Mcdonnell Douglas MD-11
Service difficulty reports · 7,956
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 05FDEA01975Hinge · corrodedRT WING, O/B FLAP I/B HINGE (WING SIDE), SIDE LINK ATTACHMENT SPOT FACE FOUND CORRODED.SDR 05FDEA01974Hinge · corrodedRT WING-O/B FLAP I/B HINGE (WING SIDE), LWR ATTACHMENT SPOT FACE FOUND CORRODED. CORROSION REMOVED AS PER CMM 57-44-08 PG 602-607. REPAIR CARRIED OUT AS PER CMM 57-44-08.SDR 05FDEA01973Hinge · corrodedRT WING-O/B FLAP I/B HINGE (WING SIDE), ACTUATOR ATTACHMENT O/B BORE FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-08 PG 602-607. FABRICATED BUSHING AND INSTALLED AS PER EA 1-5750-87610. (CLOSED)SDR 05FDEA01960Seat Track · crackedMAIN DECK CARGO COMPARTMENT, FLOOR SEAT TRACK AT STA 635, X= - 8.5 FOUND CRACKED APPROXIMATELY 3 INCHES LONG. REPAIRED AS PER SRM 53-70-00 VOLUME I, FIGURE 1. REPAIR CLASSIFID AS MAJOR PER GMM 6-2-100.SDR 05FDEA01961Seat Track · crackedMAIN DECK CARGO COMPARTMENT, FLOOR SEAT TRACK AT STA 635, X= -27 FOUND WITH CRACKED APPROXIMATELY 3 INCHES LONG. REPAIRED AS PER SRM 53-70-00 VOLUME I, FIGURE 1. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.SDR 05FDEA01959Seat Track · crackedMAIN DECK CARGO COMPARTMENT, FLOOR SEAT TRACK AT STA 635, X= 47 FOUND CRACKED APPROXIMATELY 3 INCHES LONG. REPAIRED AS PER SRM 53-70-00 VOLUME I, FIGURE 1. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100SDR 05FDEA01958Web · tornCENTER CARGO COMPARTMENT, FOUND FLOOR LEVEL WEB TORN AT STA 1841, RBL 1. TRIMMED OUT , REPAIR DOUBLERS FABRICATED AND INSTALLED IAW SRM 53-00-01 FIG. 10 VOL. I. THIS REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100.SDR 05FDEA01957Skin · crackedLEFT WING, FORWARD FIXED LEADING EDGE INNER SKIN FOUND CRACKED, ADJACENT TO REFUELING PANEL AT STA 530. FABRICATED REPAIR DOUBLER AS PER SRM 57-10-00 FIG. 25 VOL.I AND INSTALLED REPAIR DOUBLER AT LT WING FORWARD FIXED LEADING EDGE INNER SKIN, ADJACENT TO REFUSDR 05FDEA01956Skin · crackedLT WING FORWARD FIXED LEADING EDGE INNER SKIN FOUND CRACKED, ADJACENT TO REFUELING PANEL AT STA 522. FABRICATED REPAIR DOUBLER AS PER SRM 57-10-00 FIGURE 25 VOLUME I AND INSTALLED REPAIR DOUBLER AT LEFT HAND WING FORWARD LEADING EDGE INNER SKIN, ADJACENT TO RSDR 05FDEA01955Skin · crackedLEFT WING, FORWARD FIXED LEADING EDGE INNER SKIN FOUND CRACKED, ADJACENT TO REFUELING PANEL AT STA 512. FABRICATED REPAIR DOUBLER AS PER SRM 57-10-00 FIG. 25 VOL.I AND INSTALLED REPAIR DOUBLER AT LH WING FORWARD FIXED LEADING EDGE INNER SKIN, ADJACENT TO SDR 05FDEA01954Skin · crackedLEFT WING, FORWARD FIXED LEADING EDGE INNER SKIN FOUND CRACKED, ADJACENT TO NR 4 SLAT STA 540. FABRICATED REPAIR DOUBLER AS PER SRM 57-10-00 FIG. 25 VOL.I AND INSTALLED REPAIR DOUBLER AT LH WING FORWARD FIXED LEADING EDGE INNER SKIN ADJACENT TO NR 4 SLAT STSDR 05FDEA01953Skin · crackedLEFTWING, FORWARD FIXED LEADING EDGE INNER SKIN FOUND