SDR P5CA2020031900129Fire Detector · brokenFOUND THE TS00682 FIRE DETECTOR ASSY CONNECTOR BROKEN.(<P>IAW AMM 26-11-02-024-001 AND AMM 26-11-02-424-033 REV. 129 REPLACED FIRE DETECTOR AT NO. 1 ENG (TS00682). IAW AMM 26-11-02-424-033 REV. 129 PERFORMED INSTALLATION TEST AND RESULT WAS SATISFACTORY.</P>)SDR P5CA2020031900130Signal Cond Unit · failedFOUND THE ENGINE VIBRATION MONITOR FUNCTION FAIL.(<P>IAW AMM 77-31-03-004-002-1-100, 77-31-03-404-004-1-100 REV. 129 REPLACED THE SIGNAL CONDITIONER. IAW AMM 77-31-00-715-001-1-100, 77-31-00-705-103-1-100 REV. 129 PERFORMED OPERATIONAL TEST AND SELF TEST. RESUSDR P5CA2020031900131Diode · defectiveFOUND THE APU INOP.(<P>IAW SRM 24-31-02, 49-00-04 REV. 28 AND WDM 24-32-41, 49-14-11, 49-15-11, 49-41-11, 49-61-11 REV. 28 PERFORMED WIRING CHECK, THE RESULT WAS SATISFACTORY. FOUND DIODE R65 APU SHUTDOWN ISOLATION FUNCTION. IAW WDM 49-61-11 REV. 28 AND SWPM 2SDR UIEA2020031700463Sensor · defectiveAPU PNEUMATIC SYS INOP (APU BLEED VALVE)(<P>TRANSFERED TO DMI 125811 IAW MEL 36-11-04 CAT "C", EXP 25 MAR 20. PLACARD INSTALLED.</P><P>LP 1120068 - M6: REMOVED AND REPLACED APU PT2 SENSOR IAW AMM 49-61-04. TEST OK. THIS CLEARS MDDR 125811.</P>)SDR UIEA2020031700453Bleed Air Sys · malfunctionedPRIOR TO BLOCKOUT APU BLEED PRESSURE DROPPED TO 5 PSI. UNABLE TO CLEAR AFTER RE-STARTING APU (SAME ISSUE EXISTS).(<P>PERFORMED AUX POWER CONTROL UNIT BITE TEST IAW AMM 49-61-05. RESTART OF APU OPS NORMAL WITH 30PSI WITH PACKS RUNNING.</P>)SDR UIEA2020031200434Start Valve · stuck#1 ENG START VALVE STUCK IN THE OPEN POSITION.(<P>REMOVED AND REPLACED START VALVE IAW AMM 80-11-02. OPS CHECKS GOOD IAW AMM 71-00-00. PERFORMED 3 SUCCESSFUL STARTS OF THE LH ENGINE IAW AMM 71-00-00.</P>)SDR UIEA2020031100432Controller · malfunctionedSTATUS MSG CARGO A/C CONTROLLER.(<P>BIT L/H PACK TEMP CONTROLLER, IAW B767 AMM 21-51-00. OPS GOOD.<BR /></P>)SDR UIEA2020031000422Unknown · malfunctionedAT T/O AND CLIMB, POWER L ENGINE VIB 3.8 EVENT RECORDED.(<P>PERFORMED INSPECTION FOR ENGINE #1 IAW FIM 71-05 FT 853. NO DEFECTS NOTED AT THIS TIME PER FIM. THERE IS NO VIBRATION LIMITS DURING TRANSIENT (CHANGING ENGINE SPEEDS).</P>)SDR UIEA2020031000425Oxygen Mask · frayedCAPT'S O2 MASK SUPPLY HAS FRAYED COVER.(<P>REMOVED AND REPLACED CAPT'S O2 MASK ASSY IAW AMM 35-11-04. OPS CHECK GOOD.</P>)SDR UIEA2020031000398Surge Valve · faultyAPU FAULT REVERSE FLOW APU INOP.(<P>TRANSFERRED TO DMI 125491 PER MEL 49-11-01A, CAT 'C'.