Gulfstream Aerospace G-IV

Service difficulty reports · 842

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'GIV'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2012FA0000532Rib · corrodedLEFT SPONSON RIB CORRODED, REPAIRED IAW BP SE45732901 REV F.Aug 3, 2012 · N424QS · Gulstm GIV · Wing, Rib/BulkheadSDR 2012FA0000531Flap Track · corrodedRIGHT "C" FLAP TRACK CORRODED.Aug 3, 2012 · N424QS · Gulstm GIV · Trailing Edge FlapsSDR 2012FA0000530Track · corrodedLEFT "C" TRACK CORRODED.Aug 3, 2012 · N424QS · Gulstm GIV · Wing StructureSDR 2012FA0000529Track · corrodedRIGHT "B" TRACK CORRODED.Aug 3, 2012 · N424QS · Gulstm GIV · Wing StructureSDR DXTA2012080305075Brake Sys · failedBRAKES ARE VERY HARD AND UNRESPONSIVE. PEDALS DEPRESS ALMOST FULL TRAVEL WITH SOFT LIMITED BRAKING. AT THE VERY END OF TRAVEL, BRAKE PEDALS TAKE A LARGE AMOUNT OF EFFORT TO GET ANY SUBSTANTIAL EFFECT. WITH LOTS OF FORCE, BRAKES DO FINALLY ACHIEVE 3000PSI. NO OAug 2, 2012 · N401QS · Gulstm GIV · Landing Gear Brake SystemSDR DXTA2012072505058Indicator · false indicationCHECK, HYDRAULIC QUANTITY LIGHT FOR COMBINED SYSTEM. SYNOPTIC PAGE SHOWED FLUID LEVEL AT BOTTOM OF SCALE. FLUID LEVEL ON SYNOPTIC PAGE CAME BACK UP ON SHORT FINAL. PERFORMED LT ENGINE RUN AND FOUND THAT THE COMBINED RESERVOIR WAS INDICATING SLIGHTLY ABOVE TJul 24, 2012 · N498QS · Gulstm GIV · Hydraulic Indicating SystemSDR DXTA2012061805001Warning Light · illuminatedRIGHT THRUST REVERSER UNLOCK LIGHT ILLUMINATED IN FLIGHT. PERFORMED THRUST REVERSER RT OPS TEST. OPS TEST GOOD. NO DEFECTS NOTED. SERVICED FLIGHT HYD SYS TO FULL, REMOVED HYD PWR FROM ACFT. SYS, OPS CHECKS GOOD. REF G-IV CMP 783010 AND MM 78-00-0, WDJun 17, 2012 · N454QS · Gulstm GIV · Engine Thrust ReverserSDR GR4D20120530013Lug · corrodedRT AFT LUG ON SPONSON RIB HAS PITTING IN BORE.May 30, 2012 · N401QS · Gulstm GIV · Wing, Attach FittingsSDR DXTA2012050704969Control Box · inoperativeBRAKE PEDALS MUST BE FULLY DEPRESSED BEFORE ANY BRAKING ACTION IS FELT AND THEN THEY ARE VERY GRABBY. ALL BRAKE WEAR INDICATORS ARE GOOD. R & R ANTI-SKID CONTROL BOX AND INSTALLED A REPAIRED ANTI-SKID CONTROL BOX IAW G-IV CMP 324264. SUCCESSFUL OPS CHECK PERMay 5, 2012 · N472QS · Gulstm GIV · Landing Gear Brake SystemSDR K5SR2012050123537Wire · chafedWHILE PERFORMING ACFT SERVICE CHECK, NOTICED LARGE AMOUNT OF HYD FLUID AROUND APU COMPARTMENT. TROUBLESHOT WITH SYS PRESSURIZIED MOVED WIRE BUNDLE