SDR 06FDEA04073Skin · corrodedMAIN CABIN SEVERE CORROSION WITH EXFOLIATION ON LONG 17 RT FROM STA 1501 TO STA 1521. REMOVED FASTENERS IN CORRODED AREA IAW SRM 51-35-01 VOL 2. REMOVED CORROSION IAW SRM 53-00-01 FIG 1B VOL 1. ORIGINAL THK IS .105" IAW DWG AEA0220 (-1). RESIDUAL THK IS 0,SDR 06FDEA04072Skin · corrodedMAIN CABIN LIGHT CORROSION WITH EXFOLIATION ON LONG 17 RT BTWN STA 1159 AND STA 1179. REMOVED FASTENERS IN CORRODED AREA IAW SRM 51-35-01 VOL 2. REMOVED CORROSION IAW SRM 53-00-01 FIG 1B VOL 1. ORIGINAL THK IS .105" IAW DWG AEA0220(-509). RESIDUAL THK IS 0,SDR 06FDEA03966Control Valve · malfunctionedAFTER TAKEOFF CLIMBING THRU 1000' WITH ENGINE AND WING ANTI-ICE ON THE NR 3 MANIFOLD FAIL LIGHT CAME ON. REMAINED OUT OF ICING. LANDED AT NEAREST SUITABLE AIRFIELD, KSTL. RT WING PRESSURE SWITCH FAULTED IN CAC. DROPPED FLAPS/SLATS AND CHECKED WING ANTI-ICESDR 06FDEA03962Pressure Switch · failedNR 3 MANIFOLD LT, ILLUMINATED PASSING 3000 WITH FE STANDARD PANEL SETUP. ENGINE WING ANTI-ICE ON PRESSURE WAS 60. FOLLOWED QRH AFTER PHASE ONE PRESSURE, REMAINED AT 40. THROTTLE BROUGHT TO IDLE, PRESS DROPPED TO 20 DURING RTB TO MEM FACT, 11NOV06 20:47 MESDR 06FDEA03915Support Fitting · crackedLT O/B FLAP I/B HINGE FWD SUPPORT FITTING CRACKED AT FWD NOSE SECTION REMOVED FASTENERS FOR NDT ACCESS. PERFORMED HFEC INSPECTION ON FWD HINGE SUPPORT FITTING I/B AND O/B HALVES FROM FWD END TO PERIPHERY AND IMMEDIATE AREAS OF THE FIRST THREE FASTENERS (3EA).SDR 06FDEA03795Warning Light · illuminatedON APPROACH CONFIGURING NORMALY TO 22DEGS / EXT GEAR DOWN. WHEN SELECTING 35 / EXT GOT RED DIS-AGREE LIGHT. RAN RED TABS AND PUT FLAPS / SLATS IN 22 DEGS FOR LANDING. NO OTHER PROBLEMS NOTED. MEL 26OCT06 16:17 SJC R ACN RELEASED FOR SERVICE PER MEL/CDSDR 06FDEA03787Transmitter · malfunctionedLEVELED AT FL290 ATC SLOWED US TO 250 KNOTS. S/O REPORTED NR 3 ENGINE FUEL PRESSURE GAUGE STARTED TO FLUCTUATE. NOTICED NR 3 N1 RPM DROPPING AND ASSOCIATED REDUCTION IN EGT AND N2. PERFORMED IN FLIGHT ENG SHUT DOWN. RETURNED AND LANDED MEM WITHOUT INCIDENSDR 0602331235Connector · looseNR 2 PNEUMATIC FAIL LIGHT ILLUMINATED ON TAKEOFF ROLL. TAKEOFF ABORTED AT 140 KNOTS AND RETURNED TO GATE. MAINTENANCE TROUBLESHOT AND TIGHTENED LOOSE CONNECTION. CHANGED NR 2 PRECOOLER AND DEFERRED MANIFOLD DETECTOR. OPERATION CHECKS GOOD. SDR CNMA20060028Battery Pack · inoperativeON PRE-FLIGHT, FOUND OVERWING EMERGENCY LIGHTS INOP. REPLACED OVERWING BATTERY PACK. OPS CKS OK IAW MM 