</P><P>LP 1208396 ITEM M9: REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW AMM 49-53-01, OPS CHK AND LEAK CHK GOOD. THIS CLEARS DMI 125491.</P><P>LP 1208395: WHEN DOING TSDR UIEA2020030900397Control Unit · malfunctionedR FWD WINDOW EICAS MESSAGE.(<P>PERFORMED FIM 30-41 F/T 804 UP TO BLOCK 3, MOVED TO FIM 30-41-00/201 TASK 802 TO STEP E. PER TABLE 102 OF 30-41 FOUND RESISTANCE OK. PER STEP 2 OF TABLE 102. REPLACED RT WHCU IAW AMM 30-41-01. OPS NORMAL AT THIS TIME.</P>)SDR UIEA2020030900395Igniter · defectiveRH ENG REQUIRED 2 START ATTEMPTS. AFTER START, R ENG IGNITOR 1 STATUS MESSAGE.(<P>PERFORMED PIMU BITE TEST, VISUAL INSPECTION OF IGNITOR SHOWS BAD. REMOVED AND REPLACED RH ENG #2 IGNITOR IAW AMM 74-21-02. OPS CHKS GOOD IAW AMM 74-00-00.<BR /></P>)SDR UIEA2020030600394Sensor · faultyAPU INOP (PNUEMATICS P2 FAULT)(<P>TRANSFERRED TO DMI #125395 IAW MEL 49-11-01A, CAT 'C', DUE 15MAR20.</P><P>LP 1178078: REPLACED APU INLET P2 SENSOR. OPS CHK GOOD. CLOSED MDDR IAW AMM 49-61-04.</P>)SDR UIEA2020030600388Warning System · false activationUPON LANDING, R WINDOW HEAT EICAS MSG DISPLAYED AND THEN EXTINGUISHED.(<P>TROUBLESHOOT R WINDOW HEAT ISSUE I.A.W B767 FIM 30-41 FT 803/804. NO FAULTS NOTED AT THIS TIME, OPS CHECK GOOD.</P>)SDR UIEA2020030600393Warning System · false activationRIGHT FWD WINDOW EICAS MESSAGE AT TOUCHDOWN.(<P>PERFORMED R/H FWD WINDOW BITE TEST I.A.W FIM 30-41 FAULT TREE 804. TEST SUCCESSFUL.<BR /></P>)SDR UIEA2020030500376Warning System · false activationWX RADAR HSI MESSAGE AUTO TILT FAIL + 15 UP ON GROUND.(<P>PERFORMED WEATHER ANTENNA SYSTEM TEST IAW AMM 34-43-05. TEST PASS, NO MESSAGE.</P>)SDR UIEA2020030300368Warning System · false activationFWD EQUIP VALVE EICAS MSG ON LANDING.(<P>PERFORMED FIM TASK 21-58 FT 805. NO DEFECTS NOTED AT THIS TIME.</P>)SDR UIEA2020030200353Valve · faultyFWD/AFT CABIN TEMP EICAS MSG(<P>DEFERRED CABIN TEMP CONTROL SYS IAW MEL 21-61-01-02, DMI 125198, CAT 'C'.</P><P>LP 1208383 - M5: REMOVED AND REPLACED FWD TRIM VALVE IAW AMM 21-61-07.</P><P>LP 1208398 - M16: OPS SYSTEM TEST OK IAW AMM 21-61-01, CLEARED MDDR 125SDR UIEA2020022870338Door · openON CLIMB OUT PASSING 10,000 FT, A/C DEVELOPED LOUD AIR FRAME NOISE AND VIBRATION ON ACCELERATION TO 310 KNOTS. RETURN TO AIRPORT UNEVENTFUL, ON ARRIVAL FOUND RIGHT A/C PACK DOOR OPEN, LANDING UNEVENTFUL.(<P>REMOVED AND REPLACED PACK DOOR AND HARDWARE IAW 52-48SDR UIEA2020022100298Apu · shutdownAPU SHUTDOWN DURING USE.