Boeing 757-2Q8
Service difficulty reports · 2,798
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572Q8' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572Q8' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1228036818Floorbeam · crackedSTABILIZATION STRAP CRACKED BS 1640, FLOORBEAM STABILIZATION STRAP, LOWER SURFACE OF BEAM, COMPLETED STEPS 1 AND 2 PER ERA384483-14MA REV C. INSPECTION OF STOP DRILL FOR CRACK CONTAINMENT OK, REF ERA 384483-14MA REV C STEP 3. FABRICATED AND DRILLED DOUBLERSDR DALA1226646818Angle · corrodedDURING INSPECTION, FOUND THE CUSP WEB ANGLE CORRODED AT BS 1672. MAINTENANCE REMOVED AND REPLACED THE CUSP WEB ANGLE IAW SRM 53-00-51, AND DWG 146N8722.SDR DALA1226626818Cusp Web · damagedDURING INSPECTION, FOUND WEB DAMAGED AT CUSP ANGLE, LOWER SIDE BS 1635, LBL 65. MAINTENANCE REMOVED THE CUSP WEB, POSITIONED, LOCATED, AND SIZED ALL HOLES IAW DWG 146N8722, INSTALLED OTBD ROW OF FASTENERS AND REPLACED THE CUSP WEB IAW DWG 146N8722.SDR DALA1226416808Light · inoperativeRIGHT AFT EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY CHARGER FUSE, LIGHT OPERATION NORMAL.SDR DALA2014120106361Skin · dentedDENT FOUND IN FUSELAGE BS 686 BETWEEN STRINGERS 23 - 24R. INSPECTED AND REPAIRED IAW SRM 53-00-01.SDR DALA1226426818Intercostal · damagedINTERCOSTAL- DAMAGED LOCATION: STA 345 - 365 LBL 20. FABRICATED REPLACEMENT PART PER BAC DWG 141N5150. INSTALL INTERCOSTAL (QC 2058) REPLACED WEB REF BAC DWG 141N5150.SDR DALA1226716818Seat Track · corrodedSEAT TRACK - CORROSION LOCATION: STA 1640 RT OUTBD TRACK POS: AFT CLEANED TRACK AND FOUND TO BE OUT OF LIMITS PER B757 SRM 53-00-52 AND REMOVED TRACK SECTION FROM STA 1540 -1640 SEAT TRACK FABRICATED ON SHOP ORDER EY7737 BEGAN DRILLING SEAT TRACK. OK TO INSTSDR DALA1226696818Angle · corrodedZ- ANGLE- CORROSION LOCATION: FLOOR SUPPORT RT OUTBD FLOOR SUPPORT STA 1300-1340. POS: AFT REMOVED Z ANGLE AT STA 1300-1340 RT OUTBD FLOOR SUPPORT FASTENER HOLES IN Z ANGLE AT STA 1300-1340. OK TO TREAT & PAINT PER PS 900-3-6 NR 3 BEGAN INSTALLATION OF Z ANGSDR DALA1226676818Bracket · corrodedBRACKET - CORROSION LOCATION: STA 1300 STR 28R POS: AFT REMOVED BRACKET DRILLED UP NEW BRACKET INSTALL OF REPAIR BRACKET COMPLETED INSTALLATION OF BRACKET PER DWG 146N5400.SDR DALA1226656818Floor Support · corrodedCHANNEL- CORROSION LOCATION: FLOOR SUPPORT CHANNEL LOCATED FROM STA 1500-1640 RBL 7.25 POS: AFT REMOVED FLOOR SUPPORT INSTALLED FLOOR SUPPORT CHANNEL PER BAC DWG 146N5390.SDR DALA1226636818Floor Support · corrodedCHANNEL- CORROSION LOCATION: FLOOR SUPPORT CHANNEL LOCATED FROM STA 1500-1640 RBL 12.25 POS: AFT