SDR UALA2012021000806Trim Panel · brokenFLOOR MOLDING FIRST CLASS GALLEY BROKEN. TRIP HAZARD. SECURED FLOOR MOLDING.SDR UALA2012020800755Actuator · leakingLT OUTBOARD ELEVATOR PCA HAS RUNNING LEAK FROM SHAFT SEAL. SHOULD READ LEAKING FROM LT CENTER ELEVATOR PCA. PCA REMOVED. COMPLETED INSTALLATION OF LT CTR ELEV PCA.SDR UALA2012020800754Thrust Reverser · damagedNR 2 ENG LT REVERSER DAMAGED. THREE DAMAGED AREAS, TWO IN SLEEVE ACCOUSTICAL SKIN AND ONE ON INNER BARREL ACCOUSTICAL SKIN, MOST LIKELY DAMAGED FROM PREVIOUS BLOCKER DOOR OR FAIRING DEPARTURE. DENT IN SLEEVE 1.375" X 1.875" X .125" A-Y=11, CREASE IN SLEEVE 1SDR UALA2012020900777Connector · burnedNR 1 PYLON CONNECTOR TO MOTORIZED ISOLATION VALVE IS BURNED BETWEEN PINS. REMOVED & REPLACED CONNECTOR & BACKSHELL REF BOEING SWPM20-61-00 AND WDM78-34-11. PERFORMED OPS CHECK OF SYSTEM. CHECKS GOOD.SDR UALA2012020900772Power Supply · inoperativeTHE 19AB, 20AB EMER LIGHTS FLASH - *FIX DN. REPLACED POWER SUPPLY AND BATTERY ASSYS M1559 AND M737 AT SEAT 21A PER MM, TESTED AND OPS NORMAL.SDR UALA2012020700740Actuator · intermittentRUDDER TRIM INTERMITTENT, FLIGHT DIVERTED. REPLACED RUDDER TRIM ACTUATOR PER MM. REPLACED RUDDER TRIM CONTROL MODULE PER MM. OPS CHECKS GOOD.SDR UALA2012020900766Slide · faultyRT OVERWING SLIDE PACK BOARD COVER RELEASE TRIGGER NOT FULLY SEATED ON ARMING CAM. REMOVED AND REPLACED RT OVERWING SLIDE.SDR UALA2012020700741Module · faultyVERY SIGNIFICANT HARMONIC-VIBRATION BEING TRANSMITTED THRU FLAP HANDLE AS FLAPS APPROACH 5. REPLACED FLAP-SLAT SHUTOFF VALVE MODULE, MODULE INSTALLATION TEST CKS OK, NO LEAKS, NO VIBRATION FELT DURING SEVERAL FLAP EXTENSION CYCLES.SDR UALA2012020600703Pcu · out of adjust5 UNITS LEFT RUDDER TRIM NEEDED IN CLIMBOUT. FOUND LEFT RUDDER PCU OUT OF ADJUSTMENT. ADJUSTED PER MM. CHECKED ADJ OF CENTER AND RIGHT PCU. CHECKS NORMAL.SDR UALA2012020600724Pump · unknownNR 2 ENG FUEL PUMP REPLACEMENT.SDR UALA2012020600693Filter · leakingMAIN OIL FILTER WAS REPLACED AND ENGINE WAS MOTORED, BUT ENGINE STILL NEEDS 5 MIN ENGINE RUN, UNABLE TO RUN ENGINE DUE TO LACK OF HYDS. RAN ENGINE FOR 5 MINUTES, NO LEAKS FOUND.SDR UALA2012020600689Actuator · faultyRUDDER RATIO LIGHT & EICAS MSG, RTFL. FAULT BALL FOUND IN PCA POSTION ON BOTH RRCM'S. REPLACED RRCA WITH BORROWED PART S-N 1008. OPS CHECKS GOOD, NO FAULTS.SDR UALA2012020600690Slide · unserviceableLEFT WING OW SLIDE INFLATION HOSE KINKED AND TWISTED OUT OF LIMITS. REMOVED & REPLACED LEFT OVERWING SLIDE.SDR UALA2012020600717Transceiver · defectiveWXR WEAK MESSAGE INTERMITTENTLY DISPLAYED OI CAP AND F/O HSI. REPLACED WXR XCVR PER MM, CHECKS GOOD.SDR UALA2012020600716Antenna · failedWXR