(<P>TRANSFERRED TO MDDR #124907 I.A.W MEL 49-11-01A, CAT 'C'.</P><P>LP 1190973, ITEM M10: REMOVED AND REPLACED AUXILIARY POWER UNIT IAW B767 AMM 49-11-01-004-001. OPS CHECK AND LEAK CHECK GOOD. THIS CLEARS MDDR 124907, MCC NOTIFIED. PLASDR UIEA2020022190281Igniter · failedATTEMPTED 2 STARTS ON RIGHT ENGINE. GOOD DUCT PRESSURE ROTATION, FUEL FLOWING IN SINGLE AND BOTH HAD NO LIGHT OFF.(<P>PERFORMED ENGINE RUN IAW AMM 71-00-00. ENGINE RUN GOOD. FAULTED RIGHT ENGINE IGNITION 2. TRANSFERRED TO MDDR 124867 IAW MEL 74-00-01A, CAT "A"SDR UIEA2020022080270Smoke Detector · false activationSTATUS CARGO DET AIR.(<P>REMOVED AND REPLACED SMOKE DETECTOR IAW AMM 26-11-02. OPS CHECK OK.</P>)SDR UIEA2020021900276Warning Message · false activation"RT FWD WINDOW HEAT" EICAS ON APP AND LDG REMAINED ON.(<P>PERFORMED OPS TEST OF RT FWD WINDOW HEAT AFTER RESETTING SYSTEM, IAW AMM 30-41-00. NO DEFECTS NOTED AT THIS TIME.<BR /></P>)SDR UIEA2020021700266Surge Valve · malfunctionedAPU AUTO SHUT DOWN WHEN PACK TURNED ON.(<P>REMOVED AND REPLACED APU SURGE CONTROL VALVE IAW AMM 49-53-01. OPS CHECK GOOD AT THIS TIME. </P>)SDR P5CA2020021700045Flashlight · inoperativeFLASHLIGHT AT L1 DOOR AREA RED LIGHT NOT FLASH.(<P>TRANSFERRED TO MDDR 124565 AS PER MEL 25-20-01, CAT E, DUE 11JUN2020.</P>)SDR UIEA2020021320242Sense Line · damagedRIGHT ENGINE PRV EICAS UPON CLIMB OUT WITH POWER AT CRUSE. EICAS WENT OUT, STATUS MESSAGE RIGHT ENGINE PRV REMAINS.(<P>TROUBLESHOT PER FIM 36-10 FT 847. FOUND RIGHT ENGINE PRV SENSE LINE DAMAGED. REPLACED DAMAGED PRV SENSE LINE. LEAK CHECK GOOD IAW B767 AMM 36SDR UIEA2020021310238Tru · malfunctionedEICAS MSG APU FAULT.(<P>TRANSFERRED TO MEL 49-11-01A, MDDR 124554 CAT C, DUE 21FEB20. DOWNGRADED TO ETOPS 60. </P><P>REF LOG PAGE 1187675 ITEM M5; REMOVED AND REPLACED TRU AS PER AM 24-32-01. OPS CHECK NORMAL, MDDR 124554 CLEARED.</P>)SDR UIEA2020021310232Oil System · lowR IDG VALVE STATUS MSG.(<P>PERFORMED BPCU BITE TEST IAW AMM 24-11-00, FOUND IDG HIGH RISE TEMP MSG ON R GEN POWER SYSTEM. PERFORMED R IDG OIL SERVICING IAW AMM 12-13-03. OPS CHECK GOOD. NO STATUS MSG PRESENT. NO BPCU STATUS MSG PRESENT.</P>)SDR UIEA2020021310236Warning Message · false activationR ENGINE PRV STATUS MSG.(<P>PERFORMED FIM FOR R ENGINE PRV SHOWN AND R ENG BLEED LIGHT, FOUND NO FAULTS FROM AIR SUPPLY MODULE. RAN THE RIGHT ENGINE AND NO MSG SHOWN. EICAS MSG CLEARED. OPS CHECK NORMAL IAW FIM 36-10 FT 847 AND AMM 71-00-00.