REMOVED FLOOR SUPPORT CHANNEL BEGAN DRILLING HOLES ON FLOOR SUPPORT CHANNEL. OK TO INSTALL FLOOR SUPPORT FINISH INSTALLATION OF FLOOR SUPPORT CHANNEL PER BAC DWG SDR DALA1226616818Seat Track · damagedDURING INSPECTION, FOUND OTBD LEFT SEAT TRACK AT BS 1636, INNER LIP DAMAGED BEYOND ALLOWABLE LIMITS. MAINTENANCE REMOVED THE SEAT TRACK, FABRICATED, AND REPLACED THE SEAT TRACK IAW DWG 146N512.SDR DALA1226596818Seat Track · damagedDURING INSPECTION FOUND LEFT OUTBD SEAT TRACK AT BS 1601.5, STUD HOLE DAMAGED BEYOND ALLOWABLE LIMITS. MAINTENANCE REMOVED SEAT TRACK, FABRICATED, AND REPLACED SEAT TRACK IAW DWG 146N5120.SDR DALA1226586818Floorbeam · corrodedCARGO FLOOR PANEL BEAM CORRODED AT NUT PLATES. CORROSION LOCATION: AFT CARGO STA 1340-1440 RBL 10 POS: AFT TASK REMOVED CARGO FLOOR PANEL BEGAN AT FACTORY SPLICE STA 1340-1440 DRILLED UP REPLACEMENT SECTION OF BEAM PER BAC DWG146N5390 ALODINED REPLACEMENT BEASDR DALA1226566818Seat Track · damagedDURING INSPECTION FOUND LEFT OTBD SEAT TRACK BS 1614, DAMAGED ON INNER LIP BEYOND ALLOWABLE LIMITS. MAINTENANCE REMOVED AND REPLACED SEAT TRACK IAW DWG 146N5120.SDR DALA1226486818Floor Support · corrodedFLOOR SUPPORT- CORROSION. LOCATION: STA 1640-1661, LBL 52 AT TOP AND BOTTOM OF FASTENER HOLES. REMOVED SUPPORT DRILLED NEW SUPPORT REF B757 DWG 146N5230. OK TO INSTALL. INSTALLED FLOOR SUPPORT REF B757 DWG 146N5230.SDR DALA1226476818Floor Panel · corrodedFIXED FLOOR PNL- CORROSION. LOCATION: RT SIDE FS 1200 -1310 C-2 BB. POS: AFT REMOVED FIXED FLOOR PER B757 SRM 53-00-53 (292233) DRILLED UP NEW FIXED FLOOR PANEL PER BAC DWG 146N5390 OK TO INSTALL. INSTALLED FIXED FLOOR PANEL PER BAC DWG 146N5390.SDR DALA1226466818Intercostal · corrodedCORROSION, AFT CARGO BIN, BILGE, STA 1618 BL-0. AFT CARGO POS: AFT REMOVED INTERCOSTAL FOUND CORROSION ON ADJACENT SKIN & FRAME. REMOVED FRAME CLIP & SEVERAL FASTENERS TO ACCESS CORROSION. REMOVED CORROSION ON SKIN & FRAME CLIP PER B757 SRM 53-00-01 & 53-00SDR DALA1226446818Floor Support · corrodedFLOOR SUPPORT - CORROSION LOCATION: FS 1320 & 1330 BOTTOM SIDE, ABOVE STR 29R,C-2 BB POS: AFT FLOOR SUPPORT OUT OF LIMITS PER B757 SRM 53-00-53 BEGAN REMOVAL OF SUPPORT FINISHED REMOVING FLOOR SUPPORT AND DRILLED UP REPLACEMENT PER B757 BAC DWG 146N5390 (8828SDR DALA1226436818Floor Panel · corrodedLT FIXED FLOOR PNL- CORROSION LOCATION: FS 1310-1410 C-2 BB POS: AFT BLENDED CORROSION AND FOUND AREA TO BE OUT OF LIMITS PER B757 SRM 53-00-53. REMOVED FIXED FLOOR PANEL BEGAN DRILLING NEW FIXED FLOOR PANEL REF BAC DWG 146N5391 OK TO INSTALL [1315]. FINISHSDR DALA1226406818Floorbeam · corrodedFLOORBEAM - CORROSION LOCATION: BL 0 STA 1640. REMOVE CORROSION & FOUND OUT OF LIMITS PER B757 SRM 53-00-51. T-CAP REPLACED ON N/R 459.SDR DALA1226396818Floor Support · corrodedFLOOR SUPPORT- CORROSION LOCATION: STA 1650 -1660, RBL 52 CORROSION AT FASTENER HOLE ON TOP AND BOTTOM. REMOVED FLOOR SUPPORT BEGAN DRILLING UP NEW FLOOR SUPPORT PER BAC DWG 146N5230. COMPLETED DRILLING FLOOR SUPPORT PER BAC DWG 146N5230. INSTALLED SUPPORT SDR DALA1226386818Intercostal · corrodedINTERCOSTAL- CORROSION LOCATION: BL 0 STA 1640-1660. REPLACED INTERCOSTAL REF BAC DWG 146N5230.SDR DALA1226266818Floor Support · corrodedCHANNEL- CORROSION LOCATION: FLOOR SUPPORT CHANNEL LOCATED FROM STA 1500-1640 LBL 2.5. POS: AFT REMOVED CHANNEL 29MAR12 DRILLED UP CHANNEL PER BAC DWG 1465390 OK TO INSTALL [1315] INSTALLED NEW CHANNEL PER BAC DWG 146N5390.SDR DALA1226256818Floor Support · corrodedCHANNEL- CORROSION LOCATION: FLOOR SUPPORT CHANNEL LOCATED FROM STA 1500-1640 LBL 12.25 POS: AFT REMOVED FLOOR SUPPORT CHANNEL FROM STA 1500 TO 1640 LBL 12.25. OK TO INSTALL. STARTED INSTALLATION OF CHANNEL FROM STA 1500 TO 1600 (458447) INSTALLED CHANNEL SDR DALA1226246818Floor Support · corrodedCHANNEL CONDITION: FLOOR SUPPORT CHANNEL LOCATED FROM STA 1500-1640 RBL 2.5. POS: AFT REMOVED CHANNEL. DRILLED UP NEW CHANNEL PER BAC DWG 146N5390. OK TO INSTALL. INSTALLED CHANNEL PER BAC DWG 146N5390.SDR DALA1226236818Floor Panel · corrodedFIXED FLOOR PNL - CONDITION: CORROSION LOCATION: LT SIDE FS 1200-1310 C-2 BB BLENDED CORROSION STA 1200 - 1260 (348183) BLENDED AREA AND FOUND TO BE OUT OF LIMITS PER B757 SRM 53-00-53 (486125) BEGAN REMOVING FIXED FLOOR PANEL (486125). REMOVED FIXED FLOORSDR FOTR2107117579Frame · dentedAFT LOWER CARGO COMPARTMENT HAS DENTED FRAME AT LT BS 1500, BETWEEN STRINGERS 25L AND 27L. CUT OUT DAMAGED AREAS, FABRICATED REPAIR "J" DOUBLER, AND INSTALLED REPAIR DOUBLER IAW SRM 53-00-07, FIG 201, REPAIR 5.SDR DALA1226196818Floor Support · corrodedFLOOR SUPPORT- CONDITION: CORROSION LOCATION: INSIDE R4 DOOR, STA 1675-1679, RBL 50. REMOVED CORROSION CHECKED LIMITS PER B757 SRM 53-00-04 FIG 101 FOUND TO BE OUT OF LIMITS. DRILLED UP NEW SUPPORT ANGLE REF DWG BAC DWG 146N5230. REPLACED SUPPORT REF DWG BASDR DALA1226186818Support · corrodedCORROSION LOCATION: STA 1661- 1681, RBL 52 CORROSION AT TOP AND BOTTOM OF FASTENER HOLES REMOVED CORROSION CHECK LIMITS PER B757 SRM 53-00-04 FIG 101 AND FOUND TO BE OUT OF LIMITS. DRILLED UP NEW SUPPORT REF DWG 146N5230. REPLACED SUPPORT REF REMOVED CORROSSDR DALA1225876806Engine · bird ingestionAFTER TAKEOFF AT APPROXIMATELY 800AGL AIRCRAFT INGESTED BIRDS