FAIL DSPLYD ON HSI. WXR FAIL WEAK DSPLYD ON HSI IN WXR TEST POS'N. CREW COMMENTS: WXR FAIL WEAK RT DISPLAYS. REPLACED WXR RADAR ANTENNA, ALL OPS CHECKS SATISFACTORY.SDR UALA2012020600718Regulator · leakingPRIOR TO COA 615671 FOUND O2 SYSTEM LEAKING WHEN SUPPLY WAS SHUTOFF. OXYGEN LEAK EXCEEDS LIMITS. OXY PRESS REG RPLC'D, OPS CK LEAK CKD SYS GOOD.SDR UALA2012020600685Connector · dirtyRIGHT EMERGENCY ESCAPE SQUIB FAILS TO TEST. CLEANED CONNECTOR. TESTS OKAY.SDR UALA2012020600688Feeder Cable · damagedCLEANERS VACUUMED UP PORTION OF EEL LIGHTING AFT OF DOOR 1L. REPLACED FEEDER CABLE. GROUND CHECKS NORMAL.SDR UALA2012020600712Battery Pack · dischargedEMERGENCY LIGHTS BLINKING ON LEFT SIDE OF CABIN. FOUND WHITE BATTERY PCN 585-4495 INOP AT SEAT 2AB. REPLACED BATTERY PACK AND OPS CHECK GOOD.SDR UALA2012020300669Blade · nickedNR 2 ENG HAS 1EA NICKED FAN BLADE ON FAN BLADES NR 26 AND 35. BLENDED NR 2 ENG BLADES NR 26 AND 35 PER MM.SDR UALA2012020600711Valve · faultyDIFFICULT TO CONTROL TEMP IN COCKPIT. MIX VALVE SHOWS FULL WARM WITH COLD AIR STILL BLOWING. FLT DECK TRIM VLV SHOWS WARM, BUT COLD AIR IS COMING IN, CREW CYCLED MASTER TRIM VLV AND OPERATED FLT DECK TRIM VLV IN MANUAL, NO HELP. REPLACED TRIM AIR VALVE.SDR UALA2012020300681Panel · wornLEFT ENGINE, OUTBOARD PYLON PANEL 436AL HAS FASTENER HOLE WORN OUT FASTENER JUST FALLS THROUGH. ROUND SMALL PANEL WITH 4 FASTENERS. REMOVED PANEL AND PLACED IN LOB. PARTS: 160-8839 311T3065-159 (DOOR ASSY) REPLACED OLD PANEL WITH NEW PANEL. SECURED ON PYSDR UALA2012020300662Servo Valve · faultyAIRFRAME VIBRATION. WITH CTR A-P ENGAGED VIBRATION FELT IN BOTH YOKES, NOT FELT IF USING LEFT OR RT AUTOPILOTS. CARRIED OUT BPCU BITE AND CARRIED OUT MCDP TESTS NO FAULTS NOTED. SERVICE TIP IS FOR ENGINES RUNNING IN FLIGHT, ON GROUND ENGINES OFF AP STILL HASDR UALA2012020200652Modulating Valve · faultyTEMPERATURE OSCILLATES + AND - 10 DEGREES IN BOTH CABIN & COCKPIT. NEEDS MORE TIME TO T/S. REPLACED ZONE TRIM AIR MODULATING VALVE PER MM, OPS TEST NORMAL.SDR UALA2012020300680Bleed Valve · faultyAPU BLEED VALVE WOULD NOT OPEN. REPLACED AND OPS CHECKED THE APU BLEED VALVE PER AMM AND THE IGV ACTUATOR PER AMM. OPS CHECKED GOOD.SDR UALA2012020300664Stop Fitting · damagedAFT CARGO DOOR AFT FRAME LWR STOP FITTING (NR 10) HAD INTERIM REPAIR ACCOMPLISHED DURING C-14 CHECK IN TPA PER EC-RA 5360-01181. DAMAGE CAREFULLY BLENDED REF EA PD67-53-065 & UAL EC-RA 5360-01181. PERFORMED HFEC INSPECTION OF BLENDED AREA. NO DEFECTS NOTED.SDR UALA2012020200650Slide · unserviceableRIGHT OVERWING SLIDE (PCN 649-9124 S-N PF0102) HOSE COLLAPSED & KINKED FROM SLIDE TO ELBOW. REMOVED & REPLACED RIGHT OVERWING