SDR 0000659615Longeron · crackedSTATION 1095 BULKHEAD CLIP CRACKED AT LONGERON 3 RT. REPAIRED PER EA 96-172275 AND AMI 5310-00034-01B LOG PAGE 1417312.SDR 20000502SH002Power Supply · dirtyDURING ACCOMPLISHMENT OF B-CHECK WORK CARD 0617, DISCOVERED WHEN THE EMERGENCY LIGHTS WERE SELECTED TO THE ON POSITION, THE EMERGENCY LIGHTS ABOVE THE AFT OVERWING EXITS WERE INOPERATIVE. THE PROBLEM WAS TROUBLESHOT TO THE B5-25 BATTERY PACK. THE BATTERY PACKSDR AT0000168Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR SUPPORT CORRODED BEYOND LIMITS AT BS 161 - 197, RBL 44. CORRECTIVE ACTION: REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-30-02, 51-10-30, AND 5SDR L1GA200000001Light · inoperativeR1 DOOR EVACUATION SLIDE 4 LIGHTS INOPERATIVE.SDR AT0000217Longeron · corrodedFOUND BUTT SEAM AT BS 995, LONGERON 23 RIGHT TO HAVE A BULGE, D AREA. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGED AREA AND INSTALLED REPAIR IAW DC9 SRM 51-10-3, 53-04 FIGURE 12B AND EO 00.0290.SDR AT0000167Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR SUPPORT CORRODED BEYOND LIMITS AT BS 196, LBL 1-38. CORRECTIVE ACTION: REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-30-02, 51-10-02, 51-10-03, AND 51-30-SDR AT0000230Skin · lightning strikeFOUND LIGHTNING STRIKE AT WINDOW NR 25. BLENDED STRIKE, FABRICATED, AND INSTALLED REPAIR DOUBLER IAW DWG SRO9530053 AND TIMCO REO L00116.SDR AT0000229Skin · lightning strikeFOUND LIGHTNING STRIKE IN WINDOW BELT AT WINDOW NR 21. CUT OUT LOWER AFT CORNER BY BLENDING STRIKE, FABRICATED AND INSTALLED REPAIR DOUBLER IAW DWG SRO9530053 AND TIMCO L00107.SDR AT0000149Light · inoperativeFOUND TAILCONE EMERGENCY FLOOD LIGHT WILL NOT ILLUMINATE. CORRECTIVE ACTION: RELAMPED, IAW DC9 MM 33-50SDR 0001029619Power Supply · malfunctionedDURING LINE MAINTENANCE INSPECTION, FOUND CATWALK EMERGENCY LIGHTS IN TAIL CONE INOPERATIVE. REPLACED AFT POWER SUPPLY, OPERATIONAL CHECK NORMAL.SDR TWAA0004903Floor Support · crackedDURING OP 16 MAINT CHECK, THE SUPPORT RIBS FOR FLOOR PANEL NUMBER 40 WERE CRACKED. MADE NEW PANEL PER STA SSRM 53-00-104 PAGE 201.SDR MWEA00180Slide · dislodgedFOUND FORWARD GALLEY SERVICE DOOR EMERGENCY EVACUATION SLIDE DISLODGED FROM ITS COVER. MAINTENANCE REINSTALLED EMERGENCY EVACUATION SLIDE.SDR AT0000225Longeron · damagedFOUND AND REMOVED TEMPORARY REPAIR AT BS 227L - 17L. FABRICATED AND INSTALLED PERMANENT REPAIR IAW TIMCO REO L00099.SDR AT0000150Strap · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON NUTPLATE STRAP UPPER SPAR CAP WS 445 - 430. AFTER REMOVAL OF CORROSION FOUND MATERIAL OUT OF LIMITS. CORRECTIVE ACTION: FABRICATED AND INSTALLED NEW STRAP IAW DC9 SRM 51-30-02, 51SDR AT0000125Connector · disconnectedNO RIGHT MAIN LANDING GEAR GREEN LIGHT FOR THE LANDING GEAR DOWN INDICATION. CORRECTIVE ACTION: CORRECTED OPEN WIRE AT RT GEAR DOWN LIMIT CONNECTOR (P1-129).SDR GTIA000142Light · inoperativeACY - FLT 812 - ONE FORWARD EMERGENCY TRACK LIGHT