SDR DALA1123189871Floor Support · corrodedFWD WET AREA STA 200 BETWEEN LBL-22 AND LBL-44 FLOOR SUPPORT HAS CORROSION. FLOOR SUPPORT FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1. FABBED NEW FLOOR SUPPORT OUT OF 7075T66511 IAW DC9 SRM 53-10-1, 51-10-1. LOCATED AND DRILLED HOLES IAW DC9 SRM 51-10SDR DALA1131699858Floorboard · crackedPASSENGER CABIN FLOORBOARD NR 17 FIBERGLASS IS DAMAGED AND CRACKED. FABRICATED FLOOR PANEL ASSY NR 17 REF TRAVELER NR 87331210001, AND DWG NR 9923432. CORK TAPE TO BE ACCOMPLISHED ON WORK CARD NR 0590-40 20-8M, PG 7, PARA A/2. COMPLIED WITH ER/A 491545-14, SDR DALA1129879858Floor Skin · dentedCABIN FLOOR PNL 47D HAS PULLED SCREWS AND DENTS IN TOP SKIN. BLENDED DAMAGE, OUT OF LIMITS IAW SRM 53-01, PG 8. CUT OUT DAMAGE IAW SRM 53-05, PG 10. FABBED FILLER AND DOUBLER IAW SRM 53-05, PG 10, FIG 1. TREATED AND PRIMED FILLER AND DOUBLER IAW SRM 51-10-SDR DALA1128749858Skin · damagedCABIN FLOOR PANEL 58D HAS PUNCTURE IN TOP SKIN FABRICATED HAT CHANNEL, IAW SRM 53-05, PG 9-10. REMOVED DAMAGE FROM FLOOR PANEL TOP SKIN IAW SRM 53-01, PG 6, FIG 1 REPAIRED FLOOR PANEL IAW SRM 53-01, PG 1-2, 6-7, TREATED AND PRIMED FLOOR PANEL AND HAT CHANNELSDR DALA1128739858Floor Panel · corrodedCOCKPIT FLOOR PANEL 15 AFT SIDE HAS CORROSION ON UPPER SURFACE, AT SEVERAL AREAS. REMOVED FLOOR PANEL 15 IAW SRM 51-10-3, PARA 26. FABRICATED FLOOR PANEL IAW SRM 51-10-4, PG 1-2, 20, INSTALLED COCKPIT FLOOR PANEL 15 IAW SRM 51-10-3, PARA 26 DAMAGE EXCEEDS SDR DALA1128239858Skin · dentedCABIN FLOOR PNL 42D HAS SEVERAL DENTS IN TOP SKIN, OUT OF LIMITS IAW SRM 53-05, PGS 9-1 1, DUE TO CRACKS PRESENT IN DENTS. REMOVED 5 HAT CHANNELS IAW SRM 51-30-02, PG 28, TO FABRICATE NEW PANEL. FABRICATED FROM 7075T6.025", BATCH NR 0001825209, IAW SRM 51-30-SDR DALA1128229858Skin · crackedCABIN FLOOR PNL 92D HAS CRACKS IN TOP SKIN. REMOVED FLOOR PANEL IAW SRM 53-05, PG 4 AND 10. FABED UPPER SKIN IAW SRM 53-23-0, PG 9, FIG 4, SRM 51-10-4, FIG 3, FIG 7, SRM 51-10-2, PARA 4, FIG 9. INST FLOOR PANEL UPPER SKIN IAW SRM 51-30-2, FIG 3, AND SRSDR DALA1127389858Skin · corrodedFLOOR PANEL, 36D FWD END UPPER SKIN IS TORN AND SCREW HOLES ARE WORN AND CORRODED. BLENDED CORROSION IN LIMITS, CUT OUT DAMAGED HOLES, FABRICATED DOUBLER AND FILLER. INSTALLED DOUBLER AND FILLER IAW SRM 51-10-3, SRM 51-30-1, SRM 53-23-0, SRM 53-05, SRM 51-SDR DALA1127339858Floor Panel · crackedCABIN FLOOR PANEL 93B FWD END HAS BROKEN RIVET AND SCREWS PULLED THRU TOP