Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL2001803140Tab · out of rigNO NOSE DOWN PITCH AT 80 KNOT ELEVATOR CHECK. FOUND ELEVATOR TABS OUT OF RIG. ADJUSTED ELEVATOR CONTROL TABS PER M/M 27-30-0. PRFORMED ACCEPTANCE FLT.SDR UPS00834571Bottle · dischargedINSPECTION TYPE:PFLT CREW PREFLT - EMERGENCY ESCAPE SLIDE PRESSURE LOW. SERVICED ESCAPE BOTTLE PER DC-8 MM 25-68-04SDR UPS01834737Fitting · crackedINSPECTION TYPE:C1 FWD CARGO PIT AT FS 510 - 520 LONG 33R IS CRACKED AT UPPER I/B FLANGE. REMOVED LONGERON 33R FS 395 TO FS 650 IAW DC8 SRM 51-1-20, LOCATED AND DRILLED NEW LONGERON IAW DC8 SRM 51-1-24, INSTALLED NEW LONGERON 33R AND TORQUE BOX CLOSEOUT IAW DSDR UPS01834734Longeron · crackedINSPECTION TYPE:C1 FWD CARGO COMPT STA 550 LONG 34R CRACKED. REPAIRED LONGERON PER DC8 SRM 53-2-2 AND SHEAR TIES PER DC8 SRM 53-2-0.SDR UPS01834733Longeron · crackedINSPECTION TYPE:C1, FWD CARGO COMPT LONGERON 34R CRACKED AT FS 550. REMOVED LONG SECTION 34R FROM STA 345 TO 630 IAW DC8 SRM 51-1-21, REMOVED SHEAR TIE SECTION FROM STA 460 - 480 TO FOM IAW DC8 SRM 51-1-20, 51-2-0, FABED SHEAR TIE, REPAIRS INSTALLED, LONGERONSDR UPS01834614Fitting · crackedINSPECTION TYPE:C1, T-FITTING BENEATH KEEL BEAM IN LT WHEEL WELL IS CRACKED FS 920. LOCATED AND DRILLED NEW FITTING IAW DC8 SRM 51-1-24, INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, INSTALLED CENTER SKIN IAW DC8 SRM 51-3-0.SDR UPS01834608Skin · corrodedINSPECTION TYPE:C1, FWD PIT STA 363 BETWEEN LONG 35L AND 35R SKIN HAS CORROSION AND BARE METAL. REMOVED CORROSION AT FWD PIT STA 363 BETWEEN L35L AND 35R IAW DC8 SRM 51-1-8, ALODINED 7 PRIMED IAW DC8 SRM 51-1-8.SDR UPS00834568Battery Pack · inoperativeINSPECTION TYPE:N/A EMERGENCY LIGHTS DO NOT TEST. R&R'D EMERGENCY LIGHT BATTERY PACK W/ REF TO M/M 33-50-01 LIGHTS OPE RATE NORMALLY.SDR DHL200180240CFitting · damagedRT HORIZONTAL STAB. FITTING LOWER PART CRACKED 1/2 INCH AT STA XFS60.REMOVED CRACKED FITTING PER SRM 51-1-20D,CLEANED ,TREATED AND PRIMED AREA AS REQUIRED PER SRM 51-1-8B.INSTALLED NEW FITTING PER SRM 51-1-20D.SDR UPS01834640Longeron · corrodedINSPECTION TYPE:C1 FWD CARGO PIT AT FS 220 - 240 LONGERON 35R IS CORRODED. REPAIRED LONGERON PER DC8 SRM 53-2-2 FIG 10.SDR UPS01834630Frame · damagedINSPECTION TYPE:C1, FWD CARGO PIT AT FS 120 AT LONG 39R 30R FRAME HAS BROKEN OUT PIECE OF METAL AND IS CRACKED. REPAIRED FRAME IAW EO DC8-5310-11728A.SDR UPS01834626Fitting · crackedINSPECTION TYPE:C1, FWD PIT TORQUE BOX STA 320 L27L HAS CRACKED Z-FITTING. REMOVED FITTING, FABBED DOUBLER IAW 53-2-0, ALODINED AND PRIMED IAW SRM 51- 1-8, INSTALLED IAW 51-1-21.SDR UPS01834625Fitting · crackedINSPECTION TYPE:C1, FWD PIT STA 350 FITTING BETWEEN LONG 35L & 36L IS CRACKED. REMOVED Z-FITTING, FABBED SPLICES IAW SRM 53-2-0, ALODINED AND PRIMED IAW SRM 51-1-8, INSTALLED IAW 51-1-21.SDR UPS01834613Skin · corrodedINSPECTION TYPE:C1, FWD PIT STA 390 BETWEEN LONG 32R & 33R SKIN IS CORRODED. REMOVED CORROSION IAW DC8 SRM 51-1-8 MAT ID FOR EXTERNAL DOUBLER 7075-T6 .03 2 IAW DC8 SRM 53-4-1. FABD DOUBLER IAW DC8 SRM 53-2-1, ALODINED AND PRIMED DOUBLER AND INSTALLED IAW DC8SDR UPS01834611Web · crackedINSPECTION TYPE:C1 C2 DOOR JAMB WEB HAS CRACK EMINATING FROM NUT PLATE HOLE STA 545. REMOVED DAMAGED AREA IAW DC8 SRM 53, FABD REPAIR ANGLE IAW DC8 SRM 53-2-0, HEAT TREAT 2024-0 TO 