INOPERATIVE. DEFERRED TO DMI 81030-1 MEL 33-24, CAT C, PLACARDS INSTALLED. REPLACED FORWARD EMERGENCY TRACK LIGHT SOCKET. OPS CHECK GOOD IAW MM 33-53-0. THIS CLEARS DMI 81030-1. PLACARD REMOVED. (M)SDR AT0000148Web · corrodedFOUND FUSELAGE BS 980 WEB WAS CORRODED. FORMED 1 REPAIR DOUBLER WEB AND INSTALLED IAW DC9 SRM 53-11-4 FIGURE 3, 51-10-3.SDR AT0000145Skin · lightning strikeFOUND LIGHTNING STRIKE AT LONGERON 3L BS 917 OUT OF LIMITS. CUTOUT LIGHTNING STRIKE, FABRICATED AND INSTALLED REPAIR. IAW DC9 SRM 53-04 FIGURE 38, 51-10-3, 51-30-2.SDR AT0000127Light · dislodgedEMERGENCY PATH LIGHTING IN BUSINESS CLASS IS OUT OF TRACK. CORRECTIVE ACTION: RESECURED LIGHT.SDR AT0000126Actuator · failedPRIMARY HORIZONTAL TRIM ACTUATOR MOTOR INOPERATIVE. CORRECTIVE ACTION: R/R PRIMARY TRIM MOTOR IAW MM 27-40.SDR MWEA00177Stop · crackedVENTRAL DOOR CORNER UPPER RIGHT STOP IS CRACKED. MAINTENANCE REMOVED AND REPLACED DOOR STOP.SDR AT0000144Pan · corrodedFOUND G1 GALLEY OUTBOARD LOWER COMPARTMENT AT WATER DRAIN PAN CORRODED. FABRICATED PANEL AND REINSTALLED IAW DC9 SRM 51-10-4, 51-30-8, 51-10-3, 55-05.SDR AT0000151Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND GALLEY LOWER COMPARTMENT PANEL CORRODED. AFTER BLENDING MATERIAL FOUND TO BE OUT OF LIMITS. CORRECTIVE ACTION: FABRICATED AND INSTALLED GALLEY PANEL IAW DC9 SRM 53-05, 51-10-03, 51-10-04, AND SDR TWAA0004801Frame · misrepairedDURING OP 16 MAINT CHECK, THE LT 980 FRAME HAD A TEMPORARY REPAIR BETWEEN LONGERON 18 AND 16. REMOVED DAMAGED FRAME SECTION AND INSTALLED NEW SECTION PER SRM 53-03 FIG 32. REPAIR WORKED IN CONJUCTION WITH MO72J14 PHASE G CARD 0003 OF 7.SDR TWAA0004813Spar · crackedDURING OP 16 MAINT CHECK, ON THE RT WING, HAD CRACK INDICATION ON WING SPAR CAP AT I/B FLAP HINGE FITTING, STA XRS164, LOWER I/B BOLT HOLE EXTENDED INTO LOWER RADIUS. REPLACED LOWER REAR SPAR CAP PER DOUGLAS DRAWING JO60165 AND MCD-AD-35.SDR AT0000147Doubler · chafedFOUND APU DOOR CRACK BLENDED OUT OF LIMITS. FABRICATED REPAIR DOUBLER AND INSTALLED ON APU DOOR IAW DC9 SRM 52-10 FIGURE 2.SDR AT0000143Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR SUPPORT CORRODED ON BOTH SIDES AT BS 200, RBL 44 - 56. CORRECTIVE ACTION: FABRICATED AND INSTALLED NEW SUPPORT IAW DC SRM53-01 FIG 1, 51-10-02, AND 51-10-03.SDR GTIA000137Wire · exposedDTW - EMERGENCY TRACK LIGHTING HAS WIRES EXPOSED THROUGHOUT CABIN. REPOSITIONED EMERGENCY FLOOR TRACK WIRES. OPS CHECK GOOD IAW DC-9 MM 33-50-00. (M)SDR AT0000122Light · inoperativeFOUND LEFT TAILCONE EMERGENCY FLOOD LIGHT INOPERATIVE. CORRECTIVE ACTION: RELAMPED IAW MM 33-50.SDR MWEA00156Clip · corrodedMODERATE CORROSION ON FORMER AT STATION 691 AT RIGHT SIDE OF KEEL BEAM. REMOVED AND INSTALLED NEW CLIP.SDR MWEA00155Door Frame · corrodedCORROSION ON ELECTRIC AND ELECTRONICAL CEILING AT STATION 200 AT RIGHT OUTBOARD CORNER. FABRICATED AND INSTALLED NEW CUSP SECTION, JAMB, AND REPAIR SPLICES.SDR MWEA00154Rib · crackedRIGHT ELEVATOR MOST