Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL200080467CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 100.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED AREA PER SRM 51-1-8. INSTALLED DOUBLER WITSDR DHL200080466CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 580.00 L-35 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED AREA PER SRM 51-1-8. INSTALLED DOUBLER WITSDR DHL200080465CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE SHOWS 2 CRACKS OF 1 INCH AT STA 400.00 L-34 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0, 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8.SDR DHL200080464CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE SHOWS 2 CRACKS OF 1 INCH AT STA 400.00 L-34 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0, 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8.SDR DHL200080463CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE SHOWS 2 CRACKS OF 1 AND .5 INCH AT STA 420.00 L-30 AND 2-29 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0, 53-2-0. CLEANED, TREATED AND PRIMEDSDR DHL200080462CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1.5 INCH AT STA 460.00 L-31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0, 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALSDR DHL200080461CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 480.00 L-31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0, 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLESDR DHL200080460CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 520 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0, 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ASDR DHL200080459CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 500.00 L-33 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE SDR DHL200080458CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED AT STA 500.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NESDR DHL200080457CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 480.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE SDR DHL200080456CAngle · crackedFWD BAGGAGE COMPT REINFORCING ANGLE CRACKED 1 INCH AT STA 300.00 L-31 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NSDR DHL200080455CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED AT 1 INCH AT STA 100.00 L31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLSDR DHL200080454CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED AT STA 100.00 L33 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED REINFORCING ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEWSDR DHL200080453CAngle · crackedFWD BAGGAGE COMPT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 120.00 L-31 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-0. FABRICATED ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE PER SRM 51-1-21.SDR DHL200080426CCargo Track · brokenMAIN CARGO NR 2 LT TRACK LUGS BROKEN AT STA 140. REMOVED, REPAIRED AND REINSTALLED TRACK IAW SRM 51-3-0, 53-2-3, 51-1-8.SDR DHL200080425CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 140 L-31 RT. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 51-1-21, 53-2-0, 51-1-8 AND 51-1-21.SDR DHL200080424CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 2 INCHES AT STA 160 L-31 RT. STOP DRILLED AND INSTALLED DOUBLER IAW 51-1-21 AND 53-2-0.SDR DHL200080423CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED .5 INCH AT STA 540 L-31 LT. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 53-2-0 AND 51-1-8.SDR DHL200080422CAngle · crackedFWD BAGGAGE COMPARTMENT REINFORCING ANGLE CRACKED 2 INCHES AT STA 180 L-31 RT. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 51-1-21 AND 53-2-0 AND 51-1-8.SDR DHL200080421CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 3 INCHES AT STA 220 FROM L-33 TO L-34 RT. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 51-1-21 AND 53-2-0.SDR DHL200080415CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 400 L-31 RT. REMOVED CRACKED ANGLE AND REPLACED WITH NEWLY FABRICATED ONE IAW SRM 51-1-21 AND 51-1-8 AND 53-2-0.SDR DHL200080414CIntercostal · crackedFWD BAGGAGE COMPARTMENT PRESSURE WALL LT INTERCOSTAL CRACKED 1 INCH AT STA 640. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 53-2-0 AND 51-1-8.SDR DHL200080413CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 500 L-31 RT. STOP DRILLED AND INSTALLED REINFORCING ANGLE IAW SRM 53-2-0 AND 51-1-8B.SDR DHL200080412CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 1INCH AT STA 400 L-33 LT. REMOVED OLD AND REPLACED WITH NEW FABRICATED ANGLE IAW SRM 51-1-21 AND 51-1-8 AND 53-2-0.SDR DHL200080402CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 1 INCH AT STA 500 L-31 RT. STOP DRILLED IAW SRM 53-2-0 FIG 1B. FABRICATED REINFORCING ANGLE IAW SRM 53-2-0 FIG 18. CLEANED AND PAINTED PER SRM 51-1-8B PAGE 3-4. INSTALLED REINFORCING ANGLE ON FWD BAGGSDR DHL200080401CAngle · crackedFWD BAGGAGE COMPARTMENT FRAME REINFORCING ANGLE CRACKED 1INCH AT ATA 420 L3 LT. REMOVED FASTENERS IAW 53-53-0 FIG 1B. FABRICATED AND INSTALLED DOUBLER WITH NEW FASTENERS PER SRM 51-1-21 PAGE 1.SDR UPS00832259Fitting · crackedINSPECTION TYPE:C123 LONG 19R INTERCOSTAL ATTACH FITTING CRACKED FS 834. REMOVED, FAB AND REPLACED FITTING IAW DWG 3779874 & SRM 51-1-20D.SDR UPS00832197Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE. FOUND SWITCH IN ON POSITION. REMOVED AND REPLACED EMERGENCY BATTERY PACK OPS CHECK OK IAW 33-50-0 2.SDR DHL200080448CFloorboard · crackedMAIN CARGO NR 60 FLOOR CRACKED. STOP DRILLED PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 53-2-3. INSTALLED DOUBLER PER SRM 53-2-3.SDR DHL200080446CFloorboard · crackedMAIN CARGO NR 2D FLOOR CRACKED. STOP DRILLED PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-3.SDR DHL200080445CFloorboard · crackedMAIN CARGO COMPT 2C FLOOR CRACKED. STOP DRILLED PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER ON CARGO FLOOR PER SRM 53-2-0.SDR DHL200080444CFloorboard · corrodedMAIN CARGO COMPT 6A FLOOR SKIN LOWER PART SHOWS CORROSION. REMOVED CORRODED FLOOR SKIN PER SRM 51-1-21. FABRICATED NEW SKIN PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED SKIN PER SRM 53-2-0.SDR DHL200080443CFloorboard · crackedMAIN CARGO COMPT 3D FLOOR CRACKED 1 INCH AT STA 724.00. STOP DRILLED PER SRM 51-1-21. FABRICATED DOUBLER PER SRM 53-2-3. CLEANED,TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-3.SDR DHL200080442CFloorboard · crackedMAIN CARGO COMPT FLOOR CRACKED .5 INCH. STOP DRILLED PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. INSTALLED DOUBLER PER SRM 53-2-3.SDR DHL200080441CFloorboard · crackedMAIN CARGO COMPT 3-D FLOOR CRACKED .5 INCH AT STA 596.00. STOP DRILLED PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-3.SDR RRXA001943Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM AT STA 1300 LT UPPER CHORD LBL 52 INCHES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 5SDR RRXA001808Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM LT UPPER CHORD AT STA 1300 AND LBL 52, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND SDR DHL2000804131Fitting · crackedMAIN CARGO FRAME FITTING SPLICE CRACKED 1 INCH AT LONGERON 22 LT STA 234.00. REMOVED DAMAGED FITTING PER SRM 51-1-20D. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW FITTING PER SRM 51-1-20.SDR DHL2000804101Floor Support · crackedMAIN CARGO SUB FLOOR CRACKED .75 INCH AT STA 100.00. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER WITH NEW HARDWEAR PER SRM 51-1-21.SDR DHL2000804129Fitting · crackedFWD BAGGAGE COMPT LONGERON BULKHEAD FITTING SPLICE CRACKED 4 INCHES BETWEEN STA 600.00 AND STA 620.00. REMOVED DAMAGED FITTING PER SRM 51-3-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW FITTING PER SRM 51-3-0.SDR DHL2000804106Angle · brokenLEFT MLG W/W SHOWS ANGLE BROKEN NEAR FS 875.125. REMOVED FASTENERS PER SRM 51-1-21. FABRICATED PATCH PER SRM 57-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED PATCH WITH NEW FASTENERS PER SRM 51-1-21.SDR DHL200080419CSkin · crackedFWD PASSENGER DOOR RT LOWER SURFACE SKIN CRACKED .5 INCH. REMOVED DAMAGED SKIN AND INSTALLED NEW SKIN IAW SRM 51-1-21 AND 51-1-8 AND 52-2-0.SDR DHL200080417CFloor Support · crackedMAIN CARGO SUBFLOOR CRACKED 2 INCHES AT STA 1160 BL 49 RT. CUT AFFECTED AREA AND INSTALLED FILLER AND DOUBLER IAW SRM 53-2-0.SDR RRXA000718Fitting · damagedDURING A MAINTENANCE VISIT FOUND THE ALIGNMENT OUT OF TOLERANCE AT THE RT FLAP FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FLAP SUPPORT FITTING IAW DC-8 SRM 27-51-12 AND DSKSDR RRXA001913Skin · tornDURING A MAINTENANCE VISIT FOUND SKIN TORN AT THE RT O/B FLAP HINGE WEDGE CUTOUT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED PER EO NR 00-055 WITH APPROVED 8110-3 DATED 3-20-00.SDR RRXA001903Frame · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN THE RT SIDE OF THE TAIL CONE INSIDE AT STA 1961, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 AND 51-1-SDR RRXA001777Skin · tornDURING A MAINTENANCE VISIT, FOUND THE SKIN TORN ON THE RT OB TE FLAP HINGE WEDGE CUT-OUT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. BLENDED CUT-OUT AND FILLED PER E.O. 00-055 WITH APPROVED 8110-3 DATED 3-SDR RRXA001767Frame · damagedDURING A MAINTENANCE VISIT FOUND A HOLE IN THE RT SIDE TAIL CONE INSIDE AT STA 1961, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21 AND 51-1-4.SDR RRXA000609Skin · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE SKIN AT STA 1648 TO 1653 AND LONGERON 22R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED PART AND INSTALLED IAW DC-8 SRM 53-2-0 FIG 16. (CORROS
Back to Douglas DC-8-73F