INTO NR 2 ENGINE, WHICH RESULTED IN MULTIPLE ENGINE STALLS. ENGINE WAS SHUTDOWN AND AIRCRAFT RETURNED AIRPORT WITH NO FURTHER INCIDENTS REPORTED. REMOVED AND REPLACED ENGINE AND REPAIRED OR REPLASDR DALA1224286818Floor Support · corrodedFLOOR SUPPORT - CORROSION LOCATION: FS 1330 RT OF STR 30, BOTTOM SIDE,C-2 BB POS: C/W ON N/R CARD 163 (645474).SDR DALA1224266818Floorbeam · corrodedCARGO PANEL FLOORBEAM CORRODED UNDER NUT PLATES. AFT CARGO STA 1390-1405, RBL 10 -- MKD. REMOVE CARGO FLOOR PANEL BEAM AT FACTORY SPLICE STA 1340-1440. DRILLED UP REPLACEMENT SECTION OF BEAM PER BAC DWG 146N5390 (882888). ALODINED REPLACEMENT BEAM PER BAC SDR DALA1224246818Floor Support · corrodedFLOOR SUPPORT - CORROSION LOCATION: FS 1304 & 1320 RBL 2 BOTTOM SIDE, C-2 BB POS: AFT FLOOR SUPPORT OUT OF LIMITS PER B757 SRM 53-00-53 (453003) BEGAN REMOVAL OF SUPPORT (792172) COMPLETED REMOVAL OF FLOOR SUPPORT (497049) FABRICATED NEW ANGLE (645474) OK TO ISDR DALA1224226818Floor Support · corrodedFLOOR SUPPORT PANEL- CORROSION STA 720-740 AT NUT PLATE NEAR L2 DOOR AFT DRAIN POS: MID REMOVED FLOOR SUPPORT (303974) DRILLED NEW FLOOR SUPPORT REF BAC DWG 143N5400 (955289) OK TO INSTALL NEW FLOOR SUPPORT REF BAC DWG 143N5400.SDR DALA1224206818Floor Support · corrodedFLOOR SUPPORT- CONDITION: CORROSION LOCATION: STA 680-700 AT NUT PLATE LOC NEAR FWD DOOR DRAIN FOR L-2 DOOR (MARKED). REMOVED FLOOR SUPPORT (303974) DRILLED NEW FLOOR SUPPORT REF BAC DWG 143N5400 (953289) INSTALLED NEW FLOOR SUPPORT (953289) REF BAC DWG 1435SDR DALA1224186818Crease Beam · corrodedCHORD - CONDITION: CORROSION LOCATION: INNER UPPER CREASE BEAM CHORD BETWEEN STA 729 - STA 740 APPROX LBL 64 POS: MID REMOVED DAMAGED CHORD AND DRILLED UP NEW PART PER BAC DWG 143N8322 (955289) INSTALLED NEW CHORD ANGLE REF BAC DWG 143N8322.SDR DALA1224156818Floor Support · corrodedFLOOR SUPPORT- CORROSION STA 700-720 OUTBD SUPPORT AT NUT PLATE. REMOVE FLOOR SUPPORT (303914) DRILLED NEW FLOOR SUPPORT REF BAC DWG 143N5400. INSTALLED NEW FLOOR SUPPORT REFBAC DWG 143N5400.SDR DALA1224146818Support · corrodedFLOOR PANEL SUPPORT- CORROSION LOCATION: STA 720-740 AT NUT PLATE NEAR R-2 AFT DOOR DRAIN POS: MID REMOVED SUPPORT PER BAC DWG 143N5400 (320257) DRILLED NEW GUTTER SUPPORT REF BAC DWG 143N5400 (953289) OK TO INSTALL. INSTALLED NEW SUPPORT REF BAC DWG 143N540SDR DALA1224136818Intercostal · corrodedINTERCOSTAL CORRODED STA 1280-1300 LBL 25, MARKED NUMBER 2- CORROSION LOCATION: MID LAV WET AREAS POS: AFT BEGAN REMOVAL OF INTERCOSTAL AT STA 1280 - 1300 REF BAC DWG 146N5270 (416338) REMOVED INTERCOSTAL STA 1280-1300 LBL 25 REF BAC DWG 