SKIN. REMOVED BROKEN RIVET FWD END AND FOUNDTO BE A CRACK. CUT OUT DAMAGED AREA IAW SRM 53-05, PG 10, FIG 1 FABRICATED REPAIR DOUBLER & FILLER, IAW SRM 51-10-3, PG 31, 40, AND 41. INSTSDR DALA1126949858Floor Panel · damagedCABIN FLOOR PNL 40D IS BENT UP AND SCREW HOLE IS WORN. FOUND CRACKS AT SCREW HOLE IN FLOOR PANEL. REMOVED DAMAGED AREA IAW SRM 51-70-2, PG 209. REQ NDT TO CHECK CUTOUT AREA FOR CRACK. NDT FOUND NO CRACKS IAW NDT IAW SRM 53-05, PG 10. TREATED AND PRIMED CUSDR DALA1126909858Floor Panel · corrodedCOCKPIT FLOOR PNL JUST AFT OF 14 RT SIDE HAS CORROSION ON UPPER SURFACE. REMOVED FLOOR PANEL IAW DC9-A-20-10-00-401-926A-A. REMOVED CORR IAW DC9 SRM 51-10-3, PG 46-48, OUT OF LIMITS IAW SRM 53-01, PG 6-7. REMOVED HAT CHANNELS IAW SRM 51-30-2, PARA.7, FABBESDR DALA1126749858Structure · corrodedCABIN FLOOR STRUCTURE STA 160-165 BETWEEN LBL 8 AND LBL 16 HAS CORROSION. REMOVED CORROSION STA 160 TO 165, LBL 8 TO LBL 16 IAW DC9 SRM 53-10-3, PG 46 OUT OF LIMITS IAW DC9 SRM 53-01 PAGE 8, FIG 1. REMOVED EXFOLIATED PLATE IAW DC9 SRM 51-30-1. FABBED PLATESDR DALA1126649855Floor Support · corrodedCABIN FLOOR SUPPORT ANGLE AND UPPER CHORD OF FLOORBEAM HAS CORROSION STA 237, BL-0 TO RBL 22. CORR OUT OF LIMITS IAW SRM 51-01, REMOVED CORR ON FLOORBEAM UPPER CHORD IN LIMITS IAW SRM 51-01, PAGE 8. HFEC SURFACE INSP PER NDT SPM 06-10-01.001, NO CRACKS NOTEDSDR DALA1126469858Fitting · crackedSTA 1151 BELOW LONGERON 14R THERE IS A CRACK IN THE DOUBLER. REMOVED SHEAR CLIP PER SRM 51-30-5 PAGE 29 FABBED SHEAR CLIP WITH SHT 2014-T0, 0.050 IAW SRM 53-13-3, PAGE 5. HEAT TREATED SHEAR CLIP TO 2014-T6 CONDITION, IN REF TO TRAVELER 87330820001. FABRICATSDR DALA1126459858Doubler · crackedBETWEEN LONGERONS 15L - 16L AT STA 1117 BRACKET-DOUBLER IS CRACKED. REMOVED BRACKET-DOUBLER DAMAGE AND FASTENERS ON STA 1117 BETWEEN LONGERONS 15L, 16L IAW SRM 53-03, PG 211, FORMED REPAIR C, STEP 1, 2, FABRICATED REPAIR PARTS IAW SRM 53-13-3, FIG 1, PG 5. SDR DALA1125909858Floor Panel · dentedCABIN FLOOR PANEL 92D TOP SKIN DENTED/CRACKED AT FWD END 77-05. UPPER SKIN OUT OF LIMITS DUE TO CRACK FROM PANEL EDGE, TO FASTENER HOLE, IAW SRM 53-01, PG 1, DETAIL 4. REMOVED 2 EA HAT CHANNELS IAW SRM 53-05, PGS 9-10. FABED REPAIR SKIN WITH MATERIAL 7075-T6SDR DALA1125899858Floorboard · damagedPASSENGER CABIN FLOORBOARD 71-50 CORNER IS DAMAGED. REMOVED DAMAGED AREA OF FLOORBOARD IAW SRM 53-05, PG 9, 10, MATERIAL ID SHT 7075-T6, BATCH 0001691309, FABED DOUBLER & FILLER, MATERIAL THICKNESS .032 CLAD IAW SRM 53-05, PG 10. TREATED AND PRIMED IAW INSTASDR DALA1125829858Nut Plate · corrodedPASSENGER CABIN FLOORBOARD 20-50 HAS CORROSION AND DAMAGED NUT PLATE OFF ACFT. BLENDED OUT, FOUND TO BE OUT OF LIMITS IAW SRM 53-01, PG 5 PANEL, LOCATED AND DRILLED HOLES IAW SRM 51-10-4, PG 1, TREATED AND PRIMED IAW SRM 51-10-3, PG 5-31 (ON PASSENGER CABIN FSDR DALA1123079871Cusp Web · crackedMAIN CABIN STA 712 LEFT SIDE CUSP WEB CRACKED UNDER HORSESHOE COLLAR FWD SIDE OF FRAME. CUT OUT DAMAGE IN 3.4IN X 2.4IN AND FABBED FILLER FROM .020 7075-T6 IAW DC-9 SRM 53-13-3 FIG 11. FABBED DOUBLER FROM .032 7075T6. LOCATED AND DRILLED. INSTALL DOUBLER &SDR DALA1123059878Angle · chafedVERTICAL STABILIZER REAR SPAR Z-ANGLE FOR ACCESS PANEL 6404A IS CHAFED THROUGH AT FASTENER HOLE. REMOVED DAMAGED ANGLE. RECEIVED REPAIR MATERIAL. FABRICATED, DRILLED, FITTED, TREAT & PRIME & INSTALLED IAW DC-9 SRM 51-70-5, 51-10-3, 51-30-5 & 51-31-0.SDR DALA1123049870Channel · brokenMAIN PASSENGER CABIN FLOOR PANEL 70 AFT END HAT CHANNEL BROKEN AT FASTENER HOLE. REMOVED & REPLACED 4 EA HAT CHANNELS IAW DC-9 SRM 51-30-2 & ERA 490831-14. REMOVED PREVIOUS MISDRILLED REPAIR & REPAIRED PANEL IAW DC-9 SRM 53-05 FIG 1 & 51-30-2. INSTALLED 2 ESDR DALA1123039878Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 65 HAS CORROSION AROUND EDGES. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 53-01 FIG 1 SH 3. REMOVED DAMAGE 8.5 X 21 INCHES. FABRICATED AND INSTALLED DOUBLER IAW DC-9 SRM 53-01 FIG 4 AND ER/A 489369-14.SDR DALA1123029871Floor Support · corrodedFWD WET AREA RBL-44 BETWEEN STA 170 AND 200 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW DC9 SRM 53-01 WITH AN ORIGINAL .060 IAW DC-9 SRM 53-13-01 & 51-10-1 AND A MAT LOSSOF .022. OUT OF LIMITS IAW DC9 SRM 53-01. FABBED FLOOR SUPPORT FROM EX 2652479 ISDR DALA1123019870Floor Panel · corrodedMAIN CABIN FLOOR PANEL 37 HAS CORROSION ON TOP OF PANEL. REMOVED CORR. 6X1 INCH IAW DC-9 SRM 53-01 FIG 1 AND CARD 5100-01570-01. ORIG MATERIAL .020 REMOVED .013 REMAINING MAT.007 OUT OF LIMITS. FABBED NEW PNL FROM .025 7075-T6 IAW DWG9957918 AND ERA 490827-SDR DALA1125039871Intercostal · corrodedFWD CARGO STA 218-237 INTERCOSTAL UPPER FLANGE HAS CORROSION WHERE TIE DOWN TRACK WAS REMOVED. REMOVED CORROSION, ORIG MAT .040 MAT LOSS .013 MAT. REMAINING. 