Douglas DC-9-32
Service difficulty reports · 12,755
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR VJ970355Antiskid Syst · malfunctionedAFTER LANDING, WITH REVERSE THRUST APPLIED, UNABLE TO OBTAIN BRAKING FORCE UNTIL ANTI-SKID TURNED OFF. RELEASED BRAKES AND OPS CHECKED ANTI-SKID SYSTEM; NO DEFECTS NOTED AND SYSTEM CHECKED NORMAL. AIRCRAFT FERRIED FROM BOS TO IAD AND BRAKING SYSTEM REPORTED SDR MWEA97859Slide Cover · fell offCREW REPORTS, GALLEY SERVICE DOOR ESCAPE SLIDE COVER FELL OFF. MTC INSTALLED GALLEY DOOR SLIDE COVER.SDR CALA9701749Skin · dentedINSPECTION FOUND FUSELAGE SKIN DENTED AT FS 100, LONGERON 24L. THE DENTED AREA WAS REMOVED. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-04-0 AND 51-10-3.SDR MWEA97854Angle · crackedDURING C-CHECK, FOUND THE ATTACH ANGLE ON BOTTOM OF TRAP PANEL IN LEFT WHEEL WELL CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-30-2 AND 51-30-5.SDR ABXA9701904Tr Link · crackedDURING COMPLIANCE WITH AD 96-10-11 AND 75-14-06, FOUND FORWARD, UPPER RIGHT THRUST REVERSER LINK CRACKED. REPLACED THRUST REVERSER DRIVE LINK IAW DC9 MM 78-31-5.SDR A3L297122Tie Bolt · brokenINSPECTION FOUND WHEEL WITH BROKEN TIE BOLT. (X)SDR VJ970354Battery Pack · dischargedAFT SECTION OF OVERHEAD EMERGENCY LIGHTS INOP. REPAIRED WIRING AT AFT GALLEY DOME LIGHT ASSY. REPLACED EMERGENCY LIGHT BATTERY PACK, OPS CHECKED GOOD IAW MM 33-50.SDR ABXA9701905Window · bindingCAPTAIN'S CLEARVIEW WINDOW (EMERG EXIT) WOULD NOT OPEN WITH NORMAL PRESSURE. LUBRICATED CAPTAIN'S CLEARVIEW WINDOW AND RESECURED WINDOW TRIM.SDR A3L297121Tie Bolt · brokenINSPECTION FOUND WHEEL WITH BROKEN TIE BOLT. (X)SDR VJ970353Battery · dischargedFORWARD OVERHEAD CABIN EMERGENCY LIGHTS INOP. REPLACED NICAD BATTERIES IN BATTERY PACK TO CABIN EMERGENCY LIGHT, OPS CHECKED GOOD IAW MM 33-50.SDR MWEA97850Battery Pack · dischargedDURING B-CHECK, FOUND EMERGENCY FLOOR LIGHTING WOULD NOT LIGHT UP. MTC REMOVED AND REPLACED BATTERY PACK.SDR 9722759950Longeron · crackedDURING H-CHECK, FOUND CRACK IN LOWER PANEL STRINGER OF AUXILIARY FUEL TANK IN FORWARD CARGO COMPARTMENT LBL 13. REPAIRED PER EA 99-154054.SDR TWAA9714003Line · leakingSTL - FLT 694 - DURING CRUISE AND APPROACH, AN AIR LEAK WAS HEARD COMING FROM THE PASSENGER OXYGEN BOTTLE RELIEF LINE. REPLACED THE PASSENGER THERMAL OVERBOARD RELIEF LINE. (M)SDR ABXA9701901Battery · dischargedDURING PREFLIGHT, COCKPIT OVERHEAD EMERGENCY LIGHT DID NOT ILLUMINATE. REPLACED EMERGENCY LIGHT BATTERY PACK, OPS