Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS97822995Skin · corrodedINSPECTION TYPE:D, F/S 220-270 BETWEEN STR 31L-31R SKIN AND INTERNAL DOUBLER HAVE NUMEROUS AREAS OF MODERATE CORROSION. REMOVED AND REPLACED SKIN FS 190-450 LONG 31L TO 31R PER UPS E.O. DC8-5330-7427-B, SRM 51-1-29D, 51-1-21, 51-3-0, AND 51-1-11.SDR UPS97822994Intercostal · exfoliatedINSPECTION TYPE:D, F/S 998 LONG 27R INTERCOSTAL EXFOLIATED. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT INTERCOSTAL IAW SRM 53-1-0, 51-1-20, AND DWG 5640915.SDR UPS97822991Intercostal · corrodedINSPECTION TYPE:D, INTERCOSTAL EXFOLIATED AFT OF FRAME 980 AT LONG 35L. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT INTERCOSTAL PER SRM 53-4-1 AND 51-1-20D.SDR UPS97822988Longeron · crackedINSPECTION TYPE:D, F/S 1656 LONGERON 33R IS CRACKED AT ATTACH FITTING. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT LONGERON IAW SRM 51-1-21, 53-2-2 FIG 10 AND 51-1-20.SDR UPS97822976Frame · corrodedINSPECTION TYPE:D, F/S 1080 FRAME WEB FWD SIDE EXFOLIATED OUTBOARD OF LONG 35R. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-2-0 FIG1F, 51-1-29D, AND 51-1-21.SDR UPS97822913Gusset · corrodedINSPECTION TYPE-D, FS 140 AT STR 27R FLOOR SUPPORT TIE FITTING TO FRAME HAS SEVERE CORROSION. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT GUSSET IAW SRM 53-1-0.SDR UPS97822904Cusp · corrodedINSPECTION TYPE-D, FUSELAGE LT CUSP BOTTOM SIDE EXFOLIATED FS 1154. REMOVED CUSP FROM FS 1130 TO 1170, FABRICATED AND INSTALLED REPAIR PART AND DOUBLERS IAW SRM 53-2-5 FIG 15, 51-1-20D. CUT AND SPLICED FRAME FS 1140 LT IAW SRM 53-2-0 FIG 2.SDR UPS97822899Fitting · crackedINSPECTION TYPE-D, FS 153 AT RT CUSP TIE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS97822867Frame · corrodedINSPECTION TYPE-D, FRAME CORRODED AT STA 420, LONGERON 35L. REMOVED CORROSION AND DAMAGED AREA, FABRICATED AND INSTALLED REPAIR IAW SRM 53-2-0 FIG 2, 51-1-8.SDR UPS97822865Splice · crackedINSPECTION TYPE-D, LONG 31R SPLICE FITTING CRACKED FS 1050. REMOVED AND INSTALLED REPLACEMENT FITTING PER SRM 51-1-20D.SDR UPS97822863Shear Tie · corrodedINSPECTION TYPE-D, FS 280 BTWN STR 34L AND 35L SKIN AND SHEAR TIE FITTING HAVE CORROSION. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D, SKIN REPLACED ON N/R 534855.SDR UPS97822857Fitting · corrodedINSPECTION TYPE-D, EXFOLIATION CORROSION ON AFT SIDE OF FRAME FITTING FS 960 LT WW O/B AFT ABOVE LONG 24. REMOVED AND REPLACED FITTING IAW SRM 53-2-0 FIG 8 AND 51-1-20.SDR UPS97822851Fitting · corrodedINSPECTION TYPE-D, FLOORBEAM END FITTING ABOVE C-3 DOOR FS 1200 EXFOLIATED. REMOVED AND