027 OUT LIMITS IAW DC9 SRM 53-01. RECEIVED INTERCOSTAL FROM HEAT TREAT ON PEMCO TRAV 250N01526, LOCASDR DALA1123279878Skin · crackedDURING MCK AT DHN, THE WING LEADING EDGE SKIN AT STA 481 WAS FOUND CRACKED IN TWO PLACES UNDER AN EXISTING REPAIR WHICH HAD NOT BEEN STOP DRILLED. SECTION II - ON OR BEFORE 5,000 FLIGHT HRS AFTER SECTION I ASSOCIATED ER/A 13-490105. REMOVED PREVIOUSLY INSTALSDR DALA1123159857Outflow Valve · unresponsiveFLIGHT DIVERTED TO BUF WITH A LOSS OF CABIN PRESSURIZE. AT FL330, CABIN WAS CLIMBING 2KFT/MIN AND THE OUTFLOW VALVE SEEMED UN-RESPONSIVE. CREW COMPLIED WITH QRH PROCEDURES, DONNED MASK AND COMMENCED AN EMERGENCY DESCENT. CABIN ALTITUDE REACHED 14K BUT MASKSSDR DALA1122829878Floor Panel · chafedMAIN CABIN FLOOR PNL 90 CHAFED AT FASTENER HOLES ON FWD END OF PNL. BLENDED CHAFED AREA AND FOUND MAT TO BE OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1 SH 3. REMOVED FL/PNL 90 IAW DC-9 SRM 51-30-01. REMOVED DAMAGED AREA APPROX 8" X 21". FABBED NEW DOUBLER FROM .SDR DALA1122819878Skin · corrodedMAIN CABIN METAL SKIN FLOOR PANEL 26 HAS CORROSION ON PREVIOUS REPAIR. REMOVED CORROSION AND FOUND MAT TO BE OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1 SHT 3. FABRICATED REPAIR DOUBLER FROM .032 7075T6 IAW DC-9 SRM 51-70-4 FIG 1 ERA 490-100-14. INSTALLED PERMANESDR DALA1122809871Membrane · crackedAFT CARGO ABOVE DOOR CUTOUT AT APPROX BS 1096 PREVIOUS REPAIR MEMBRANE CRACKED AT FASTENER. REMOVED REPAIR & CUT OUT DAMAGED AREA IAW DC9 SRM 53-01 FIG 4. NDT PERFORMED IAW SPM 06-10-01.006. NO CRACKS NOTED. FABBED REPAIR & FILLER IAW DC-9 SRM 53-01 FIG 4.SDR DALA1122799871Floor Support · corrodedFWD WET AREA STA 200 BETWEEN RBL-22 AND RBL-44 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01. LOCATED AND DRILLED NEW FLOOR SUPPORT 7075T6511 .060 PER 51-10-1 FIG 2 DC9 SRM P/N 526524701 AND INSTALLED IAW DC9 SRM SDR DALA1122789870Floor Panel · crackedMAIN CABIN FLOOR PANEL 60C HAS 4EA HAT CHANNELS CRACKED ON BOTTOM OF PANEL. REMOVED 5EA HAT CHANNELS IAW SRM 51-30-2. FOUND WEB CRACKED, FABRICATED, LOCATED, DRILLED AND DEBURRED TO SKIN WITH .025 7075-T6 IAW ERA 490830-14. TRIMMED, LOCATED, DRILLED AND DEBSDR DALA1122769871Gusset · crackedMAIN CABIN AFT ENTRY DOOR JAMB RT UPPER CORNER GUSSET CRACKED AT FASTENER. REMOVED GUSSET ORG MAT .050 2014T3 IAW DRAWING 9915558-10 SUB WITH .050 7075T6 IAW SRM 51-60-1. RECEIVED MAT .050 7075T6 TRIMMED FAB DRILLED TREATED AND PRIMED INSTALLED IAW DC9 SRM 5SDR DALA1122759878Angle · corrodedMAIN PASSENGER CABIN STA 851 BL 0 L ANGLE ON TOP OF PRESSURE DECK WHEEL WELL HAS CORROSION, REMOVED CORROSION IAW DC9 SRM 53-01 FIG 1 SHT 1. ORIG MAT .125.REMOVED.045, .080 REMAINING OUT OF LIMITS. CUT OUT DAMAGED AREA 2.35 X 1. 