33-51.SDR CNMA20060027Power Supply · no testEMERGENCY LIGHT TEST LT WILL NOT ILLUMINATE WHILE PERFORMING COM TEST. ALL LIGHT CHECK AS COMING ON WITH TEST. REMOVED AND REPLACED L3 BATTERY PACK AND CHARGER ASSY IAW AMM 33-50. REMOVED AND REPLACED L4 BATTERY CHARGER ASSY IAW AMM 33-50.SDR CNMA20060026Resistor · failedDURING PAX LOADING SMOKE AND ELECTRICAL FUMES NOTED BY CREW, BY L-4 DOOR PA PNL. DE-PLANED ACFT, FIRE DEPT NOTIFIED. INSPECTED L-4 DOOR FLIGHT ATTENDANT PA PANEL WIRING IAW MM 20-30. FOUND WITH FIRE DEPARTMENT THAT THE L-4 DOOR RESISTOR R4-139 HAD OVERHEATESDR WRLA2006097Door · missingDURING WALKAROUND FOUND MISSING PRESSURE RELIEF DOOR FROM NR 1 ENG LT HAND SIDE CORE COWL, DOOR HINGE DAMAGED AND COWLING SKIN CRACKED ABOUT .875 INCH FORWARD OF DOOR HINGE AREA; CHECKED WING FUSELAGE AND TAIL, NO DAMAGE NOTED. REPAIRED AS PE 14-121-379 BOEINSDR CNMA20060025Encoder · odor6 HOURS INTO FLT, THE CREW NOTICED AN ELECRICAL ODOR IN "C" ZONE SEATS 37-40 RIGHT SIDE OF ACFT. PULL ALL CB'S IN "C" ZONE ASSOC WITH LIGHTING / DECODERS. AFTER CB'S PULLED, ODOR STARTED GOING AWAY. REPLACED ENCODER IAW MM 23-33. OPS CK NORMAL.SDR WRLA2006079Pressure Panel · corrodedDURING C-CHECK IN GSO FOUND LT WHEEL WELL BS1521 LOWER WEB HAS SEVERE INTERGRANUALAR CORROSION. REMOVED AND REPLACED WITH A NEW FABRICATED INTERCOASTAL IAW DAC DWG AEA7163, ALODINED, PRIMED AND PAINTED IAW SRM 51-21-01 VOL II.SDR WRLA2006078Angle · corrodedDURING "C" CHECK IN GSO, FOUND LEFT WHEEL WELL BS1521 INBOARD BULKHEAD ANGLE CORRODED. REMOVED AND REPLACED WITH A NEW FABRICATED ANGLE IAW DAC DWG AEA0025, ALODINED, PRIMED AND PAINTED IAW DC10 SRM 51-21-01 VOL II.SDR WRLA2006077Stiffener · corrodedDURING C-CHECK IN GSO FOUND LT WHEEL WELL BS1521 OB STIFFNER ANGLE HAS SECTION MISSING DUE TO CORROSION. REMOVED AND REPLACED STIFFNER WITH A NEW FABRICATED STIFFNER IAW DAC DWG AEA0025, ALODINED, PRIMED AND PAINTED IAW SRM 51-21-01 VOL II.SDR 0601941223Encoder · odorAPPROX 2 HRS AFTER DEPARTURE NOTICEABLE ELECTRICAL TYPE ODOR COMING FROM SEAT 17A AND B. ELECTRICAL BOX UNDER SEAT 17A QUITE WARM. READING LIGHTS IN COACH WOULD NOT TURN OFF WITH MASTER SWITCH. PULLED CB'S. FLIGHT DIVERTED TO DLH AND LANDED WITHOUT INCIDENT. RSDR 0601891240Bottle · dischargedDURING LINE CHECK FOUND DOOR 4L PNEUMATIC BOTTLE DISCHARGED. MAINTENANCE CHARGED BOTTLE IAW 52-12-06 AND PRESSURE INDICATES WITHIN LIMITS.SDR 0601881240Bottle · lowDURING LINE CHECK FOUND DOOR 4R PNEUMATIC BOTTLE PRESSURE AT ZERO. ICN