2024-T4, ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED REPAIR DOUBLER IAW SDR RRXA003800Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION/SHEARED RIVITS DAMAGE TO DOUBLER AT STA. 1697 AND L29L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW EO#0SDR RRXA001097Cooler · failedTOP OF CLIMB, LT MANIFOLD TEMP INCREASED UNTIL NR 2 MAN AIR TEMP LIGHT CAME ON TEMP AT 265, NR 2 HIGH STAGE LIGHT ON. TURNED NR 2 BLEED OFF, MANIFOLD TEMP MOMENTARILY DECREASED THEN NR 1 MAN AIR TEMP LIGHT CAME ON. CYCLED TO MAINTAIN CABIN. BOTH NR 1 & 2 BSDR UPS01834610Fitting · crackedINSPECTION TYPE:C1, MAIN CABIN FITTING CRACKED INSIDE OF INTERCOSTAL L19 RT AT FS 834. REMOVED CRACKED FITTING, DRILLED NEW FITTING (P/N 37799782) TO FIT IAW DC8 SRM 51-1-24, INSTALLED FITTING WITH HI-LOKS IAW DC8 SRM 51-1-20D.SDR RRXA003612Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MOST O/B HOLE ON THE R/H WING LWR SKIN AT STR 64, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SDR RRXA003611Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BATHRUB FITTING BETWEEN STA 1690 & 1700 AND L34L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM SDR RRXA003610Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR STRUT FITTING AFT LWR CARGO COMPT AT STA 1160 AND L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED ISDR RRXA003609Flange · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR BEAM R/H O/B LWR LEG ON FWD SIDE AT STA 920, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW EO#0SDR UPS00834554Skin · crackedINSPECTION TYPE:N/A NR 1 CARGO DOOR SKIN HAS A 3/4 INCH CRACK. CRACK OUT OF LIMITS. EDGE DISTANCE 2.D WITHIN SRM 52-2-0 LIMITSSDR RRXA003502Intercostal · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL W/W AT STA 940 AND WING STA 69.5 RT W/W, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR DHL2000801157Pump · unserviceableUPON EXECUTING HORIZONTAL STABILIZER BEFORE TAXI FLOW, CAPT FOUND NR 2 HYDRAULIC PUMP INOP. R&R ENGINE DRIVEN HYD PUMP & CASE DRAIN FILTER. OPS CHECKED OK PER M/M 29-10-15.SDR DHL200080228CFairing · delaminatedAT C CK; LT WING TO FUSELAGE LWR FAIRING 741 DELAMINATED STA 650 XCW 30. REMOVED FAIRING IAW SRM 51-3-0 PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW FAIRING IAW SRM 51-3-0 PG 1. REF: N/R 0627.SDR RRXA003506Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION BLISTERS ON THE SKIN AT STA 1714 AND L29L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003505Structure · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE REPAIR PATCH RIVETS ON COCKPIT SUB-FLOOR FWD OF L/H AVIONICS RACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003504Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE ANGLE SUPPORT FITTING AT STA 960 R/H, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003503Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON WEB ABOVE RT LONGERON 24Y AT STA 879 X=-59 Z=10 INCH, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR UPS00834564Display · malfunctionedINSPECTION TYPE:N/A WHILE BEING VECTORED FOR AN APPROACH INTO SDF, SMOKE & FUMES WERE EX PERIENCED IN THE COCKPIT. BOTH EFIS SCREENS ON THE CAPT'S SIDE WENT BLANK & SOME KIND OF POWER SURGE WAS HEARD. SHORTLY THEREAFTER THE CAPTS EFIS SCREENS RETURNED TO OPESDR DHL200080235CFloor Support · crackedAT C CHECK; MAIN CARGO