NEAR COMBINED HYD MANIFOLD AND WIRING SPARKED. FOUND 60HZ INVERTER WIRE HAD CHAFED THRU THE HYD PRESSURE LINE May 1, 2012 · Gulstm GIV · Electrical Power System WiringSDR CA120417020Connector · burned(CAN) BURNED WIRES WERE FOUND ON CONNECTOR PLUG 400P17 IN THE TAIL COMPARTMENT FUSE BS 603. THE WIRES IN THIS PLUG ARE FOR THE FIRE DETECTION LIGHT WARNING ON FIRE T-HANDLE. NO EVIDENCE OF FLUIDS IN THAT AREA, NO EVIDENCE OF RUBBING/CHAFING ON ANY OF THE SURApr 14, 2012 · Gulstm GIV · Fire Protection System WiringSDR CA120417018Cable · worn(CAN) DURING ELEVATOR AND RUDDER MAIN CABLE INSPECTION, ALL 4 CABLES WERE FOUND TO HAVE WEAR, BLENCHED CABLES, IN THE AREA WHERE THE CABLES RUN THROUGH GAMMA TUBES, BS 498-596, FURTHER INVESTIGATION FOUND THAT GAMMA TUBES WERE BOWING AND CAUSING CABLES TO RUB Apr 13, 2012 · Gulstm GIV · Flight Control SystemSDR CA120417017Drive Shaft · gouged(CAN) DURING A ROUTINE INSPECTION THE LT AND RT OTBD FLAP DRIVE SHAFTS WERE FOUND TO HAVE GOUGES LOCATED RT WERE THEY PASS THROUGH A LIGHTNING HOLE AT RBS 230 OF IT`S RESPECTIVE WING. DRIVE SHAFTS TO BE REPLACED. UNSURE OF CAUSE.Apr 13, 2012 · Gulstm GIV · Trailing Edge Flap Control SystemSDR GR4D20120321020Flap Track · corrodedFLAP TRACK CORRODED, ULTRA SONIC NDT INSPECTION COMPLIED WITH. AFTER ENGINEERING EVALUATION, REMAINING THICKNESS WAS UNACCEPTABLE. REF B/P SE05811901, REV D. REF CMP GIV MESSAGE 3575111 FOR INSPECTION.Mar 19, 2012 · N416QS · Gulstm GIV · Trailing Edge FlapsSDR W9FA201204180001Rib · corrodedLEFT SPONSON RIB REPLACED DUE TO CORROSION ON INSIDE DIAMETER OF LUGS. LUG BEARING REPLACEMENT WAS NOT POSSIBLE DUE TO PREVIOUS OVERSIZING; LUG BORE[S] WAS BEYOND LIMITS. RIGHT MAIN SPONSON RIB FORWARD BEARING LUG CORRODED - REAMED TO THE FORTH OVERSIZE. RIMar 12, 2012 · N1 · Gulstm GIV · SpoilersSDR CVGA20120301001Windshield · crackedPILOT'S WINDSHIELD CRACKED WHEN STARTING DESCENT.Mar 1, 2012 · N71BD · Gulstm GIV · Flight Compartment WindowsSDR DXTA2012022704888Engine · vibrationNR 1 ENGINE DISPLAYED HIGH VIBRATION, IE LP 2.25, IN FLIGHT. PRECAUTIONARY SHUTDOWN AND LANDING WITHOUT FURTHER INCIDENT. INSPECTED AIRCRAFT, NO DEFECTS NOTED.Feb 25, 2012 · N452QS · Gulstm GIV · Engine (Turbine/Turboprop)SDR CA120221008Compressor Wheel · cracked(CAN) STAGE 10 ROTOR DISC CRACKED AT DOVETAIL, 1 OFF. THE CRACK STEMS FROM DOVETAIL SLOT AND RUNS INTO END FACE. DISC, SN DETM19460 NO IMPACT DAMAGES ARE VISIBLE ON THE