Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL2000804134Floor Support · crackedMAIN CARGO SUB FLOOR STA 420.00 BL 17 RT CRACKED 2 INCHES. REMOVED FASTENERS PER SRM 51-1-21. CUT DAMAGED AREA PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21 WITH NEW FASTENSDR DHL2000804133Radome · crackedRADOME INNER SKIN CRACKED 1 INCH AT 3 O''CLOCK LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-5. FABRICATED DOUBLER PER SRM 53-2-5. CLEANED TREATED AND PRIMED PER 51-1-8. INSTALLED DOUBLER PER SRM 53-2-5. INSTALLED NEW FASTENERS PER SRMSDR DHL200080494CRib · crackedLEFT WING T/E FLAP LINKS AND STRUCTURE RIB CRACKED AT STA 19.000. STOP DRILLED PER SRM 57-2-0. FABRICATED ANGLE PER SRM 52-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE PER SRM 57-20-0.SDR DHL200080493CAngle · brokenLT MLG W/W SHOWS ANGLE BROKEN NEAR FS 857.125. REMOVED FASTENERS PER SRM 51-1-21. FABRICATED PATCH PER SRM 57-2-0. CLEANED TREATED AND PAINTED PER SRM 51-1-8. INSTALLED PATCH PER SRM 51-1-21.SDR DHL200080492CFrame · crackedCENTER ACCY COMPT INTERIOR FRAME SUPPORT FLANGE CRACKED 2 INCHES AT STA 620.000 BETWEEN L26 AND L27 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED TREATED AND PRIMED PER SRM 51-1-8. INSSDR DHL200080491CFrame · crackedCENTER ACCY COMPT INTERIOR FRAME FLANGE CRACKED 2 INCHES AT STA 620.00 BETWEEN L-26 AND L-27 RT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED CRACK PER SRM 53-2-0. FABRICATED DOUBLER PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLEDSDR DHL2000804103Angle · crackedLEFT WING T/E FLAP LINKS AND STRUCTURE UPPER SKIN SUPPORT ANGLE CRACKED 1 INCH AT XW 19-00. REMOVED DAMAGED SUPPORT ANGLE PER SRM 51-1-21. STOP DRILLED PER SRM 57-2-0. FABRICATED SUPPORT ANGLE PER SRM 51-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSDR DHL200080438CFloor Support · brokenAFT BAGGAGE COMPT LATERAL FLOOR SUPPORT BROKEN AT BS 580.00 L-31 RT. REMOVED SUPPORT PER SRM 51-1-71 PG 1. FABRICATED SUPPORT PER SRM 51-1-71. CLEANED, TREATED AND PRIMED PER SRM 51-1-8 PG 17 - 18. INSTALLED SUPORRT PER SRM 53-2-0.SDR DHL2000804121Floor Support · crackedMAIN CARGO SUB FLOOR STA 615.000 BL 54 RT CRACKED 1 INCH. REMOVED FASTENERS PER SRM 51-1-21. CUT OUT DAMAGED AREA PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 53-2-3. TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 51-1-21.SDR DHL2000804120Floor Support · crackedMAIN CARGO SUB FLOOR STA 420.000 BL 17 RT CRACKED 2 INCHES. REMOVED DAMAGED SKIN PER SRM 51-4-21. FABRICATED NEW SKIN PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW SKIN PER SRM 51-1-21.SDR DHL2000804119Floor Support · crackedMAIN CARGO SUBFLOOR CRACKED 1 INCH AT STA 1344.00 BL 37 LT. REMOVED DAMAGED SKIN PER SRM 51-4-21. FABRICATED NEW SKIN PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW SKIN PER SRM 51-1-21.SDR DHL2000804128Radome · crackedRADOME INTERNAL ZONE CRACKED 1 INCH AT 8 O''CLOCK POSITION RT. REMOVED FASTNERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-5. FABRICATED DOUBLER PER SRM 53-2-5. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED DOUBLER PER SRM 53-2-5. INSTALLED NEW FSDR DHL200080429CFloor Support · crackedFWD BAGGAGE COMPARTMENT FLOOR SUPPORT AT BS 420.00 BETWEEN L-34 LT TO L-36 CRACKED 1INCH AND 2 INCH. STOP DRILLED AND INSTALLED DOUBLER IAW SRM 51-1-21 AND 53- 2-3.SDR DHL200080428CFloor Support · brokenFWD BAGGAGE COMPARTMENT LATERAL FLOOR SUPPORT BROKEN AT STA BS 360.000 TO BS 420.000 NEAR LONGERON 31BL. REMOVED DAMAGED FLOOR SUPPORT AND REPLACED WITH FABRICATED ONE IAW SRM 51-1-21 AND 53-2-0.SDR DHL2000804117Cargo Track · brokenMAIN CARGO COMPT NR 2 RT TRACK LUGS BROKEN AT STA 310.00. REMOVED DAMAGED TRACK PER SRM 51-3-0. FABRICATED SPLICE PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED SPLICE AND NEW TRACK PER SRM 51-3-0.SDR DHL2000804115Cargo Track · brokenMAIN CARGO COMPT NR3 TRACK RT LUG BROKEN AT STA 130.00 TO STA 300.00. REMOVED DAMAGED TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW TRACK AND SPLICE PER SRM 53-2-3.SDR DHL2000804114Cargo Track · damagedMAIN CARGO COMPT NR 1TRACK AT STA 150.00. REMOVED TRACK PER SRM 51-1-21. INSTALLED NEW TRACK PER SRM 53-2-3.SDR DHL2000804113Cargo Track · brokenMAIN CARGO COMPT NR 2 RT TRACK LUG BROKEN AT STA 140.00 TO STA 240.00. REMOVED BROKEN TRACK PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW TRACK PER SRM 53-2-3.SDR DHL2000804111Cargo Track · brokenMAIN CARGO COMPT NR 2 RT TRACK LUG BROKEN AT STA 310.00. REMOVED DAMAGED TRACK PER SRM 51-3-0. FABRICATED SPLICE PER SRM 53-2-3. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED SPLICE AND TRACK PER SRM 53-2-3.SDR DHL2000804110Cargo Track · brokenMAIN CARGO COMPT NR 2 RT TRACK FLANGE BROKEN BETWEEN STA 1600.00 AND 1620.00. REMOVED DAMAGED TRACK PER SRM 51-1-21. INSTALLED NEW TRACK PER SRM 53-2-3.SDR DHL2000804109Cargo Track · brokenMAIN CARGO COMPT NR 2 LT TRACK FLANGE BROKEN BETWEEN STA 1530.00 AND 1580.00. REMOVED AND REPLACED TRACK IN MAIN CARGO COMPT BETWEEN STA 1580.00 AND 1600.00 PER SRM 53-2-3 PG 50.SDR DHL2000804108Cargo Track · brokenMAIN CARGO COMPT 2 RT TRACK FLANGES BROKEN BETWEEN STA 160.00 AND 180.00. REMOVED DAMAGED TRACK PER SRM 51-3-0. CLEANED TREATED AND PRIMED PER SRM 51-1-8. INSTALLED NEW TRACK PER SRM 51-1-20 AND 51-3-0.SDR DHL2000804107Cargo Track · brokenMAIN CARGO COMPT NR 1 TRACK FLANGES BROKEN BETWEEN STA 320.00 AND 340.00. REMOVED BROKEN TRACK PER SRM 53-2-3. FABRICATED SPLICE PER SRM 53-2-3. CLEANED TREATED AND PRIMED PER SRM 51-1-8. INSTALLED TRACK AND SPLICE PER SRM 53-2-3.SDR DHL200080434CFloor Support · crackedFWD BAGGAGE COMPT FLOOR SUPPORT SHOWS 2 CRACKS OF 1 AND 2 INCH AT BS 360.00 L 34 TO L 36. REMOVED FASTENERS PER SRM 51-3-0 PG 15. STOP DRILLED PER SRM 53-2-3. FABRICATED DOUBLER PER SRM 51-1-8 PG 17-18. CLAENED, TREATED AND PAINTED PER SRM 51-1-8. INSTALLSDR DHL200080433CFloor Support · crackedFWD BAGGAGE COMPATMENT FLOOR SUPPORT CRACKED 2 INCHES AT BS 520.00 BETWEEN L35 AND L36 LT. REMOVED FASTENERS PER SRM 51-1-21. STOP DRILLED PER SRM 53-2-3 FIG 5. FABRICATED DOUBLER PER SRM 53-2-3. INSTALLED DOUBLER WITH NEW FLOOR SUPPORT PER SRM 51-1-21-PG SDR DHL200080427CAngle · crackedCENTER WING (MAIN CARGO) CENTRAL TANK UPPER SKIN ANGLE CRACKED AT 857 BL-22 RT. INSTALLED ANGLE IAW SRM 51-2-0 AND 51-1-21.SDR DHL200080418CCargo Track · brokenMAIN CARGO CENTER TRACK LUG BROKEN AT STA 150. REMOVED AND REPLACED DAMAGED TRACK IAW SRM 51-1-21 AND 53-2-3.SDR DHL200080416CFloor Support · crackedMAIN CARGO SUB FLOOR CRACKED .25 INCH AT STA 220 BL 34 LT. CUT DAMAGED AREA AND INSTALLED FILLER AND DOUBLER IAW SRM 53-2-0 AND 51-1-8.SDR UPS00832321Frame · corrodedINSPECTION TYPE:C1 STA 1260 FRAME IS CORRODED BEYOND LIMITS AFT SIDE AT LONG 36. REPAIRED IAW SRM 53-2-0 FIG 2.SDR RRXA003392Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT AFT CARGO TRACK AT FS 1020 TO 1120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-3-0 AND DWG 5754223.SDR