Mcdonnell Douglas DC-8-63
Service difficulty reports · 1,601
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC863' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC863' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA9701548Rib · crackedLEFT WING L/E RIB IS CRACKED AT STA XFS 628.75 AFT UPER END. REPAIRED IAW SRM 57-2-0, SRM 51-1-21, AND SRM 51-1-21.SDR ABXA9701489Intercostal · corrodedFS 8 TO FS 25 STR 30R INTERCOSTAL ATTACH ANGLE CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT ANGLE IAW SRM 51-1-21 AND DWG 5615530.SDR ABXA9701488Fitting · corrodedLONGERON 30R END FITTING CORRODED FWD OF FRAME 8. FABRICATED AND INSTALLED REPLACEMENT FITTING IAW SRM 53-1-0, 51-1-21, 51-1-20D AND DWG 4641704.SDR ABXA9701487Longeron · corrodedLONGERON 27R-CORRODED BEYOND LIMITS FS 8 TO FS 70. FABRICATED AND INSTALLED REPLACEMENT FITTING IAW SRM 51-1-21 AND DWG 3648666.SDR ABXA9701486Fitting · corrodedBATH TUB FITTING EXFOLIATED OUT OF LIMITS FS 1180 L-35R TO 36. REMOVED AND REPLACED FITTING IAW SRM 51-1-20D.SDR ABXA9701485Stiffener · crackedMAIN CABIN SUBFLOOR AT FS 782 RBL 46 STIFFENER FITTING IS CRACKED AT BOTTOM. FABRICATED AND INSTALLED REPLACEMENT FITTING IAW SRM 51-1-21, 51-1-20D, AND DWG 3641126.SDR ABXA9701484Fitting · crackedFWD ACCY COMPT STA 68D BL 0 THE SEAT TRACK SUPPORT FITTING IS CRACKED. FABRICATED REPLACEMENT FITTING IAW DWG 4645517 AND INSTALLED IAW SRM 51-1-29D.SDR ABXA9701483Fitting · crackedFWD ACCY COMPT STA 680 RBL 24 THE SEAT TRACK SUPPORT FITTING IS CRACKED. FABRICATED REPLACEMENT FITTING IAW DWG 4645517 AND INSTALLED IAW SRM 51-1-29D.SDR ABXA9701482Frame · crackedFWD ACCY COMP AT STA 66D BELOW STR 21R FRAME HAS 3 CRACK IN RADIUS. FABRICATED FRAME IAW SRM 53-2-0 AND DWG 3646688 AND INSTALLED IAW SRM 51-1-20D.SDR ABXA9701481Longeron · corrosionSTR 30R STA 8 TO STA 25 HAS HEAVY CORROSION. FABRICATED REPLACEMENT LONGERON IAW DWG 3648667 AND INSTALLED IAW SRM 51-1-20D AND 51-1-21.SDR ABXA9701480Splice · crackedSTR SPLICE CRACKED STA 440 TO 460 STR 30.L. REPLACED SPLICE IAW SRM 51-1-20D, 51-1-8 AND 51-1-11.SDR ABXA9701479Clip · crackedRT WING L/E STA XDLDI 6.225, THE UPPER INTERCOASTAL ATTACH CLIP IS CRACKED. REPLACED CLIP IAW SRM 51-1-4 AND INSTALLED IAW SRM 51-1-20D.SDR CKSA97487Switch · failedON GEAR RETRACTION DOORS NOT LATCHED LIGHT REMAINED ON. RECYCLED GEAR, LIGHT WENT OUT. SATISFACTORY GEAR UPLATCH CHECK IN CRUISE LIGHT CAME BACK ON FOR REMAINDER OF FLIGHT. FOUND RIGHT DOOR LATCH SWITCH AT FAULT. REMOVED AND REPLACED SWITCH. SYSTEM OPS CHSDR ABXA9701454Oil Press Vlv · defectiveDURING DESCENT, NR 4 ENGINE OIL PRESSURE DROPPED TO 32 PSI AND LOW OIL PRESSURE LIGHT CAME ON, QTY AND TEMP WERE OK. SECURED NR 4 ENGINE. REPLACED