SLIDE. SLIDE ARMING PERFORMED ON TASK CARD.SDR UALA2012020200648Target · missingMAIN E-E AND FWD E-E DOORS MISSING HIGH INDUCTANCE TARGET. INSTALLED NEW HYMU TARGETS ON FWD ACCESS AND E&E COMPART DOORS AND PERFORMED OPS CHECK. WORK PERFORMED IAW 767 AMM 52-71-01 AND 52-71-00 BY FN 601061 AND IQ Q868 ON NR 4165N00261.SDR UALA2012020200637Skin · damagedDAMAGE TO FUSELAGE SKIN BELOW FWD LWR CORNER OF BULK CARGO DOOR APROX 10" LONG X 4.5" WIDE LOCATED AT BS 1428 ABOVE & BELOW STRINGER S34L. MAJOR REPAIR ACCOMPLISHED. EVALUATED DENT & FOUND OUT OF LIMITS OF SRM. CUT OUT DAMAGE & ACP VISUAL & NDT INSP FOR CRASDR UALA2012020200622Skin · corrodedBS 1540 AT BL 0 AFT BULK CARGO COMPARTMENT INTERNAL FUSELAGE SKIN CORRODED AT DRAIN VALVE (N-R 4175N00498). MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE, FABBED AND INSTALLED DOUBLER AND FILLER AND PART MARKED PER SRM AND GNMM 1-01-007 ON NR 4175N00498.SDR UALA2012020200659Rub Strip · looseNR 2 ENG RUB STRIP LOOSE LEADING EDGE OF REV COWL. INTERIM REPAIR ACCOMPLISHED PER ECRA 7111-01296. CLEANED AREA WITH SOLVENT PER GPM. APPLIED 3 LAYERS OF ALUMINUM TAPE 2524-2-0200 TO DISCREPANT AREAS. TAPE TO BE RE-INSPECTED EVERY 25 HOURS BEGINNING PTT 8SDR UALA2012020200653Slide · obstructedLT OVERWING SLIDE CATCHES ON AFT DOOR OPENING ACTUATOR LINKAGE. REMOVED & REPLACED LT O/W SLIDE IAW B767-300 AMM. RE-ARMING ACCOMPLISHED ON TASK CARD 4165R607.SDR UALA2012020200632Light · inoperativeCABIN INTERIOR LT SIDE AT BS 1220 EMERGENCY EXIT LIGHT IS INOP. REPLACED AND OPS CHECKED THE AISLE LIGHT AT STA 1220 LT PER AMM AND INSPECTED. OPS CHECKED GOOD.SDR UALA2012020200631Light · inoperativeCABIN CEILING EMERGENCY EXIT LIGHT AT SEAT 28AB FOUND INOP (N-R 4165N00100). REPLACED AND OPS CHECKED THE AISLE LIGHT AT SEAT 28AB PER AMM AND INSPECTED. OPS CHECKED GOOD.SDR UALA2012020200630Light · inoperativeEEL LIGHT AT AISLE SIDE OF SEAT 28AB INOPERATIVE. REPLACED AND OPS CHECKED THE AISLE LIGHT AT SEAT 28AB PER AMM AND INSPECTED. OPS CHECKED GOOD.SDR UALA2012020200629Light · inoperativeLT SIDE STATION AT 1220 EEL LIGHT IS INOPERATIVE. REPLACED AND OPS CHECKED THE AISLE LIGHT AT STA 1220 LT PER AMM AND INSPECTED. OPS CHECKED GOOD.SDR UALA2012020200621Light · inoperativeEEL PATH LIGHT INOP AT FWD VIDEO CLOSET. REPLACED EEL LIGHT AT FWD VIDEO CLOSET, OPS CHECK GOOD PER AMM ON NR 4175N00542.SDR UALA2012020200625Relay · faultyLT OVERWING EMER LIGHT TEST NR 1 INTERMITTENT. REPLACED K838 SQUID TEST ONE RELAY IN P19 PANEL. OPERATIONAL TEST NUMEROUS TIMES ALWAYS TEST NORMAL.SDR UALA2012020200624Battery Pack · dischargedLT OVERWING SLIDE TEST LIGHT INTERMITTENT. REPLACED BATTERY PACK (CORRECTION). REPLACED