SDR UPS01834752Circuit Board · dirtyINSPECTION TYPE:N/A, NR 4 ENGINE FIRE DETECTION, NO TEST. CLEANED AND RE-RACK CARD A-6, OP CK NORMAL, WAIT NO HELP. OPENED NR 4 THRUST COWLING AND CLEANED ELECTRICAL CANNON PLUG AT PYLON. GROUND CHECK PERFORMED AND FOUND OK.SDR UPS01835039Bulkhead · crackedINSPECTION TYPE:C1/3 LT AFT PRESSURE BULKHEAD STA 1766 APPROX L11L IS CRACKED. REPAIRED AREA IAW DAC DWG SRO 8530007.SDR UPS01834745Skin · crackedINSPECTION TYPE:PFLT, LEFT AFT SERVICE DOOR HAS CRACK IN UPPER AFT RADIUS. CUT OUT DAMAGED SECTION OF SKIN, FABRICATED AND DRILLED UP REPAIR DOUBLER PER SRM 53 2. DAMAGE REMOVED, OK TO INSTALL. INSTALLED DOUBLER IAW SRM 53 2 1 COMPLETED TEMP REPAIR PER SRM SDR DHL2001803001Wire · brokenF/O HEADSET JACK INOP ON TAXI OUT. REPAIRED BROKEN WIRE AT F/O CONSOLE. OPS OK PER M/M 23-40-0.SDR DHL2001803002Control Box · malfunctionedNOSE WHEEL STEERING UNRESPONSIVE DURING START OF TAKEOFF ROLL. REJECTED T/O. INSPECTED NOSE AND MAIN GEAR, NO DISCREPANCIES FOUND. OPERATED NOSE WHEEL STEERING, OPS CHECKS OK IAW 32-50-0. SUSPECT RUNWAY CONDITIONS. A/C OK FOR SERVICE.SDR UPS01834700Battery Pack · inoperativeINSPECTION TYPE:N/A, DURING BITE CHECK NO EMERGENCY EXIT LIGHTS ILLUMINATED. REMOVED AND REPLACED BATTERY AND RELAY UNIT.SDR DHL2001806559Rib · crackedC-CHECK - LT WING LE RIB UPPER PART CRACKED 1/2 INCH AT STA XFS 822. PERFORMED STOP DRILL AND FABRICATED DOUBLER IAW SRM 57-2-0 FIG 2. CLEANED, TREATED & PRIMED IAW SRM 51-1-8B PAGES 12, 13. INSTALLED DOUBLER IAW SRM 57-2-0 FIG 2. STATUS-CLOSED.SDR RRXA003799Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LT.WW BATHTUB FITTING AT STA. 960 AND L24L FWD SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DSDR UPS01834632Battery Pack · dischargedINSPECTION TYPE:N/A, EMERGENCY LIGHTS NOT ON IN ARMED. REMOVED AND REPLACED BATTERY PACK, OP''S CHECK NORMAL. P/N ON - OFF: 5708458-503, S/N ON: FTL243, S/N OFF: 7.SDR UPS01834703Longeron · corrodedINSPECTION TYPE:C1 FWD PIT STA 385 LONG 31L HAS CORROSION FWD OF SPLICE. REMOVED PRODUCTION SPLICE IAW DC8 SRM 51-1-24, CLEANED AREA IAW DC8 SRM 51-1-8, LOCATED DRILLED PRODUCTION SPLICE IAW DC8 SRM 51-3-2, INSTALLED PRODUCTION SPLICE IAW DC8 SRM 21-1-20D.SDR UPS01834702Fitting · corrodedINSPECTION TYPE:C1 FWD CARGO PIT STA 320 L 34R - 35R FITTING IS CORRODED. REMOVED Z-FITTING, FAB SPLICE AND DRILLED NEW FITTING IAW SRM 53-2-0, ALODINED AND PRIMED IAW SRM 51-1-8, INSTALLED IAW DC8 SRM 51-1-21D.SDR UPS01834620Battery Pack · dischargedINSPECTION TYPE:N/A, EMERGENCY LIGHT LEFT ON, BATTERY PACK DEAD. REMOVED AND REPLACED BATTERY PACK. TEST OK.SDR DHL2001805002Current Limiter · failedSPOILER PRESSURE 0, PREFORMED ALT PROCEDURE. REMOVED AND REPLACED SPOILER PUMP CURRENT LIMITERS. OPS CHK OK PER M/M 27-62-0.SDR DHL2001805003Limit Switch · failedSPOILER PRESS 0 PERFORMED ALT PROCEDURE. REMOVED AND REPLACED SPOILER PUMP CURRENT LIMITERS. OPS OK PER M/M 27-62-0.SDR UPS01834704Fitting · crackedINSPECTION TYPE:C1 STA 1265 LONGERON 35R LONGERON SPLICE CRACKED. REMOVED LONGERON SPLICE IAW DC8 SRM 51-1-20D, RECEIVED NEW SPLICE P/N 3759258 -2N S/N TAG 0049957, LOCATED AND DRILLED NEW SPLICE IAW DC8 SRM 51-1 -24, INSTALLED IAW DC8 SRM 51-1-20D.SDR RRXA003592Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT WING #1 GROUND SPOILER O/B MOUNT FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-SDR RRXA003591Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO THE R/H WING