MAINTENANCE ATTEMPTED TO RECHARGE BOTTLE BUT WERE UNSUCCESSFUL. DEFERRED IAW MEL 52-10 AND INSTALLED PLACARD NR 032612. HNL MAINTENANCE RESET PLUNGER ABOVE BOTTLE AND SERVICED IAW MM 52-12-SDR 06FDEA03142Handle · pulledDESCENDING THRU 4000 FT GOT BOTH LEFT AND RIGHT CABIN DOOR ANNUNCIATOR LIGHTS ILLUM. PRESSURIZATION WENT TO ZERO DIFF PRESS AND CABIN ALT= ACFT ALT. LANDED EWR WITHOUT INCIDENT. FOUND BOTH AFT DOORS OPEN ON WALKAROUND, TRIED TO ELECTRICALLY CLOSE DOORS NOSDR CNMA20060023Seal · cutABOUT 1.5 HRS INTO FLIGHT NR3 ENG OIL PRESSURE WENT TO 10 PSI, NR3 ENG OIL QUANTITY WENT TO ZERO. PERFORMED PRECAUTIONARY ENG SHUTDOWN NR3 ENG. UPON INSPECTION OF ENGINE FOUND HYDRAULIC PUMP LOCKOUT KIT LEAKING. REF DMI NR 8739. REMOVED LOCKOUT KIT AND FOUNDSDR CNMA20060022Floor Support · corrodedDURING ACCOMPLISHMENT OF TASK CARD SWF858 DETAILED VISUAL INSPECTION FOUND LEVEL 2 CORROSION ON FLOOR SUPPORT FRAME. REPLACED FLOOR ACA 7364-2 BEAM PER SRM VOL 2 51-30.SDR CNMA20060021Power Supply · no testDURING SERVICE CHECK, OPERATIONAL CHECK OF EMERGENCY LIGHTS FAILED. TROUBLESHOT TO EMERGENCY BATTERIES TESTED BAD. REMOVED AND REPLACED EMERGENCY BATTERY PACK AND CHARGER ZONE A AND REMOVED AND REPLACED BATTERY PACK AND CHARGER ZONE B. PRECAUTIONARY REMOVEDSDR WRLA2006071Seat Track · corrodedDURING C-CHECK IN GSO FOUND MAIN CABIN BETWEEN STA 824 TO 899 SEAT TRACK AT APPROX RBL 106 CORRODED. REMOVED AND REPLACED SEAT TRACK SECTION FROM STA 765 TO 910 WITH A NEW SEAT TRACK IAW DC10-30 SRM 53-70-00 VOL I.SDR WRLA2006074Seat Track · corrodedDURING C-CHECK IN GSO FOUND CABIN SEAT TRACK AT LBL 28 BS 1481-1491 CORRODED INSIDE LUGS. REMOVED AND REPLACED SEAT TRACK SECTION FROM STA 1391 TO 1531 WITH A NEW SEAT TRACK IAW DC10-30 SRM 53-70-00 VOL I.SDR WRLA2006073Seat Track · corrodedDURING C-CHECK IN GSO FOUND CABIN SEAT TRACK AT LBL 28, BS 1400 TO 1412 HAS CORROSION INSIDE LUGS AND IN UPPER SURFACE OF TRACK. FABRICATED REPAIR PART AND INSTALLED IAW DC10-30 SRM 51-31-01 VOL II, REMOVED AND REPLACED SEAT TRACK SECTION FROM STA 1391 TO 151SDR WRLA2006072Mount · crackedDURING C-CHECK IN GSO FOUND LAV-B OUTBOARD AFT MOUNT CRACKED AND CORRODED. REMOVED AND REPLACED LAV-B OUTBOARD AFT MOUNT IAW DC10 MM 25-00-00.SDR CNMA20060020Power Supply · inoperativeEMERG LIGHT TEST FAILED AT PRE-FLIGHT. T/S FOUND EMERGENCY LIGHT AT THE NR 4 DOORS INOP. REMOVED AND REPLACED BATTERY POWER SUPPLY AT THE 4 DOORS. OPS CHECK GOOD IAW 33-51.SDR WRLA2006054Channel · corrodedITEM: DURING "C" IN GSO FOUND HAT CHANNEL HAS SURFACE CORROSION AROUND FASTENER HOLE AT STA 1921 BL0. REMOVED AND REPLACED HAT CHANNEL IAW SRM 51-31-01 VOL II.SDR WRLA2006063Floorbeam · crackedDURING C-CK IN GSO FOUND MAIN CABIN FLOORBEAM CRACKED AT STA 1482 B/N LBL 107 AND LBL 80. FABRICATED FLOOR SUPPORT IAW DC 10 DWG. INSTALLED FLOOR SUPPORT.SDR WRLA2006056Seat Track · corrodedITEM: DURING "C" IN GSO FOUND SEAT TRACK CORRODED AT LBL28 STA 420-457. REMOVED AND REPLACED SEAT TRACK IAW SRM 51-31-01 VOL II.SDR WRLA2006053Floor Support · corrodedITEM: DURING "C" IN GSO FOUND FLOOR BOARD SUPPORT CHANNEL CORRODED ON UPPER SURFACE APPROX STA 1915. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT IAW SRM 51-31-01 VOL II.SDR WRLA2006050Floor Support · corrodedITEM: DURING "C" IN GSO FOUND FLOOR BOARD SUPPORT CHANNEL HAS SURFACE CORROSION AT STA 1877 - 2007 RBL26. REMOVED AND REPLACED FLOOR SUPPORT CHANNEL IAW SRM 51-31-01 VOL II.SDR 06FDEA2917Release Cable · damagedDURING GEAR RETRACTION THE RT GEAR INDICATED DOWN (RED LIGHTS) FROM BOTH GEAR POSITION INDICATORS. ALL OTHER GEAR SHOWED UP AND OUT. KEPT A/C AT 230 KNTS AND 5000 FT TO PREFORM QRH PROCEDURES. BOTH LIGHTS WENT OUT BRFORE QRH PROCEDURES WERE PREFORMED, THEN BOTSDR WRLA2006064Web · crackedDURING C-CK IN GSO FOUND WEB AT STA 1960-1986 AT RBL 50 CRACKED AROUND FASTENER HOLES. REMOVED WEB IAW DC10 SRM 51-31-01 COL II. FABRICATED DOUBLER IAW DC10 SRM 53-16-01 VOL III. ALIGNED, PRIMED, AND PAINTED, IAW DC10 SRM 51-21-01 VOL I. INSTALLED DOUBLER SDR WRLA2006042Intercostal · corrodedITEM: DURING "C" IN GSO FOUND CABIN ZONE 220 UNDER FLOOR AREA STA 475 BL95R CORRODED INTERCOSTAL. FABRICATED INTERCOSTAL IAW DC10 DRWG 7186-502. ALODINED & PRIMED IAW DC10 SRM 51-21-01 VOL II. INSTALLED FLOOR SUPPORT IAW SRM 51-31-01.SDR WRLA2006041Floor Support · corrodedITEM: DURING "C" CHECK IN GSO FOUND MAIN CABIN AT STA 828 AT BL-0 FLOOR SUPPORT CORRODED. REPLACED FLOOR SUPPORT BEAM IAW DC10 SRM 51-31-01 VOL II.SDR 06FDEA2907Bulkhead · crackedNR 3 PYLON AFT BULKHEAD IB HORIZONTAL FLANGE AT RADIUS IS CRACKED FROM FWD EDGE TO AFT RADIUS, APPROX 2 INCHES IN LENGTH H.F.E.C. INDICATION AND VARIFED WITH BOROSCOPE. (PICTURE TAKEN) ENGINEERING NOTIFIED. REPLACED BULKHEAD PER WO 00033604 AND EA 8-5410-90SDR WRLA2006048Floor Support · corrodedITEM: DURING "C" IN GSO FOUND MAIN CABIN AT STA 832 AT APPROX RBL46 TO LBL46 FLOOR SUPPORT CORRODED. REMOVED AND REPLACED FLOOR SUPPORT BEAM IAW SRM 51-31-01 VOL II.SDR