CRACKED, ADJACENT TO NR 5 SLAT STA 590 TO STA 600. FABRICATED REPAIR DOUBLER AS PER SRM 57-10-00 FIG. 25 VOL.I AND INSTALLED REPAIR DOUBLER AT LH WING FORWARD FIXED LEADING EDGE INNER SKIN ADJACENT TSDR UPS05M44909Landing Gear · malfunctionedNOSE GEAR DOES NOT LOCK IN UP POS. INSPECTED NOSE GEAR LINKAGES, DOORS WHEEL WELL AND NOSE WHEEL STEERING NIL DEFECTS FOUND. JACKED A/C PER MD11 AMM 07-11-00-2 AND ILLEG NOSE GEAR PER AMM 32-30-00 FOUND NORMAL.SDR UPS05M44908Landing Gear · malfunctionedNOSE GEAR DOES NOT LOCK IN UP POS. INSPECTED NOSE GEAR AND SHER WELL. NIL DAMAGE NOTED ALL LINKAGE CHK'D AND LUBED. NOSE WHEEL OPERATING OPS NORMAL PER KD-11 AMM 32-50-00 PSEU TEST IN PRIMARY AND ALT ILLE PER MD AMM 32-60-00SDR 05FDEA01941Seat Track · elongatedMAIN DECK CARGO COMPARTMENT, FLOOR SEAT TRACK CROWN AT STA 645, X= -47 FOUND ELONGATED.SDR 05FDEA01940Hinge · corrodedRT WING, O/B FLAP O/B HINGE (WING SIDE), SIDE LINK ATTACHMENT SPOT FACE FOUND CORRODED. CORROSION REMOVED IAW CMM 57-44-09 PG 402-407.SDR 05FDEA01939Hinge · corrodedRT WING , O/B FLAP O/B HINGE (WING SIDE), SIDE LINK ATTACHMENT BARREL NUT BORE FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. FABRICATED BUSHING AND INSTALLED AS PER EA 1-5750-87608.SDR 05FDEA01938Hinge · corrodedRT WING, O/B FLAP O/B HINGE (WING SIDE), ACTUATOR ATTACHMENT O/B BORE, FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09 PG 402-407. FABRICATED BUSHING AND INSTALLED AS PER EA 1-5750-87608.SDR 05FDEA01937Hinge · corrodedRT WING, O/B FLAP O/B HINGE (WING SIDE), ACTUATOR ATTACHMENT I/B BORE FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09 PG 402-407. FABRICATED BUSHING AND INSTALLED AS PER EA 1-5750-87609.SDR 05FDEA01936Floorbeam · corrodedAT STA 1964 LBL 10 FLOOR SUPPORT STRUCTURE FOUND CORRODED. FLOOR SUPPORT REMOVED. NEW FLOOR SUPPORT REWORKED FROM S2929169X7075T6511 AS PER DRAWING AGA 7091 AND INSTALLED AS PER SRM 51-31-01 VOL II. CLASSIFIED MINOR REPAIR AS PER GMM 6-2-100.SDR 05FDEA01935Floorbeam · corrodedCABIN, ALONG STA 1887 TO 2007 RBL 19 FLOOR SUPPORT STRUCTURE FOUND CORRODED. FLOOR SUPPORT REMOVED AND REWORKED.SDR 05FDEA01934Floorbeam · corrodedCABIN, AT STA 1887 ALONG RBL 60 TO RBL 88 FLOORBEAM STRUCTURE FOUND CORRODED.SDR 05FDEA01933Floorbeam · brokenCABIN, AT STA 1986 RBL 61 FLOORBEAM STRUCTURE FOUND BROKEN. DISPREPANT FLOOR SUPPORT REMOVED. NEW FLOOOR SUPPORT REWORKED FROM S2929169X7075T6511 AS PER DRAWING AGA 7091 AND INSTALLED AS PER SRM 51-31-01 VOL II. CLASSIFIED AS MINOR AS PER GMM 6-2-100.SDR 05FDEA01932Floor Support · corrodedCABIN, AT STA 1908 ALONG LBL 60 TO LBL 86.5 FLOOR SUPPORT STRUCTURE FOUND CORRODED. SUPPORT REMOVED AND REPLACED.SDR 05FDEA01931Floorbeam · corrodedCABIN AT STA 1887 RBL 35 FLOORBEAM STRUCTURE FOUND CORRODED. CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21-01 VOL II. MATERIAL THK: 0.080" ,THK REMAINED: 0.072" AND MATERIAL REMOVED: 