SDR SIMA20140323009Warning Message · false activationAFTER TAKEOFF, RECEIVED A BRAKE DEGRADE MOMENTARILY ON EICAS & LT INBD BRAKE INDICATOR VANISHED AND BRAKE OVERHEAT SEVERAL MINUTES LATER. COMPLIED WITH AOM VOL I PROCEDURE FOR OVERHEAT & RETURN TO DEPARTURE. INBD INDICATOR NEVER RETURNED, ALL OTHER BRAKE INSDR SIMA20140323012Potentiometer · out of adjustABORTED TAKEOFF IAW FULL LT RUDDER TO MAINTAIN STRAIGHT CENTERLINE DIRECTIONAL CONTROL. LOW SPEED ABORT, TOOK DELIBERATE LT CORRECTION OF TILLER TO MAINTAIN STRAIGHT TAXI. WHILE WAITING FOR TOW WE COULD HEAR STEERING CLICKING 5 TIMES, NO EICAS MSG AT ALL DURSDR SIMA20140323007Smoke Detector · false activationAT CRUISE FLT 370, WE RECEIVED A LAVATORY SMOKE EICAS MSG. AOM PROCEDURES FOLLOWED CB'S E11 & E12 PULLED. SMOKE MSG WENT AWAY, WE CONTINUED TO MONITOR LAVATORY. INSPECTED LAVATORY FOR EVIDENCE OF SMOKE OR DAMAGE, NO DEFECTS NOTED. DEFERRED IAW MEL 26-2. SDR SIMA20140323001Fitting · crackedDURING HMBV INSPECTION FOUND CLIP FROM FIRST OFFICER`S DV WINDOW CUT OUT TO FRAME 10 ON THE LOWER SIDE OF CUT OUT HAS A 2" CRACK. R & R CLIP IAW SRM 51-40-02.SDR SIMA20140323008Doubler · damagedRIGHT SIDE OF FRAME 64 HAS DAMAGE ON A PREVIOUS REPAIR DOUBLER. COMPLIED WITH EO EM-53MR-1972.SDR CHQA20140322107Skin · gougedDURING INSPECTION, A GOUGE WAS FOUND ON THE RT NR 2 WING LE UPPER NOSE SKIN. THE RT NR 2 WING LE UPPER NOSE SKIN WAS REPAIRED IAW SRM 57-40-00.SDR CHQA20140322105Doubler · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LT OMEGA BEAM DOUBLER AT Y=-479.0 AT FRAME 20. THE BEAM WAS REPAIRED IAW SRM 53-00-10.SDR CHQA20140322104Fitting · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE SHEAR CLIP AT FRAME 24 & STRINGERS 15R - 16R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR CHQA20140322103Stringer · chafedDURING INSPECTION, STRINGER 21 WAS FOUND TO BE CHAFED BETWEEN FRAME 20 & 21. THE STRINGER WAS REPAIRED IAW ETD 2014-145-025850-A.SDR SIMA20140322001Battery · dischargedLT & RT OVERWING EXTERIOR EMERGENCY LIGHTS INOPERATIVE. R & R NR 4 EPSU BATTERY & CHARGER ASSEMBLY IAW AMM 33-50-04, OPERATIONS CHECKED GOOD IAW AE WC 33-700-17.SDR SIMA20140322002Light · inoperativeRT AFT EXTERNAL EMERGENCY EXIT LIGHT INOPERATIVE. R & R LAMP IN RT AFT EXTERNAL EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-10, OPERATIONS CHECKED GOOD.SDR ASOA20140322068Skin · damagedTWO DENTS AND A CREASE WERE FOUND ON THE LT FUSELAGE BETWEEN FRAME 20 AND 22. MAINTENANCE RECONTOURED DENTS FROM FRAME 20 THRU FRAME 22. INSTALL A FILLER AND DOUBLER ON THE CREASE AREA. PERFORMED A NDT AND NO CRACKS WERE NOTED. WORK WAS DONE IAW ETD 2014-1SDR ASOA20140321041Inverter · inoperativeDURING MX INSPECTION, THE FLOOR EMERGENCY LIGHT STRIPS WERE FOUND INOPERATIVE. MX R & R THE NR 2 EMERGENCY LIGHT SYS INVERTER WITH OPS CHECK GOOD. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA201403210001Control Panel · inoperativeEMERGENCY LIGHT TEST SWITCH INOPERATIVE AND F/A CONTROL PANEL. MAINTENANCE INSPECTED AND REPLACED CONTROL PANEL, OPS CHECKED GOOD.SDR SIMA20140321004Charger · inoperativeFOUND LT & RT EXTERIOR OVERWING EMERGENCY LIGHT NOT ON. R & R NR 4 EMERGENCY LIGHT BATTERY CHARGER & BATTERY PACK IAW AMM 33-50-04. R & R RT EXTERIOR OVERWING EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-10, OPERATIONS CHECKED GOOD.SDR SIMA20140321001Frame · corrodedDURING HMBV INSPECTION, QA FOUND ON FRAME 65, TWO CORRODED NUTPLATE HOLES JUST ABOVE LT FLOOR SUPPORT. ACFT WAS REMOVED FROM SERVICE FOR HMBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER HMBV INSPECTION. PERFORMED PERMANENT REPAIR ON TWO CORRODED NUTPLATE HSDR SIMA20140320004Light · inoperativeEXIT EMERGENCY LIGHT AT ROW 3 INOPERATIVE. R & R EXIT EMERGENCY LIGHT AT ROW 3, OPERATIONS CHECKED BAD IAW AMM 33-50-13.SDR SIMA20140320003Charger · inoperativeEMERGENCY LIGHT IN MIDDLE CEILING LIGHT INOPERATIVE. R & R BATTERY & CHARGER ASSEMBLY IAW AMM 33-50-04, OPERATIONS CHECKED GOOD.SDR SIMA20140320002Battery · dischargedEMERGENCY LIGHT AT FWD WING INOPERATIVE. R & R BATTERY & CHARGER ASSEMBLY IAW AMM 33-50-04, OPERATIONS CHECKED GOOD.SDR SIMA20140319008Proximity Switch · failedUPON LG RETRACTION DEPARTING DFW HAD LG AIR & GND FAIL MSG ON EICAS. R & R LT MLG WOW 1 & WOW 2 PROX SWITCHES & RT MLG WOW 1 PROX SWITCH IAW AMM 32-63-01. FUNCTION CHECK GOOD IAW AMM 32-63-05.SDR SIMA20140319007Bracket · crackedCAPTAIN'S FLASHLIGHT BRACKET CRACKED. R & R CAPTAIN'S FLASHLIGHT IAW AMM 33-50-16, OPERATIONS CHECKED GOOD.SDR SIMA20140319005Holder · defectiveR & R FLASHLIGHT HOLDER OVER FLIGHT ATTENDANT'S SEAT IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20140319004Yoke · crackedRT ENG PYLON FWD YOKE CRACKED AT LOWER ENG MOUNT. R & R RT LOWER FWD YOKE IAW EO EM-54MR-386.SDR SIMA20140319003Light · inoperativeEMERGENCY LIGHT FWD OF WING INOPERATIVE. R & R FWD EMERGENCY LIGHT IAW AMM 33-50-10, LIGHT OPERATIONS CHECKED GOOD.SDR SIMA20140318007Support Frame · crackedDURING HMBV INSPECTION FOUND THE NLG BAY AFT UPLOCK BOX SUPPORT FRAME IS CRACKED ON THE LT SIDE. R & R NLG BAY, AFT UPLOCK BOX SUPPORT FRAME IAW SRM 51-40-02.SDR SIMA20140318008Firewall · crackedDURING HMBV INSPECTION FOUND THE APU FIREWALL CRACKED AT THE TOP RT MOUNTING POINT & ABOVE THE TOP RIVET ON THE RT SIDE RIVET ROW. COMPLETED FABRICATION & INSTALLED NEW DOUBLER AT TOP RT MOUNTING POINT IAW EO EM-53AD-1883 & ETN EM-53-244. COMPLETED REPAIR OFSDR SIMA20140318009Attach Angle · crackedDURING HMBV INSPECTION FOUND RT WING TO FUSELAGE FAIRING LOWER ATTACH ANGLE IS CRACKED BETWEEN FRAMES 47 - 48. CRACK APPROXIMATELY 1 INCH LONG. INSTALLED NEW ANGLE IAW SRM CH 51-40-02.SDR SIMA20140318010Attach Angle · crackedDURING HMBV INSPECTION FOUND LT WING TO FUSELAGE FAIRING LOWER ATTACH ANGLE IS CRACKED BETWEEN FRAMES 45 - 46 & AT FRAME 46. THIS REPAIR IS LOCATED ON THE SAME ANGLE & IS FARTHER AFT THAN THE CRACK AT FRAME 45 - 46. IAW NRWC E374048 FOR THE AFT SECTION OF THSDR SIMA20140318001Flashlight · defectiveFLIGHT ATTENDANT`S FLASHLIGHT WILL NOT CHARGE UNLESS ITS PUSHED & HELD IN. R & R FLIGHT ATTENDANT`S FLASHLIGHT ASSEMBLY IAW AMM 33-51-01, OPERATIONS CHECKED GOOD.SDR SIMA20140318005Power Supply · inoperativeBOTH LT & RT WING UPPER EMERGENCY LIGHTS ARE INOPERABLE. R & R NR 4 EMERGENCY BATTERY POWER SUPPLY IAW AMM 33-50-04. OPERATIONS CHECKED GOOD.SDR SIMA20140318006Pressure Switch · corrodedTAKEOFF CONFIG CHECK GETS YOU AURAL WARNING, BRAKES, EVEN THOUGH THE PARKING BRAKES ARE OFF WITH THE BRAKES ON LIGHT EXTINGUISHED. FOUND CONNECTOR CONNECTION TO PRESS SWITCH TO BE CORRODED, BRAKE. R & R PRESS SWITCH IAW AMM 32-44-07. CLEANED PLUG END IAW WMSDR SIMA20140318002Cover · crackedSIDE HINGED MAIN DOOR EMERGENCY LIGHT COVER CRACKED. R & R SIDE HINGED MAIN DOOR EMERGENCY LIGHT COVER. OPERATIONS CHECKED GOOD IAW AMM 25-23-04 STEPS 2J3E, 3I3G.SDR ASOA20140317027Display · failedCREW REPORTED F/O MFD WENT BLANK FOLLOWED BY ELECTRICAL BURNING ODOR. MAINTENANCE INSPECTED COCKPIT ELECTRICAL WIRING AND NO DEFECTS WERE FOUND. OPENSDR CHQA20140317087Proximity Switch · out of adjustCREW REPORTED THAT THEY RECEIVED AN ENG 2 THRUST REVERSER DISAGREE MSG DURING CLIMB OUT. THE CREW SHUT DOWN THE NR 2 ENG AS A PRECAUTION, DECLARED EMERGENCY & RETURNED TO FIELD. THE ACFT LANDED WITHOUT FURTHER INCIDENT. MX DEFERRED ENG 2 THRUST REVERSER. TSDR SIMA20140317002Holder · brokenCAPTAIN'S FLASHLIGHT HOLDER BROKEN. R & R CAPTAIN'S FLASHLIGHT HOLDER IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20140317004Power Supply · inoperativeFOLLOWING EMERGENCY LIGHT INOPERATIVE. BOTH OVERWING, AFT FLOOR & AFT 2 CEILING LIGHTS. R & R NR 4 BATTERY POWER SUPPLY IAW AMM-33-50-04. OPERATIONS CHECKED GOOD.SDR SIMA20140317001Roller · dirtyPASSENGER DOOR DIFFICULT TO OPEN. CLEANED & LUBRICATED MAIN DOOR FRAME ROLLERS IAW EMB MM 53-21-02. OPERATIONS CHECK OF DOOR OK IAW MM 56-10-01.SDR ASOA20140317030Fitting · crackedDURING C-CHECK. NR 2 ENGINE FWD LOWER YOKE FITTING CRACKED. R & R NR 2 ENGINE FWD LOWER ENGINE YOKE FITTING IAW EC 5450-01073. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA20140316086Battery · dischargedDURING INSPECTION THE NR 4 EMERGENCY LIGHT BATTERY WAS REPORTED TO BE INOPERATIVE. MAINTENANCE REPLACED THE NR 4 EMERGENCY LIGHT BATTERY. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20140316004Structure · damagedPRESS LEAK, RUSHING AIR, AT TOP WINDOW AREA ON CAPTAIN`S SIDE. REPAIRED DAMAGE IN ACCORDANCE WITH AEA EO EM-5300-2232 AND ERS-EM-5300-326.SDR SIMA20140316005Panel · crackedPILOT SIDE CEILING PANEL CRACKED. REPAIRED CRACKS IAW ETN GN-20-023R3.SDR RAIA201403160001Bulb · inoperativeCEILING EMERGENCY EXIT LIGHT AT ROW 17 INOPERATIVE. MAINTENANCE REPLACED BULB AND OPS CHECKED GOOD.SDR SIMA20140316001Connector · missingNR 6 EMERGENCY LIGHT STRIP WIRE CONNECTORS MISSING. REPLACED CONNECTORS ON THE EMERGENCY LIGHT STRIP NR 6 IAW SWPM 20-00-03 & 20-50-01.SDR SIMA20140316002Connector · unsecureEMERGENCY LIGHT INOPERATIVE AT GALLEY CABIN PARTITION WALL. SECURED ELEC CONNECTOR FOR EXIT IDENTIFIER SIGN AT GALLEY, CABIN PARTITION IAW AMM 33-50-13 STEP I 3 B. OPERATIONS CHECKED GOOD.SDR CHQA20140315085Battery · dischargedDURING INSPECTION THE NR 4 EMERGENCY LIGHT BATTERY WAS REPORTED TO BE INOPERATIVE. MX REPLACED THE NR 4 EMERGENCY LIGHT BATTERY. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20140315002Light · inoperativeLT & RT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R LIGHT BULBS IAW AMM 33-50-10.SDR SIMA20140315003Battery · dischargedFWD LOWER RT EXTERIOR EMERGENCY LIGHT & SECOND CEILING CABIN EMERGENCY LIGHT INOPERATIVE. R & R NR 2 EMERGENCY LIGHTING BATTERY, POWER SUPPLY & OPERATIONS CHECKED GOOD IAW AMM 33-50-04.SDR SIMA20140314011Window Frame · corrodedCOPILOTS WINDSHIELD HAS CORROSION ON LOWER INBD SIDE OF THE OUTER FRAME. BLENDED AREAS FOR CORROSION ON COPILOTS WINDSHIELD LOWER INBD SIDE OF THE OUTER FRAME ACCEPTED IAW ERS-EM-5600-024.SDR SIMA20140314010Window Frame · corrodedPILOTS WINDSHIELD HAS CORROSION ON LOWER INBD SIDE OF THE OUTER FRAME. BLENDED AREAS FOR CORROSION ON PILOTS WINDSHIELD LOWER INBD SIDE OF OUTER FRAME ACCEPTED IAW ERS-EM-5600-023.SDR SIMA20140314013Shear Tie · crackedCARGO BAY FRAME 67 SHEAR TIE CRACKED BETWEEN STRINGER 7 & 8 LEFT. REPAIRED IAW SRM 53-31-04.
Back to Embraer EMB-145LR