Boeing 767-223

Service difficulty reports · 2,039

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '767223'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA952043Floor Beam · corrodedFOUND FLOOR BEAM CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREAS. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301.5 HARD STAINLESS STEEL. PRIMED REPAIR STRAP AND FLOOR BEAM APPROVED BY ENGINEERING PER MRB 767-1Dec 7, 1995 · N338AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA952055Skin · corrodedAFW - WING BOX UPPER SKIN FOUND CORRODED AT AFT DRAIN LOCATION. REMOVED FASTENERS IN CORRODED AREA. REMOVED CORROSION, EDDY CHECKED FOR CRACKS. SPOT FACED FLAP PEENED AREA AND ALODINED. REINSTALLED FASTENER, APPLIED FUEL BARRIER PER AA SPEC P5-54. APPLIEDDec 6, 1995 · N316AA · Boeing 767223 · Wing, Plate/SkinSDR AALA952054Skin · gougedAFW - FOUND AND BLENDED SMALL GOUGE IN THE EXTERNAL SURFACE OF THE FUSELAGE SKIN. AFTER BLENDING FOUND THE BLENDOUT EXCEEDS SRM MAX ALLOWABLE LIMITS. INSURED NO FASTENER OR FASTENER HOLE DAMAGE WAS PRESENT. INSURED NO CORROSION OR CRACKING WAS PRESENT. REFDec 6, 1995 · N316AA · Boeing 767223 · Fuselage Main, Plate/SkinSDR AALA952053Skin · delaminatedAFW - ULTRASOUND INSPECTION INDICATES .5 INCH INTERPLY DELAMINATION IN SKIN APPROX 1 INCH FROM THE L/E OF THE LEFT ELEVATOR. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-1070. REINSPECTION AT NEXT MBV. (M)Dec 6, 1995 · N316AA · Boeing 767223 · Elevator, Plate/SkinSDR AALA952052Skin · delaminatedAFW - ULTRASOUND INSPECTION INDICATES .5 INCH DIAMETER INTERPLY DELAMINATION APPROX 50 PERCENT OF ORIGINAL THICKNESS ON THE SKIN APPROX 1 INCH FROM THE LEADING EDGE OF THE RT ELEVATOR. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRBDec 6, 1995 · N316AA · Boeing 767223 · Elevator, Plate/SkinSDR AALA952051Door Sill · corrodedAFW - FOUND AND BLENDED OUT CORROSION ON THE AFT CARGO DOOR OPENING LOWER MAIN SILL UPPER CHORD. FOUND BEYOND SRM LIMITS AFTER BLENDING. INSURED THAT NO FASTENER OR FASTENER HOLE WAS PRESENT. INSURED THAT NO FURTHER CORROSION OR CRACKING WAS PRESENT. REFINDec 6, 1995 · N316AA · Boeing 767223 · Fuselage Miscellaneous StructureSDR AALA952050Floor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION ON UPPER SURFACE. ALODINED BLENDED AREA, FILLED BLENDOUT. FABRICATED AND INSTALLED REPAIR STRAP WING .050 INCH 301.5 HARD STAINLESS STEEL. APPLIED PRIMER, APPROVED BY ENGINEERING AND ACCOMPLISHED PER MRB 767-1073. (M)Dec 6, 1995 · N316AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA952049Floor Beam · corrodedFOUND THREE SPOTS OF CORROSION ON FLOOR BEAM TOP CHORD. HOLES WERE DRILLED TO REMOVE THE DEEP CORROSION PER SRM. TWO HOLES ARE 0.090 INCH TOO CLOSE PER SRM. FLOOR BEAM APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-1071. (M)Dec 6, 1995 · N316AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA952048Skin · delaminatedAFW - ULTRA SOUND INSPECTION INDICATES INTERNAL DELAMINATION 1.7 INCH LONG AND .75 INCH WIDE ON RT ELEVATOR LEADING EDGE LOWER SKIN. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-1069. FOLLOW UP INSPECTION AT NEXT MBV. (M)Dec 6, 1995 · N316AA · Boeing 767223 · Elevator, Plate/SkinSDR AALA951976Floor Beam · corrodedAFW - FOUND FLOOR BEAM CORRODED BEYOND SRM LIMITS AFTER BLENDING. ALODINED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 HALF HARD STAINLESS STEEL. APPROVED BY ENGINEERING EPR MRB 767-1067. (M)Nov 16, 1995 · N327AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951975Floor Beam · corrodedAFW - FLOOR BEAM FOUND CORRODED, BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP, USING .050 INCH 301 HALF HARD STAINLESS STEEL. APPROVED BY ENGINEERING PER MRB 767-1064. (M)Nov 16, 1995 · N327AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951973Floor Beam · corrodedAFW - FLOOR BEAM AT STATION 287 RBL 30 TO RBL 64 HAD CORROSION BLENDED BEYOND SRM LIMITS. REMOVED CORROSION, PRIMED. FILLED WITH BMS 5-95, FABRICATED AND INSTALLED REPAIR STRAP. (M)Nov 16, 1995 · N327AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951972Floor Beam · corrodedAFW - FLOOR BEAM AT RBL 11.06 STATION 955 HAD CORROSION REMOVED BEYOND SRM LIMITS. BLENDED CORROSION. CHECKED, NO CRACKS. REFINISHED AREA CONTINUED IN SERVICE. (M)Nov 16, 1995 · N327AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951974Skin · corrodedAFW - HEAVY CORROSION REMOVED ON CENTER WING UPPER SKIN AT AFT DRAIN LOWER CHORD TO FLOOR BEAM T-EXTRUSION WAS CUT AND REMOVED. BLENDED AREAS OF CORROSION AND TREATED, PRIMED AND PAINTED. FABRICATED T-EXTRUSION REPAIR. (M)Nov 13, 1995 · N327AA · Boeing 767223 · Wing, Plate/SkinSDR AALA951894Chord · corrodedAFW - FOUND AND BLENDED CORROSION IN THE UPPER SURFACE OF THE CHORD IN TWO AREAS. THE FWD BLEND-OUT IS WITHIN LIMITS, HOWEVER, DURING ULTRASONIC THICKNESS CHECK, A THICKNESS OF APPROXIMATELY 0.140 INCH WAS INDICATED EVEN THOUGH MINIMAL MATERIAL WAS REMOVED. Nov 2, 1995 · N335AA · Boeing 767223 · Fuselage Miscellaneous StructureSDR AALA951893Floor Beam · corrodedAFW - REMOVED CORROSION ON FLOOR BEAM. AFTER BLENDING, FOUND BEYOND SRM LIMITS. ALODINED AND BLENDED. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 1/2 HARD STAINLESS STEEL. INSTALLATION APPROVED BY ENGINEERING PER MRB 767-1050. (X)Nov 2, 1995 · N335AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951892Skin · corrodedAFW - WING BOX UPPER SKIN HAS CORROSION REMOVED. T-ANGLE AT RBL 74.81 WAS CUT TO PROVIDE AND FACILITATE CORROSION REMOVAL. FABRICATED AND INSTALLED REPAIR PER INSTRUCTIONS AT MRB 767-1054. TST, 33,946.03. CYCLES, 6,219. (X)Nov 2, 1995 · N335AA · Boeing 767223 · Wing, Plate/SkinSDR AALA951878Light · defectiveSFO - DURING OVERNIGHT CHECK, RIGHT AFT DOOR EMERGENCY EXIT BULKHEAD LIGHT INOPERATIVE. REPLACED RIGHT AFT EMERGENCY EXIT BULKHEAD LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Oct 31, 1995 · N315AA · Boeing 767223 · Emergency LightingSDR AALA951836Eel Wire · brokenSFO - DURING OVERNIGHT CHECK, RT FORWARD GALLEY EMERGENCY FLOOR LIGHT FOUND INOPERATIVE. REPAIRED BROKEN EMERGENCY FLOOR LIGHT WIRE BY RT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (X)Oct 22, 1995 · N339AA · Boeing 767223 · Emergency LightingSDR AALA950054HFitting · damagedAFW - EDGE DAMAGE BEYOND SRM 57-20-90-1 FIG 101 DETAIL V LIMITS. BLENDED DAMAGED AREA, NDT INSPECT, FLAP PEEN AND RESTORE FINISH PER ENGINEERING MRB 767-1034. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Wing Miscellaneous StructureSDR AALA950053HFloor Beam · corrodedAFW - FOUND CORRODED BEYOND LIMITS. CUT OUT DAMAGED FLOOR BEAM AND INSTALLED REPAIR SPLICE PER ENGINEERING MRB 767-1031. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA950052HFail/Safe Strap · corrodedAFW - FORWARD CARGO DOOR FAIL/SAFE STRAP HAD CORROSION BEYOND SRM LIMITS. REMOVED CORROSION AND REPLACED FASTENERS PER ENGINEERING MRB 767-1023. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Cargo/Baggage DoorsSDR AALA950051HStringer · corrodedAFW - REMOVED STRINGER SECTION, CORRODED BEYOND SRM LIMITS. FABRICATE LONGER SPLICE FROM SAME MATERIAL TYPE AND SHAPE PER ENGINEERING MRB 767-1032. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Fuselage Main, Longeron/StringerSDR AALA950050HFloor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION BEYOND LIMITS. FABRICATED REPAIR DOUBLER FROM 0.050 CRES STEEL AND INSTALL WET WITH BMS 5-95 SEALANT PER ENGINEERING MRB 767-1030. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA950049HSkin · corrodedAFW - WING BOX SKIN HAS CORROSION BEYOND SRM LIMITS. BLENDED AND APPROVED FOR CONTINUED SERVICE PER ENGINEERING MRB 767-1029. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Wing, Plate/SkinSDR AALA950048HFloor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION BEYOND SRM LIMITS. FABRICATE REPAIR DOUBLER FROM 0.050 CRES AND INSTALLED WET WITH BMS 5-95 SEALANT PER ENGINEERING MRB 767-1028. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA950047HFloor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION BEYOND SRM LIMTS. FABRICATE REPAIR STRAP FROM 0.050 THK CRES AND INSTALL WET PER ENGINEERING MRB 767-1027. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA950046HFloor Beam · corrodedAFW - FLOOR BEAM HAS CORROSION BEYOND SRM LIMITS. FABRICATED REPAIR DOUBLER FROM .050 STAINLESS STEEL INSTALLED WET WITH BMS 5-95 SEALANT PER ENGINEERING MRB 767-1026. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA950045HFloor Beam · corrodedAFW - FOUND FLOOR BEAM HAS CORROSION BEYOND LIMITS. ALODINED, FILLED WITH BMS 5-92 SEALANT. INSTALLED REPAIR STRAP WET WITH BMS 5095 SEALANT, PRIMED AND PAINTED PER ENGINEERING MRB 767-1025. (M)Oct 12, 1995 · N312AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951778Eel Connector · inoperativeSFO - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE BETWEEN ROWS 31 AND 37 ON THE RT SIDE. REPAIRED CONNECTOR ON EMERGENCY EXIT FLOOR PATH LIGHTS. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Oct 11, 1995 · N338AA · Boeing 767223 · Emergency LightingSDR AALA951770Slide · defectiveLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE HAD SEAM DEFECTS AND POROSITY LEAKS. EMERGENCY EVACUATION SLIDE SCRAPPED. (M)Oct 10, 1995 · N2FOR · Boeing 767223 · Escape SlideSDR AALA951757Eel Connector · looseSFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT AT PASSENGER SEAT 4B FOUND INOPERATIVE. RESECURED LOOSE EMERGENCY EXIT LIGHT CONNECTOR AT PASSENGER SEAT 4B. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Oct 5, 1995 · N334AA · Boeing 767223 · Emergency LightingSDR AALA951703Slide Raft · defectiveLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE RAFT SEPARATED AT LEFT ASPIRATOR TUBE. EMERGENCY EVACUATION SLIDE RAFT ROUTED TO VENDOR FOR REPAIR. (M)Sep 20, 1995 · Boeing 767223 · Life RaftSDR AALA951702Slide Raft · defectiveLAX - DURING SHOP TEST DEPLOYMENT, EMERGENCY EVACUATION SLIDE RAFT UPPER AND LOWER TUBES FOUND TORN. EMERGENCY EVACUATION SLIDE RAFT ROUTED TO VENDOR FOR REPAIR. (M)Sep 20, 1995 · Boeing 767223 · Life RaftSDR AALA951675Floor Beam · corrodedCORROSION FOUND ON FLOOR BEAM. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 HALF HARD STAINLESS STEEL. APPROVED BY ENGINEERING PER MRB767-1009. (M)Sep 15, 1995 · N305AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951673Skin · corrodedAFW - FOUND AND BLENDED OUT DAMAGE ON THE INNER SURFACE OF FUSELAGE SKIN. THE BLEND OUT IS APPROXIMATELY 1 INCH BY 2 INCHES WITH APPROX .050 MATERIAL REMAINING. THE DAMAGE IS UNDERNEATH STRINGER 38L. REFINISHED AND INSTALLED A FILLER. APPROVED BY ENGINEERISep 15, 1995 · N305AA · Boeing 767223 · Fuselage Main, Plate/SkinSDR AALA951669Splice · corrodedAFW - FOUND CORROSION ON STRINGER SPLICE, STRINGER 35L WAS TRIMMED BACK 1.5 INCHES TO REMOVE THE CORRODED AREA. FABRICATED AND INSTALLED A NEW SPLICE PIECE IDENTICAL TO OLD USING THE SAME MATERIAL TYPE AND SHAPE EXCEPT THAT NEW PIECE IS LONGER BY THE AMOUNT RSep 15, 1995 · N305AA · Boeing 767223 · Fuselage Miscellaneous StructureSDR AALA951665Fail Safe Strap · corrodedAFW - FOUND AND BLENDED OUT CORROSION IN FWD LOCATIONS ON THE UPPER SURFACE OF THE FAIL SAFE CHORD. REFINISHED AND INSTALLED SHIMS AS REQUIRED UNDER STRINGER APPROVED BY ENGINEERING PER MRB 767-1014. (M)Sep 15, 1995 · N305AA · Boeing 767223 · Fuselage Miscellaneous StructureSDR AALA951660Frame · crackedAFW - FOUND CRACK IN THE 146T1501-3 FRAME AND THE 146T1352-14 ANGLE ON THE FRAME. THE CRACK RUNS FROM THE CUTOUT IN THE FRAME AND ANGLE TO A FASTENER HOLE ABOVE THE CUTOUT. REMOVED CRACKED AREA. REMOVED FASTENERS AS REQUIRED. TREATED AND PRIMED AREA OVERSISep 15, 1995 · N305AA · Boeing 767223 · Fuselage Main, FrameSDR AALA951658Skin · corrodedAFW - CORROSION REMOVED FROM CENTER WING UPPER SKIN. AFTER BLENDING, FOUND BEYOND LIMITS. REMOVED FASTENERS IN CORRODED AREAS. EDDY CHECKED FASTENER HOLES AND SPOTFACED. SHOT PEENED AND ALODINED AREAS. APPLIED BMS 10-11 SEALANT AND APPLIED FUEL BARRIER TOSep 15, 1995 · N305AA · Boeing 767223 · Wing, Plate/SkinSDR AALA951618Eel Module · defectiveSFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT RIGHT AISLE FROM PASSENGER SEAT ROW 31 AFT INOPERATIVE. REPLACED EMERGENCY FLOOR LIGHT CONTROL MODULE FOR RIGHT AISLE AFT CABIN AREA. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 10, 1995 · N338AA · Boeing 767223 · Emergency LightingSDR AALA951589Eel Contact · brokenSFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT AT PASSENGER SEAT 30H INOPERATIVE. REPLACED BROKEN EMERGENCY EXIT LIGHT CONTACT AT PASSENGER SEAT 30H. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 3, 1995 · N324AA · Boeing 767223 · Emergency LightingSDR AALA951542Stringer · corrodedAFW - FOUND STRINGER 37L CORRODED BETWEEN STATION 399 AND 434. DAMAGE IS WITHIN 20 INCHES OF A STRINGER SPLICE. REPAIRED PER SRM 53-00-03-2 FIG 202. APPROVED BY ENGINEERING PER MRB 767-996. (M)Aug 25, 1995 · N308AA · Boeing 767223 · Fuselage Main, Longeron/StringerSDR AALA951541Floor Beam · corrodedAFW - FLOOR BEAM IN CABIN CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301.5 HARD STAINLESS STEEL. APPROVED BY ENGINEERING PER MRB 767-990. (M)Aug 25, 1995 · N308AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951540Skin · corrodedAFW - CORROSION FOUND ON CENTER WING UPPER SKIN AT AFT DRAINS. REMOVED FASTENERS IN CORRODED AREAS AND REMOVED CORROSION. EDDY CHECKED BLENDED AREAS AND FASTENER HOLES. NO CRACKS FOUND. SPOT FACED FASTENER HOLES. ROTOPEENED BLENDED AREAS. INSTALLED FASTEAug 25, 1995 · N308AA · Boeing 767223 · Wing, Plate/SkinSDR AALA951539Keel Beam · corrodedAFW - LEFT PANEL FLANGE OF KEEL BEAM CORRODED. AFTER BLENDING FOUND BEYOND SRM LIMITS. ROTOPEENED AND ALODINED BLENDOUT. REFINISHED AREA PER SRM 53-50-12 FIG 101. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MBB 767-1002. (M)Aug 25, 1995 · N308AA · Boeing 767223 · Fuselage Main, KeelSDR AALA951538Floor Beam · corrodedAFW - FLOOR BEAM CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 AND A HALF HARD STAINLESS STEEL. APPROVED BY ENGINEERING PER MBB 767-991. (M)Aug 25, 1995 · N308AA · Boeing 767223 · Fuselage Main, Floor BeamSDR AALA951537Stringer · corrodedAFW - STRINGER 39R CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. REFINISHED BLENDED AREAS PER SRM 53-00-03 FIG 101. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-995. (M)Aug 25, 1995 · N308AA · Boeing 767223 · Fuselage Main, Longeron/StringerSDR AALA951536Splice · corrodedAFW - STRINGER 38L FOUND CORRODED IN FORWARD CARGO. STRINGER TRIMMED BACK SEVEN INCHES TO REMOVE CORROSION. FABRICATED AND INSTALLED NEW SPLICE FROM .040 INCH MATERIAL IDENTICAL TO THE OLD PIECE EXCEPT THE NEW PIECE WAS LONGER BY THE AMOUNT REMOVED FROM THE Aug 25, 1995 · N308AA · Boeing 767223 · Fuselage Miscellaneous StructureSDR AALA951535Keel Beam · corrodedAFW - KEEL BEAM PANEL FLANGE CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ROTOPEENED BLENDED AREAS. REFINISHED BLENDED AREA PER SRM 53-50-12 FIG 101. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-999. (M)Aug 25, 1995 · N308AA · Boeing 767223 · Fuselage Main, Keel
Back to Boeing 767-223