OIL PRESSURE RELIEF VALVE SEAT AND SPRINGS IAW DC8 MM CH 80. RAN ENGINE, OPS CHECK AND LEAK CHECKED GOOD IAW DSDR ABXA9701453Downlock Switch · intermittentDURING THE BEFORE LANDING CHECK LIST, WHEN LANDING GEAR HANDLE WAS PLACED DOWN, THE LEFT LANDING GEAR LIGHT DID NOT ILLUMINATE. RECYCLED GEAR ONCE AND THE LEFT GEAR INDICATION ILLUMINATED. FOUND LEFT MAIN LANDING GEAR DOWN LOCK SWITCH INTERMITTENT. REPLACEDSDR ABXA9701452Plug · misinstalledSHUT DOWN ENGINE NR 1 IN FLIGHT. OIL PRESSURE 30 PSI. NO NR 1 RED OIL PRESSURE LIGHT. AFTER SHUTDOWN PRESSURE 20-25 PSI, N-1 11 PERCENT, N-2 16 PERCENT. OIL TEMPERATURE AT SHUTDOWN 90 DEGREES C. AFTER SHUTDOWN 75 DEGREES C. DURATION AT WINDMILLING-25 MINUSDR ARWA970916Strip · corrodedDURING CPCP INITIAL INSPECTION, FOUND MAIN CARGO CABIN UNDERNEATH NR 4 CENTER FLOOR PANEL, METAL STRIP ON FLOOR SUPPORT STA 100 SURFACE CORRODED LEVEL 1. REMOVED CORROSION, FOUND TO BE BEYOND LIMITS IAW 51-1-8, FABRICATED PARTS I/A/W DER APPROVED DRWG NR 9709SDR ABXA9701590Rib · crackedRT WING L/E AT STA XFS 847.50, THE UPPER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701589Rib · crackedLT WING L/E RIB AT STA 816.25 IS CRACKED AT THE AFT LOWER END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701588Rib · crackedLT WING L/E RIB AT STA XFS 835.00 IS CRACKED AT THE AFT UPPER END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701587Rib · crackedLT WING L/E RIB AT STA XFS 791.25 IS CRACKED AT THE AFT UPPER END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701586Rib · crackedRT WING L/E AT STA XFS 785.0 THE LOWER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0 FIG 2, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701585Rib · crackedLT WING L/E RIB AT STA XFS 822.50 IS CRACKED AT THE AFT LOWER END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701584Rib · crackedRT WING L/E AT STA XFS 760.00 THE UPPER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701583Rib · crackedRT WING L/E AT STA XFS 803.75 THE UPPER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR AND INSTALLED PER SRM 57-2-0 FIG 2, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701582Rib · crackedRT WING L/E AT STA XFS 810.00 THE UPPER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701581Rib · crackedRT WING L/E AT STA XFS 816.250 THE UPPER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0 FIG 2, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701580Rib · crackedRT WING L/E AT STA XFS 778.75 THE UPPER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701579Rib · crackedRT WING L/E AT STA XFS 766.25 THE UPPER L/E RIB IS CRACKED AT THE AFT END. FABRICATED REPAIR ANGLE AND INSTALLED PER SRM 57-2-0, SRM 51-1-20D