146N5270 DRILLED NESDR DALA1224126818Intercostal · corrodedINTERCOSTAL CORRODED, STA 1260-1280 LBL 25 MARKED NUMBER 3- CORROSION LOCATION: MID LAV WET AREAS POS: CN BEGAN REMOVAL OF INTERCOSTAL AT STA 1260-1280 REF BAC DWG 146N5270 (416378 28MAR12) REMOVED INTERCOSTAL. BEGAN INSTALLATION OF INTERCOSTAL REF BAC DWG SDR DALA1224106818Floor Support · corrodedCARGO FLOOR PANEL BEAM CORRODED UNDER NUT PLATES- CONDITION: CORROSION LOCATION: AFT CARGO STA 1438, LBL 3 -- MKD POS: AFT REMOVED CORROSION AND AREAS OUT OF LIMITS PER B757 SRM 53-00-53. REMOVED FLOOR SUPPORT. OK TO INSTALL WORK, COMPLETED.SDR DALA1224086818Floor Support · corrodedCHANNEL CORROSION LOCATION: FLOOR SUPPORT CHANNEL LOCATED FROM STA 1500-1640 LBL 7.25 POS: AFT REMOVED FLOOR SUPPORT CHANNEL PER BAC DWG 146N5390 (492172) DRILLED UP REPLACEMENT FLOOR SUPPORT CHANNEL PER BAC DWG 146N5390. INSTALLED FLOOR SUPPORT CHANNEL PERSDR DALA1224056818Floor Support · corrodedFLOOR SUPPORT CORROSION LOCATION: STA 1661-1681, LBL 52 TOP AND BOTTOM OF FASTENER HOLES MARKED POS: CN REMOVED FLOOR SUPPORT (699498 27MAR12) DRILLED UP NEW SUPPORT AND INSTALLED STANDOFF CLIP PER B757 DWG 146N5230. INSTALLED NEW FLOOR SUPPORT PER B757 DWG SDR DALA1220966818Floorbeam · corrodedFLOORBEAM CORRODED, BS 324 UNDER GALLEY BEAM, BL 0 TO CUSP LINE. CORROSION FWD WET AREA. THE UPPER FLOORBEAM TEE WAS REMOVED AND A NEW SECTION WAS SPLICED IN PER ERA 501777-14.SDR FDEA201204021220Guard · out of adjustTHE EMERGENCY LIGHTS GUARD CANNOT BE CLOSED WITH THE SWITCH IN ARM, WITHOUT THROWING THE SWITCH TO OFF. RESET SAFETY GUARD ON EMERGENCY LIGHT SWITCH. SYS OPS CHECKED GOOD IAW AMM 33-51-00-5-0.SDR DALA1220476818Channel · corrodedHAT CHANNEL HAS CORROSION. REMOVED CORROSION AND CHECKED LIMITS PER SRM 53-00-51, FOUND TO BE OUT OF LIMITS. REMOVED SUPPORT. LOCATED HAT CHANNEL AND DRILLED REF DWG 146N5300. INSTALLED CHANNEL PER DWG 146N5300.SDR DALA1220456818Intercostal · corrodedRT MID LAV INTERCOSTAL CORRODED BS 1280-1300 RBL 25. REMOVED CHANNEL BS 1280-1300. BEGAN INSTALLATION OF RT MID LAV INTERCOSTAL PER DWG 146N5270. COMPLETED INSTALLATION ON NEW INTERCOSTAL REF DWG 146N5270.SDR DALA1220446818Intercostal · corrodedRT MID LAV INTERCOSTAL CORRODED, BS 1300-1320 RBL 25. REMOVED INTERCOSTAL BS 1300-1320 REF DWG 146N5270. DRILLED NEW INTERCOSTAL. INSTALLED NEW INTERCOSTAL AT BS 1300-1320 RBL 25 REF DWG 146N5270.SDR DALA1220436818Intercostal · corrodedINTERCOSTAL CORRODED STA 1240-1280 LBL 25. REMOVED INTERCOSTAL BS 1240-1260. TRANSFERRED HOLES TO NEW INTERCOSTAL PER DWG 146N5270. REPLACED CHANNEL PER REF 757 DWG 146N.
Back to Boeing 757-2Q8