COMPARTMENT FLOOR LWR SIDE ATTACH ANGLE CRACKED 1/2 INCH BETWEEN STA 1746 TO STA 1766 BLO. REMOVED DAMAGED ANGLE IAW SRM 53-2-0, FIG 1B, CLEANED,TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED ANGLE IAW SRM 53-SDR RRXA003507Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE "D-PIT" DOOR BOTTOM AFT CORNER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR DHL200080229CFloor Panel · crackedAT C CHECK; NR 9 TRANSFERENCE FLOOR LWR SKIN CRACKED AND UPPER SKIN BROKEN. PERFROMED STOP DRILL IAW SRM 53-2-3, FIG 5, CLEANED,TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLERS IAW SRM 53-2-3 FIG 5. REF: N/R 0854.SDR RRXA003513Sill · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE REPAIR AFT SIDE OF "C-PIT" DOOR SILL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003512Frame · brokenDURING A MAINTENANCE VISIT FOUND THE AFT SIDE FWD FRAME BROKEN OFF "C-PIT" DOOR SILL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003511Sill · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "C-PIT" DOOR SILL REPAIR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003510Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN WEB AT RT. CUSP AT STA 1300 Y=1300 X-66 Z-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003509Floor Panel · damagedDURING A MAINTENANCE VISIT FOUND TORN OUT SCREW HOLES ON THE COCKPIT FLOOR PANEL BETWEEN PILOT & CO-PILOTS SEAT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003508Web · tornDURING A MAINTENANCE VISIT FOUND A TORN STRUCTURE ON 'A' PIT DOOR INTERNAL WEB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR DHL2000805088Spring · unserviceableNR 2 START WILL NOT STAY IN DETENTS. FOUND NR 2 START LEVER DETENT SPRING BROKEN. R&R START LEVER SPRING, OPS CHECK OK PER M/M 76-12-1.SDR RRXA003518Track · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "C-PIT" DOOR DOOR COVER AT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003517Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND TORN OUT SCREW HOLES ON THE COCKPIT FLOOR PANEL PILOTS SEAT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003516Floor Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR PANEL 678, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003515Skin · crackedDURING A MAINTENANCE VISIT FOUND 2 CRACKS ALONG BOTTOM OF MAIN CARGO DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003514Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT LONGERON 24 SUPPORT FITTING FWD EDGE AT STA 902, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003806Door Frame · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT DOOR FRAME AT STA. 300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 & 51-1-21.SDR DHL200080218CSkin · crackedAT C CHECK; AFT FUSELAGE NR 62 ACCESS PANEL FRAME LOWER PART 3 EA CRACKS (1/2 INCH) REMOVED AFFECTED AREA IAW SRM 53-2-0 FIG 1B, CLEANED,TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED PLATE IAW SRM 53-2-0, FIG 1B. REF: N/R 1877.SDR RRXA003522Threshold · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND DENTED EDGES TO THE "D-PIT" THRESHOLD/KICK PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////OPEN/////SDR RRXA003521Doubler · crackedDURING A MAINTENANCE VISIT FOUND 'C-PIT' DOOR HAS REPAIR CRACKING OFF, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
Back to Douglas DC-8-73F