SDR DHL200080510CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT TRACK NR 3 LUG WORN FROM STA 1380.000 TO 1400.000. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080528CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED .5 INCH AT XF 141.000. PERFORMED STOP DRILL IAW SRM 55-2-0, FIG 2, CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0, FIG 2.SDR DHL200080527CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/R INNER RIB CRACKED .5 INCH AT XE 116.000. PERFORMED STOP DRILL IAW SRM 55-2-0, FIG 2, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0, FIG 2.SDR RRXA002831Skin · corrodedDURING A MAINTENANCE VISIT FOUND PITTING ON THE UPPER SURFACE ON THE RT O/B FLAP O/B AT STA 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR DHL200080559CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED .5 INCH AT XE 141.000. PERFORMED STOP DRILL IAW SRM 55-2-0, FIG 2. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0, FIG 2.SDR DHL200080558CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED 2 INCHES AT XF 54.000. PERFORMED STOP DRILL IAW SRM 55-2-0, FIG 2. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0, FIG 2.SDR DHL200080552CFloor Support · crackedAT C-CHECK, MAIN CARGO FLOOR SUPPORT ANGLE CRACKED 2 INCHES AT STA 1700.00 LBL 4D. REMOVED FLOOR SUPPORT ANGLE IAW SRM 51-1-21 PG 1. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED NEW SUPPORT ANGLE IAW SRM 51-1-21 PG 1.SDR RRXA002980Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE SIDE BRACE MOUNT BOSS ON THE LT WING LWR REAR SPAR FLAP FITTING AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED, PRIMED AND PAINTED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPASDR RRXA002979Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORRISION DAMAGE ON THE SIDE BRACE MOUNTING BOSS ON THE RT WING LWR REAR SPAR FLAP FITTING AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR ANDSDR DHL200080509CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT-TRACK NR 3 LUGS WORN STA 952.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3 PG 49-50.SDR DHL200080532CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED 1 INCH AT XF 47.500 LOWER PART. PERFORMED STOP DRILL IAW SRM 55-2-0, FIG 2. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0 FIG 2.SDR DHL200080531CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED 1 INCH AT XF 87.500. PERFORMED STOP DRILL IAW SRM 55-2-0, FIG 2. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0 FIG 2.SDR DHL200080530CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED AT XF 60.000. PERFORMED STOP DRILL IAW SRM 55-2-0 FIG 2. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0, FIG 2.SDR DHL200080529CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED 2 INCHES AT XF 54.000. PERFORMED STOP DRILL IAW SRM 55-2-0 FIG 2. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0, FIG 2.SDR DHL200080526CRib · crackedAT C-CHECK, RT HORIZONTAL STABILIZER L/E INNER RIB CRACKED 2 INCHES AT XF 60.000. PERFORMED STOP DRILL IAW SRM 55-2-0, FIG 2. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2. FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0 FIG 2.SDR DHL200080525CRib · crackedAT C-CHECK, RT HORIZONTAL STABLIZER L/E INNER RIB CRACKED 2 INCHES AT XE 54.000. PERFORMED STOP DRILL IAW SRM 55-2-0, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2, FABRICATED AND INSTALLED DOUBLER IAW SRM 55-2-0, PG 2.SDR RRXA003069Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LONGERON RT SIDE AT STA 1690-1763 AND L28R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 AND 51-1-21.SDR RRXA003062Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT IN THE MAIN CABIN AT STA Y=580 AND X=-34, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SDR RRXA003061Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT IN THE MAIN CABIN AT STA Y=580 AND X-38, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SSDR RRXA003698Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SURFACE OF LONGERON 28R AT STA 1692 - 1763, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 53-2-0 AND 51-1-21. (SDR RRXA003697Floor Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT AT STA Y=580 X=-34, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-4 AND MM 20-16-SDR RRXA003696Floor Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT AT STA 580, X-38, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-4 AND MM 20-16-00SDR RRXA003688Floor Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT AT STA 580, X-38, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4 AND MM 20-16-SDR RRXA003685Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON 28 RT SIDE AT STA 1690 TO 1763, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND 53-2-0. (CORROSDR RRXA003684Floor Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT AT STA Y=580 X=-34, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4 AND MM 20-1SDR DHL200080555CAttach Fitting · brokenAT C-CHECK, FWD CARGO DOOR SHROUD FWD ATTACH BRACE RETAINER BROKEN. REMOVED RETAINER FROM DOOR IAW SRM 51-1-21 PG 1, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B PG 1-2, FABRICATED AND INSTALLED NEW RETAINER IAW SRM 51-1-21 PG 1.SDR DHL200080554CCargo Track · deterioratedAT C-CHECK, MAIN CARGO- NR 3 TRACK SHOWS FLOOR SUPPORT HOLES DETERIORATED FROM STA 250.000 TO STA 130.000. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, SDR DHL200080514CCargo Track · brokenAT C-CHECK, MAIN CARGO COMPARTMENT- TRACK NR 6 LUG BROKEN FROM STA 1580.000 TO 1600.000. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080513CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT NR 2 TRACK LUGS WORN FROM STA 230.000 TO STA 62.000. CUT OUT DAMAGED AREA IAW SRM 53-2-3 PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080508CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT-TRACK NR 4 LUGS WORN STA 1135.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080518CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT-TRACK NR 4 LUGS WORN STA 1135.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080516CCargo Track · brokenAT C-CHECK, MAIN CARGO COMPARTMENT-TRACK NR 6 LUG BROKEN FROM STA 1580.000 TO 1600.000. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080515CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT NR 2 TRACK LUGS WORN FROM STA 230.000 TO STA 62.000. CUT OUT DAMAGED AREA IAW SRM 53-2-3 PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR RRXA002974Rib · crackedDURING A MAINTENANCE VISIT FOUND A SMALL DOUBLER CRACKED ON THE RIGHT O/B, I/B FLAP SCISSOR AREA LWR SURFACE AFT CORNER OF RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED RESDR UPS00833652Floorbeam · corrodedINSPECTION TYPE:N/A, CORRODED FLOORBEAMS STA 1420, 1440, 1460. *S/D* REPAIRED FLOORBEAM CORROSION AT STA 1420 AND 1440 AS PER EO DC8-5310-13142A.SDR UPS00833476Angle · crackedINSPECTION TYPE:N/A, 3 INCH CRACK IN NR 2 PYLON SKATE ANGLE. *S/D* REMOVED CRACKED SKATE ANGLE. LOCATED AND DRILLED AND INSTALLED NEW SKATE ANGLE IAW DWG AND DC8 SRM 51-1-24.SDR DHL200080507CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT TRACK NR 7 LUGS WORN AT STA 180.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3 PG 49-50. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3 PG 49-50.SDR DHL200080517CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT TRACK NR 7 LUGS WORN AT STA 180.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080580CSkin · deformedRIGHT WING O/B AILERON LOWER SKIN COVERS DEFORMED AT XW 420.000. REMOVED DEFORMED COVER PER SRM 57-2-0. FABRICATED COVER PER SRM 57-2-1. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED NEW COVER PER SRM 57-2-1.SDR DHL200080579CFrame · crackedTAIL CONE INTERIOR FRAME CRACKED 1 INCH APPROX BETWEEN STA FS 1818 - 1828. STOP DRILLED PER SRM 53-2-0 FIG 18. FABRICATED DOUBLER PER SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 53-2-0 FIG 1B.SDR DHL200080573CRib · crackedRIGHT WING L/E INTERNAL PART RIB CRACKED 1 INCH AT XFS 743.000 (518 ACCESS PANEL). STOP DRILLED PER SRM 57-2-5. FABRICATED DOUBLER PER SRM 57-2-5. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 57-2-5.SDR DHL200080557CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT-TRACK NR 5 LUG WORN STA 1700.000. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR DHL200080553CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT-TRACK NR 7 LUGS WORN STA 800.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR RRXA002981Skin · gougedDURING A MAINTENANCE VISIT FOUND WORN/GOUGED RIGHT O/B LEADING EDGE BETWEEN STA 340 - 410, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-1, 51-1-4 AND 51-1-20.SDR RRXA002977Skin · bentDURING A MAINTENANCE VISIT FOUND THE EXHAUST GATE BENT ON THE RIGHT O/B FLAP O/B LWR CORNER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-1 AND 51-1-2SDR DHL200080511CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT TRACK NR 7 LUGS WORN AT STA 250.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3 PG 49-50. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3 PG 49-50.SDR DHL200080533CSkin · wornAT C-CHECK, LT WING UPPER SKIN TRIPLER WORN 3 INCHES BETWEEN CENTER AND REAR SPAR XW 5.000 AND XW 17.000. PERFORM NDT INSPECTION TO VERIFY POSSIBLE CRACK. PERFORMED HEFC METHOD INSPECTION IAW DPS 4.751, ITEM 4.7 FIG 51. WEAR FOUND WITHIN LIMITS, IAW SRM 57-1SDR DHL200080523CPlate · brokenAT C-CHECK, LT ELEVATOR T/E UPPER PLATE BROKEN .5 INCH AT XC 272.000. REMOVED BROKEN PLATE IAW SRM 51-1-21, PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW PLATE IAW SRM 51-1-21, PG 1.SDR DHL200080519CCargo Track · wornAT C-CHECK, MAIN CARGO COMPARTMENT TRACK NR 7 LUGS WORN AT STA 250.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR RRXA003063Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE FWD END OF THE FLOOR PANEL JOINT SUPPORT IN THE MAIN CABIN AT STA Y=580 AND X-36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED R
Back to Douglas DC-8-73F