Mcdonnell Douglas DC-9-51

Service difficulty reports · 4,581

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'DC951'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DALA1034799855Floor Panel · damagedDURING M-CHECK FOUND CABIN FLOOR PANEL 33, DAMAGE AT FWD END CUTOUT DAMAGE 2 .1250"X 10 IAW SRM 51-70-4. FABRICATED 1EA DOUBLER IAW SRM 53-23-0 ITEM 6 FIG 4, 51-20-4, 51-10-4. ALODINED AND PRIMED IAW SRM 51-10-3 INSTALLED 1EA DOUBLER AND 1EA FILLER IAW SRM 51Dec 2, 2010 · N764NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034759853Structure · damagedDURING M-CHECK FOUND AFT ACCESSORY COMPARTMENT, LT SIDE, BETWEEN CANTED FRAMES 1275 & 1292 UNDER INBD ATTACH POINTS FOR AIRSTAIR RELEASE MOUNT FITTING. PREVIOUS REPAIR CRACKED PAST STOP DRILLS ALSO DOUBLER CRACKED. CUT OUT DAMAGED SECTION 2 FT X 2 IN. SPLICE Dec 2, 2010 · N762NC · Doug DC951 · Fuselage Main, StructureSDR DALA1034619864Floor Panel · dentedDURING M-CHECK FOUND MAIN CABIN METAL FLOOR PANEL NR39C HAS DENT. CUT OUT DAMAGED AREA 2"X 2" FABRICATED NEW FILLER AND DOUBLER IAW SRM 53-05, FIG 1. TREATED & PRIMED FILLER & DOUBLER IAW SRM 51-10-3, VERIFIED NO CRACK EXISTS. INSTALLED FILLER AND DOUBLER IADec 1, 2010 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034609864Support Splice · brokenDURING M-CHECK FOUND FWD CARGO COMPARTMENT STA 627, BETWEEN LONGERON 27R TO L28R SEAT TRACK SUPPORT SPLICE IS BROKEN. REMOVED EXISTING SPLICE.FABRICATED,HEAT TREATED, DRILLED AND INSTALLED NEW SPLICE IAW SRM 51-72-01-801-663A-A.Dec 1, 2010 · N773NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034559855Floor Panel · crackedDURING M-CHECK, FOUND CABIN FLOOR PANEL 78 CRACKED CUTOUT DAMAGE 2.5"X2" IAW SRM 53-05, FIG 1. FABRICATED FILLER AND DOUBLER IAW SRM 53-05, FIG 1. TREATED AND PRIMED INSTALLED FILLER AND DOUBLER IAW SRM 53-05, FIG 1.Dec 1, 2010 · N764NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034549853Door · corrodedDURING M-CHECK, FOUND FUSELAGE EXTERIOR AIR STAIR DOOR HAS CORROSION ALONG BOTTOM EDGE IN CHANNEL. REMOVED CORROSION FROM DOOR EDGE IN CHANNEL. FOUND TO BE OUT LIMIT IAW SRM 53-01, FIG 1 REMOVED SKIN FROM DOOR EDGE. RECEIVED NEW PN 5915064-501, INSTALLED IAWDec 1, 2010 · N762NC · Doug DC951 · Entrance StairsSDR DALA1034359853Skin · damagedDURING M-CHECK FUSELAGE EXTERIOR AFT CARGO DOOR JAMB FWD LOWER CORNER HAS ELONGATED FASTENER HOLE THRU SKIN AND INTERNAL DOUBLERS AND DOOR PAN AND PAN SPLICE HOLE CLEANED UP AT .3680 IAW SRM 51-20-03. INSTALLED FREEZE PLUG IAW SRM 51-20-03-801-663A-A.Nov 30, 2010 · N762NC · Doug DC951 · Fuselage Main, Plate/SkinSDR DALA1035009864Cusp Web · crackedDURING M-CHECK, FOUND MAIN CABIN AT LT STA 706, CUSP WEB HAS EXISTING REPAIR THAT IS CRACKED IN SEVERAL PLACES. REMOVED DOUBLER FABRICATED NEW DOUBLER, PRIMED & INSTALLED IAW SRM 51-30-02 & 