</P>)SDR UIEA2020021310237Warning Message · false activationR ENG PRV EICAS MSG.(<P>MSG CLEARED AND OPS CHECK NORMAL AT THIS TIME IAW FIM 36-10 FT 847 AND AMM 71-00-00.</P>)SDR UIEA2020021320241Seal · missing3RD TIME WRITE UP, "R ENG PRV" EICAS. ACCOMPLISHED QRH. R ENG PRV STATUS REMAIN.(<P>ON #2 ENG, SWAPPED PRV AND HPSOV PER MX CONT REQUEST IAW B767 AMM 36-11-18 AND 36-11-07. PERFORMED ENGINE RUN, OPS CHECK NORMAL.</P><P>LP 1086917 - ITEM M3: <SPAN>PER MAINTENANSDR UIEA2020021090218Sensor · failedIN FLIGHT, LEFT BLEED PRESS 19, RIGHT BLEED PRESS 35. BOTH BLEED PRESS AT 20 ON GROUND.(<P>DEFERRED PER MEL 36-12-02-01, MDDR 124463, CAT 'C', DUE 19FEB20. LEFT ENG FAN AIR VALVE LOCKED AT INTERMEDIATE POSITION AS PER AMM 36-00-00/901.</P><P>LP 1169718 - ITEM SDR UIEA2020021100224Lamp · inoperativeBOTH DOME LIGHTS IN AFT COCKPIT INOP.(<P>RELAMPED 2 EA EMERGENCY LIGHT LAMPS IAW B767 AMM 33-51-41. OPS CK GOOD.<BR /></P>)SDR UIEA2020021080212Valve · failedL DUCT PRESSURE FLUCTUATES TO 0 DURING CLIMB, ACCOMPANIED WITH "L ENG BLEED OFF" (INTERMITTENT). NOTE: DURING CRUISE, RIGHT DUCT PRESSURE AT 35 AND LEFT AT 17.(<P>RAN FIM 36-10 FAULT TREE 837, REMOVED AND REPLACED FAN AIR VALVE PER AMM 36-11-16. RAN ENGINE, OPSDR UIEA2020021090217Controller · failedWITH LEFT ENGINE ANTI-ICE ON, COMPLETE LOSS OF LEFT AIR SYSTEM PRESSURE (I.E. PACK AND BLEED AIR EICAS IN CRUISE, L DUCT PRESS 18 PSI).(<P>AS PER FIM 36-10 FAULT TREE 837, REMOVED AND REPLACED PRV CONTROLLER ON LEFT ENGINE PER AMM 36-11-19. OPS CHECK LEFT ENGISDR UIEA2020020700203Warning Message · false activationFWD EQUIPMENT VALVE EICAS MESSAGE AFTER LANDING.(<P>PERFORMED FIM TASK 21-58 FAULT TREE 986. MESSAGE NO LONGER PRESENT.<BR /></P>)SDR UIEA2020020400182Shutoff Valve · malfunctionedDURING CLIMB AND DESCENT, L DUCT INTERMITTENTLY ZERO. ACCOMPANIED W/ L PACK OFF EICAS L ENG BLD OFF EICAS.(<P>LOG PAGE 1196915: REMOVED AND REPLACED L/H PRSOV IAW AMM 36-11-09, OPS AND LEAK CHECK GOOD. NO DEFECTS NOTED AT THIS TIME. <BR /></P>)SDR UIEA2020020300178Control Valve · failedCARGO A/C TEMP EICAS MESSAGES (FORWARD CARGO AIR CONDITIONING SYSTEM / (NOTIGY DISPATCH)) (<P>TRANSFERRED TO MDDR 124223 IAW MEL 21-28-01, CAT 'D'.</P><P>LP 1070867: REMOVED AND REPLACED FWD CARGO HEAT CONTROL VALVE IAW AMM 21-43-02. OPS CHECK NORMAL AT THSDR UIEA2020020310160Warning Message · false activationL DUCT PRESS DROPS TO 10 PSI WHEN L ENG ANT-ICE SELECTED.