DISC.Feb 21, 2012 · Gulstm GIV · Turbine Engine Compressor SectionSDR GR4D20120125012Winglet · corrodedLT WINGLET CORRODED.Jan 25, 2012 · N428QS · Gulstm GIV · Wing Main, Frame StructureSDR BUEA2012011600002Warning Light · illuminatedRED GEAR DOOR UNSAFE LIGHT ILLUMINATED, APPROX 7-8 MINUTES INTO FLIGHT. FOUND RT UPLOCK CLOSED UPON LANDING. MX CREW PERFORMED SEVERAL GEAR EXTENSION AND RETRACTIONS AND COULD NOT DUPLICATE PROBLEM.Jan 16, 2012 · N236MJ · Gulstm GIV · Landing Gear Position and WarningSDR DXTA2012011704848Transducer · malfunctionedLOSS CONTROL OF AUTOMATIC PRESSURIZATION CLIMBING THRU 40,000 FEET, ASSOCIATE CAS MESSAGES, CABIN CLIMB TO 10,800 FEET. PAX MASK'S DIDN'T DROP. ON DESCENT MANUAL PRESSURIZATION APPEARED TO BE INOPERATIVE. POWERED ACFT & FOUND OUTFLOW VALVE WOULD NOT MOVE INJan 16, 2012 · N441QS · Gulstm GIV · Cabin Pressure Control SystemSDR DXTA2011122104830Microwave Oven · odorELECTRICAL BURNING ODOR FROM MICROWAVE OCCURED AT FLIGHT LEVEL 450. REMOVED & INSTALLED MICROWAVE IAW CMP 253010. OPS CHECKED NORMAL.Dec 21, 2011 · N489QS · Gulstm GIV · Buffet/GalleysSDR AOYA2011121500001Landing Gear · malfunctionedAFTER DEPARTURE, NOSE LANDING GEAR FAILED TO RETRACT. SEVERAL ATTEMPTS TO RETRACT WERE MADE WITH NO SUCCESS. AN UNEVENTFUL NORMAL LANDING WAS MADE. AFTER LANDING, GEAR PINNED AND A VISUAL INSPECTION MADE. MAIN GEAR DOORS WERE OPEN AND THE NOSE GEAR DOORS Dec 15, 2011 · N72MM · Gulstm GIV · Nose/Tail Landing GearSDR DXTA2011120804819Reservoir · leakingAMBER "COMBINED HYD QUANTITY" CAS MESSAGE AT FL410. THE COMBINED HYD SYS QTY INDICATION (EICAS) READS ZERO. THE FUSELAGE COMBINED SYS GAUGE ALSO READS ZERO. NO HYD FLUID FOUND IN EQUIPMENT BAY OR OUTSIDE FUSELAGE. R & R THE COMBINED HYD RESEVOIR & FOUND SATIDec 7, 2011 · N452QS · Gulstm GIV · Hydraulic Reservoir, MainSDR DVYA20111121001Skin Panel · crackedBAGGAGE DOOR FRAME LOWER CORNERS, FORE AND AFT, HAD OUTER SKIN PEELING BACK AND CRACKING FROM NORMAL WEAR. THIS AREA IS A SKIN BUILDUP AND IS SUSCEPTIBLE TO THE OUTER SKIN BEING SEPARATED AND/OR CRACKED FROM IN SERVICE LOADING AND UNLOADING. STRUCTURAL DER DNov 17, 2011 · N270SC · Gulstm GIV · Fuselage Main, Plate/SkinSDR GR4D20111111010Angle · crackedCAP ANGLE CRACKED.Nov 11, 2011 · N486QS · Gulstm GIV · Fuselage Miscellaneous StructureSDR GR4D20111111009Lug · corrodedVERTICAL LUG CORRODED.Nov 11, 2011 · N486QS · Gulstm GIV · Vertical Stabilizer, Attach