53-10-16.Nov 30, 2010 · N773NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034589855Cusp Web · crackedDURING M-CHECK FOUND BS 268, RBL-55" CUSP WEB HAS 1" CRACK. REMOVED CRACK BY CUT OUT 1.3IN X .850IN CRACK CONTAINED IAW SPM 06-10-01-001. FABRICATED 1 EA DOUBLER AND 1 EA FILLER IAW SRP A-53-10-16-801-663A. TREATED AND PRIMED IAW SRM 51-10-3 INSTALLED IAW SRMNov 30, 2010 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034409864Floor Panel · corrodedDURING M-CHECK FOUND MAIN CABIN METAL FLOOR PANEL NR37 CORROSION OTBD EDGE ALONG FASTENERS. WHILE REMOVING CORROSION FOUND CRACK, CUT AWAY DAMAGE CRACKS. REMOVED DOUBLER AND FILLER FABRICATED. INSTALLED REPAIR IAW SRM 53-01, FIG 4.C.Nov 30, 2010 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034399864Floor Panel · damagedDURING M-CHECK, FOUND MAIN CABIN METAL FLOOR PNL NR38C, 1 EA FASTENER PULLING THROUGH FWD END MATERIAL CUT AWAY FOR ORIGINAL REPAIR CRACK FOUND. CUT AWAY DAMAGE. NDT VERIFIED CRACKS ALODINED AND PRIMED. DOUBLER INSTALLED IAW SRM 53-01 FIG 4C.Nov 30, 2010 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034369853Intercostal · corrodedDURING M-CHECK, FOUND FWD CARGO BETWEEN STA 218 AND 237 JUST OTBD OF LT LONG 28 INTERCOSTAL HAS CORROSION AND CRACKS APPROX 1 INCH. REMOVED CORROSION ORIGINAL MATERIAL .063. REMOVED .003 REMAIN .060 IN LIMITS IAW SRM 53-01 FIG.1 DRILLED STOP HOLE IN INTERCOSNov 30, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034109855Floor Support · corrodedDURING M-CHECK FOUND MAIN CABIN STA 290 TO 313 BL 0 FLOOR SUPPORT HAS CORROSION. REMOVED FLOOR SUPPORT FABBED FLOOR SUPPORT AND 2EA SPLICES ALODINED AND PRIMED IAW DC9 SRM 51-10-1 FIG 1 51-10-3 SRPDC9-A-53-10-03-801-663A-A. INSTALLED IAW DC9 SRM 51-30-5 & SRNov 29, 2010 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034099855Floor Panel · damagedDURING M CHECK FOUND MAIN PASENGER CABIN FLOOR PANEL 39 PREVIOUS REPAIR DISBONDED HOLE IN FLOOR. INSPECTED USING A2469 ZETEC PER NDT SPM 06-10-01. FOUND CRACKS REMOVED. FABRICATED REPAIR DOUBLER AND FILLER USING .025 7075 T6. LOCATE, DRILL, TRIM, DEBURRED, TNov 29, 2010 · N764NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034089855Floor Support · corrodedDURING M-CHECK FOUND MAIN CABIN STA 237 TO 290 BL 0 FLOOR SUPPORT HAS CORROSION. REMOVED FLOOR SUPPORT IAW DC9 SRM 51-10-1 FIG 22 & 53-12-2 FIG 4. FABBED FLOOR SUPPORT ALODINED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-30-5.Nov 29, 2010 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034069855Intercostal · crackedDURING M-CHECK FOUND MAIN CABIN FS 237-256 BL 0 INTERCOSTAL IS CRACKED AT FORWARD END RECEIVED NEW INTERCOSTAL PICKED UP HOLES & INSTALLED NUT PLATES IAW DC9 SRM 51-10-4 & 51-30-2. INSTALLED INTERCOSTAL IAW DC9 SRM 51-30-5.Nov 29, 2010 · N47717 · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034039853Doubler · crackedDURING M-CHECK FOUND CABIN/HORSE SHOE DOUBLER CRACKED FWD SIDE OF STA 712 FRAME AT CUSP WEB. REMOVED CRACKED HORSESHOE DOUBLER AT STA 712 IAW DC9 51-305. DRILLED AND DEBURRED IAW DC-9 51-10-4. INSTALLED NEW HORSESHOE DOUBLER IAW DC-9 51-30-5.Nov 29, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033959853Angle · crackedDURING M-CHECK FOUND AFT ACC COMPT STA 1209 AT L12L FRAME SHEAR ANGLE CRACKED. REMOVED 5 EA ANGLES AND CRACKED SHEAR TIE BETWEEN LONGERON 10 AND 14 RH STA 1209. FABRICATED, LOCATED, DRILLED NEW SHEAR TIE IAW SRM 51-13-4, FIG 1 AND 51-60-00 FIG.1, 51-30-2, 51-Nov 29, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033919864Floor Panel · damagedDURING M-CHECK FOUND MAIN PASSENGER CABIN FLOOR PANEL 32 HOLE IN TOP SKIN. FABBED DOUBLER AND FILLER AND INSTALLED ON CABIN FLOOR PANEL 32 ON TOP IAW DC9/MD80 SRM 51-30-2.Nov 29, 2010 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034029853Floor Panel · damagedDURING M-CHECK FOUND MAIN PASSENGER CABIN FLOOR PANEL 33 STA 351 I/B SIDE HOLE IN SKIN. REMOVED AND RECEIVED NEW FLOOR PANEL AND COUNTERSUNK ALL HOLES INSTALLED IAW DC9 SRM 51-10-4 AND SRM 51-30-1 P-130.Nov 28, 2010 · N762NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034019853Floor Panel · crackedDURING M=CHECK FOUND MAIN PASSENGER CABIN FLOOR PANEL 32 CRACKED ON FORWARD INBOARD END. REMOVED CABIN FLOOR PANEL 32. RECEIVED NEW FLOOR PANEL AND COUNTERSUNK HOLES FOR FLOOR PANEL. INSTALLED IAW DC9 SRM 51-10-4 AND 51-30-2.P-130.Nov 28, 2010 · N762NC · Doug DC951 · Fuselage Floor PanelSDR DALA1034009853Floor Support · brokenDURING M-CHECK FOUND MAIN PASSENGER CABIN FLOOR PANEL SUPPORT STA 617 LBL 22-44 IS BROKEN. FABRICATED 1 EA FLOOR SUPPORT IAW DC9 SRM 53-10-3 FIG 10. INSTALL 1EA FLOOR SUPPORT IAW DC9 SRM 51-30-2 PER DWG 59107601.Nov 28, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033939853Attach Angle · crackedDURING M-CHECK, FOUND MAIN PASSENGER CABIN APB LT NR2 FORMER FROM FLOOR LEVEL UPPER OTBD ATTACH ANGLE IS CRACKED. REMOVED CRACKED ATTACH ANGLE IAW DC-9A53-10-25-801-663A-A. FABRICATED NEW ATTACH ANGLE FROM MAT .025 6A1-4V PO1022791 IAW DWG 9915558. LOCATED, Nov 28, 2010 · N762NC · Doug DC951 · Fuselage Main, Attach FittingsSDR DALA1034119855Web · crackedDURING M-CHECK FOUND RIGHT PYLON INTERIOR WEB CRACKED IN LOWER O/B RADIUS JUST AFT OF 8TH STAGE DUCT. STOP DRILL CONTAINED CRACK IAW DC9 NDT SPM 06-10-01.001 FABRICATED AND INSTALLED 2EA. DOUBLERS AND 1EA FILLER FROM P/N 020X48X144 2024T3 S/N 0920335 & P/N .Nov 27, 2010 · N764NC · Doug DC951 · Nacelle/Pylon Miscellaneous StructureSDR DALA1034059853Hinge · gougedDURING M-CHECK FOUND LT HORIZONTAL STAB T/E NR 6 ELEVATOR HINGE GOUGED AT UPPER ATTACH POINT TO REAR SPAR. REMOVED, REPAIRED AND RE-INSTALLED IAW DC-9 MM 