WRLA2006043Floor Support · corrodedITEM: DURING "C" CHECK IN GSO FOUND CABIN ZONE 220 UNDER FLOOR AREA STA 450 BL35L SCALLOPED BEAM CAP CORRODED. REMOVED AND FABRICATED NEW FLOOR SUPPORT IAW DOUGLAS DWG ABA8306 REV K. INSTALLED FLOOR SUPPORT IAW SRM 51-35-01 VOL II.SDR WRLA2006059Floor Support · corrodedITEM: DURING "C" IN GSO FOUND FLOOR SUPPORT IN MAIN CABIN HAS CORROSION AT STA 879 RBL60. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT IAW SRM 51-31-01 VOL II.SDR 06FDEA2849Support · corrodedTHE RIGHT INBOARD AILERON SUPPORT ASSY ACTUATOR A FRAME, O/B BARREL NUT BOLT HOLE IS CORRODED.SDR CNMA20060019Blades · brokenDURING TAKEOFF ROLL NR 3 ENGINE EGT INDICATOR SHOWS RAPID EGT RISE AT TEMP 945 DEGREES AMBER LIGHT CAME ON AND TEMP EXCEEDED 950 DEGREES AND KEPT RISING. F/E REDUCED THRUST NR 3 ENGINE TO PREVENT OVERTEMP AND WHEN DIFFERENCE BETWEEN N1, NR3 ENGINE AND OTHERS RSDR WRLA2006047Floor Support · corrodedITEM: DURING "C" IN GSO FOUND MAIN CABIN BETWEEN STA 808 TO 899 FLOOR SUPPORT AT APPROX RBL 46 CORRODED. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-31-01 VOL I.SDR WRLA2006046Longeron · corrodedITEM: DURING "C" CHECK FOUND AT STA 1521 LONGERON 46L HAS EXFOLIATION AND HEAVY PITTING CORROSION. FABRICATED NEW REPAIR ANGLE AND CHANNEL, INSTALLED PER SRM CHAP 51 VOL II.SDR WRLA2006040Floor Support · corrodedITEM: DURING "C" CHECK IN GSO FOUND MAIN CABIN FLOOR PANEL NR 224AF SUPPORT CORRODED BEYOND LIMITS. REMOVED AND REPLACED SUPPORT IAW WITH SRM 51-31-01 VOL II.SDR CNMA20060018Manifold · crackedDURING THE TAKEOFF ROLL NR 3 ENG EGT BEGAN TO CLIMB ABOVE 950 DEGREES. THE ENGINEER PULLED NR 3 THROTTLE BACK ATTEMPTING TO BRING NR 3 EGT INTO LIMITS, THE CORRESPONDING DROP IN N1 WAS ALREADY AT 5 PERCENT LESS THAN THE N1 LIMIT AND THE EGT WAS STILL EXCEEDINSDR WRLA2006060Floor Support · corrodedITEM: DURING "C" IN GSO FOUND FLOOR SUPPORT IN MAIN CABIN HAS CORROSION AT STA 824 RBL60. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT IAW SRM 51-31-01 VOL II.SDR WRLA2006058Floor Support · corrodedITEM: DURING "C" IN GSO FOUND FLOOR SUPPORT IN MAIN CABIN HAS SURFACE CORROSION AT STA899 RBL60. REMOVED AND REPLACED WITH NEW FLOOR SUPPORT IAW SRM 51-31-01 VOL II.SDR WRLA2006052Floor Support · corrodedITEM: DURING "C" IN GSO FOUND FLOOR BOARD SUPPORT CHANNEL HAS SURFACE CORROSION AROUND NUT PLATE CLIP HOLES AT STA 1900 LBL22-RBL22. REMOVED AND REPLACED FLOOR SUPPORT CHANNELS IAW SRM 51-31-01 VOL II.
Back to Mcdonnell-Douglas DC-10-30