FittingsSDR DVY2011F00000Winglet · corrodedDURING SCHEDULED ACCOMPLISHMENT OF CMP CODES 573013 (LT AND RT WINGLET ATTACH HARDWARE- INSP) CORROSION WAS NOTED IN SEVERAL OF THE HOLE BORES IN THE CENTER OF THE HOLES WHERE THE BUSHINGS DO NOT CONTACT EACH OTHER. MFG IS AWARE OF THIS CONDITION AND THE HOLENov 3, 2011 · N763DB · Gulstm GIV · Wing, Plate/SkinSDR W6J2011F00000Unknown · faultyLT ENG "FIRE LOOP A", CAS INDICATION AFTER TAKEOFF (1,000 AGL) FOR 4 MINUTE DURATION. NO OTHER INDICATIONS DURING OR AFTER CAS MESSAGE EXTINGUISHED. THIS IS AN INDICATION OF A FIRE LOOP A FAILURE, NOT AN ENGINE FIRE. AN EXTENSIVE INSP WAS PERFORMED INCLUDINOct 1, 2011 · N368AG · Gulstm GIV · Fire DetectionSDR DXTA2011091204718Warning Light · no indicationON APPROACH, DID NOT GET THE APPROACH ANNUNCIATION LIGHTS ON THE CDU OR ON DU4. FUNCTION TESTED THE NR 1 AND NR 2 GPS'S IAW MSG3 MM 34-52-00. ALL TESTS CHECKED GOOD. PERFORMED HYPER DEBUG PROCEDURE FOR FMS 1 AND FMS 2 IAW SIL D201105000003, REV 0. PERFORMESep 11, 2011 · N486QS · Gulstm GIV · Landing and Taxi AidsSDR GR4D20110907001Link · corrodedLEFT SUSPENSION LINK CORRODED.Sep 7, 2011 · N472QS · Gulstm GIV · Nacelle/Pylon, Main FrameSDR BUEAN236MJ01Attach Bracket · corrodedDURING WINGLET ATTACH HARDWARE INSP, (CMP 573013 & 573014), FOUND 15 OUT OF 32 HOLE BORES HAVE PITTING AND CORROSION THAT EXCEED ALLOWABLE LIMITS. FURTHER TESTING/INSP REVEALED CORROSION EXCEEDED STANDARD REPAIRABLE LIMITS.Aug 31, 2011 · N236MJ · Gulstm GIV · Wing, Attach FittingsSDR DXTA2011081604704Actuator · lack of lubeFLAPS FAILED TO FULLY RETRACT AFTER TAKEOFF, FLAPS STUCK AT 10. OPERATED FLAPS NUMEROUS TIMES, NO DEFECTS NOTED. OBSERVED FLAP ACTUATOR SCREWS WERE DRY WITH NO LUBE. LUBRICATED ALL FOUR FLAP ACTUATORS AND TRAVEL NUTS. COMPLIED WITH FLAP RIGGING CHECKS, NO DAug 14, 2011 · N452QS · Gulstm GIV · Trailing Edge Flap ActuatorSDR 9JLA201110081527Controller · defectiveCREW REPORTED THE THE NR 1 DISPLAY CONTROLLER INOPERATIVE. REMOVED THE FAILED NR 1 DISPLAY CONTROLLER SN 87040171. INSTALLED A REPAIRED UNIT, FUNCTIONALLY CHECKED SATISFACTORY.Aug 2, 2011 · N271PS · Gulstm GIV · Central DisplaySDR XGC2011F00000Converter · smokeSMOKE OF UNKNOWN ORIGIN COMING FROM GALLEY INFLIGHT. MX , SMOKE DAMAGED 60 HZ CONVERTER LOCATED BEHIND GALLEY TRASH BIN PANEL. PLUG REMOVED ON AFFECTED COMPONENT. (1) FLIGHT TO HOME BASE FOR FURTHER C/A ITEM ADDRESSED ACCORDING TO ACFT MEL PROCEDURES