CHECKED GOOD.SDR 9722399613Power Supply · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND OVERHEAD EMERGENCY LIGHTS AT ROWS 16, 18, AND 20 INOPERATIVE. REPLACED POWER SUPPLY B5-27, OPERATIONAL CHECK NORMAL.SDR CALA9701683Transformer · failedTHE FLIGHT ATTENDANT REPORTED SMOKE IN THE LT AFT LAV AFTER LANDING AT IAH. THERE WERE NO VISIBLE SIGNS OF FIRE. THE HALON FIRE BOTTLE IN AFT LAV AND AFT WATER FIRE EXTINGUISHER WERE USED AND THE SMOKE CEASED. THE AIRCRAFT ARRIVED SAFELY AT THE GATE. MAINTSDR CALA9701703Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED ON BOTH LT AND RT SIDES OF BS 996. THE CORRODED SECTIONS WERE REMOVED, FILLER AND DOUBLER REPAIRS WERE FABRICATED AND INSTALLED IAW SRM 53-05, FIGURE 108, SRM 51-10-4, 51-10-3, 51-30-2, 51-30-5, AND 51-30-1.SDR CALA9701682Union · leakingTHE LT HYDRAULIC SYSTEM QUANTITY AND PRESSURE WERE LOST WHILE AT CRUISE. APPROPRIATE CHECKLIST ITEMS WERE ACCOMPLISHED AND THE AIRCRAFT WAS RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND AFT FUSELAGE HYDRAULIC FILTER UNION LEAKING AT LT SDR CA971208011Link · cracked(CAN) ON ROUTINE "C" CHECK, NR1 ENGINE THRUST REVERSER UPPER INBOARD DRIVE LINK FOUND CRACKED. NEW MODIFIED LINK INSTALLED.SDR 9722509619Slide · low pressureDURING LINE MAINTENANCE INSPECTION, FOUND TAIL CONE EVACUATION SLIDE LOW ON PRESSURE. REPLACED SLIDE.SDR VJ970350Longeron · chafedSTA 1019 FRAME CHAFED APPROXIMATELY .035 DEEP AT L14. CUT OUT DAMAGE AND INSTALLED FILLER AND DOUBLER PER SRM 53-03, FIG 4.SDR TWAA9713902Hyd Line · chafedSTL - FLT 358 - DURING DESCENT, RIGHT HYDRAULIC QUANTITY WENT TO ZERO. FOLLOWED QUICK REFERENCE HANDBOOK PROCEDURES. REPLACED HYDRAULIC LINE P/N 7912697-504 AND LEAK CHECKED. (M)SDR MWEA97851Escape Slide · fell offTHE MAIN CABIN DOOR ESCAPE SLIDE FELL OFF. MTC REINSTALLED CABIN DOOR ESCAPE SLIDE.SDR MWEA97848Evac Slide · detachedCREW REPORTS MAIN CABIN DOOR ESCAPE SLIDE FELL OFF IN ATL. MTC REINSTALLED FWD ENTRY DOOR EVAC SLIDE.SDR 9724739610Bulkhead Skin · crackedDURING PERIODIC CHECK, FOUND CRACK IN AFT PRESSURE BULKHEAD SKIN AT LOWER RIGHT CORNER. REPAIRED PER EA 96-154147.SDR VJ970349Slide Cover · dislodgedMAIN CABIN DOOR EMERGENCY SLIDE COVER DISLODGED. REINSTALLED COVER IAW MM 25-60-00, PERFORMED REQUIRED INSPECTION AND FOUND OK FOR SERVICE.SDR MWEA97846Battery · dischargedDURING TRANS CHECK, FOUND AFT UPPER EMERGENCY FLASHLIGHT INOP. MTC REMOVED AND REPLACED BATTERY, OPS CHECK GOOD.SDR GTIA9700405Fire Loop · malfunctionedCLIMBING