SDR IPXA09655700Floorboard · damagedINSPECTION TYPE:N/A 2 HOLES IN FLOORBOARD POS 3R&4R REF DEF 397321. FABRICATE FLOORBOARD PER EO B767-5320-9693-F.SDR IPXA09655549Actuator · leakingINSPECTION TYPE: ETOP AFTER TAKEOFF L HYD QUANTITY LIGHT CAME ON FOLLOWED BY L SYS PRESS LIGHT. LEFT HYD QTY INDICATED 0.00.ATB TO CDG. FOUND LEAK AT FILTER CAP OF LEFT WING INBOARD SPOILER ACTUATOR. REMOVED AND REPLACED CAP P/N:1545661 AND O-RING P/N: NASSDR IPXA09655533Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL POS 11 DAMAGED. REPAIRED PER EO B767-5320-9693-E.SDR IPXA09655532Floor Panel · damagedINSPECTION TYPE:N/A MCD POS 10C FLOORING DAMAGED. REPAIRED PER EO B767-5320-9693-E.SDR IPXA09655521Floorboard · dentedINSPECTION TYPE:N/A MAIN CARGO FLOOR CENTER LINE POSITION 4 DENTED IN THREE SPOTS. REPAIRED PER EO-B767-5320-33101-A.SDR IPXA09655543Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. DAMAGE IS LOCATED AT MCD POS 11. MAJOR REPAIR. REMOVED FLOOR PANEL FROM MCD POS 11 FOR REPLACEMENT. FABBED FLOOR PANEL IAW EO B767-5320-9693B THROUGH STEP 6. INSPECTED, INSTALLED FLOOR PANEL IAW EO B767-5320-96SDR IPXA09655542Floor Panel · damagedINSPECTION TYPE:N/A MAIN CARGO FLOOR POS 4, CENTER PANEL HAS 2 AREAS THAT HAVE BEEN DAMAGED. REMOVED DAMAGED PER SRM 53-00-50-2 AND EO B767-5320-33101A. INSTALLED CORED & POTTED ALL 3 AREAS PER SAME EO. INSTALLED PLIES ON 1ST & 2ND DAMAGED. INSTALLED REPAISDR IPXA09655363Skin · damagedINSPECTION TYPE:N/A RT O/B GROUND SPOILER LWR SURFACE REPAIR. REPAIRED PER EO B767-5750-32318-B.SDR IPXA09655459Cylinder · damagedINSPECTION TYPE:6C OUTER CYLINDER INNER WALL FOUND SEVERAL AREA CHIPPED. RT MLG OUTER CYLINDER INNER WALL NICK MARKS REPAIR CUTOUT AS PER HX RS R32-11-36300 AND IPXA EO C-3210-33050-A.SDR IPXA09655857Stiffener · damagedBULK CARGO STA 1518 LBL 14 INCHES FLR WEB FWD SIDE ATT STIFFENER BENT. BULK CARGO STA 1518 LBL 14 INCHES FLOOR WEB FWD SIDE ATT STIFFENER REPLACED PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655456Spoiler · delaminatedINSPECTION TYPE:6C LT WING - NR 5 SPOILER PANEL FWD O/B CORNER DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-04 PARA 5G FIG 9 REV 43.SDR IPXA09655423Skin Panel · delaminatedINSPECTION TYPE:C EMP - VERTICAL STAB LT LWR EXTERIOR SURFACE AREA DELAMINATION. METAL HOT BOND REPAIR PERFORMED AS PER SRM 51-70-10 REPAIR 4 FIG 201 REV 43.SDR IPXA09655422Support Angle · crackedINSPECTION TYPE:C MEC- BS 246 CABIN FLOORBEAM FWD FACE L/G ALTERNATE DRIVE MOTOR SUPPORT ANGLE CRACKED AT LBL 25. (CRACK 1 INCH LENGTH). MEC- BS 246 CABIN FLOORBEAM FWD FACE L/G ALTERNATE DRIVE MOTOR SUPPORT ANGLE REPLACED AS PER SRM 51-10-02 AND SRM 51-40-0SDR IPXA09655421Fairing · chafedINSPECTION TYPE:C LT WING - I/B AILERON FWD UPPER L/E FAIRING CHAFE DAMAGED. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-17 PARA 4G FIG 18.SDR IPXA09655393Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1518 RBL 9 FLOOR WEB FWD SIDE ATT STIFFENER BENT. BULK CARGO STA 1518 RBL 9 FLOOR WEB FWD SIDE ATT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655392Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1480 LBL 9 FLOOR WEB FWD SIDE ATT STIFFENER BENT. BULK CARGO STA 1480 LBL 9 FLOOR WEB FWD SIDE ATT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655391Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1439 LBL 16 FLOOR WEB FWD SIDE ATT STIFFENER BENT. BULK CARGO STA 1439 LBL 16 FLOOR WEB FWD SIDE