REPLACED END FITTING IAW SRM 51-1-20D.SDR UPS97822847Fitting · corrodedINSPECTION TYPE-D, FS 70 AFT SIDE, STR 34R END FITTING IS CORRODED. REMOVED AND REPLACED FITTING IAW SRM 51-3-0, 51-3-1.SDR UPS97822825Frame · corrodedINSPECTION TYPE-D, FRAME CAP FS 1050 AFT LOWER SIDE EXFOLIATED AT 2 NUT PLATES BETWEEN LONG 36 AND 35L. REMOVED DAMAGE, FABRICATED AND INSTALLED ANGLE AND STRAP IAW SRM 53-2-0, AND 51-1-20.SDR UPS97822801Gusset · corrosionINSPECTION TYPE:D, FLOORBEAM TO FRAME TIE GUSSET HAS SEVERE CORROSION AT FS 220 STR 27R. FABRICATED AND INSTALLED REPLACEMENT GUSSET IAW SRM 53-4-3, 51-1-8, AND 51-1-20.SDR UPS97822796Stringer · corrosionINSPECTION TYPE:D, FS 140-148 STR 36 IS CRACKED IN 2 PLACES DUE TO CORROSION. REMOVED, FABRICATED, AND INSTALLED LONGERON SECTION W/SPLICE FROM FS 130-150 IAW SRM 51-1-20, 53-2-2 FIG 10, 53-2-0, AND 51-1-8.SDR UPS97822794Stringer · corrodedINSPECTION TYPE:D, FS 100-140 STR 36 HAS SEVERE CORROSION. REMOVED, FABRICATED, AND INSTALLED LONG IAW SRM 53-2-2 FIG 10, 51-1-20, 53-2-0, AND 51-1-8.SDR UPS97822793Fitting · corrodedINSPECTION TYPE:D, FS 70 AFT SIDE STR 25R END FITTING IS CORRODED. REMOVED AND REPLACED FITTING IAW SRM 53-1-0, 51-1-21, 51-1-20D, AND 51-3-0.SDR UPS97822780Splice · crackedINSPECTION TYPE:D, LONGERON 31L SPLICE BETWEEN FS 380-400 CRACKED. REMOVED AND REPLACED SPLICE FITTING IAW SRM 51-1-20.SDR UPS97822778Intercostal · corrodedINSPECTION TYPE:D, UPPER AND LOWER FLANGES OF INTERCOSTAL CORRODED AT FS 1100 TO 1120 LONGERON 33R. REMOVED, FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL IAW SRM 51-1-21, 51-1-20D AND 51-1-30.SDR UPS97822770Frame · corrosionINSPECTION TYPE:D, FRAME FWD SURFACE HAS MODERATE CORROSION AT FS 500 ABOVE LONGERON 32R. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR PART IAW SRM 51-1-8, 53-2-0, 51-1-20.SDR UPS97822766Pin · crackedINSPECTION TYPE:D, ULTRASONIC INSPECTION DETECTED A CRACK ON THE MAIN LANDING GEAR BOGIE PIVOT PIN. REMOVED AND REPLACED BOGIE PIVOT PIN IAW M/M 32-11-05.SDR UPS97822587Tail Skid Ftg · corrosionINSPECTION TYPE-D, TAIL SKID FITTING INSIDE FUSELAGE AT FS 1766 HAS EXFOLIATED CORROSION. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D, 51-3-0, 51-3-1.SDR UPS97822989Cusp · corrodedINSPECTION TYPE:D, F/S 1152 RT CUSP ANGLE HAS HEAVY CORROSION EXTENDING UNDER FRAME FITTING. REMOVED DAMAGED SECTION OF CUSP FS 1180-1250, FABRICATED AND INSTALLED RELACEMENT SECTION OF CUSP, DOUBLERS, AND SPLICE IAW SRM 53-2-5 FIG 15A, 51-1-21D. (WORKED WIYHSDR UPS97822870Angle · corrodedINSPECTION TYPE-D, FS 1340 RT SIDE AT FLOOR LEVEL DOOR JAMB TIE ANGLE HAS HEAVY CORROSION. REMOVED, FABRICATED AND INSTALLED DOOR ANGLE IAW SRM 53-4-3, 51-1-21.SDR UPS97822821Angle · corrodedINSPECTION TYPE-D, FS 902 RBL 59 TO 63 FRAME TO FUSELAGE TIE ANGLE HAS HEAVY CORROSION BELOW FLOOR AFT SIDE. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS97822820Channel Web · corrodedINSPECTION TYPE-D, MAIN DECK FLOOR CHANNEL AND WEB BETWEEN LBL 7 TO 20 FS 1740 HAS MODERATE CORROSION ON UPPER AND LOWER SURFACE. REMOVED FLOOR CHANNEL AND WEB AND COLLAR PLATE, FABRICATED REPLACEMENT PARTS PER SRM 53-1-0 AND INSTALLED PARTS IAW SRM 51-1-21, SDR UPS97822819Frame · corrodedINSPECTION TYPE-D, FS 940 FRAME LT SIDE BELOW FLOOR HAS HEAVY CORROSION. REMOVED, FABRICATED AND INSTALLED FRAME SECTION IAW DHC SK-894-614, REF UPS ENRG FILE NR DC8-53-1771, SRM 51-1-20, 53-2-0.SDR UPS97822792Fitting · crackedINSPECTION TYPE:D, FS 902 FWD SIDE AT STR 18R - INTERCOSTAL TIE FITTING CRACKED. REMOVED, FABRICATED, AND INSTALLED FITTING IAW SRM 51-1-20, 53-1-0, AND DOUGLAS DWG 4750423.SDR UPS97822791Frame · corrosionINSPECTION TYPE:D, FS 940 FRAME RT SIDE BELOW FLOOR HAS HEAVY CORROSION AT BOTTOM. REMOVED AND REPLACED FRAME IAW DOUG DWG 5751966 AND SRM 53-1-0, 51-1-1, 51-1-20, AND DHC SK-894-616 REF UPS ENRG FILE NR DC8-53- 1772.SDR UPS97822774Fitting · corrodedINSPECTION TYPE:D, FS 895 TIE ANGLE TO FRAME AND SKIN HAS HEAVY CORROSION LEFT SIDE BELOW FLOOR. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR UPS97822769Fitting · corrodedINSPECTION TYPE:D, FS 857 FWD SIDE AT STR 19R, 2 INTERCOSTAL ATTACH FITTINGS ARE CRACKED AND 1 CORRODED. REMOVED, FABRICATED, AND INSTALLED ATTACH FITTINGS IAW DOUG DWG 4750423, SRM 53-1-0, 53-2-0 FIG 1F, 51-1-8, AND 51-1-20. (1 FITTING WITHIN LIMITS)SDR UPS97822768Intercostal · crackedINSPECTION TYPE:D, FS 857 AFT SIDE AT STR 19R, INTERCOSTAL TIE FITTING IS CRACKED. REMOVED, FABRICATED, AND INSTALLED FITTING IAW DOUG DWG 4750423, SRM 53-1-0, 51-1-8, 51-1-20.SDR UPS97822668Fitting · crackedINSPECTION TYPE:D, STA 70 END FITTING AT STRINGER 31R FWD SIDE TOP SPLICE FITTING HAS A CRACK. REMOVED AND REPLACED FITTING IAW SRM 51-1-21 (REF N/R 610087 AND 610087 FOR INSTL).SDR UPS97822659Fitting · corrodedINSPECTION TYPE:D, STA 270 BETWEEN STR 35R-36 FITTING IS CORRODED (REF N/R 610832 ). REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FITTING IAW SRM 53-2-0, 51-1-20D, 51-3-0, AND DWG 3755822.SDR UPS97822603Frame · corrodedINSPECTION TYPE-D, BODY FRAME HAS EXFOLIATED CORROSION AT STA 1380 BETWEEN LONGERONS 3R AND 4R. REMOVED CORROSION, TREATED AND PRIMED PER SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-2-0 FIG 7, 51-1-21 