SDR GR4D2014F00004Attach Fitting · corrodedLT FLAP TRACK UPPER ATTACH FITTING CORRODED BEYOND REPAIR, REF W/O 2530.19.5.SDR GR4D2013F00166Attach Fitting · corrodedLEFT FLAP A TRACK UPPER ATTACH FITTING CORRODED BEYOND REPAIR.SDR GR4D2014F00003Attach Fitting · corrodedRT FLAP UPPER ATTACH FITTING CORRODED BEYOUND REPAIR, W/O 2530.19.8.SDR 2013FA0000547Flap Track · corrodedRIGHT "C" TRACK UPPER SUPPORT FITTING CORRODED BEYOUN REPAIR REF. W/O 2530.19.11.SDR 2014F00002Plate · corrodedRT BELLCRANK PLATE CORRODED BEYOND REPAIR, REPLACED PLATE.SDR 2014F00001Flap Track · corrodedLT FLAP "C" TRACK CORRODED BEYOND REPAIR.SDR DXTA2013091005497Brake · malfunctionedDURING LANDING, LT PEDAL BRAKE PRESSURE DROPPED AROUND 95KTS, LT BRAKE GRABS AND LT BRAKE TEMP ROSE TO 200 DEGREES C, WHILE THE RT SIDE REMAINS AROUND 80 DEGREES C. CLEANED LEFT BRAKES OF DEBRIS. BLED BRAKES IAW CMP 324265. PERFORMED HYDROMECHANICAL ANALOG SDR W9FA2013FA0000467Structure · corrodedWHILE PERFORMING AN INSPECTION, DISCOVERED CORROSION OF HARDWARE AND PITTING IN THE BORE OF THE ATTACH POINT ON THE RT WINGLET. BEYOND THE MFG LIMITS. CORROSION WAS DUE MOISTURE INTRUSION THROUGH THE SEALANT COVERING THE ATTACH POINTS.SDR Y9PA201308090001Apu · inoperativeWHILE PARKED AT THE FBO, THE CREW NOTICED A SURGE IN THE APU, THE ACFT LOST ELECTRICAL POWER FOR A MOMENT, THE APU RECOVERED, ELECTRICAL POWER RETURNED, THEN THE CREW NOTICED THE OIL ODOR AND SMOKE IN COCKPIT. THE CREW THEN SHUTDOWN THE APU FOR FURTHER TROUBLESDR BTVR201308080001Bulkhead · damagedDURING A ROUTINE SCHEDULED INSPECTION OF THE BAGGAGE COMPARTMENT, NOTED A LARGE SECTION OF LOWER COMPOSITE SECTION OF REAR PRESSURE BULKHEAD WAS DELAMINATED AND CRACKED.SDR W9FA201310240001Line · cloggedTHE ENGINE WAS REMOVED FOR EXCESSIVE OIL LEAKAGE. DURING THE REPAIR INVESTIGATION THE PN JR27664, LPT SCAVENGE TUBE WAS FOUND COMPLETELY BLOCKED WITH CARBONIZED OIL, AND CAUSING EXCESSIVE OIL LEAKAGE FROM THE ENGINE. THE PN JR27664 TUBE, AS WELL AS PN JR29486SDR BKER2013080600919Seal · failedDEPARTED AIRPORT. CREW DEVERTED WITH POSSIBLE BLOWN DOOR AIR SEAL.SDR GR4D201306250014Attach Fitting · corrodedLEFT FLAP TRACK BORE ON UPPER SUPPORT FITTING CORRODED. R & R FITTING WITH NEW.SDR E0X2013F00000Iru · failedACFT WAS ENROUTE. CREW DETECTED AN ODOR OF SOMETHING ELECTRICAL BURNING. ELECTED TO DIVERT THE FLIGHT WITHOUT INCIDENT. MX DETERMINED THAT THE NR 1 IRU FAILED AND WAS THE SOURCE OF THE ODOR. UNIT WAS REPLACED AND THE ACFT WAS RETURNED TO SERVICE.SDR WWQA20130606001Fitting · crackedCREW REPORT THE MAIN ENTRY DOOR WAS NOT CLOSING COMPLETELY. MX FOUND DURING TROUBLESHOOTING THE PROBLEM A CRACK IN A FITTING AFT OF FRAME 169 WHERE THE MAIN ENTRY DOOR ACTUATOR ATTACHES.SDR 2013F00126Rod End · damagedR & R FLIGHT SPOILER PUSHROD END ASSY IAW CB 203. PART DETERMINED TO NO LONGER BE SERVICABLE, PN 1159CM20263.SDR 2013F00125Fitting · corrodedWHILE REMOVING BOLT FROM RT FLAP TRACK FITTING, FOUND THE UPPER FITTING TO HAVE EXTREME CORROSION ON INBD FACE OF FITTING.SDR CA130528007Drive Shaft · cracked(CAN) FOUND A CRACK ON AN LPC DRIVE SHAFT REAR SPLINE END FACE. (SHAFT SERAL NUMBER 1680NNB) TAY 16009 IS HERE FOR A 