THROUGH 8,000 FEET THE 'A' LOOP LIGHT CAME ON AS WELL AS THE LIGHT FOR NR 1 ENGINE, WENT TO 'B', TEST OK. GROUND OPS CHECKED NR 1 ENGINE FIRE LOOP SYSTEM IAW 26-12-0. COULD NOT DUPLICATE PROBLEM. UNIT OPS CHECKS GOOD. NO DEFECTS NOTED AT THIS TIMESDR 9722909950Fitting · crackedDURING H-CHECK, FOUND CRACK IN LONGERON 30L END FITTING AT FS 605. REPLACED END FITTING PER SRM 51-01-1.SDR VJ970348Light · inoperativeEMERGENCY PATH LIGHTS IN AFT TAIL COMPARTMENT INOPERATIVE. REPAIRED SHORT AT TAIL CONE LIGHT AND REPLACED BLOWN FUSE IN EPL BATTERY PACK MODULE.SDR CALA9701678Spar Cap · crackedINSPECTION FOUND A 2 INCH CRACK AT OUTBOARD END OF RT HORIZONTAL STABILIZER LOWER SPAR CAP. THE OUTBOARD FITTING AND BULKHEAD WERE REMOVED IAW SRM 51-30-1. THE CRACKED SECTION OF SPAR WAS CUT OUT IAW SRM 55-02, FIGURE 8. A REPLACEMENT SPAR SECTION AND REPAISDR 9722099942Bulb · failedNOSE LANDING GEAR GREEN DOWNLOCK LIGHT REMAINED ON AFTER GEAR RETRACTION. FLIGHT WAS CONTINUED TO DESTINATION (MSP) AND LANDED WITHOUT INCIDENT. MAINTENANCE RELAMPED CENTER GEAR INDICATION MODULE. OPERATIONAL CHECK NORMAL. AIRCRFT RETURNED TO SERVICE.SDR 9724729601Bulkhead Doubler · crackedDURING PERIODIC CHECK, FOUND CRACK IN AFT PRESSURE BULKHEAD WEB DOUBLER (P/N 5910130-13) AT THE UPPER LEFT AND RIGHT CORNERS. REPAIRED PER EA 96-154142.SDR 9722919601Fitting · crackedDURING PERIODIC CHECK, FOUND CRACK IN AFT CABIN DOOR UPPER RIGHT STOP FITTING. REPLACED STOP FITTING PER SRM 51-10-4.SDR TWAA9713703Power Supply · inoperativeSTL - FLT 90 - EMERGENCY LIGHTS ON ALL TIME IN FIRST CLASS. ONLY WAY TO TURN OFF IS IN EMERGENCY POWER. THEY COME ON IN ARMED POSITION. REPLACED BATTERY POWER SUPPLY TWA PART NR 293-0784. (M)SDR GTIA9700407Lights · missingDTW - FLT 626 - MISSING 2 LIGHTS IN THE EMERGENCY TRACK LIGHTING (RED ONES) BY FWD EXITS. REINSTALLED LENS AND LAMPS IN EMERGENCY TRACK LIGHTING. OPS CHECK GOOD. (M)SDR CALA9701673Jamb · corrodedINSPECTION FOUND BOTTOM SECTION OF FORWARD BAGGAGE BIN DOOR JAMB PAN CORRODED. A NEW DOOR JAMB PAN WAS INSTALLED IAW SRM 51-10-3, 51-30-2, AND 51-30-5.SDR 9722839602Doubler · corrodedDURING L-CHECK, FOUND CORROSION ON FORWARD CARGO DOOR JAMB DOUBLER FS 370 TO 425. REPAIRED PER EA 96-153363.SDR CALA9701674Skin · corrodedINSPECTION FOUND INNER SKIN OF FUSELAGE CORRODED AT STA 580, LONGERON 29R. THE OUTER DOUBLER AND INNER DOUBLER WERE REMOVED AND REPLACED IAW SRM 51-30-0.SDR 9722079613Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND OVERHEAD EMERGENCY LIGHTS BETWEEN ROWS 5 THROUGH 9 INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK NORMAL.SDR MWEA97842Power Supply · inoperativeDURING SERVICE CHECK, FOUND EMERGENCY LIGHTS INOP OVER AFT FLIGHT ATTENDANTS POSITION. MTC REMOVED AND REPLACED BATTERY POWER SUPPLY IN AFT CABIN, OPS CHECK GOOD.SDR CALA9701672Skin · dentedINSPECTION FOUND A DENT IN FUSELAGE SKIN AT STA 300 BETWEEN LONGERON 26 TO 27R. A REPAIR WAS PERFORMED IAW SRM 53-04, FIGURE 12B.SDR CALA9701660Spar Cap · crackedINSPECTION FOUND A 2 INCH CRACK AT OUTBOARD END OF LT HORIZONTAL STABILIZER LOWER SPAR CAP. THE OUTBOARD FITTING AND BULKHEAD WERE REMOVED IAW SRM 51-30-1. THE CRACKED SECTION OF SPAR CAP WAS CUT OUT IAW SRM 55-02, FIGURE 8. A REPLACEMENT SECTION OF SPAR CASDR CALA9701659Spar Cap · crackedINSPECTION FOUND A 2 INCH CRACK AT OUTBOARD END OF RT HORIZONTAL STABILIZER UPPER SPAR CAP. THE OUTBOARD FITTING AND BULKHEAD WERE REMOVED IAW SRM 51-30-1. THE CRACKED SPAR SECTION WAS CUT OUT IAW SRM 55-02, FIGURE 8. A REPLACEMENT SPAR SECTION AND REPAIR ASDR CALA9701658Skin · dentedINSPECTION FOUND RT FUSELAGE SKIN DENTED AT FS 323, LONGERON 24. THE DENTED AREA WAS CUT OUT IAW SRM 53-04. A DOUBLER, FINGER DOUBLER, AND FILLER WERE FABRICATED AND INSTALLED IAW SRM 53-04, 51-10-3, 51-30-2, AND 51-30-5.SDR CALA9701657Floorbeam · corrodedINSPECTION FOUND CORROSION ON FLOORBEAM NUT PLATE AT STA 965. A DOUBLER, FILLER, AND ANGLES WERE FABRICATED AND INSTALLED IAW SRM 51-10-3, 51-30-5, AND ECRA 5320-01488.SDR CALA9701656Floor Panel · corrodedINSPECTION FOUND FLOOR PANEL AND HAT CHANNEL CORRODED UNDER PILOT'S SEAT. A NEW PANEL AND HAT CHANNEL WERE FABRICATED AND INSTALLED IAW SRM 51-30-2 AND 51-20-0.SDR CALA9701655Jamb · corrodedINSPECTION FOUND DOOR JAMB AND SUB FLOOR CORRODED AT FS 200 BY R-1 DOOR. THE CORRODED DOOR JAMB PAN AND SUB FLOOR SECTIONS WERE REMOVED IAW SRM 53-05, FIGURE 55. FILLERS AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 53-05, 51-10-3, AND 51-30-5.SDR CALA9701654Support · corrodedINSPECTION FOUND FLOORBOARD SUPPORT AT FORWARD PASSENGER ENTRYWAY CORRODED BETWEEN NR 1 SEAT TRACK AND CENTERLINE FLOORBEAM. THE FLOOR SUPPORT WAS REMOVED, A NEW SUPPORT WAS FABRICATED AND INSTALLED IAW SRM 51-10-1, 51-10-4, 51-10-3, AND 51-30-5.SDR CALA9701653Skin · dentedINSPECTION FOUND DENTS IN E AND E COMPARTMENT DOOR EXTERIOR SKIN. THE SKIN WAS REMOVED, NEW SKIN WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND 51-10-3.
Back to Douglas DC-9-32