AND SRM 51-1-21.SDR ABXA9701561Intercostal · crackedINTERCOSTAL FWD END CRACKED JUST AFT OF STA 1520 AT LONGERON 33L. REPAIRED INTERCOSTAL IAW SRM 53-2-0, 53-4-1, AND 51-1-8.SDR ABXA9701492Fitting · crackedSTA 1040 TO 1060, STR 31L SPLICE FITTING IS CRACKED ON UPPER LEG FWD END. REPLACED FITTING AT STR 31L, STA 1040 TO 1060 IAW SRM 51-1-20.SDR ABXA9701491Frame · crackedSTA 1160 FRAME IN C-3 PIT IS CRACKED IN 2 PLACES. STR 30R TO 32R AND STR 34R TO 35R. REPLACED FRAME IAW SRM 51-1-20D.SDR ABXA9701490Doubler · corrodedFINGER DOUBLER CORRODED BEYOND LIMITS AT LONGERON 31R AT FS 12. FABRICATED FINGER DOUBLER IAW SRM 53-1-0 AND DWG 5613821. INSTALLED DOUBLER IAW SRM 51-1-21.SDR ARWA970914Stringer · crackedDURING CPCP INITIAL INSPECTION, FOUND FWD LOWER CARGO FS 220, STRINGER 36 IS CRACK AT FWD END MKD. REMOVED DAMAGED SECTION. INSTALLED NEW CHANNEL SECTION AND SPLICED IAW DER DRWG NR 97082902 WO 970035 N/R NR 5051.SDR ARWA97015Stringer · corrosionDURING CPCP INITIAL INSPECTION, FOUND FWD LWR CARGO FS 200/200, STRINGER 35RT HAS CORROSION. REMOVED CORROSION I/A/W SRM 51-1-8, AREA WAS FOUND BEYOND LIMITS I/A/W SRM 53-2-0 INSTALLED REPAIR AND FASTENERS I/A/W DER NR 97090302 APPROVED ON FAA FORM 81103 SIGNSDR ARWA970917Hinge Valve · crackedDURING CPCP INITIAL INSPECTION, FOUND MAIN CARGO DOOR HINGE HAS EVIDENCE OF ONE HINGE LOSE CRACKED, LOCATED 2ND LOBE FROM AFT END, TOP SIDE. REMOVED CRACKED HINGE AND INSTALLED NEW HINGE HALF AFT SIDE P/N MS 2000116 I/A/W 51-3-0. ACCOMPLISHED OPERATIONAL CHESDR ARWA970913Longeron · corrodedDURING CPCP INITIAL INSPECTION, FOUND 'C' BELLY 'T' CLIP AT STA 1140 BETWEEN LONG 35L AND 34L HAS EXPOLIATION CORROSION ON BOTT FWD LEG, ALSO HAS MANY NUTS MISSING FROM FASTENERS IN SAME AREA. REMOVED CORROSION, FOUND TO BE BEYOND LIMITS FABRICATED DOUBLERS FSDR ARWA970919Fitting · corrodedDURING CPCP INITIAL INSPECTION, FOUND UPPER CABIN, FS 100 LONG 21R, FRAME ATTACH FITTING IS CORRODED AT BOTTOM FWD ATTACH POINTS. REMOVED CORROSION FROM FITTING IAW SRM 51-1-8. FOUND TO BE BEYOND LIMITS. INSTALLED NEW FITTING WO 970035 N/R 5006.SDR ARWA970911Fitting · corrodedDURING CPCP INITIAL INSPECTION, FOUND UPPER CABIN, FS 1520, LONG 21L, FRAME ATTACH FITTING HAS CORROSION. CLEANED CORROSOIN, FOUND TO BE BEYOND LIMITS IAW SRM 51-1-8. INSTALLED NEW FITTING P/N 4640162-IN IAW SRM 51-1-20C AND SRM 51-1-20D. WO 970035 N/R 5018SDR ARWA970910Fitting · corrodedDURING CPCP INITIAL INSPECTION, FOUND UPPER CABIN, FS 1500, LONG 21L, FRAME ATTACH FITTING HAS CORROSION. REMOVED CORROSION, FOUND TO BE BEYOND LIMITS IAW SRM 51-1-8 AND SRM 53-2-0. INSTALLED NEW FITTING P/N 4640162-502N WO 970035 N/R 5017.SDR ARWA970909Fitting · corrodedDURING CPCP INITIAL