20-16-00 & SRM 51-10-04 & SRM 51-10-03.Nov 27, 2010 · N762NC · Doug DC951 · Horizontal Stabilizer StructureSDR DALA1034049853Cargo Track · corrodedDURING M-CHECK FOUND AFT CARGO RT TRACK HAS CORROSION AT STA 1068. RT AFT CARGO TRACK FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-05, LOCATED, DRILLED AND INSTALLED NEW CARGO TRACK IAW DC9 SRM 51-10-4 & 51-30-2.Nov 27, 2010 · N762NC · Doug DC951 · Fuselage, Seat/Cargo Attach FittingsSDR DALA1033999853Cusp Web · crackedDURING M-CHECK FOUND MAIN CABIN STA 706 LBL 50 CUSP WEB CRACKED CUT OUT DAMAGED AREA .5 X 1.5 IAW DC9 A-53-10-16-801-663A-A. CUSP WEB REMOVED AND REPLACED ON PEMCO NON ROUTINE 2281N01606 P243.Nov 27, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033989853Floor Panel · damagedDURING M-CHECK FOUND MAIN PASSENGER CABIN FLOOR PANEL 55 FORWARD END SKIN CHAFED AND TORN AROUND FASTENER HOLES. REMOVED CABIN FLOOR PANEL.RECEIVED NEW FLOOR PANEL PICKED UP AND COUNTERSUNK ALL HOLES AND INSTALLED FLOOR PANEL IAW DC9 SRM 51-10-4 AND DC-9 SRM Nov 27, 2010 · N762NC · Doug DC951 · Fuselage Floor PanelSDR DALA1033979853Floor Support · crackedDURING M-CHECK FOUND MAIN CABIN STA 655 LBL 22-42 FLOOR SUPPORT CRACKED. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT ANGLE IAW DC9 SRM 53-10-3 FIG 10 PG 19 & 51-30-2.Nov 27, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033969853Floor Panel · corrodedDURING M CHECK FOUND MAIN CABIN FLOOR PANEL 77 EXPANSION PANEL HAS CORROSION. REMOVED AND REPLACED EXPANSION CHANNEL IAW DC9 SRM 51-10-4, 51-30-2, 53-01 FIG 1 SHEET 3.Nov 27, 2010 · N762NC · Doug DC951 · Fuselage Floor PanelSDR DALA1033949853Intercostal · damagedDURING M-CHECK FOUND INTERCOSTAL BL-0 FROM STA 218-237 HAS CORROSION AND ELONGATED HOLES. REMOVED AND INSTALLED NEW INTERCOSTAL AT BL 0 BETWEEN STA 218 TO STA 237 IAW DC9 SRM 51-30-5.Nov 27, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1035429853Skin · crackedDURING M-CHECK FOUND VERTICAL STAB, TOP AFT T/E OF RUDDER IS CRACKED, RUDDER ASSY OFF 09-5541-9-9003. UPON EVALUATION VERT STAB TOP AFT T/E OF RUDDER HAS SEPARATION, NO FIBER DAMAGE INJECTED RESIN HYSOL EA 9396 CURED USING HEAT THERMOCOUPLER HT7581 APPLIED WETNov 26, 2010 · N762NC · Doug DC951 · Rudder, Plate/SkinSDR DALA1033859853Attach Angle · corrodedDURING M-CHECK FOUND AFT CARGO DOOR PAN DOOR STOP 2 EA INNER ATTACH ANGLES CORRODED. REMOVED 2 EA INNER ATTACH ANGLES FROM AFT CARGO DOOR PAN DOOR STOP IAW DC9 SRM 51-30-5. RECEIVED CUSTOMER FURNISHED PARTS.2 EA ANGLES PART#4912460-501. LOCATED, DRILLED, DEBUNov 26, 2010 · N762NC · Doug DC951 · Cargo/Baggage DoorsSDR DALA1033849853Cargo Track · corrodedDURING M-CHECK FOUND FORWARD CARGO COMPT, RT TIE DOWN TRACK CORRODED IN SEVERAL PLACES FROM STATION 218-370. REMOVED AND REPLACED TRACK. SCALLOPED TRACK IAW DRAWING NR 5932875. INSTALLED