SDR RRXA003695Floor Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT AT STA 580 X-36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW MM 20-16-0 AND DC-8 SRM 51-1-4. SDR RRXA003687Floor Support · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL JOINT SUPPORT FWD END AT STA Y=580 X-36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4 AND SDR DHL200080582CBracket · crackedNR 13 DOOR RT AFT BRACKET CRACKED. REMOVED AND REPLACED AFT BRACKET PER OHM 52-1-11 PG 1 - 5. OPS CHKD PER M/M 52-45-1 PG 202 - 204.SDR DHL200080581CFitting · crackedNR 12 DOOR LT FWD FITTING CRACKED. REMOVED AND REPLACED NR 12 DOOR LT, FWD FITTING AS REQUIRED PER OHM 52-1-11 PG 1, 2, 4, 5. OPS CHK FOUND OK PER M/M 52-45-1.SDR DHL200080572CWeb · crackedMAIN CARGO LT CUSP ADJACENT SUBFLOOR CRACKED 2 INCHES FROM STA 1540.000 TO 1560.000. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 53-2-0.SDR DHL200080567CCargo Track · wornMAIN CARGO NR 3 TRACK LUG WORN AT STA 430.000. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED SPLICE PER SRM 53-2-3. FABRICATED NEW TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED NEW TRACK AND SPLICE PER SRM 53-2-3.SDR DHL200080563CCargo Track · wornMAIN CARGO NR 3 TRACK LUG WORN AT STA 430.000. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED SPLICE PER SRM 53-2-3. FABRICATED NEW TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED SPLICE AND TRACK PER SRM 53-2-3.SDR DHL200080562CRib · crackedRT HORIZ STABILIZER L/E INNER RIB CRACKED 2 INCHES AT XE 54.000. STOP DRILLED PER SRM 55-2-0. FABRICATED DOUBLER PER SRM 55-2-0. CLEANED, TREATED AND PRIMED PER SRM 55-2-0.SDR DHL200080561CRib · crackedRT HORIZ STABILIZER L/E INNER RIB CRACKED 2 INCHES AT XF 60.000. STOP DRILLED CRACK PER SRM 55-2-0. FABRICATED DOUBLER PER SRM 55-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 55-2-0.SDR RRXA002976Skin · damagedDURING A MAINTENANCE VISIT FOUND A PIECE OF DOUBLER BROKEN OFF ON THE RIGHT O/B FLAP DOUBLER FOR ICE SCRAPER AT STA 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM SDR RRXA002975Skin · canningDURING A MAINTENANCE VISIT FOUND OIL PANNING ON THE RIGHT O/B FLAP I/B TRAILING EDGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-1.SDR RRXA002973Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE I/B AFT CORNER EXHAUST GATE ON THE RIGHT O/B FLAP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-1, 51SDR RRXA002835Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON SIDE BRACE MOUNT BOSS ON THE LT WING LWR REAR SPAR FLAP FITTING AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA002834Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LWR REAR SPAR FLAP FITTING ON SIDE BRACE MOUNTING BOSS ON THE RT WING AT STA 219, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA002833Skin · bentDURING A MAINTENANCE VISIT FOUND A BENT EXHAUST GATE ON THE O/B LWR CORNER OF THE RIGHT O/B FLAP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA002832Skin · damagedDURING A MAINTENANCE VISIT FOUND A PIECE OF DOUBLER BROKEN OFF ON THE RIGHT O/B FLAP DOUBLER FOR ICE SCRAPER AT STA 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR UPS00833496Fitting · crackedINSPECTION TYPE:C123, LEFT HORIZONTAL