8. FABRICATED REPAIR FILLER ASDR DALA1122749871Frame · crackedFRAME STATION 275 LT STANCHION CRACKED AT LOWER END. REPAIRED FRAME STA 275 LT STANCHION CRACKED AT LOWER END IAW DC-9 SRM 53-01 FIG 2 SHEET 4 PAGE 13 WITH 7075-T6, 0.050". TREATED AND PRIMED IAW DC-9 SRM 51-10-3. IDENTIFIED REPAIR IAW DPS 900-5-1 NO 4 RESDR DALA1122739870Frame · crackedAFT ACCESSORY COMPARTMENT CANTED FRAME 1243 IS CRACKED AT L4R. REMOVED CANTED FRAME AT STA 1243 IAW DC-9 SRM 51-30-5 AND 51-30-2. LOCATED AND DRILLED NEW FRAME P/N SR09530086-81 IAW DC9 SRM 51-10-4. INSTALLED NEW FRAME IAW DC9 SRM 51-30-5 P-102.SDR DALA1122729871Floor Support · corrodedFWD WET AREA RBL-20 BETWEEN STA 200 AND 218 FLOOR SUPPORT HAS CORROSION. FLOOR SUPPORT FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01 FABBED NEW SUPPORT OUT OF 7075T6511 IAW DRAWING 94F5481235 SHEET 2 PG 2 LOCATED & DRILLED IAW DCR9 SRM 51-10-4 TREATED & PRIMEDSDR DALA1127009858Torque Box · gougedFWD CARGO DOOR CUTOUT TORQUE BOX LWR WEB GOUGED & PUNCTURED, FS 265-270. CUT OUT DAMAGED AREA IAW SRM 53-01, PG 25, FABRICATED REPAIR DOUBLER AND FILLER, AND INSTALLED REPAIR PARTS IAW SRM 53-01, PG 25, AND SRM 53-30-05, PG 12, AND SRM 51-30-2, AT FWD CARGO SDR DALA1123909871Floor Panel · corrodedPARTS RACK ON PALLET MAIN CABIN FLOOR PANEL 66 HAS CORROSION AT EDGE. REMOVED CORROSION AT EDGE IAW DC-9 SRM 51-10-30 ORIG MAT .025 IAW DC-9 SRM 53-23-00 REMOVED .014 ONI/B EDGE .25 IN X .5 IN MAT REMOVED .011 FOUND TO BE OUT OFLIMITS IAW DC-9 SRM 53-01, RECESDR DALA1122539870Floor Panel · damagedMAIN PASSENGER CABIN FLOOR PANEL 72 TOP SKIN HOLE PUNCH CUTOUT DAMAGE IAW DC9 SRM 53-01. HFEC INSP IAW NDT SPM 06-10-01.001. NO CRACKS NOTED. FABRICATED FILLER AND DOUBLER FROM 7075-T6 .025 LOT 1120200 IAW DC9N SRM 53-01. INSTALLED FILLER AND DOUBLER IAW DSDR DALA1122459870Keelbeam · corrodedLEFT KEEL AREA STA 712 BETWEEN L29L AND L30 FRAME HAS CORROSION. REMOVED CORROSION IAW DC9 SRM 51-10-3. 100 PERCENT MATERIAL LOSS. REMOVED FRAME IAW DC-9 SRM 51-30-2. LOCATED, DRILLED AND INSTALLED NEW FRAME P/N 9957740-3 IAW DC9 SRM 51-10-4, 51-30-2 AND 51SDR DALA1129039858Skin · dentedRT HORIZ STAB ELEVATOR T/E LOWER SURFACE SKIN WITH DENT AT STA XE 213.6 OUT OF LIMITS IAW SRM 51-50-2, PAGE11, REMOVED DAMAGED AREA IAW SRM 55-03, FG 14, FABRICATED, LOCATED, AND DRILLED