BOTTOM T/E PANEL AT STA XRS 340 TO XRS 419, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLESDR RRXA003595Track · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "D-PIT" DOOR AFT TRACK (3" CRACK), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21.SDR RRXA003594Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE UNDER RT LONGERON 24 SUPPORT FITTING AT STA 920 RT W/W Y-920 X-66, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATD REPAIR AND INSTALLED IAW EO 00-316 WITH SDR RRXA003593Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE #1 GND SPOILER I/B MOUNT FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51-1-20SDR RRXA010002Cooler · failedLEFT MANIFOLD AIR TEMP DID NOT EXCEED 170C N1 WERE AT 88 PERCENT, ENGINE ANTI-ICE ON, AIRFOIL DEICE ON, TAIL DEICE SYSTEM ON, THIS IS THE 3RD WRITTEN UP SEE PAGES 7686-24 AND 7686-23 MIN NEED IS 190C NOTE LEFT PACK ON 80 PERCENT. REMOVED AND REPLACED NR 1 ENSDR RRXA010001Transformer · failedELECTRICAL SMOKE IN THE COCKPIT APPEARS TO COME OUT OF THE F/E PANEL. REMOVED AND REPLACED TRANSFORMER PER DC-8 M/M 33-00 ON FIRST OFFICERS SIDE. ALSO DEFECTED AREA UPPER F/E''S DESK PANEL. FOUND ALL COMPONENTS AND WIRING SECURE, NO DEFECTS.SDR RRXA003596Fastener · missingDURING A MAINTENANCE VISIT FOUND MISSING FASTENER ON THE RT UPPER WING THRU ACCESS HOLE 505C & THROUGH MID SPAR ACCESS HOLE 560C INSIDE TANK I/B BETWEEN STA 252 & 255, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR UPS01834583Control Valve · bindingINSPECTION TYPE:N/A AILERON BINDING, DURING CONTROL CHECKS AILERON WOULD NOT RETURN TO NEUTRAL ON ITS OWN AFTER BEING DISPLACED TO THE RIGHT. RTB *S/D* REMOVED AND REPLACED RT AILERON POWER CYLINDER/CONTROL VALVE UP TO STEP B2 AGE 204 MM 27-11-06. OPS CK LSDR DHL2001805001Current Limiter · failedON TAXI OUT NOTED NO SPOILER PRESSURE. RAN ABNORMAL PROCEDURES STILL NO SPOILER PRESS. REPLACED ALL THREE CURRENT LIMITERS OPS CHECKS GOOD I.A.W. 27-00-00SDR RRXA003603Longeron · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP ON LONGERON JUST FWD OF 'C' PIT DOOR AT STA 1140 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED SDR RRXA003601Panel · delaminatedDURING A MAINTENANCE VISIT FOUND DELAMINATION DAMAGE TO THE R/H WING BOTTOM T/E PANEL AT STA XRS 5 TO XRS 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED ISDR RRXA003599Door · delaminatedDURING A MAINTENANC EVISIT FOUND DELAMINATION IN 2 PLACES ON THE LEFT MLG TOP DOOR TO WING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0SDR RRXA003598Angle · crackedDURING A MAINTENANCE VISIT FOUND THE BULKHEAD ATTACH ANGLE BROKEN AND CRACKED ON THE AFT LWR CARGO COMPT AT STA 1320 X35 Z-8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED RESDR RRXA003597Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT LWR CORNER OF THE "D" PIT DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 52-2-0 FIG.SDR UPS01834701Fitting · corrodedINSPECTION TYPE:C1 BEAM FITTING ABOVE RT AFT O/W EXIT L14R HAS EXFOLIATION RUNNING ALONG FASTENER HOLES. REMOVED AND REPLACED FITTING IAW DC8 SRM 51-1-20D 51-1-21 AND 51-3-0.SDR DHL2001801518Structure · crackedRT WING L/E INNER PART CRACKED 2 INCHES AT HOT AIR LINER XFS 716.000. STOP DRILLED CRACK PER SRM 57-2-0 FIG 2. FABRICATED DOUBLER PER SRM 57-2-0 FIG 62. INSTALLED DOUBLER PER SRM 572-0 FIG 2.SDR UPS01834623Frame · corrodedINSPECTION TYPE:C1 AFT PIT STA 1060 FRAME CAP CORRODED ABOVE LONG 36. REMOVED CORROSION