2ND MID LIFE. THE CRACK INDICATION WAS CONFIRMED BY A SECOND FPI CHECK. THIS SHAFT ALSO HAS FRETTAGE ON THE FRONT SPLINESSDR CWQA04252013Valve · out of adjustON LANDING, RIGHT BRAKE LOCKED. MAINTENANCE EVALUATION REVEALED RIGHT HAND BRAKE ANTI-ROTATION PRESSURE REDUCING VALVE WAS OUT OF ADJUSTMENT. ADJUSTED AND ANTI-ROTATION VALVE OPS TEST CHECKED GOOD.SDR COZA20130311025Structure · corrodedDURING LT AND RT WINGLET ATTACH HOLE 144 MONTH INSPECTIONS, CORROSION WAS FOUND IN THE HOLES. USING MFG ENGINEERING DATA, HOLES WERE REPAIRED BY OVERSIZING AND LOCAL BLENDING. OVERSIZED FASTENERS WERE INSTALLED AS REQUIRED.SDR SPOA20130224001O-Ring · damagedCREW REPORT: "COMBINED HYDRAULIC SYSTEM LOSS OF FLUID WHILE AT CRUISE FLIGHT". INSPECTION REVEALED LEAK AT FLIGHT SHUTOFF VALVE "TEE" FITTING. O-RING REPLACED IN FITTING RESOLVING LEAK. AIRCRAFT RETURNED TO SERVICE WITH NO FURTHER PROBLEMS.SDR DXTA2013021905292Connector · contaminatedRIGHT MLG GREEN INDICATOR LIGHT ILLUMINATED IN FLIGHT AT FL410, 30 MINUTES AFTER TAKEOFF. NO SIGNIFICANT WEATHER AT ALTITUDE. COCKPIT LIGHTS WERE TESTED BUT GREEN LIGHT REMAINED ILLUMINATED. AFTER 45 MINUTES AT CRUISE, COCKPIT LIGHTS WERE ADJUSTED FOR NIGHT FLSDR DXTA2012123105222Control Unit · unserviceableUNABLE TO MODULATE BRAKES. ONCE BRAKES ARE WARM THERE IS NO FEEL. THEY GO FROM NOTHING TO FULL GRAB. BOTH LT AND RT BRAKES DO THE SAME THING. BOTH CAPTAIN AND COPILOTS PEDALS ARE THE SAME. NO BRAKE FEEL FROM THE PEDALS. DOES NOT MATTER HOW SLOW YOU APPLY PEDASDR DXTA2013010405231Augment Valve · unserviceableWHEN BRAKE PRESSURE IS APPLIED THERE IS NO RESPONSE FOR THE FIRST 2-3 INCHES OF BRAKE PEDAL MOVEMENT THEN THE BRAKES GRAB HARD ENOUGH TO THROW PAX AND CREW FORWARD. BRAKES TEMPS LESS THAN 100 DEGREES. TROUBLESHOT, WHEN BRAKE PRESSURE IS APPLIED THERE IS NO RESDR DXTA2012F00227Trunnion · corrodedRIGHT SPONSON RIB TRUNNION FORWARD AND AFT LUG CORRODED, REF W/O SC2198.15.13 AND 15.20. REF DWG NR SE45732901, REV G AND SE05732901, REV F.SDR 2012FA0000759Trunnion · corrodedLEFT SPONSON RIB TRUNNION HAS CORROSION IN FORWARD AND AFT LUG, REF W/O SC2198.15.12 AND 15.17. REF DWG NR SE45732901, REV G AND SE05732901, REV F.SDR DXTA2012110905178Reservoir · contaminatedON LANDING, DURING BRAKING, LT BRAKE PRESSURE IS APPLIED AND BRAKE GRABS EXCESSIVELY AFTER SHORT DELAY. PERFORMED INSPECTION OF TIRES, BRAKES, LANDING GEAR AND BRAKE PEDALS. NO DISCREPANCIES FOUND. PERFORMED L/H, R/H BRAKE BLEED PROCEDURE IAW GIV CMP 324265 ASDR WWQA201211080001Dadc · deactivatedDURING DESCENT, AT ABOUT 26000 FT, DADC 1 WENT OFF LINE, CAUSING LOSS OF VARIOUS SYSTEMS, AFTER EVALUATING THE SYSTEMS LOSS AND COMPAIRING ALTIMETERS, IT WAS DETERMINED DADC 1 HAD GONE OFF LINE, DADC 2 SELECTED AND SYSTEM RESET. ABOUT 30 SECONDS LATER DADC 2SDR COZA20121108018Bearing · migratedDURING A LANDING GEAR OPERATIONAL CHECK, FOUND THE RIGHT MAIN LANDING GEAR DOOR AFT HINGE BEARING MIGRATED OUT OF HINGE FITTING. BEARING WAS NOT SWAGED IN HINGE. SWAGED NEW BEARING P/N MS14101-6 INTO HINGE FITTING. OPERATIONAL CHECK NORMAL.SDR DXTA2012110505166Coalescer Bag · odorDURING CLIMB, NOTICED A VERY STRONG EXHAUST ODOR THROUGHOUT THE ENTIRE