0.008" FOUND WITHIN LIMIT AS PER SRM 53-00-01 FIG 4 VOL I. REWOSDR 05FDEA01930Floor Support · corrodedCABIN, AT STA 1887 RBL 30.5 FLOOR SUPPORT STRUCTURE FOUND CORRODED. CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21-01 VOL II. MATERIAL THK 0.070", MATERIAL REMAINED 0.063" AND MATERIAL REMOVED 0.007" FOUND WITHIN LIMIT AS PER SRM 53-00-01 FIG 1A VSDR 05FDEA01929Floor Support · corrodedCABIN, AT STA 2003 RBL 57 FLOOR SUPPORT STRUCTURE FOUND CORRODED. CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21-01SDR 05FDEA01901Skin · crackedRT WING, LEADING EDGE SKIN AT STA XORS 797 FOUND WITH 17 IN CRACKED. REPAIR CARRIED OUT AS PER SRM 57-10-00 VOLUME I, FIGURE 37.SDR 05FDEA01915Floor Support · corrodedCABIN STA 1887 RBL 54 FLOOR SUPPORT STRUCTURE FOUND CORRODED. CORROSION REMOVED AND REPROTECTED AS PER SRM 51-21-01 VOL II. MATERIAL THK: 0.125", MATERIAL REMAINED: 0.113" AND MATERIAL REMOVED: 0.012" FOUND WITHIN LIMIT AS PER SRM 53-00-01 FIG 4 VOL I. SDR 05FDEA01914Floor Support · corrodedCABIN, AT STA 1887 ALONG RBL 38.5 TO RBL 53.5 FLOOR SUPPORT STRUCTURE FOUND CORRODED. SUPPORT REPLACED AS PER DWG AGA8027 AND SRM 51-31-01 VOL2.SDR 05FDEA01913Floorbeam · corrodedCABIN, AT STA 1986 ALONG LBL 1 TO LBL 19 FLOOR SUPPORT STRUCTURE FOUND CORRODED.SDR 05FDEA01912Floorbeam · corrodedAT STA 1836 ALONG LBL 10.5 TO LBL 26 FLOOR SUPPORT STRUCTURE FOUND CORRODED. FLOOR SUPPORT REMOVED. NEW FLOOR SUPPORT REWORKED FROM S2929348X7075T6511 AS PER DRAWING AGA 7975 AND INSTALLED AS PER SRM 51-31-01 VOL.II. CLASSIFIED MINOR REPAIR AS PER GMM 6-SDR 05FDEA01911Floorbeam · corrodedAT STA 1821 ALONG LBL 10 TO LBL 25.5 FLOORBEAM STRUCTURE FOUND CORRODED. DISCREPANT FLOOR SUPPORT REMOVED, NEW FLOOR SUPPORT REWORKED FROM S2929169X7075T6511 AS PER DRAWING AGA 3814 AND INSTALLED AS PER SRM 51-31-01 VOL II. CLASSIFIED MINOR AS PER GMM 6SDR 05FDEA01910Floorbeam · corrodedAT STA 1821 ALONG LBL 38.5 TO LBL 65 FLOORBEAM STRUCTURE FOUND CORRODED. REMOVED AND REPLACED. NEW FLOOR SUPPORT REWORKED IAW DWG AGA 7028. NEW SUPPORT PAINTED, PART MARKED AND INSTALLED IAW SRM 51-35-01 VOL.II. CLASSIFIED MINOR REPAIR AS PER GMM 6-2-100.SDR 05FDEA01909Hinge · corrodedLT WING - I/B FLAP O/B HINGE (FLAP SIDE ), PIVOT PIN ATTACHMENT I/B BORE FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-52-03 PG 442-443. FABRICATED BUSHING AND INSTALLED AS PER EA 1-5750-87606.SDR 05FDEA01908Hinge · corrodedLT WING-O/B FLAP I/B HINGE (WING SIDE), SIDE LINK ATTACHMENT SPOT FACE FOUND CORRODED. CORROSION REMOVED AS PER CMM 57-44-08 PG 612-615.SDR 05FDEA01907Hinge · corrodedLT WING-O/B FLAP I/B HINGE (WING SIDE), LWR ATTACHMENT SPOT FACE FOUND CORRODED. REPAIR CARRIED OUT IAW EA 1-5750-87605.SDR 05FDEA01906Hinge · corrodedLT WING-O/B FLAP I/B HINGE (WING SIDE), FWD ATTACHMENT O/B BORE FOUND CORRODED. REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-08. FABRICATED BUSHING AND