INSPECTION, FOUND UPPER CABIN, FS 1260, LONG 21L, FRAME ATTACH FITTING HAS CORROSION (FWD SIDE). REMOVED CORROSION AND FOUND BEYOND LIMITS I/A/W 51-1-8, FABRICATED FITTING I/A/W DAC AUTHORIZATION NR CI-P63-ATM-560 AND DAC ACTION 342952 WO SDR ARWA970908Fitting · corrodedDURING CPCP INITIAL INSPECTION, FOUND UPPER CABIN, FS 580, LONG 21R FRAME ATTACH FITTING HAS CORROSION ON FWD SIDE. REMOVED CORROSION ON FITTING I/A/W 51-1-8, FOUND TO BE BEYOND LIMITS, INSTALLED NEW FITTING P/N 4597643-2N I/A/W SRM 51-1-20D AND 51-3-0 WO 970SDR ARWA97012Fitting · corrodedDURING CPCP INITIAL INSPECTION, FOUND UPPER CABIN, FS 1540, LONG 21L, FRAME ATTACH FITTING HAS CORROSION. CLEANED CORROSION, FOUND TO BE BEYOND LIMITS I/A/W SRM 51-1-8 INSTALLED NEW FITTING P/N 4640162-502N I/A/W SRM 51-1-20D WO 970035 N/R 5019.SDR RRXA97220Fire Loop · malfunctionedNR 3 FIRE WARNING ON CLIMBOUT. SHUT DOWN ENGINE PER QRH. DISCHARGED BOTH FIRE BOTTLES. REMOVED AND REPLACED THE NR 3 ENGINE FWD AND AFT UPPER FIRE LOOPS, GROUND CHECKS NORMAL.SDR ABXA9701407Switch · defectiveON LANDING, WHEN GEAR HANDLE PLACED IN THE EXTEND POSITION, RIGHT GEAR DOWN LIGHT DID NOT ILLUMINATE. ACCOMPLISHED TOWER FLY-BY TO VERIFY GEAR DOWN. LANDING WAS UNEVENTFUL. REPLACED RIGHT MLG DOWN LOCK SWITCH, OPS CHECKED GOOD.SDR ABXA9701404Fitting · crackedFORWARD LOWER CARGO COMPARTMENT RIGHT SIDE FS 280 LONGERON 21R AT CROSS SLIDE DOOR CUTOUT, FORWARD UPPER CORNER FRAME TO FLOOR SUPPORT FITTING IS CRACKED. REPAIRED CRACKED FLOOR SUPPORT FITTING IAW DAC DWG 97540022 AND DC-8 SRM 51-1-24.SDR CKSA97477Fitting · corrodedDURING ROUTINE CPCP CHECK INSPECTION FOUND LEVEL 2 CORROSION, RT AT CUSP RING FITTING CORRODED STA 540. CLEANED CORROSION AND FOUND TO BE OUT OF LIMIT IAW DC8 SRM 53-2-0. REPLACED WITH NEW FITTING IAW DC8 SRM 53-2-0, 51-1-20D, AND 51-3-0. CORROSION TASK CARSDR CKSA97476Frame · corrodedDURING ROUTINE C-3 CHECK INSPECTION FOUND LEVEL 2 CORROSION, FS -20-0 POPPED RIVETS, CORROSION ON FRAME LT SIDE BY NOSE WHEEL DOOR. REPLACED POPPED RIVETS IAW SRM 51-1-21. REPAIRED CORRODED FRAME IAW SRM 53-2-0. NON-ROUTINE TASK CARD NUMBER 110375.SDR CKSA97475Fitting · corrodedDURING ROUTINE CPCP CHECK INSPECTION FOUND LEVEL 2 CORROSION, RT STA 460 RING TO CUSP FITTING CORRODED. REMOVED AND REPLACED CUSP FITTING IAW DC8 SRM 51-3-0, 51-1-20D. CORROSION TASK CARD NUMBER 557R-0552. NON-ROUTINE TASK CARD NUMBER 110540.SDR CKSA97474Fitting · corrodedDURING ROUTINE CPCP CHECK INSPECTION FOUND LEVEL 2 CORROSION, RT RING FITTING CORRODED AT CUSP STA560. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0 FIG 1F. REMOVED AND REPLACED IAW SRM 51-1-21. CORROSION TASK CARD NUMBER 557R-0552. NON-RO
Back to Mcdonnell Douglas DC-8-63