RRXA002024Skin · dentedDURING A MAINTENANCE VISIT FOUND DENTS AND BARE METAL TO THE AFT LWR CARGO COMPARTMENT AFT DOOR OUTSIDE SKIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW EO NR 00-SDR RRXA002022Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AT THE C-PIT DOOR IN WEB INSIDE LWR PORTION OF DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 52-2-0 SDR RRXA001989Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE AFT PRESSURE BULKHEAD I BEAM LOWER SUPPORT FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 51-1-20D.SDR RRXA001969Hinge · looseDURING A MAINTENANCE VISIT FOUND PLAY ON LEFT MAIN LANDING GEAR DOOR HINGES AT AIRFRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW HINGE IAW DC-8 SRM 51-1-20D AND 51-3-0.SDR RRXA001966Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW CLIP IAW DC-8 SRM 51-1-21, SDR RRXA001965Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 963, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW CLIP IAW DC-8 SRMSDR RRXA001964Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 955, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW CLIP IAW DC-8 SRSDR RRXA001963Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 963, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW CLIP IAW DC-8 SRMSDR RRXA001956Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CAPTS LT AFT SEAT TRACK LOCK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK IAW DC-8 SRM 51-3-0, 53-2-0 AND 51SDR RRXA001955Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CAPT''S RT AFT SEAT TRACK LOCK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK IAW DC-8 SRM 51-3-0, 51-1-24 ANDSDR RRXA001954Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE F/O''S RT AFT SEAT TRACK LOCK HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW TRACK IAW DC-8 SRM 51-3-0, 53-2-0SDR RRXA001934Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN 3 PLACES TO THE LEFT I/B AILERON O/B END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND EO NR 00-055SDR RRXA001890Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENT AND BARE METAL AT THE AFT LWR CARGO COMPT AFT DOOR OUTSIDE SKIN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-SDR RRXA001888Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE C-PIT DOOR IN WEB INSIDE LWR PORTION, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-21, 52-2-0 AND 51-SDR RRXA001854Support Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN THE AFT PRESSURE BULKHEAD I BEAM LOWER SUPPORT FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTING IAW DC-8 SRM 51-1-20D.SDR RRXA001834Hinge · looseDURING A MAINTENANCE VISIT FOUND PLAY IN THE I/B LEFT MLG DOOR HINGES ON AIR FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED HINGE IAW DC-8 SRM 51-1-20D AND 51-3-0.SDR RRXA001831Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 945, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW CLIP IAW DC-8 SRMSDR RRXA001830Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 963, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED CLIP IAW DC-8 SRM 51-SDR RRXA001829Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 955, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED CLIP IAW DC-8 SRM 51-SDR RRXA001828Clip · crackedDURING A MAINENANCE VISIT FOUND A CRACK TO THE RT MAIN LANDING GEAR DOOR HINGE BEAM ATTACH CLIP AT STA 963, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED CLIP IAW DC-8 SRM 53-2
Back to Douglas DC-8-73F