NUT PLATES ON TRACK IAW DC-9 SRM 51-30-2. INSTALLED TIE DOWN TRACK RTNov 26, 2010 · N762NC · Doug DC951 · Fuselage, Seat/Cargo Attach FittingsSDR DALA1033839853Web · crackedDURING M-CHECK FOUND LEFT PYLON INTERIOR WEB CRACKED IN O/B LOWER RADIUS JUST AFT OF 8TH STAGE DUCT. STOP DRILLED 1 INCH CRACK IAW DC-9 SRM 54-01, INSTALLED 2 EA REPAIR DOUBLERS CRACK CONTAINED IAW DC-9 NDT SPM 06-10-01-001.Nov 26, 2010 · N762NC · Doug DC951 · Nacelle/Pylon Miscellaneous StructureSDR DALA1033899863Battery · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING FOR THE CATWALK IN THE TAIL COMPARTMENT WAS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. OPERATIONAL CHECK WAS GOOD. (2010-00882)Nov 24, 2010 · N772NC · Doug DC951 · Emergency LightingSDR DALA1100829864Floor Panel · crackedAFT CARGO CTR FLOOR PANEL NR 3 HAS A CRACK IN RADIUS OF DOOR CUTOUT AREA. REMOVED CRACK BY TRIMMING AREA. NDT VERIFIED NO CRACK EXIST IAW NDT SPM 06-10-01. FABRICATED DOUBLER SEALED & INSTALLED REPAIR PARTS. ALL WORK ACCOMPLISHED IAW EA98-201837 & SRM (51-1Nov 23, 2010 · N773NC · Doug DC951 · Fuselage Floor PanelSDR DALA1036009855Frame · crackedDURING M-CHECK FOUND LT STA 756 KEEL AREA FORMER CRACKED OTBD END. TRIMMED OFF CRACKED FLANGE, FABRICATED AND INSTALLED REPAIR ANGLE IAW SRM 53-03, FIG 12, 53-13-3 FIG 2, 51-10-4, 51-10-2, 51-10-3, 51-30-2, 51-30-5.Nov 23, 2010 · N764NC · Doug DC951 · Fuselage Main, FrameSDR DALA1035489855Angle · crackedDURING M-CHECK, FOUND BS 110, BULKHEAD LBL4, 7 IN ABOVE BELLY ANGLE CRACKED. REMOVED CRACKED ANGLE IAW SRM 51-30-2. FABRICATED NEW ANGLE IAW DWG 9915600. TREATED AND PRIMED ANGLE IAW SRM 51-10-3. INSTALLED NEW ANGLE IAW SRM 51-30-5.Nov 23, 2010 · N765NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1034569855Cusp Web · crackedDURING M-CHECK FOUND MAIN CABIN STA. 762 LBL-56 CUSP WEB CRACKED. STOP DRILLED CRACK, FABRICATED REPAIR DOUBLER IAW; SRP 53-10-16-FIG 1, TREATED AND PRIMED IAW; SRM 51-10-3, INSTALLED DOUBLER IAW SRM 51-30-2.Nov 23, 2010 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033649855Floor Panel · corrodedDURING M-CHECK FOUND MAIN PASSENGER CABIN CORROSION IN SEVERAL PLACES ON FLOOR PANEL 63. CUT OUT DAMAGED AREA 1.5 SQ IN NDT VERIFIED DAMAGE REMOVAL IAW NDT SPM 06-10-01. FABRICATED & INSTALLED FILLER & DOUBLER FROM7075-T6 .020 THICK PO 1022528 IAW DC9 SRM 53Nov 23, 2010 · N764NC · Doug DC951 · Fuselage Floor PanelSDR DALA1033639855Membrane · chafedDURING M-CHECK FOUND MAIN CABIN STA 200 RBL 4 TO RBL 17 SUB-FLOOR CHAFED IN SEVERAL PLACES. BLENDED CHAFE AREAS 1"X 2" 3 EA PLES ORIG MAT .020 REMOVED .015 REMAINING .005. FOUND TO BE OUT OF LIMITS. CUT OUT DAMAGE 5 1/2"X 13". DVI WITH 5X MAGNIFY GLASS. VENov 23, 2010 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033629855Membrane · chafedDURING M-CHECK FOUND MAIN