(<P>PERFORMED AIR SUPPLY BITE IAW 36-23-00, NO DEFECTS NOTED. PERFORMED VISUAL INSPECTION OF TAI AND ANTI-ICE DUCTING IAW 30-11-02, NO DEFECTS NOTED. PERFORMED ENGINE RUN & CYCLED ANTI-ICE SEVERAL TIMES,SDR UIEA2020020310163Status Message · false activationSTATUS MSG WX RADAR SYSTEM(<P>MESSAGE CLEARED AFTER OPS CHK PER AMM 34-43-00, OK FOR RTS.</P>)SDR UIEA2020020300180Status Message · false activationCARGO A/C TEMP STATUS MSG.(<P>PERFORMED OPERATION TEST ON CARGO A/C TEMP REF 21-28 FAULT TREE 804. SYS OK.<BR /></P>)SDR UIEA2020013100152Status Message · false activationCARGO A/C TEMP STATUS MESSAGE. PERFORMED AN OPS CHECK IAW AMM 21-28-00/705, OPS CHECKED GOOD.SDR UIEA2020020300181Status Message · false activationCARGO A/C TEMP STATUS MSG.(<P>PERFORMED BITE CHECK OF PACK TEMP CONTROLLER PER 21-51-00. NO FAULTS NOTED, STATUS MSG CLEARED.<BR /></P>)SDR UIEA2020012870134Shutoff Valve · malfunctionedLEFT PACK OFF, WILL NOT RESET. PERFORMED A CHECK OF THE LEFT PACK FLOW CONTROL SHUTOFF VALVE IAW AMM 21-00-00. RESEATED CONNECTORS D2770 D1598, D746 AND D20316, LT PACK SHUTOFF VALVE. PERFORMED BITE TEST IAW AMM 21-51-01. NO FAULTS.SDR UIEA2020012760126Duct · unknownAPU PNEUMATIC INOPERATIVE. REMOVED AND REPLACED APU AIR SURGE DUCT IAW AMM 49-53-01. OPS AND LEAK CHECKED GOOD.SDR P5CA2020012800021Switch · stickingCAPT'S O2 MASK RESET/TEST SWITCH STICKS WHEN TESTED, DOES NOT RETURN TO ORIGINAL POSITION.(<P>CLEANED RESET/TEST SWITCH AND CAPT'S O2 MASK, OPERATIONAL CHECKS OK IAW AMM 35-11-51.</P>)SDR UIEA2020012840120Shutoff Valve · failedDURING DESCENT, "L ENG BLEED OFF" CAUTION MESSAGE. REMOVED AND REPLACED HIGH PRESSURE SHUT OFF VALVE IAW AMM 36-11-07.SDR UIEA2020012840121Shutoff Valve · failedDURING DESCENT, "L WING ANTI-ICE" CAUTION MESSAGE. NOTED BY MX, CAUTION MSG IS ASSOCIATED WITH LT ENG HPSOV FAILURE, REMOVED AND REPLACED HIGH PRESSURE SHUT OFF VALVE IAW AMM 36-11-07.SDR UIEA2020012760128Connector · looseSTATUS MESSAGE FOR LT ENG HPSOV, INTERMITTENT EICAS MSG L ENG HPSOV. TROUBLESHOOTING PER AMM 36-11-06 AND WDM 36-11-03 AMM 36-11-04 FOUND WIRE CONNECTOR BLK 2 WAS LOOSE AS WELL AS BLK 1 AND BLK 3. SECURED THE TERMINAL WIRE IAW SWPM. NO LEAK OR FAULTS FOUND. OSDR UIEA2020012400117Wire · looseLEFT ENG BLEED EICAS MSG DISPLAYED WHEN LEFT ENG ANTI-ICE SELECTED.(<P>PERFORMED BITE CHECK FOR FAMV, FOUND L FAV, FAS LIGHT ON. OPENED T/R ON LEFT ENG AND FOUND TWO LOOSE WIRES. TIGHTENED WIRES, RAN ENG, NO MESSAGES PRESENT AT THIS TIME. VERIFIED BITE ON FAMV
Back to Boeing 767-306