AND 51-1-20D.SDR UPS97822532Angle · crackedINSPECTION TYPE-D, LT HORZ STAB L/E REPAIR ANGLE CRACKED AT STA FXS53.7. REMOVED, FABRICATED AND INSTALLED REPAIR ANGLE IAW SRM 55-2-0 AND 51-1-20D.SDR UPS97822872Chord · corrodedINSPECTION TYPE-D, FS 70 CHORD (AFT) AT STR 27R TO 35R HAS HEAVY CORROSION. REMOVED SECTION OF AFT CHORD FROM BTWN LONG 32 TO 33R TO LONG 21R, FABRICATED REPAIR PARTS AND EXTERNAL DOUBLER AND INSTALLED IAW SRM 53-2-5 FIG 8C-2, 51-1-21, 51-1-20D AND 51-3-1.SDR UPS97822826Shear Tie · crackedINSPECTION TYPE-D, FS 270 BETWEEN STR 32R AND 33R SHEAR TIE IS CRACKED IN 2 PLACES. REMOVED CRACKED FITTING AND INSTALLED NEW IAW SRM 53-20-0.SDR UPS97822822Support Fitting · crackedINSPECTION TYPE-D, C-1 CARGO PIT AT FS 280 RT SIDE FLOORBEAM SUPPORT FITTING ABOVE STR 27R IS CRACKED AND CORRODED. REMOVED, FABRICATED AND INSTALLED REPLACEMENT FITTING IAW DWG 9754024 AND SRM 51-1-20D.SDR UPS97822790Skin · corrodedINSPECTION TYPE:D, FS 1690-1700 BETWEEN STR 30R-32R, SKIN INTERNALLY HAS LARGE AREA OF CORROSION. REMOVED AND REPLACED SKIN FROM STA 1690-1890 LONG 28L-28R IAW DWG 5649329 AND SRM 51-1-21, 51-1-20D, AND 51-1-8.SDR UPS97822787Angle · corrodedINSPECTION TYPE:D, FS 1740 FLOORBEAM ANGLE HAS HEAVY CORROSION AT RBL 20-30. REMOVED, FABRICATED AND INSTALLED REPLACEMENT ANGLE PER SRM 51-1-20 AND DWG 5755032.SDR UPS97822779Splice · crackedINSPECTION TYPE:D, FS 440-460 STR 31R SPLICE FITTING IS CRACKED. REMOVED AND REPLACED IAW SRM 51-1-20D.SDR UPS97822772Splice · crackedINSPECTION TYPE:D, FS 200-220 STR 31L, SPLICE FITTING IS CRACKED. REMOVED AND REPLACED SPLICE FITTING PER SRM 51-1-20 AND 53-10-1.SDR UPS97822767Splice · crackedINSPECTION TYPE:D, FS 460-440 STR 31L SPLICE FITTING CRACKED. REMOVED AND REPLACED SPLICE FITTING IAW SRM 51-1-20D.SDR UPS97822602Angle · crackedINSPECTION TYPE-D, LT WING L/E VERTICAL ANGLE AT AFT OTBD CORNER OF SLOT HOUSING CRACKED. REMOVED, FABRICATED AND INSTALLED REPLACEMENT ANGLE IAW SRM 51-3-0 AND DAC DWG 5769859.SDR UPS97823060Torque Tube · crackedINSPECTION TYPE:D, RT WING L/E SECTION BETWEEN PYLONS, O/B SLOT TORQUE TUBE AT I/B END IS CRACKED IN HALF. REMOVED AND REPLACED CRANK IAW SRM 51-1-21.SDR UPS97822592Intercostal · corrosionINSPECTION TYPE-D, INTERCOSTAL AT LONG 33R FROM FS 1120 TO 1140 CORROSION BEYOND LIMITS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT INTERCOSTAL IAW SRM 53-4-1, 51-1-21, AND 51-1-8.SDR UPS97822585Rib · crackedINSPECTION TYPE-D, LT NR 2 ENG L/E STUB WING L/E RIB UPPER AFT END CRACKED, THIRD RIB FROM I/B END. FABRICATED AND INSTALLED ANGLE PER SRM 57-2-0 FIG 2.
Back to Douglas DC-8-73F