CABIN STA 200 TO 218 AND BL 0 TO LBL 20 SUB-FLOOR CHAFED SEVERAL PLACES. BLENDED CHAFE AREAS 1"X 2" 4 EA PLACES.ORIGINAL .020 REMOVED.008 REMAINING .012.FOUND TO BE OUT OF LIMITS FABRICATED AND INSTALLED FILLER .020 7075-T6 PO 10225 Nov 23, 2010 · N764NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033619855Seat Track · gougedDURING M-CHECK FOUND MAIN CABIN FS 817 - RBL 44 -SEAT TRACK IS GOUGED BEYOND LIMITS FITTED AND DRILLED NEW SUBSTITUTE CHANNEL INTO SEAT TRACK AT FS 817 RBL 44 IAW DC9 SRM 53-05 FIG 4A. TREAT IAW DC9 SRM 51-10-3 PRIMED CHANNEL IAW DC9 SRM 51-10-3. INSTALLED NNov 23, 2010 · N764NC · Doug DC951 · Fuselage, Seat/Cargo Attach FittingsSDR DALA1033599853Frame · crackedDURING M-CHECK PER AD-FAR MAIN CABIN STA 712 LT MAIN FRAME IS CRACKED INRADIUS BELOW FLOOR. REPAIR PRIOR TO FURTHER FLIGHT REPAIR REQUIRES REQUIRES FAA MANAGER LOS ANGELES ACO APPROVAL PRIOR TO FLIGHT. MUST BE REPORTED ON SSI FORM 5100-3201. REF EM 5320-010Nov 23, 2010 · N762NC · Doug DC951 · Fuselage Main, FrameSDR DALA1033589853Frame · gougedDURING M-CHECK, FOUND AFT ACCESSORY COMPARTMENT RT SIDE CANTED STA 1243, BETWEEN STRINGER 13-14, FRAME GOUGED ON BOTH SIDES COMPLETELY THROUGH. RT CANTED FRAME STA 1243 BETWEEN STR 13-14 CUTOUT DAMAGE 2" X 1" NDT HFEC VERIFIED DAMAGED REMOVED IAW NDT SPM 06-10Nov 23, 2010 · N762NC · Doug DC951 · Fuselage Main, FrameSDR DALA1033579853Bulkhead · crackedDURING M-CHECK AND IAW AD-FAR AFT ACCY COMPARTMENT-AFT PRESSURE BULKHEAD RT LOWER CORNER HAS CRACK IN 5910130-85 GUSSET AND 5910130-87 DOUBLER, JUST ABOVE -37 SEAL CHANNEL. NDT VERIFIED CRACK STOPS ABOVE -37 SILL CHANNEL USING A2469 ZETEC IAW NDT SPM 06-10-01.Nov 23, 2010 · N762NC · Doug DC951 · Fuselage Main, BulkheadSDR DALA1033569853Intercostal · crackedDURING M-CHECK FOUND FUSELAGE EXTERIOR BETWEEN WHEEL WELL DOORS STA 792 RBL 10 INTERCOSTAL CRACKED. REMOVED INTERCOSTAL IAW DC9 SRM 51-30-5 FABRICATED, LOCATED, DRILLED, DEBURRED, TREATED, PRIMED, SEALED & INSTALLED INTERCOSTAL IAW BOEING DRAWING 9923459 REV Nov 23, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033559853Intercostal · corrodedDURING M-CHECK FOUND FUSELAGE EXTERIOR-STA 837 INTERCOSTAL BETWEEN MLG DOORS CORRODED. REMOVED INTERCOSTAL AT STA 837 B/W MLG DOORS PER SRM 51-30-2 & 51-30-5. FORMED, LOCATED, DRILLED, DEBURRED, TREATED, PRIMED, INSTALLED IAW DOUGLAS DWG 9923459 REV AE & DC9Nov 23, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous StructureSDR DALA1033549853Floor Support · corrodedDURING M-CHECK FOUND MAIN PASSENGER CABIN STA 218-237 BL 0 FLOOR SUPPORT HAS CORROSION. FABRICATED NEW FLOOR SUPPORT TREATED PRIMED IAW DC9 SRM 51-10-3 AND 51-10-4 INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-30-5.Nov 23, 2010 · N762NC · Doug DC951 · Fuselage Miscellaneous Structure
Back to Mcdonnell Douglas DC-9-51