STAB L/E LOWER ATTACH FLANGE FITTING IS CRACKED AT XFS 60. REMOVED AND REPLACED FITTING IAW DWG 3701427 AND SRM 51-1-20D, 51-1-21.SDR DHL200080574CCargo Track · wornMAIN CARGO COMPT TRACK NR 4 LUG WORN STA 1685.000 TO 1701.000. REMOVED AND REPLACED TRACK FROM STA 1685.000 TO 1701.000 PER SRM 51-3-0.SDR DHL200080571CFloor Support · crackedMAIN CARGO COMPT FLOOR SUPPORT ANGLE 3 INCH CRACK AT STA 1700.000 LBL 22 IN. STOP DRILLED PER SRM 53-2-0. FABRICATED ANGLE DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 53-2-0.SDR DHL200080569CCargo Track · corrodedMAIN CARGO COMPT NR 4 FLOOR TRACK FLANGE SHOWS CORROSION STA 1480.000. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED SPLICE PER SRM 53-2-3. FABRICATED TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED SPLICE AND TRACK PER SRM SDR DHL200080568CCargo Track · wornMAIN CARGO COMPT TRACK NR 5 LUGS WORN STA 330.00. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED SPLICE PER SRM 53-2-3. FABRICATED TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED SPLICE AND TRACK PER SRM 53-2-3.SDR DHL200080566CRib · crackedRT HORIZ STAB L/E INNER RIB CRACKED .5 INCH AT XF 116.000. STOP DRILLED CRACK PER SRM 55-2-0. FABRICATED DOUBLER PER SRM 55-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 55-2-0.SDR DHL200080565CRib · crackedRT HORIZONTAL STAB L/E INNER RIB CRACKED 2 INCH AT STA XF 60.000. STOP DRILLED PER SRM 55-2-0. FABRICATED DOUBLER PER SRM 55-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 55-2-0.SDR DHL200080564CCargo Track · wornMAIN CARGO COMPT TRACK NR 4 LUGS WORN AT STA 220.00. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED SPLICE PER SRM 53-2-3. FABRICATED NEW TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED SPLICE AND TRACK PER SRM 53-2-3.SDR DHL200080560CCargo Track · wornMAIN CARGO COMPT TRACK NR 4 LUGS WORN STA 220.00. CUT OUT DAMAGED AREA PER SRM 53-2-3 PAGE 49-50. FABRICATED SPLICE PER SRM 53-2-3. FABRICATED NEW TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED SPLICE AND TRACK PER SRM 53-2-3SDR DHL200080520CCargo Track · corrodedAT C-CHECK, MAIN CARGO COMPARTMENT FLOOR TRACK NR 4 SHOWS CORROSION BETWEEN STA 1010 AND STA 1050. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50SDR RRXA002830Skin · damagedDURING A MAINTENANCE VISIT NEED TO REMOVE TEMP. REPAIR AND INSTALL PERMANENT REPAIR AT STA 1220 STR 35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR UPS00833583Floorbeam · corrodedINSPECTION TYPE:C123, STA 1540 FLOORBEAM IS CORRODED BEYOND LIMITS AT LBL 50. REPAIRED IAW 8110-3 APPROVED DH SK 806-428.SDR UPS00833575Floorbeam · corrodedINSPECTION TYPE:C123, STA 1520 FLOORBEAM IS CORRODED BEYOND LIMITS AT LBL 50. REPAIRED FLOORBEAM IAW 8110-3 APPROVED DH SK 806-429.SDR UPS00833411Battery Pack · inoperativeINSPECTION TYPE:N/A, EMERGENCY EXIT LIGHT INOP. REPLACED BATTERY PACK.SDR DHL200080556CCargo Track · wornAT C-CK, MAIN CARGO COMPARTMENT TRACK NR 4 LUGS WORN STA 75.00. CUT OUT DAMAGED AREA IAW SRM 53-2-3, PG 49-50, CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, PG 1-2, INSTALLED NEW TRACK AND SPLICE IAW SRM 53-2-3, PG 49-50.SDR UPS00833604Fitting · corrodedINSPECTION TYPE:C123, VERTICAL STAB NR 3 