ACCOCIJul 31, 2011 · N200LC · Gulstm GIV · Buffet/GalleysSDR IMJA20110901001Torque Tube · crackedCOPILOT'S SEAT WAS REMOVED FOR RECOVERING. DURING THE RECOVERING IT WAS NOTICED THAT THE SEAT HEIGHT ADJUSTMENT TORQUE TUBE WAS CRACKED. THE TECHNICIANS WORKING ON THE SEAT ADVISED THAT THIS IS NOT AN UNCOMMON FAILURE.Jul 29, 2011 · N888ZF · Gulstm GIV · Flight Compartment EquipmentSDR DXTA2011070504643O-Ring · wornLOSS OF FLUSH HYD FLUID IN FLIGHT. FLUID IS LEAKING OUT OF RT ENGINE. INSPECTED RT ENGINE FOR HYD LEAKS AND FOUND A LEAK AT THE HYD PUMP LEAK WAS COMING FROM BETWEEN HYD PUMP AND ATTENUATOR. UPON FURTHER INSPECTION, FOUND O-RING FOR ATTENUATOR WORN AND THAJul 2, 2011 · N492QS · Gulstm GIV · Hydraulic System, MainSDR DXTA2011061404614Actuator · out of rigAFTER TAKEOFF, DURING FLAP RETRACTION, FLAPS MOVED TO 0 AND STABILIZER STUCK BETWEEN UP AND TAKEOFF. YELLOW CAS MSG ILLUMINATED STABILIZER-FLAP FAIL. FOUND STAB ACTUATOR WAS OUT OF RIG, MANUALLY RAN STAB ACTUATOR FULL UP & FULL DOWN. NO BINDING NOTED. PERFOJun 13, 2011 · N441QS · Gulstm GIV · Elevator Control SystemSDR BJYA1179Support Fitting · corrodedDURING AN INSPECTION OF THE COCKPIT OVERHEAD EVIDENCE OF CORROSSION WAS NOTED IN THE STRUCTURE LOCATED ABOVE THE WINDSCREENS. THIS IS T STRUCTURE ABOVE/BETWEEN THE WINDSCREENS WHICH IS PART OF THE AIRCRAFT PRIMARY STRUCTURE.Jun 13, 2011 · N527JC · Gulstm GIV · Fuselage Miscellaneous StructureSDR BQVA2011061300010Structure · corrodedDURING COMPLIANCE OF CMP CODES 573013 & 573014 WINGLET ATTACH HARDWARE (LEFT & RIGHT) - INSPECTION, SOME CORROSION WAS FOUND IN THE WINGLET ATTACH BORES ONCE THE BUSHINGS WERE REMOVED.Jun 8, 2011 · N227SV · Gulstm GIV · Wing Miscellaneous StructureSDR ZLWA20110608003Valve · inoperativeLEFT WING STARTED VENTING FUEL IN CLIMBOUT. AFTER TROUBLESHOOTING TECHNICIANS FOUND LEFT WING OUTBOARD AFT VENT FLOAT/ NON RELIEVING VALVE TO BE INOP. REPLACED VALVE WITH A NEW VALVE, P/N 16F123 AND SEAL, P/N GA215-160 IAW GULFSTREAM G-IV MAINTENANCE MANUAL Jun 5, 2011 · N36MW · Gulstm GIV · Fuel StorageSDR 9JLA1516Iru · defectiveTHE CREW REPORTED THE IRS NR 1 "FAULT" LIGHT ILLUMINATED. REMOVED THE DEFECTIVE NR 1 IRU AND INSTALLED A REPAIRED UNIT. FUNCTIONAL CHECK SATISFACTORY.Jun 1, 2011 · N271PS · Gulstm GIV · Inertial Guidance SystemSDR 9JLA1517Gyro · defectiveCREW REPORTED THAT THE STAND-BY ATTITUDE INDICATOR INDICATES LEFT BANK IN LEVEL FLIGHT. FUNCTIONAL CHECKS FOUND