INBOARD RIB ANGLE LOWER FORWARD SIDE CHAFED AND CRACKED. FABRICATED AND INSTALLED NEW RIB.SDR MWEA00153Floor Support · gougedSUB FLOOR GOUGED 3 INCHES AFT OF STATION 180 NEAR RIVET HOLES IN LINE OF NR 4 SEAT TRACK. FABRICATED AND INSTALLED SECTION OF FLOORBOARD.SDR MWEA00152Seat Track · corrodedFLOOR SUPPORT BETWEEN CENTER LINE, AND NR 3 SEAT TRACK AT STATION 200 HAS MODERATE CORROSION. FABRICATED AND INSTALLED NEW FLOOR SUPPORT.SDR MWEA00151Floor Support · crackedSUB FLOOR CRACKED RIGHT SIDE 7.5 INCHES OUTBOARD OF NR 3 SEAT TRACK AND 2.5 INCHES FORWARD OF STATION 218. FABRICATED AND INSTALLED SUB FLOOR SECTION.SDR MWEA00150Floorbeam · corrodedREMOVED FLOORBEAM RIGHT BUTTLINE 20-40 AT STATION 200 AND FOUND TO BE CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOORBEAM.SDR MWEA00149Vane · chafedLEFT FLAP INBOARD FIXED VANE OUTBOARD CLOSEOUT PANEL CHAFED ALONG UPPER AFT EDGE. FABRICATED AND INSTALLED NEW DOUBLER.SDR MWEA00148Angle · corrodedLIGHT CORROSION ON ANGLE AT STATION 691 ATTACHED TO RIGHT SIDE OF KEEL WEB. FABRICATED AND INSTALLED ANGLE.SDR MWEA00147Angle · corrodedSERVICE DOOR JAMB AT THE CUSP LINE HAS AN ANGLE THAT IS CORRODED HEAVY AT STATION 200 STATION 207. FABRICATED AND INSTALLED NEW ANGLE.SDR MWEA00146Keelbeam · crackedSTATION 691 AT LONGERON 30 HAS A CRACK AT FOURTH FASTENER, CRACK IS ON THE WEB KEEL WEB. FABRICATED AND INSTALLED REPAIR DOUBLER.SDR MWEA00145Frame · crackedFRAME 617 LONGERON 24 RIGHT THRU 30 CRACK ON OUTBOARD END. FABRICATED AND INSTALLED NEW DOUBLER.SDR MWEA00143Floorbeam · crackedSUB FLOOR CRACKED, 6 INCHES TO THE LEFT OF CENTER AT STATION 200. FABRICATED AND INSTALLED DOUBLER.SDR MWEA00142Longeron · corrodedLIGHT CORROSION AROUND FASTENERS IN LONGERON 28 RIGHT FROM STATION 646 TO 670. FABRICATED AND INSTALLED NEW LONGERON.SDR MWEA00141Floorboard · corrodedFORWARD EDGE OF FLOORBOARD AT STATION 237 BETWEEN NR 3 AND NR 4 SEAT TRACKS ARE MODERATLY CORRODED. FABRICATED AND INSTALLED FLOORBOARD.SDR MWEA00140Seat Track · corrodedNR 4 SEAT TRACK AND UNDERSIDE OF UPPER LEG HAS MODERATE CORROSION ON IT FROM STATION 200 TO STATION 237. FABRICATED AND INSTALLED SEAT TRACK AND SPLICES.SDR MWEA00166Web · crackedLEFT ELEVATOR CRACK ON FITTING, INBOARD PART OF LEADING EDGE ON BOTTOM SIDE. FABRICATED AND INSTALLED NEW RIB.SDR MWEA00165Seat Track · corrodedNR 3 SEAT TRACK AND UNDERSIDE OF UPPER LEG HAS MODERATE CORROSION ON IT FROM STATION 200 TO STATION 237. FABRICATED AND INSTALLED SEAT TRACK.SDR MWEA00164Skin · corrodedMODERATE CORROSION ON LOWER FUSELAGE SKIN LEFT OF LONGERON 30 AT STATION 579. FABRICATED AND INSTALLED FILLER AND DOUBLER.SDR MWEA00163Floor Support · crackedSUB FLOOR CRACKED OUT AROUND RIVET HOLE AT STATION 200, 5.5 INCHES OUTBOARD OF NR 3 SEAT TRACK. FABRICATED AND INSTALLED FILLER AND DOUBLER.SDR MWEA00162Beam · crackedGALLEY SERVICE DOOR LOWER BEAM FORWARD END IS CRACKED IN OUTER RADIUS. FABRICATED AND INSTALLED NEW FITTING.
Back to Douglas DC-9-32