LT OVERWING SLIDE BATTERY PACK.SDR UALA2012020200623Battery Pack · no testTEST 1 RIGHT SIDE SLIDE NO TEST. REPLACED RIGHT SIDE FWD SLIDE BATTERY PACK, TEST OKAY. ACCOMPLISHED CRITICAL STEP INSPECTION FOR INSTALLATION OF RT SLIDE BATTERY PACK. INSTALLED BATTERY PACK PER MM.SDR UALA2012020200633Slide · unserviceableRT OFF WING ESCAPE SLIDE INFLATION HOSE IS COLLAPSED AND APPEARS INTERNALLY DETERIORATED ALONG 80 PERCENT OF ITS LENGTH. REPLACED RT OFF-WING SLIDE PACK PER MM. ACCOMPLISHED RII INSPECTION, CRITICAL STEPS GROUP NR 1, OF RT OFF WING SLIDE INSTALLATION.SDR UALA2012020200628Light · inoperativeFLOOR EEL STRIP AT FWD FLT ATTENDANT STATION IS INOPERATIVE. RECONNECTED THE FWD FLOOR PROXIMITY CROSS AISLE STRIP PER AMM AND WDM AND PERFORMED THE OPS CHECK PER AMM AND INSPECTED. OPS CHECKED GOOD.SDR UALA2012020200620Nut · looseLANDING GEAR MONITOR STATUS EICAS MSG REPORTED BY CREW AFTER GEAR RETRACTION. TIGHTENED LOOSE NUT RT FWD NLG IDLER HINGE, TORQUED NUT PER AMM. ACCMP'D GEAR SWING SEVERAL TIMES PER AMM. EICAS MSG WAS CLEAR ON NR 4175N00193.SDR UALA2012013000606Monitor · faultyRT HYD SYSTEM QTY IS 0.02; R HYD QTY EICAS MSG DISPLAYED. SAMC TEXT: WITH RT QTY LOW LIGHT ALSO. TOMC MAINT TEXT: PER CREW, PUMP LOW PRESS LIGHTS DID NOT ILLUMINATE PRESSURE NORMAL. NO SIGNS OF EXTERNAL LEAKAGE. REPLACED HYD QTY MONITOR UNIT PER MM, QTY SYSDR UALA2012013000585Rvdt · faultyAFTER FLAP EXTENSION, GOT FLAP SLAT ELEC STATUS MSG AND DURING FLAP SLAT RETRACTION GOT T/E CAUTION LIGHT. REPLACED M548 SLAT TRANSDUCER RVDT PER MM 27-81-11 PAGE 412 AND ACP TESTS PER MM 27-51-00 PAGE 501 AND MM 27-81-00 PAGE 501 SYS PASSED OKAY.SDR UALA2012013000609Actuator · faultyLEFT ENG FUEL S-O VLV. PLEASE REPLACE LEFT ENG SPAR VLV ACTUATOR (V25) PER MM (MR28227) PRECAUTIONARY. CHK WITH ON LINE IPC FOR PROPER EFFECTIVITES. REPLACE LEFT ENG SPAR VLV ACTUATOR PER MM, OPS CHK GOOD.SDR UALA2012013000583Battery · dischargedEEL LEFT CENTER FLOOR STRIP AND CENTER CROSS AISLE FLOOR STRIP ARE INOP. REPLACED EEL BATTERY BY SEAT 22A. OPS CHECKS NORMAL.SDR UALA2012013000580Light · intermittentEMERGENCY PATH LIGHTS BY WINDOW EXIT LEFT SIDE 19A-B FLASH ON & OFF. CHECKED EEL FAULT. COULD NOT REPRODUCE, OK DURING GROUND CHECK.SDR UALA2012013000602O-Ring · leakingOIL DRIPPING RT ENG AFT OF PYLON. REPLACED O-RING ON DRAIN PLUG ON AC HYDRAULIC PUMP, RAN PUMP NO LEAKS NOTED.SDR UALA2012013000604Transceiver · inoperativeWX FAIL DISPLAYED ON NR 3 HSI(S). WXR TEST INOP. (1=CAPT, 2=1ST OFF, 3=BOTH). FOUND AS STATED DF PER MEL. ACP'D FAULT ISOLATION REF MM, WXR FAIL DISPLAYED ON EHSI, WRX UNIT DEAD, NO PWR. REPLACED WRX XCVR, SYSTEM TESTS OKAY.
Back to Boeing 767-322