IAW DC8 SRM 51-1-8, AREA OUT OF LIMITS IAW DC8 SRM 53-2-0. DRILLED, REAMED NEW HOLES IAW DC8 SRM 51-3-2, INSTALLED NEW FRAME CAP IAW DC8 SRM 51-1-20D.SDR UPS01834622Shear Tie · corrodedINSPECTION TYPE:C1 AFT PIT STA 1040 SHEAR CLIP FWD SIDE BETWEEN L36 & L35L IS EXFOLIATED. REMOVED CORRODED SECTION OF SHEAR TIE, FABED NEW SECTION OF SHEAR TIE ALODINED AND PRIMED INSTALLED NEW SECTION OF SHEAR TIE IAW DC8 SRM 53-2-0 & 51-1-8.SDR DHL2001805089Pin · missingCAPTAINS LAP BELT RT SIDE DISCONECTED. INSTALLED MISSING COTTER PIN AND RESECURED RT LAP BELT ON CAPTS SEAT. OPS GOOD PER M/M 25-11-1SDR RRXA003608Web · chafedDURING A MAINTENANCE VISIT FOUND A CHAFFED WEB IN COCKPIT BETWEEN FRAMES -52 & -67, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 & 51-1-21.SDR RRXA003607Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE COCKPIT FLOOR PANEL CAPT'S SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-2SDR RRXA003605Pressure Panel · corrodedDURING A MAINTENANCE VISIT FOUND 21 SHEAR RIVETS ON THE FINGER DOUBLER AT THE COCKPIT AREA FLOOR BELOW AFT END OF CAPT'S CHAIR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-SDR RRXA003604Floor Panel · brokenDURING A MAINTENANCE VISIT FOUND ELONGATED SCREW HOLES BROKEN OUT ON THE FLOOR PANEL 681, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4SDR RRXA003606Skin · puncturedDURING A MAINTENANCE VISIT FOUND A PUNCTURE HOLE IN THE OUTER SKIN ON THE FUSELAGE AT STA 220 TO 240 AND L25L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-20D & SDR UPS01834631Floor Support · corrodedINSPECTION TYPE:C1 MAIN CABIN STA 1750 BEAM SUPPORT CORRODED. REMOVED AND REPLACED FLOOR SUPPORT IAW DC8 SRM 51-1-20D.SDR UPS01834612Fitting · crackedINSPECTION TYPE:C1, MAIN CABIN FITTING CRACKED L19RT AT FS 857. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D.SDR UPS01834609Fitting · crackedINSPECTION TYPE:C1, FITTING CRACKED AT FS 834 APPROX 70 INCHES BELOW LT CUSP. REMOVED AND REPLACED FITTING AT FS 834 10 INCHES BELOW CUSP LINE IAW DC8 SRM 51-1-20D.SDR DHL2001806004Tire · unserviceableON INITIAL T/O ROLL NOSE GEAR PULLED HARD RIGHT AND HARD LEFT WITH GRINDING NOISE. A/C BEHIND SAW SMOKE AND TIRE APPEARED SKEWD TO LEFT. INSPECTED NOSE GEAR FOUND NOSE TIRES MISMATCHED TREADS. LEFT TIRE HARD TO ROTATE. R&R LEFT AND RT NOSE TIRES PER M/M 32-4SDR UPS00834572Control Unit · malfunctionedINSPECTION TYPE:N/A ATB - ANTI-SKID INOP LIGHT ON APPROACH. R&R'D BAD ANTI-SKID CONTROL BOX. .SDR UPS01834736Longeron · corrodedINSPECTION TYPE:C1 MAIN CABIN LT STA 1250 LONG 10L IS CORRODED. REMOVED AND REPLACED LONGERON SECTION IAW DC8 SRM 53-2-2.SDR UPS01834642Longeron · corrodedINSPECTION TYPE:C1 MAIN CABIN LT STA 1250 LONG 10L IS CORRODED. REMOVED AND REPLACED LONGERON SECTION IAW DC8 SRM 53-2-2.SDR UPS01834641Longeron · corrodedINSPECTION TYPE:C1 MAIN CABIN STA 1100 LONG 9L IS CORRODED. REMOVED AND REPLACED LONGERON SECTION IAW DC8 SRM 53-2-2.SDR UPS01834629Web · damagedINSPECTION TYPE:C1, MAIN CABIN RT CUSP WEB HAS 2 PUNCTURES AND A CRACK BETWEEN FS 520 & FS 540. REMOVED DAMAGED AREA IAW DC8 SRM 53-2-0, FABBED REPAIR PARTS AND INSTALLED IAW DC8-5330-2159.SDR UPS01834624Fitting · corrodedINSPECTION TYPE:C1, FS 1160 L34L-L35L Z-FITTING IS CORRODED. REMOVED CORRODED FITTING, RECD NEW ONE ACQUIRED MAT ID FOR REPAIR ANGLES AND FABED ALODINED AND PRIMED ALL BARE AREAS AND INSTALLED FITTING AND REPAIR (REF) DC8 SRM 53-2-0, 51-1-8, 51-1-20D.
Back to Douglas DC-8-73F