Douglas DC-8-62
Service difficulty reports · 2,778
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA000820Seat Track · wornDURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C5-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED SEAT TRACK FROM 60-12809 AND INSTALLED IAW DCSDR RRXA002472Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 360 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOSDR RRXA002415Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTAL AT FS 500 - 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITHSDR RRXA002406Threshold · crackedDURING A MAINTENANCE VISIT FOUND CRACKED AND DRILLED OFF SCREWS ON THE L1 DOOR SILL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH APPROVEDSDR RRXA002380Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 480 - 500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITSDR RRXA002374Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 300 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002340Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 798, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-20D AND EO NR 00-0SDR RRXA002311Intercostal · tool damageDURING A MAINTENANCE VISIT FOUND DRILL MARKS BETWEEN STA 620 - 640 XCW 0 CENTER LINE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED CHANNEL IAW DC-8 SRM 51-1-24, 53-2-0 AND 51-SDR RRXA002290Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1220 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-047 WITH SDR RRXA002289Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM INTERCOSTALS AT FS 280 - 300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-0SDR RRXA002288Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1360 - 1380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002287Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1400 - 1420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 3-26-00.SDR RRXA002286Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 980 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-047 WITH ASDR RRXA002285Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE INTERCOSTALS AT FS 1100 - 1120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002284Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1120 - 1140, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002283Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1280 - 1300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVSDR RRXA002282Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1160-1180, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVEDSDR RRXA002281Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE INTERCOSTALS AT FS 1800 - 1200, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITH APPROVED 8110-SDR RRXA002224Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1160 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-21, 51-1-20SDR RRXA002479Frame · misdrilledDURING A MAINTENANCE VISIT FOUND A MISDRILLED HOLE IN THE FRAME RADIUS AT STA 920 AND L12R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D, 51-1-4 ASDR RRXA002381Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 420 - 440, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002379Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 440 - 460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002378Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 380 - 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002377Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 360 - 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002376Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 340 - 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002375Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 320 - 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITSDR RRXA002328Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL DRILLED HOLES IN FLOORBEAM AT FS 740, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21 AND EO NR 00-047 WITH APPROVED 8110-SDR RRXA002308Floor Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOORBEAM SUPPORT AT STA 520 XCW 6 INCHES LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC-8 SRM 51-1-21, 53-2-0 ANSDR RRXA002292Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 460 - 480, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ALLOWABLE LIMITS IAW EO NR 00-047 WITSDR RRXA002291Intercostal · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM INTERCOSTALS AT FS 400 - 420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. HOLES WITHIN ACCEPTABLE LIMITATIONS IAW EO NR 00-0SDR RRXA002266Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL DRILLED HOLES IN THE FLOORBEAM AT FS 760, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21, 51-1-4, 51-1-20D SDR RRXA002344Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 840, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES PER EO NR 00-047 WITH APPROVED 8110-3 DATED SDR RRXA002235Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1280 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4, 51-1-21 ASDR RRXA002226Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1200 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLERS IAW DC-8 SRM 51-1-21, 51-1-4,SDR RRXA002463Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 480 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-4, 51-1-2SDR RRXA002359Angle · crackedDURING A MAINTENANCE VISIT FOUND A 6 INCH CRACK TO THE LT WING I/B SLOT UPPER O/B CUTOUT ANGLE AT STA XFS 250.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED PART IAW DC-8 SRM 51-1-21.SDR RRXA002343Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOORBEAM AT FS 830, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4, 51-1-21 AND EO SDR RRXA002279Rib · crackedDURING A MAINTENANCE VISIT FOUND A 2.5 INCH CRACK TO THE UPPER RIB ON THE NR 2 STUB WING AT STA XFS 250.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 5SDR RRXA002252Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE WEB ON BOX AREA ON L2 DOOR AREA STA 1460 LT BETWEEN L21L AND L22L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-SDR RRXA002653Skin · dentedDURING A MAINTENANCE VISIT FOUND THE D PIT DOOR DENTED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-4, 52-2-0, 52-2-3 AND 51-1-21.SDR ARWA000401Engine · malfunctionedMIA - FLT 517 - NR 1 ENGINE OIL PRESSURE LIGHT ILLUMINATED AND OIL QUANTITY DROPPED TO .5 GALLON. A PRECAUTIONARY ENGINE SHUTDOWN WAS PERFORMED. OIL PRESSURE WAS DECREASING AND OIL TEMP WAS INCREASING. MAX TEMP WAS 125 CELSIUS AND LOWEST OIL PRESSURE WAS 37SDR RRXA002411Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MEMBRANE IN THE MAIN CABIN INTERIOR UPPER CUSP LINE AT STA 1080 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ISDR RRXA002369Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND CRACKS AT SCREW HOLES ON NR 2 STUB WING UPPER SURFACE AT STA XS 233 TO 220, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SDR RRXA002297Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TOP OF LONGERON AND A WEAR SPOT ON THE LIGHT HOLE IN THE FWD LWR CARGO BILGE AT STA 544 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDEDSDR RRXA002278Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING NR 2 STUB WING UPPER RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ANGLE IAW EO NR 00-047 WITH APPROVED 8110-3 DATESDR RRXA000928Seat Track · misdrilledDURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES TO THE SEAT TRACK C1-R4 IN THE UPPER CARGO COMPT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED SEAT TRACK FROM 60-12809 AND INSTALLESDR RRXA000899Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO BAY. SEAT TRACK C6-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. CLEANED & BLENDED AREA AND INSTALLED IAW DC-8 SRM 53-2-3SDR RRXA000830Seat Track · wornDURING A MAINTENANCE VISIT, FOUND A WORN SEAT TRACK C2-R3 IN THE UPPER CARGO COMPT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW SEAT TRACK FROM 60-12809 AND INSTALLED IAW DC-8 SRM 53-2SDR RRXA000827Seat Track · damagedDURING A MAINTENANCE VISIT, FOUND HOLES ELONGATED IN THE CABIN UPPER SEAT TRACK C4-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. DISCREPANT HOLES WITHIN ALLOWABLE LIMITS, INSTALLED SEAT TRACK IAW DSDR RRXA000824Seat Track · damagedDURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE UPPER CARGO COMPT SEAT TRACK C4-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. DISCREPANT HOLES WITHIN ALLOWABLE LIMITS, INSTALLED SEAT TRACK
Back to Douglas DC-8-62