATED REPAIR PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF ALL INITIAL FASTENER HOLES PER SRM 53-00-0SDR DALA1232236818Frame · dentedFOUND DENT ON FRAME BS 1500. REMOVED DAMAGED AREA PER SRM 53-00-07 REPAIR 5. PERFOMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. COMPLIED WITH BHEC IN HOLES EXISTING COMMON TO REPAIR IAW NDT MANUAL PT 6 51-00-16, INSTALLED REPAIR PER SRM 53-00-07 SDR DALA1232226818Frame · dentedFOUND DENT ON FRAME BS 1340. REMOVED DAMAGED AREA PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. DRILLED DOUBLER PER SRM 53-00-07 REPAIR 5. INSTALLED REPAIR PER SRM 53-00-07.SDR DALA1232176818Frame · damagedFUSELAGE FRAME HAS TWO MISDRILLED HOLES BELOW STRINGER 2R. NOT WITHIN LIMITS PER SRM 53-00-07 FIG 1 SHEET 1. ROUTED OUT DAMAGE ON FRAME PER SRM 53-00-07 REPAIR 1. HFEC INSPECTED CUTOUT PER SRM 53-00-07 FIG 201. NO CRACKS FOUND MADE INSURANCE CUT TO ROUTEDSDR DALA1232166818Frame · damagedFUSELAGE FRAME HAS TWO HOLES MISDRILLED, BS 1000, RBL 10. ROUTED OUT DAMAGE ON FRAME PER SRM 53-00-07 REPAIR 1. PERFORMED HFEC OF CUTOUT AND HFEC INSPECTION PER SRM 53-00-07 REPAIR 1 FIG 204. NO CRACKS FOUND MADE INSURANCE CUT PER SRM 53-00-07 REPAIR 1. FSDR DALA1232156818Frame · dentedFRAME DENTED, C2 CARGO BAY LT SIDE BS 1400 - INNER "FREE FLANGE". REMOVED DAMAGED AREA PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. COMPLIED WITH OPEN HOLE EC INSPECTION IAW NDT MANUAL PT 6 51-00-16. FABRICASDR DALA1232146818Intercostal · corrodedCORROSION LOCATED AT BS 1600-1620 ON INTERCOSTAL. REMOVED INTERCOSTAL, DRILLED NEW INTERCOSTAL PER DWG 146N5451. INSTALLED INTERCOSTAL PER DWG 146N5451.SDR DALA1231856818Fastener · damagedDURING REWORK MAINTENANCE DISCOVERED DAMAGE TO TWO FASTENERS RT WING APPROXIMATELY RIB WS 285.65. LOCATED UNDERNEATH THE FWD END OF THE INBOARD SIDE LOAD FITTING. REMOVED FASTENERS AND PERFORMED INSPECTION. NO DISCREPANCIES NOTED. INSTALLED TWO FASTENERS RSDR DALA12000066818Frame · damagedDENT C2, CARGO COMPARTMENT, LT SIDE STA 1320 - INNER FREE FLANGE. REMOVED DAMAGE AREA PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. NO ITEMS REMOVED OLD DOUBLER AND FASTENERS PERFORMED BHEC INSPECTION PER SRM 53-0SDR DALA1230816818Frame · dentedDURING INSPECTION A DENT WAS DISCOVERED IN THE C2 CARGO COMPARTMENT LEFT SIDE BS 1520 - INNER FREE FLANGE. REMOVED DAMAGE AREA AND INSPECTED REF: B757 SRM 53-00-07 REPAIR 5. NO DISCREPANCIES NOTED. FABRICATED REPAIR, INSTALLED AND TREATED AREA.SDR DALA1230806818Frame · damagedDURING INSPECTION A DENT WAS DISCOVERED IN THE C2 CARGO COMPARTMENT LEFT SIDE BS 1420 - INNER FREE FLANGE. REMOVED DAMAGE AREA AND INSPECTED IAW SRM 53-00-07 REPAIR 5. NO DISCREPANCIES NOTED. FABRICATED REPAIR, INSTALLED AND TREATED AREA.SDR DALA1230116818Stringer · damagedMAINTENANCE DISCOVERED TOOLING DAMAGE AT BS 1340 STRINGER 2L. ROUTED OUT DAMAGE, MADE INSURANCE CUT AND INSPECTED, NO CRACKS FOUND. FABRICATED REPAIR AND INSTALLED, TREATED/PAINTED AREA.SDR DALA1230096818Stringer · damagedWHILE PERFORMING MAINTENANCE, DISCOVERED A MISDRILLED HOLE AT LOCATION STATION 1440 STRINGER 2-R. ROUTED OUT DAMAGE ON FRAME AND MADE INSURANCE CUT TO AREA. INSPECTED, NO CRACKS FOUND. FABRICATED REPAIR AND TREATED & PAINTED.SDR FDEA201205041734Lamp · inoperativeL1 SLIDE LIGHT INOPERATIVE. RELAMPED IAW AMM 33-51-06-2-1. OPS CHECKED GOOD.SDR DALA1228156818Skin · misrepairedSKIN AT BS 400, STR 5L TO 7L MISREPAIRED. REPAIRED IAW ERA 502651-14 REV ORIG.SDR DALA1228086818Floorbeam · corrodedFLOORBEAM CORRODED UNDER NUTPLATES, BS 1390-1420, LBL 3 . REMOVED CORROSION AND AREA OUT OF LIMITS PER SRM 53-00-53. REMOVED AND INSTALLED FLOORBEAM.SDR DALA1228066818Intercostal · corrodedINTERCOSTAL WEB CORRODED AT BS 1520-1540. REMOVED WEB, DRILLED AND INSTALLED NEW WEB AT AND BETWEEN LOCATION STA 1520-1540 REF DWG 146N5451.SDR DALA1228056818Frame · corrodedFRAME AT BS 1560 ABOVE S26L IS CORRODED AT FASTENER HOLE. REMOVED FORMER REPLACED FRAME PER DWG 453N1801.SDR DALA1228046818Frame · corrodedCORROSION ON FRAME AT STA 1560 ABOVE STR 26R IS CORRODED AT FASTENER HOLE. REMOVED FRAME REPLACED FORMER PER DRAWING 453N1801.SDR DALA1228026818Floorbeam · corrodedFLOORBEAM CORRODED, STA 324.0 UNDER GALLEY BEAM, BL0-TO CUSP LINE, CONDITION: CORROSION LOCATION FWD WET AREA POS: CN REPAIRED PER ERA 501777-14 PRI REV 3. REPAIRED PER ERA501777-14 PRI REV4 PRI 501777-14 REV 4 MATCHES ERA 501777-14 REV ORIG.
Back to Boeing 757-2Q8