THE STAND-BY HORIZON GYRO DEFECTIVE. REPLACED THE GYRO WITH OVERHAULED UNIT, FUNCTIONAL CHECKS SATISFACTORY.Jun 1, 2011 · N271PS · Gulstm GIV · Attitude Gyro and Indicating SystemSDR UG8A2011050101Mount Fitting · corrodedHORIZONTAL STABILIZER PIVOT BEARING FITTING BORES ARE CORRODED. MADE REPAIRS TO LT LUG IAW FAA APPROVED REPAIR DWG SE05455902 REV A. FIRST OVERSIZE REPAIR INCORPORATED. INSTALLED HORIZONTAL STABILIZERMay 1, 2011 · N600VC · Gulstm GIV · Horizontal Stabilizer, Attach FittingsSDR GR4D20110412002Winglet · corrodedLT WINGLET CORRODED.Apr 12, 2011 · N472QS · Gulstm GIV · Wing Main, Frame StructureSDR WWQA04111Door Seal · deflatedAPPROX 2.5 HOURS INTO THE FLIGHT THE CREW NOTICED THEY WERE LOOSING CABIN PRESSURIZATION THEY DESENDED TO 350 AND WAS ABLE TO CONTROL THE PRESSURIZATION .5 HOURS AFTER THE DESENT TO 350 THE CREW HEARD A LOUD WIND NOISE COMING FROM THE MAIN ENTRY DOOR AND COULDApr 7, 2011 · N848GF · Gulstm GIV · Passenger/Crew DoorsSDR DXTA2011022804482Acm · overtempENROUTE BCT-TNCM AMBER LT COOL TURBINE HOT ILLUMINATED. CABIN FILLED WITH SMOKEY ODOR - INCREASED CABIN TEMP AND LIGHT WENT OUT. REPLACED LEFT ACM . COMPLIED WITH OPS AND LEAK CHECKS WITH NO FAULTS FOUND. ALL WORK IAW MM 21-01-09, 21-00-00, 21-01-00 AND 21-Feb 26, 2011 · N441QS · Gulstm GIV · Cabin Cooling SystemSDR 2011F00026Pump · damagedWHILE ON OUTBOUND FLIGHT, THE PILOT REPORTED LOSS OF THE COMBINED HYD PRESSURE AND FLUID; AUXILIARY PUMP TEMPORARILY FAILED, TOO. PILOT MADE UNSCHEDULED LANDING. ON GROUND, THE NR 1 ENGINE DRIVEN PUMP, FOUND WITH BLOWN-OUT GASKET CAUSING HYD LOSS AND DAMAGE Jan 31, 2011 · N525KF · Gulstm GIV · Hydraulic Pump (Electric/Engine), MainSDR 2011F00022Electronic Unit · intermittentIMMEDIATELY AFTER REACHING CRUISING ALTITUDE OF FL410, THE CREW NOTICED THE LT AUTOTHROTTLE ADVANCING FOLLOWED IMMEDIATELY BY A MASTER CAUTION CHIME/LIGHT. CAS MESSAGES OF LT FUEL PRESS LOW (RED CAPTION), LT MAIN FUEL FAIL (AMBER), LT ALT FUEL FAIL (AMBER). Jan 25, 2011 · N450JE · Gulstm GIV · Fuel Boost PumpSDR DXTA2011012704434Coalescer Bag · odorSTRONG EXHAUST & FUEL ODOR PREVALENT IN CABIN UPON DESCENT. ODOR WAS VERY STRONG AND WAS FIRST NOTICED ON DESCENT THROUGHOUT APPROXIMATELY 10,000FT. R & R WATER SEPARATOR BAGS . PERFORMED OPS AND LEAK CHECKS WITH NO DEFECTS OR ODORS NOTED. ALL WORK DONE IAWJan 24, 2011 · N436QS · Gulstm GIV · Humidity Control System
Back to Gulfstream Aerospace G-IV