CABIN. THE ODOR TEMPORARILY FADED BUT REAPPEARED ABOUT 10 MINUTES INTO THE FLIGHT AND REMAINED. DONNED MASKS AND DROPPED PAX MASKS AND RETURNED TO DEPARTURE. AFTER LANDING THE ODOR WAS SSDR VPQ2012F00000Wire · misinstalledAFTER RECEIVING FLIGHT DATA RECORDER ANALYSIS READ OUT, FOUND THE THRUST REVERSERS WERE RECORDED AS UNLOCKED DURING CRUISE AND TAKEOFF PHASE OF FLIGHT. RESEARCHED CUSTOMER`S OUTFITTER DWG AND FOUND FDR SYSTEM WAS PROVISIONED IAW MFG DWG SC4142001001, REV B, DSDR DXTA2012101505147Valve · inoperativeRT BRAKE GRABS. BRAKE PRESSURE JUMPS FROM 300 TO 500 PSI WHEN SLOWLY APPLYING THE BRAKES. OPERATED BRAKES WITH PRESSURE GAUGE INSTALLED ON RIGHT BRAKE. NOTED THAT DURING LIGHT BRAKE APPLICATION ON RIGHT SIDE (UNDER 500PSI) WHEN PRESSURE PEAKS PAST 200 PSI THSDR 2012F00172Winglet · corrodedRIGHT WINGLET CORRODED IN ATTACH BORE, REF W/O 2142.23.3-23.6 FOR REPAIR.SDR DXTA2012F00199Trunnion · corrodedRT SPONSON RIB TRUNNION FORWARD AND AFT LUG CORRODED, REPAIRED.SDR 2012F00195Trunnion · corrodedTRUNNION FORWARD AND AFT LUG CORRODED, REPAIREDSDR 2012FA0000651Rib · corrodedLEFT SPONSON RIB TRUNNION HAS CORROSION IN FORWARD AND AFT LUG, REFERENCE W/O 2129.21.28 AND 21.28.SDR 2012F00203Structure · corrodedLT WINGLET HAS CORROSION IN VERTICAL AND HORIZONTAL BORE. REPAIRED.SDR DXTA2012F00202Structure · corrodedCORROSION ON RT WINGLET ATTACH BORE, REPAIRED.SDR DXTA2012F00201Flap Track · corrodedRIGHT "B" FLAP TRACK CORRODED, REPAIREDSDR 2012FA0000648Flap Track · corrodedRIGHT "C" FLAP TRACK CORRODED, R & R IAW BP1159W40119.SDR 2012FA0000731Transducer · defectiveTHE CABIN PRESSURE TRANSDUCER WAS FOUND DEFECTIVE.SDR G1FR20120918001Hydraulic Line · misinstalledDURING THE RT MLG INSTALLATION AFTER O/H, THE HYDRAULIC LINES AT THE RT UPPER SWIVEL WERE CROSSED RESULTING IN TIRE FAILURE DURING LANDING ROLL. IT WAS FOUND THAT THE SPECIFIC MM PROCEDURES FOR THIS ACFT OMITTED OPS CHECKS WHICH WOULD HAVE DISCOVERED THE CROSSDR CA120905002Case · corroded(CAN) ENGINE RETURNED TO MFG FOR MIDLIFE INSPECTION. DURING ENGINE DISASSEMBLY AT OGV RING REMOVAL IT WAS NOTED THAT EXTERNAL INTERMEDIATE CASING WALL HAD EXCESSIVE CORROSION THAT HAS HOLED THE CASING WALL AND GENERATED A 10" CRACK. ENGINE HAS ALSO EXCESSIVE SDR CVGA20120812001O-Ring · failedAMBER CAS "CHECK HYD QUANTITY" ILLUMINATED IN-FLIGHT. VERIFIED LOSE OF COMBINED SYSTEM FLUID.SDR 9JLA201208281530Sensor · defectiveTHE CREW REPORTED THAT DURING LANDING AN ANTI-SKID FAIL AND BRAKED CAS MESSAGE ILLUMINATED. TROUBLESHOOTING IDENTIFIED THE NR 4 WHEEL SPEED SENSOR AS DEFECTIVE. SENSOR WAS REPLACED WITH AND O/H UNIT.SDR 2012FA0000541Flap Track · corrodedRT "B" FLAP TRACK CORRODED, REF BP SE45811104, REV B FOR REPAIR.SDR 2012FA0000538Structure · corrodedRIGHT WINGLET ATTACH HOLES CORRODED, REFERENCE BP SE5809903 REV. C FOR REPAIR.SDR 2012FA0000537Structure · corrodedLEFT WINGLET ATTACH HOLES CORRODED, REF BP SE35809903, REV C FOR REPAIR.SDR 2012FA0000535Flap Track · corrodedLT "B" FLAP TRACK CORRODED, REF BPSE45811104-3, REV B FOR REPAIR.SDR 2012FA0000533Trunnion · corrodedRIGHT SPONSON RIB TRUNION CORRODED, REPAIRED IAW BP SE45732901.
Back to Gulfstream Aerospace G-IV