SDR AALA951534Splice · corrodedAFW - STRINGER 39L SPLICE AT STATION 1307 CORRODED. FABRICATE NEW LONGER STRINGER SPLICE. INSTALLED SPLICE WET WITH SAME FASTENER TYPE AND PATTERN PER ENGINEERING MRB 767-1007. (M)SDR AALA951386Stringer · corrodedAFW - REMOVED 6 INCHES OF STR 39L DUE TO CORROSION. REQUESTED AUTHORIZATION FROM ENGINEERING TO EXTEND STRINGER SPLICE 6 INCHES AFT OF STA 1313. FABRICATED AND INSTALLED SPLICE. APPROVED BY ENGINEERING PER MRB 767-982. T.S.T. 40,223.25. CYCLES, 12,808. (SDR AALA951384Stringer · corrodedAFW - STRINGER CORRODED BEYOND SRM LIMITS. REQUESTED AUTHORIZATION FROM ENGINEERING TO REMOVE 5 INCHES OF STR 36L (1304.5 TO 1299.5) AND EXTEND STR SPLICE AT STA 1307 FORWARD TO STA 1294.5. T.S.T. 40,223.25. CYCLES, 12,808. (X)SDR AALA951380Stringer · corrodedAFW - STRINGER CORRODED BEYOND SRM LIMITS AT STA 1316. REQUESTED AUTHORIZATION FROM ENGINEERING TO REMOVE 5 INCHES OFF 39R (STA 1312 TO STA 1317) AND EXTEND STR SPLICE AT STA 1307 AFT TO STA 1323.5. T.S.T. 40,223.25. CYCLES, 12,808. (X)SDR AALA951388Strap · corrodedAFW - FAIL SAFE STRAP CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ROTOPEENED, TREATED, PRIMED, AND PAINTED. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-980. T.S.T. 40,223.23. CYCLES, 12,808. (X)SDR AALA951387Chord · corrodedAFW - UPPER SURFACE OF FAIL-SAFE CHORD. AFTER REMOVING CORROSION, FOUND BEYOND SRM LIMITS. BLENDED AND ROTOPEENED AREA. APPROVED FOR CONTINUED SERVICE IN NOTED CONDITION BY ENGINEERING PER MRB 767-986. T.S.T. 40,223.25. CYCLES, 12,808. (X)SDR AALA951336Cart · defectiveLHR - FLT NR 0116 - AFTER TAKEOFF AN ACRID ODOR WAS REPORTED IN THE MID GALLEY AREA ACCOMPANIED BY A TRACE OF SMOKE. SECURED GALLEY POWER AND ODOR DISSIPATED ALONG WITH SMOKE. LANDED LHR WITHOUT INCIDENT. REPLACED WARMING CART, NO ODOR OR SMOKE. SYSTEM GROSDR AALA951327Eel Connector · defectiveSFO - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT 35H AND INOPERATIVE. REPLACED PINS ON SEAT CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA951266Corner · corrodedAFW - FOUND CORROSION AROUND A NUT PLATE HOLE IN THE INNER FLANGE OF THE LOWER FORWARD CORNER PIECE OF THE BULK CARGO DOOR. FOUND BEYOND SRM LIMITS AFTER BLENDING. TREATED, PRIMED AND PAINTED AREA. REINSTALLED NUT PLATE, APPROVED FOR CONTINUED SERVICE BY ENSDR AALA951264Floor Beam · corrodedAFW - FOUND FLOOR BEAM CORROSION, REMOVAL BEYOND SRM LIMITS. ALODINE BLENDED AREA. FILL BLEND OUT WITH BMS-592. FABRICATE A REPAIR STRAP FROM .050 301 HALF HARD STAINLESS AND INSTALL WET PER ENGINEERING MRB 767-970.SDR AALA951262Skin · wornAFW - FOUND A GROOVE WORN IN THE LEFT PYLON INBOARD AND OUTBOARD SIDE SKINS. BOTH GROOVES WERE CAUSED BY AN ANGLE ON THE THRUST REVERSER RUBBING ON THE SIDE SKINS. BLENDED AND REFINISHED GROOVES. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINESDR AALA951261Frame · crackedAFW - FOUND WEB OF FRAME AT STATION 1219 BL 0 CRACKED. REMOVED DAMAGE, FABRICATED REPAIR DOUBLER FROM 0.032 7075-T6 ALUMINUM AND INSTALLED WET WITH BMS5-95 SEALANT, ALODINED, PRIMED AND PAINTED PER ENGINEERING MRB 767-972. (M)SDR AALA951211Te Skin · delaminatedSFO - DURING OVERNIGHT CHECK, NR 5 LEADING EDGE SLAT FOUND WITH DELAMINATION AT MOST INBOARD AREA AT TRAILING EDGE WHICH WAS BEYOND SRM LIMITS. REPLACED NR 5 LEADING EDGE SLAT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA951188Eel Connector · defectiveSFO - DURING OVERNIGHT CHECK, EMERGENCY SEAT LIGHTS ON LEFT SIDE OF ROW 31 FOUND INOPERATIVE. REPLACED CONNECTOR AT SEAT ROW 33. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA951185Eel Wire · brokenSFO - DURING OVERNIGHT CHECK, FOUND LOWER CEILING RIGHT EMERGENCY EXIT LIGHT SIGN INOPERATIVE. REPAIRED BROKEN WIRE ON EMERGENCY EXIT SIGN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA950042HSeat Track · corrodedAFW - UPPER FLANGE OF TRACK HAS CORROSION OUT OF LIMITS. BLENDED AND REFINISHED. APPROVED PER MRB 767-949. TST 35,774. CYCLES, 6,431. (X)SDR AALA950041HDoor · damagedAFW - DAMAGE ON INNER SURFACE OF LT FORWARD NLG DOOR IN CRITICAL AREA. REPAIRED PER MRB 767-948. SRM 51-70-05 WITH 2 EXTRA PLIES. TST 35,774. CYCLES, 6,431. (X)SDR AALA950039HFloorbeam · corrodedAFW - CORROSION FOUND ON FORWARD FLANGE OF CABIN FLOORBEAM UPPER CHORD AT STA 287. REPAIRED PER MRB 767-951 AND SRM 53-00-51. TST 35,774. CYCLES, 6,431. (X)SDR AALA951175Fitting · corrodedAFW - FOUND INTERNAL CORROSION ON THE TEE FITTING LOCATED NEXT TO THE AFT FASTENER HOLE. TRIMMED OUT DISCREPANT AREA. APPLIED ALODINE AND PRIMED. FABRICATED AND INSTALLED FILLER, SHIM, AND STRAP USING 7075-T6 ALUMINUM. PRIMED AND PAINTED. ACCOMPLISHED AND SDR AALA951174Frame · corrodedAFW - FOUND AND BLENDED OUT CORROSION ON AFT CARGO FRAME WEB JUST BELOW INNER CHORD AT LBL 32. BLEND OUT GOES ALL OF THE WAY THROUGH THE WEB. FABRICATED AND INSTALLED REPAIR STRAP USING .040 INCH 7075-T6 ALUMINUM PRIMED REPAIR STRAP. APPROVED BY ENGINEERINGSDR AALA951173Skin Strap · corrodedAFW - TEAR STRAP CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND PRIMED BLENDED AREA. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-963. TST 41,966.02. CYCLES, 13,544. (X)SDR AALA951172Stringer · corrodedAFW - STRINGER CORRODED AROUND FASTENER HOLES. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND PRIMED BLENDED AREAS. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-961. TST 41,966.02. CYCLES, 13,544. (X)SDR AALA951171Floorbeam · corrodedAFW - FLOORBEAM CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED BLENDED AREAS. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 HALF-HARD STAINLESS STEEL. PRIMED AREA. APPROVED BY ENGINEERING PER MRB 767-956. TST 41,966.02. CYCLES, 1SDR AALA951170Floorbeam · corrodedAFW - FLOORBEAM CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREAS. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 HALF-HARD STAINLESS STEEL. PRIMED REPAIR STRAP. APPROVED BY ENGINEERING PER MRB 767-955. TST 41SDR AALA951169Floorbeam · corrodedAFW - FLOORBEAM CORRODED. AFTER BLENDING, FOUND DAMAGE BEYOND SRM LIMITS. ALODINED AND FILLED BLENDED AREAS. FABRICATED AND INSTALLED A REPAIR STRAP USING .050 INCH 301 HALF-HARD STAINLESS STEEL. PRIMED AND PAINTED. REPAIR ACCOMPLISHED. APPROVED BY ENGINSDR AALA951167Floorbeam · corrodedAFW - FLOORBEAM CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND PRIMED BLENDED AREAS. APPROVED FOR CONTINUED SERVICE IN NOTED CONDITION BY ENGINEERING PER MRB 767-953. TST 41,966.02. CYCLES, 13,544. (X)SDR AALA951160Strap · corrodedAFW - FAIL SAFE STRAP LOCATED ON THE FORWARD SIDE OF THE AFT CARGO DOOR CUT-OUT CORRODED JUST BELOW 533R AND JUST BELOW 532R. BOTH EXCEEDED SRM LIMITS AFTER BLENDING. ROTOPEENED, PRIMED, AND PAINTED BLENDED AREAS. APPROVED FOR CONTINUED SERVICE BY ENGINEERISDR AALA951159Sill · corrodedAFW - INNER CHORD CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. REINSTALLED FASTENERS WITH SHIM AS REQUIRED AFTER ALODING BLENDED AREAS. APPROVED BY ENGINEERING WITH NOTED CONDITION PER MRB 767-959. TST 41,966.02. CYCLES, 13,544. (X)SDR AALA951158Door Frame · corrodedAFW - FOUND CORROSION ON THE FORWARD SIDE OF THE VERTICAL LEG OF THE INNER CHORD. ALODINED BLENDED AREA AND REINSTALLED FASTENERS. APPROVED FOR CONTINUED SERVICE BY ENGINEERING PER MRB 767-958. TST 41,966.02. CYCLES, 13,544. (X)SDR AALA951156Seat Track · corrodedAFW - FOUND CORROSION ON THE SEAT TRACK OUTBOARD FLANGE AT LBL 11 AND ON THE INBOARD FLANGE AT RBL 11. FLAP PEENED BLENDED AREAS. PRIMED BLENDED AREAS. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-957. TST 41,944.02. CYCLESDR AALA951155Skin · corrodedAFW - LOWER FUSELAGE SKIN OUTER SURFACE UNDERNEATH VHF ANTENNA CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. REINSTALLED ANTENNA WITH NEW FASTENERS. APPROVED BY ENGINEERING PER MRB 767-967. TST 41,944.02. CYCLES, 13,544. (X)SDR AALA951139Slide · scrappedLAX - DURING SLIDE SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE HAD NUMEROUS LEAKS AT UPPPER TUBE AND SEAM AREAS. SCRAPPED EMERGENCY EVACUATION SLIDE. (W)SDR AALA951124Slide · scrappedLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE FLOOR FOUND DETERIORATED AND SLIDE HAD POROSITY LEAKS. SCRAPPED EMERGENCY EVACUATION SLIDE. (M)SDR AALA951110Eel Base · brokenSFO - DURING OVERNIGHT CHECK, EMERGENCY LIGHT IN MID GALLEY BROKEN/INOPERATIVE. REPLACED EMERGENCY LIGHT BASE AND LENS AT MID GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA951102Floor Beam · corrodedAFW - FORWARD FLANGE OF THE CABIN FLOOR BEAM UPPER CHORD CORRODED. DAMAGED AREA FOUND TO BE BEYOND SRM LIMITS AFTER BLENDING. ACCOMPLISHED REPAIRED PER SRM 53-00-51 FIG 202 EXCEPT WITH THE OUTBOARD VERTICAL LEG OF THE REPAIR ANGLE JOGGED DOWN BELOW THE -45 ASDR AALA951123Slide · scrappedLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE FLOOR FOUND DETERIORATED. SCRAPPED EMERGENCY EVACUATION SLIDE. (M)SDR AALA951278Seat Track · corrodedAFW - THE OUTER HORIZONTAL FLANGE OF SEAT TRACK CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. REFINISHED BLENDED AREA PER SRM 53-00-52 FIG 101. APPROVED FOR CONTINUED SERVICE BY ENGINEERING PER MRB 767-949. (M)SDR AALA951280Floor Beam · corrodedAFW - FLOOR BEAM AT STATION 347 RBL 48 TO RBL 78 HAS CORRODED BEYOND SRM LIMITS. BLENDED OUT CORROSION, ALODINED BLENDED AREAS. FILLED WITH BMS 5-92. FABRICATED STAINLESS STRAP. PRIMER COATED AND INSTALLED REPAIR STRAP WET. (M)SDR AALA951084Eel Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT AT PAX SEAT 24HJ INOPERATIVE. RESECURED LOOSE EMERGENCY EXIT LIGHT CONNECTOR AT PASSENGER SEAT 24HJ. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA951044Skin · corrodedAFW - FUSELAGE SKIN FOUND CORRODED. REFINISH BLENDED AREA. FABRICATE AND INSTALL DOUBLER .071 THICK PER 767 SRM 53-00-01 FIGURE 201. APPLY CORROSION INHIBITING COMPOUND TO THE INTERIOR OF REPAIR PER ENGINEERING MRB 767-234. (M)SDR AALA951042Skin · corrodedAFW - FUSELAGE SKIN UNDER ANTENNA HAS CORROSION BEYOND SRM LIMITS AFTER BLENDOUT. REFINISH BLENDED AREA PER 767 SRM 53-00-01 FIG 101 AND ENGINEERING MRB 767-238. (M)SDR AALA951041Stringer · corrodedAFW - STRINGER CORRODED UNDER PRODUCTION SPLICE. FABRICATE A NEW SPLICE 3.25 INCHES LONGER. INSTALLED AND FINISH WITH FAY SURFACE SEALANT PER 767 SRM AND ENGINEERING MRB 767-940. (M)SDR AALA951040Frame · corrodedAFW - FRAME WEB CORRODED BEYOND SRM LIMITS AFTER BLEND-OUT. FABRICATE DOUBLER 0.040 INCH THICK FROM 7075-T6 AND INSTALL WET WITH BMS 5-25 SEALANT PER B767 SRM AND ENGINEERING MRB 767-237. (M)SDR AALA951039Floor Beam · corrodedAFW - FLOOR BEAM CORRODED BEYOND LIMITS SRM AFTER BLEND-OUT. INSTALL ANGLE 0.10 INCH THICK 7075-T6 EXTRUSION WET WITH BMS 5-95 FAY SURFACE SEALANT PER B767 SRM AND ENGINEERING MRB 767-943. (M)SDR AALA951038Skin · gougedAFW - LEFT OUTBOARD PYLON SKIN BOTTOM EDGE, HAS GOUGE BEYOND SRM LIMITS AFTER BLEND-OUT. REFINISH BLENDED AREA PER B767-SRM. APPROVED FOR CONTINUED SERVICE PER ENGINEERING MRB 767-946. (M)SDR AALA951037Floor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION BEYOND SRM LIMITS AFTER BLEND OUT. REFINISH BEAM PER B767-SRM. BEAM IS SATISFACTORY FOR CONTINUED SERVICE PER ENGINEERING MRB 767-942. (M)SDR AALA951036Skin · corrodedAFW - TEAR STRAP ON FUSELAGE SKIN CORROSION OUT OF LIMITS AFTER BLEND-OUT. INSTALL A TAPERED SHIM WET WITH SEALANT AND CORROSION INHIBITING COMPOUND PER B767 SRM AND ENGINEERING MRB 767-935. (M)SDR AALA951033Eel Connector · defectiveSFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT 24H INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR PIN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA951030Eel Connector · defectiveSFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH LIGHTING AT SEAT 24 A/B INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT CONNECTOR PIN AT 24 A/B. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA951046Stringer · corrodedAFW - STRINGERS ARE CORRODED UNDER THE PRODUCTION SPLICE JUST AFT OF FRAME 1307. REMOVED EXISTING SPLICE. FABRICATE NEW SPLICE 5 INCHES LONGER. REFINISH AND INSTALL REPAIR SPLICE WITH FAY SURFACE SEALANT PER 767 SRM AND ENGINEERING MRB 767-932. (M)
Back to Boeing 767-223