INSTALLED IAW EA 1-5750-87605.SDR 05FDEA01905Hinge · corrodedLT WING-O/B FLAP I/B HINGE (WING SIDE), ACTUATOR ATTACHMENT O/B BORE FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-08 PG 602-607. FABRICATED BUSHING AND INSTALLED AS PER EA 1-5750-87605.SDR 05FDEA01904Hinge · corrodedLEFT WING-O/B FLAP I/B HINGE (WING SIDE), ACTUATOR ATTACHMENT I/B HOLE SPOT FACE FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-08 PG 602-607. REPAIR CARRIED OUT AS PER EA 1-5750-87605.SDR 05FDEA01903Hinge · corrodedLT WING-O/B FLAP I/B HINGE (WING SIDE), ACTUATOR ATTACHMENT I/B BORE FOUND CORRODED. CORROSION REMOVED AND FOUND EXCEED LIMIT AS PER CMM 57-44-08 PG 602-607. FABRICATED BUSHING AND INSTALLED AS PER EA 1-5750-87605.SDR 05FDEA01902Skin · dentedRT I/B FLAP UPPER SKIN BETWEEN XIFN 151.300 TO 159.300, FOUND WITH EXISTING DENTS, 3 PLACES, AS MARKED. DENT AREA TRIMMED AND REPAIR DOUBLER FABRICATED AND MATERIAL USED AS PER SRM 57-10-00 FIG 34 VOL I AND DRAWING ARC 2740. REPAIR DOUBLER INSTALLED AS PER SRSDR 05FDEA01900Hinge Fitting · wornUPON REMOVAL OF LT MLG WHEEL WELL DOOR, FOUND AFT HINGE FITTING WORN. REMOVED AND REPLACED AS PER SRM 51-35-01 VOLUME II. THIS REPAIR IS CLASSIFIED MINOR PER GMM 6-2-100.SDR 05FDEA01896Hinge · crackedLT MLG WHEEL WELL DOOR CENTER HINGE HALVES FOUND CRACKED. CRACKED CENTER HINGE AT LEFT HAND MAIN LANDING GEAR WHEEL WELL DOOR REMOVED AND REPLACED WITH NEW HINGE AS PER SRM 51-35-01 VOLUME II. THIS REPAIR IS CLASSIFIED MINOR PER GMM 6-2-100.SDR 05FDEA01895Splice · damagedCENTER CARGO BAY RT STA 5-113, LONGERON 44 SPLICE FITTING FOUND WITH EXISTING ENLONGATED HOLE AFTER REMOVAL SPLICE FITTING. REMOVED AND REPLACED NEW SPLICE FITTING AS PER SRM 51-33-01 VOL. II. MINOR REPAIR AS GMM 6-2-100.SDR 05FDEA01894Hinge · corrodedLT WING O/B FLAP O/B HINGE (WING SIDE), SIDE LINK ATTACHMENT SPOT FACE FOUND CORRODED. CORROSION REMOVED AS PER CMM 57-44-09 PG 402-407. REPAIR CARRIED OUT AS PER CMM 57-44-09.SDR 05FDEA01890Hinge · corrodedLT WING, O/B FLAP O/B HINGE (WING SIDE), ACTUATOR ATTACHMENT O/B BORE FOUND CORRODED. REPAIRED AS PER CMM 57-44-09 P402-407 AND EA 1-5750-87592A.SDR 05FDEA01889Hinge · corrodedLT WING, O/B FLAP O/B HINGE (WING SIDE), ACTUATOR ATTACHMENT I/B BORE FOUND CORRODED. REPAIRED AS PER EA1-5750-87592A.SDR 05FDEA01888Stringer · damagedAFT CARGO BAY AT STA 1967, AFT CENTER CEILING TOP STRINGER ASSY FOUND DAMAGED AS MARKED. DAMAGED FLOOR SUPPORT REMOVED. NEW FLOOR SUPPORT REWORKED FROM S2922781- 1X2024T42 AS PER DWG ACA 7149 AND INSTALLED AS PER SRM 51-31-01 VOL.II. CLASSIFIED MINOR REPAISDR 05FDEA01887Bracket · corrodedAFT CARGO BAY STA 1841 LOWER FRAME FWD FLOOR PANEL SUPPORTING BRACKET FOUND CORRODED AS MARKED. AFT CARGO COMPARTMENT, STA 1841 LOWER FRAME FWD FLOOR PANEL SUPPORTING BRACKET REMOVED AS PER SRM 51-33-01 VOL II. NEW STIFFENER FABRICATED AS PER DRAWING AGA
Back to Mcdonnell Douglas MD-11