ATT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655377Skin · misrepairedINSPECTION TYPE:C FUSELAGE SURVEY SEQ 323-F1-04 BETWEEN BS 1427 TO BS 1435.25 AND STA 24L - 26L. AT BULK CARGO DOOR AREA PATCH FOUND. (REPAIR CURRENTLY WITH SURVEY SEQ 323-F1-05). SURVEY SEQ 323-F1-05 AT BULK CARGO DOOR SKIN REPAIRED CURRENTLY WITH SURVEY SSDR IPXA09655376Skin · activatedINSPECTION TYPE:C FUSELAGE SURVEY SEQ 323-F1-05 BETWEEN BS 1436.55 TO BS 1443.55 STR 24L TO 26L AT BULK CARGO DOOR SKIN AREA PATCH FOUND, NOT CORRELATED TO SRM. SURVEY SEQ 323-F1-05 AT BULK CARGO DOOR SKIN REPAIRED AT BETWEEN BS 1427 TO BS 1444 AND STR 24L - SDR IPXA09655349Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1461 LBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1461 LBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655348Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1502 LBL 20 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1502 LBL 20 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655347Web · bentINSPECTION TYPE:C BULK CARGO STA 1480 LBL 14 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1480 LBL 14 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655346Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1502 RBL 14 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1502 RBL 14 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655345Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1439 LBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1439 LBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655344Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1502 RBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1502 RBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655343Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1439 RBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1439 RBL 9 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655342Stiffener · bentINSPECTION TYPE:C BULK CARGO STA 1439 LBL 22 FLOOR WEB FWD SIDE ATTACH STIFFENER BENT. BULK CARGO STA 1439 LBL 22 FLOOR WEB FWD SIDE ATTACH STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655944Floor Panel · damaged1 HOLE 5TH FLOOR PANEL FROM LT SIDE POS 4L ZONE 2. FLOOR PANEL REPLACED AND INSTALLED AS PER EO B767-5320-9693-E.SDR IPXA09655943Floor Panel · damaged1 HOLE 5TH FLOOR PANEL FROM LT SIDE POS 5R ZONE 2. FLOOR PANEL REPLACED AND INSTALLED AS PER EO B767-5320-9693-E.SDR IPXA09655942Floor Panel · damaged1 HOLE 5TH FLOOR PANEL FROM LT SIDE POS 6R. FLOOR PANEL REPLACED AND INSTALLED AS PER EO B767-5320-9693-E.SDR IPXA09655941Floor Panel · dentedPOS 8R FLOOR PANEL HAS 6 DENTS. FLOOR PANEL REPLACED AND INSTALLED AS PER EO B767-5320-9693-E.SDR IPXA09655940Floor Panel · damaged1 HOLE 1ST PANEL FROM LT SIDE POS 2L ZONE 1. FLOOR PANEL REPLACED AND INSTALLED AS PER EO B747-5320-9693-E.SDR IPXA09655482Stiffener · crackedINSPECTION TYPE:C CTR TANK FRONT SPAR STIFFENER UPPER END AT LBL 10 FOUND CRACK (CRACK 2.125 INCH LENGTH). FWD CARGO COMPT WING CTR TANK FRONT STIFFENER AT LBL 10 WL 178.96, APPROX REPAIRED AS PER HX RS R57-11-36294 REV A. THIS REPAIR CLASSIFIED AS A MAJOR RSDR IPXA09655463Floor Support · crackedINSPECTION TYPE:C MAIN DECK FLOOR SUPPORT ATT ANGLE FOUND CRACKED JUST AT STA 1575 RBL 75-76 (CRACK 1.5 INCH LENGTH). MAIN DECK FLOOR SUPPORT ATT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655462Hinge Fitting · crackedINSPECTION TYPE:C LT WING I/B MAIN FLAP