RUDDER DAMPER ATTACH POINT FITTING IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED FITTING IAW DWG 3651256, AND SRM 51-3-0.SDR UPS00833539Floorbeam · corrodedINSPECTION TYPE:C123, MAIN CABIN FLOORBEAM AT STA 1560 LBL 50 IS CORRODED BEYOND LIMITS. REPAIRED FLOORBEAM IAW 8110-3 APPROVED DH SK 806-427.SDR UPS00833535Frame · crackedINSPECTION TYPE:C123, VERTICAL STAB L/E FORMER IS CRACKED AT ZFS 171 LEFT SIDE. REPAIRED FORMER IAW SRM 55-2-0 FIG 2.SDR UPS00833526Rib · crackedINSPECTION TYPE:C123, RIGHT WING L/E UPPER RIB IS CRACKED AT XFS 416.5. REPAIRED RIB IAW SRM 57-2-0 FIG 2.SDR UPS00833525Rib · crackedINSPECTION TYPE:C123, RIGHT WING L/E UPPER RIB IS CRACKED AT XFS 341.25. REPAIRED RIB IAW SRM 57-2-0 FIG 2.SDR UPS00833627Angle · crackedINSPECTION TYPE:C123, LEFT WING L/E UPPER RIB ANGLE IS CRACKED AT XS 467.323. REMOVED, FABRICATED, AND REPLACED RIB ANGLE/DOUBLER IAW DWG 5770170, AND SRM SRM 51-1-20D.SDR UPS00833582Finger Doubler · corrodedINSPECTION TYPE:C123, STA 200 LONG 31L FINGER DOUBLER IS CORRODED BEYOND LIMITS. REMOVED, FABRICATED, AND REPLACED DOUBLER IAW 8110-3 APPROVED DH SK 806-078, AND SRM 51-1-20D, 51-1-21.SDR UPS00833581Fitting · crackedINSPECTION TYPE:C123, RIGHT WING STA XW 727 STRINGER 3 ATTACH CLIP IS CRACKED. REMOVED, FABRICATED, AND REPLACED FITTING IAW DWG 4614390, AND 8110-3 APPROVED DH SK 806-014, AND SRM 51-1-20D.SDR UPS00833580Fitting · crackedINSPECTION TYPE:C123, STA 1200 LONG 27L DOOR STOP FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3755854, AND SRM 51-1-20D, 51-1-21.SDR UPS00833577Angle · crackedINSPECTION TYPE:C123, LEFT NR 2 STUB WING VERTICAL ANGLE IS CRACKED AT XS250. REMOVED, FABRICATED, AND REPLACED ANGLE IAW DWG 9753293, AND SRM 51-1-20D.SDR UPS00833572Doubler · crackedINSPECTION TYPE:C123, RIGHT WING L/E LOWER INTERNAL DOUBLER IS CRACKED AT XFS 597.5. REMOVED, FABRICATED, AND REPLACED DOUBLER IAW DWG 5769600, AND SRM 51-1-20D, 51-1-21.SDR UPS00833564Rib · crackedINSPECTION TYPE:C123, LEFT NR 1 STUBWING UPPER RIB IS CRACKED AT XS 520. REPAIRED RIB IAW SRM 57-2-0 FIG 2.SDR UPS00833562Fitting · crackedINSPECTION TYPE:C123, STA 1690 LONG 26L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4641324, AND SRM 51-1-21, AND 51-1-20D.SDR UPS00833559Angle · crackedINSPECTION TYPE:C123, RIGHT WING L/E VERTICAL ANGLE IS CRACKED AT XS 520. REMOVED, FABRICATED, AND REPLACED ANGLE IAW DWG 9753297, AND SRM 51-1-20D, 51-1-21.SDR UPS00833548Fitting · crackedINSPECTION TYPE:C123, LEFT WING AT XRS 90 HAS A CRACKED SPLICE FITTING AT STRINGER 16 TO FRONT SPAR. REMOVED, FABRICATED, AND REPLACED FITTING IAW DEG 3645275, AND SRM 51-1-20D.SDR UPS00833522Rib · crackedINSPECTION TYPE:C123, LEFT WING L/E RIB IS CRACKED AT XFS 622.5. REPAIRED RIB IAW SRM 57-2-0 FIG 2.SDR UPS00833521Rib · crackedINSPECTION TYPE:C123, LEFT HORIZONTAL STAB L/E LOWER RIB IS CRACKED AT XFS 150. REPAIRED RIB IAW SRM 55-2-0 FIG 2.SDR UPS00833520Rib · crackedINSPECTION TYPE:C123, LEFT WING L/E LOWER RIB IS CRACKED AT XOLDI 6.225. REPAIRED RIB IAW SRM 57-2-0 FIG 2.SDR UPS00833519Rib · crackedINSPECTION TYPE:C123, LEFT WING L/E UPPER RIBS ARE CRACKED AT XFS 647.5, AND XFS 635. REPAIRED RIBS IAW SRM 57-2-0 FIG 2.
Back to Douglas DC-8-73F