FINGER DOUBLERS, NEW SKIN PANEL, STRAP,SHIMS & INST ALL PARTS IAW SRM 55-SDR DALA1122609878Fitting · corrodedMAIN CABIN BETWEEN STA 693 AND 712 LONG 19 LEFT SIDE BATH TUB FITTING HAS CORROSION. FITTING FOUND TO BE OUT OF LIMITS. GAINED ACCESS TO FITTING. REMOVED CORRODED FITTING. RECEIVED, LOCATED, DRILLED AND INSTALLED NEW FITTING P/N 3913055-507 RESTORED ACCESSDR DALA1122599878Fitting · corrodedMAIN CABIN BETWEEN STA 693 AND 713 LONG 19 RIGHT SIDE BATH TUB FITTING HAS CORROSION. FITTING FOUND TO BE OUT OF LIMITS. GAINED ACCESS TO FITTING. REMOVED FITTING. RECEIVED, FIT, DRILLED AND INSTALLED NEW FITTING PART NUMBER 5913055-508. RESTORED ACCESS SDR DALA1122579851Skin · damagedFOUND FOD DAMAGE ON RIGHT SIDE OF RUDDER JUST FWD OF TOP TAB HINGE. TRIMMED OUT DAMAGE PER SRM 51-70-6 HFEC. INSPECTED CUTOUT PER NTM 06-10-01-001 DAMAGE REMOVED QC 1971. CUT OUT SIZE 1" BY 2.5'. EXTERNAL .032 2024T3 DOUBLER PER SRM 51-70-6. INSTALLED. 086SDR DALA1122569870Support Bracket · crackedMAIN CABIN STATION 200 L4L CRACKED. REMOVED L4L STA 160-228 AND 2 EA SPLICES STA 160-180 & 116-228. INTERCOSTAL SUPPORT BRACKET AND ATTACHMENT CLIP TO GO IN ACCESS. LOCATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED IAW 51-10-4, 51-20-2, 51-30-2. RESDR DALA1122489878Frame · gougedAFT ACCESSORY CANTED FRAME STA 1339 LOWER AFT SIDE GOUGED. EVALUATED GOUGE ON LT CANTED FRAME. FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01 PG 8. GAINED ACCESS, REMOVED & REPLACED LT CANTED FRAME IAW DC9 SRM 51-30-2 & 51-30-05. NEW FRAME PT 9911843-6.SDR DALA1122469878Frame · gougedAFT ACCESSORY RT SIDE CANTED FRAME STA 1339 GOUGED AT LOWER AFT SIDE. EVALUATED GOUGE RT CANTED FRAME. FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01 PG 8. GAINED ACCESS. REMOVED AND REPLACED RT CANTED FRAME IAW DC9 SRM 51-30-02, 51-30-5. NEW FRAME PT 99118SDR DALA1128309858Skin · crackedFUSELAGE LT SIDE, STA Y 130.5+Z22, EXTERNAL EXISTING REPAIR DOUBLER WITH CRACK. REMOVED DOUBLER AT LT STA 130.5+Z22 IAW SRM 51-30-5, REQ NDT FOR NO CRACKS NOTED IAW NDT PM 06-10-01. 001, RECEIVED, LOCATED, DRILLED AND PRIMED DOUBLER & INST DOUBLER, AND CONICALSDR DALA1128299858Skin · crackedFUSELAGE LT SIDE, STA Y130.5, EXTERNAL EXISTING REPAIR DOUBLER HAS CRACK. REMOVED EXTERNAL REPAIR DOUBLER AT LT IAW SRM 51-30-5, REQUESTED NDT FOR NO CRACKS NOTED IAW NDT SPM 06-10-01.001, RECEIVED, LOCATED, DRILLED, AND PRIMED EXTERNAL REPAIR DOUBLER & IN
Back to Mcdonnell Douglas DC-9-51