I/B AFT FLAP HINGE FTG FLANGE FOUND CRACKED (CRACK I/B FLANGE 1.125 INCH AND O/B FLANGE 1 INCH). LT WING I/B MAIN FLAP I/B AFT FLAP HINGE FTG REPAIRED AS PER SRM 57-53-02-2R1 FIG 201 REV 43. THIS IS CLASSIFIED AS A MAJSDR IPXA09655461Fairing · delaminatedINSPECTION TYPE:C RT WING - O/B FLAP I/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-17 PARA 4A FIG 10 REV 43.SDR IPXA09655460Attach Angle · crackedINSPECTION TYPE:6C MAIN DECK FLOOR SUPPORT ATT ANGLE FOUND CRACKED JUST AT STA 1575 LBL 75-76. MAIN DECK FLOOR SUPPORT ATT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43 JUST AT STA 1575 LBL 75-76.SDR IPXA09655458Skin · misrepairedINSPECTION TYPE:6C SURVEY SEQUENCE 323-F1-03 BETWEEN BS 1197+110 TO BS 1197+130 AND STR 24R-26R AREA SKIN REPAIR IS NOT CORRELATED TO SRM. SKIN REPAIRED AS PER HX RS 53-60-36299 REV A. REPEAT INSP IS REQUIRED AS PER HX RS 53-60-36299 REV A. THIS REPAIR CLASSDR IPXA09655455Skin · dentedINSPECTION TYPE:6C FX - SURVEY SEQUENCE 323-F1-02 A PROTRUDING HEAD FASTENER AREA DENT AND 2 LOC. DENT CLOSE TO THE EXISTING FLUSH REPAIR FOUND. SURVEY SEQUENCE 323-F1-02 LOCATION A FASTENER REMOVED AND REPLACED AS PER HX RS R53-31-36297 REV A. EXTERNAL AND SDR IPXA09655454Antenna · mislocatedINSPECTION TYPE:N/A FX - THE UPPER GPS ANTENNA NOT INSTALLED AT THE CORRECT LOCATION. FUSELAGE THE UPPER GPS ANTENNA EXISTING CUTOUT REPAIRED AT BS 654+33 BL 0 AS PER RS R53-00-36295 REV A. REPEAT INSPECTION IS REQUIRED AS PER HX RS R53-00-36295 REV A SHEET SDR IPXA09655390Floor Panel · puncturedINSPECTION TYPE:C DMI D396284 - 1 HOLE FOUND AT 7TH FLOOR PANEL LT SIDE POS 9R ZONE 1 (PUNCTURE .75 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655389Floor Panel · puncturedINSPECTION TYPE:C DIM D396283 - 1 HOLE FOUND AT 8TH FLOOR PANEL FROM LT SIDE POS 8R ZONE 2 (PUNCTURE 1 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655388Floor Panel · puncturedINSPECTION TYPE:C DMI D396290 - 1 HOLE FOUND AT 8TH FLOOR PANEL FROM LT SIDE POS 12R ZONE 2 (PUNCTURE 1 INCH DIA.) FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655387Floor Panel · puncturedINSPECTION TYPE:C DMI D396287 - 1 HOLE FOUND AT 5TH FLOOR PANEL FROM LT SIDE POS 12R ZONE 1 (PUNCTURE .75 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655386Floor Panel · puncturedINSPECTION TYPE:C DMI D396285 - 1 HOLE FOUND AT 1ST FLOOR PANEL FROM LT SIDE POS 12L ZONE 1 (PUNCTURE 1 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655385Floor Panel · puncturedINSPECTION TYPE:C DMI D396292 - 1 HOLE AT 5TH FLOOR PANEL FROM LT SIDE POS 2R ZONE 2 (PUNCTURE 1 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655384Floor Panel · puncturedINSPECTION TYPE:C DMI D396280 - 1 HOLE FOUND AT 7TH FLOOR PANEL FROM LT SIDE POS 6R ZONE 2 (PUNCTURE .5 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655383Floor Panel · puncturedINSPECTION TYPE:C DMI D396282 - 1 HOLE FOUND AT 5TH FLOOR PANEL FROM LT SIDE POS 8R ZONE 2 (PUNCTURE .5 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655382Floor Panel · puncturedINSPECTION TYPE:C D396288 - 1 HOLE FOUND AT 5TH FLOOR PANEL FROM LT SIDE POS 12R ZONE 1 (PUNCTURE .5 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.SDR IPXA09655381Floor Panel · puncturedINSPECTION TYPE:C DMI D396295 - 3 HOLES FOUND AT 3RD FLOOR PANEL FROM LT SIDE POS 4L ZONE 2 (ALL PUNCTURE .5 INCH DIA). FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R REV 43 FIG 201.
Back to Boeing 767-34AF