Mcdonnell Douglas MD 83

Service difficulty reports · 3,415

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD83'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR WX0A070235Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOSep 19, 2008 · N892GA · Doug MD83 · Emergency LightingSDR WX0A070233Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MAINT REPORTED A PROTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLSep 4, 2008 · N892GA · Doug MD83 · Emergency LightingSDR ANC2008F00002Display · inoperativeAIR TURN BACK, AFTER LIFT OFF CAPT AND F/O PRIMARY DISPLAY AND NAV DISPLAY WENT BLANK, AIRSPEED INDICATOR, ALTIMETER SHOWED FLAGS. GONE AHRS DISPLAYED. CAPT`S VSI AND CAPT`S RMI SHOW HDG FLAG AND VSI AND RA FLAGS. FTR AND RTS WERE ACCOMPLISHED AT BOTH DFGC SHSep 1, 2008 · N583AN · Doug MD83 · Central DisplaySDR WXO2008F00008Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK, INSP REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAIN REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHEAug 28, 2008 · N892GA · Doug MD83 · Emergency LightingSDR ANC2008F00001Link · unknownAIR TURN BACK. WHEN LANDING GEAR HANDLE WAS MOVED UP AFTER TAKEOFF, A VERY STRONG VIBRATION WAS FELT ON THE NOSE LANDING GEAR. REMOVED AND REPLACED RT FWD DOOR LINK IAW AMM 32-22-01, PAGE 201. OPS CHECK OK. PN 39567851, SN OFF EFS26043. SN ON LIN5301. (K)Aug 28, 2008 · Doug MD83 · Landing Gear DoorsSDR DUR42008238BLongeron · damagedACFT ARRIVED WITH RAMP DAMAGE TO THE FUSELAGE SKIN AND STRUCTURE AT FS 148 LONGERON 22L, AND SHEAR TIE. (S)Aug 22, 2008 · N874GA · Doug MD83 · Fuselage Main, Longeron/StringerSDR DU4R2008238ASkin · damagedACFT ARRIVED, WITH RAMP DAMAGE TO THE FUSELAGE SKIN AND STRUCTURE AT FS 148 LONGERON 22L, AND SHEAR TIE. (S)Aug 22, 2008 · N874GA · Doug MD83 · Fuselage Main, Plate/SkinSDR DU4R2008238Shear Tie · damagedACFT ARRIVED, WITH RAMP DAMAGE TO THE FUSELAGE SKIN AND STRUCTURE AT FS 148 LONGERON 22L, AND SHEAR TIE. (S)Aug 22, 2008 · N874GA · Doug MD83 · Fuselage Internal Mounting StructureSDR 2008FA0000568Longeron · damagedDURING SCHEDULED REPAIR, MISDRILLED 3 EACH HOLES AT FS 150 AND 3 INCHES BELOW LONGERON 23L. (S)Aug 22, 2008 · N874GA · Doug MD83 · Fuselage Main, Longeron/StringerSDR 2008FA0000567Longeron · damagedDURING SCHEDULED REPAIR, FOUND DOUBLE DRILLED ON LONGERON 23L AT FS 154.5. (S)Aug 22, 2008 · N874GA · Doug MD83 · Fuselage Main, Longeron/StringerSDR WXO2008F00004Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAug 17, 2008 · N892GA · Doug MD83 · Emergency LightingSDR WXO2008F00002Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK, INSPECTION REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFACTORY OPERATIONAL CHECK WAS ACCAug 13, 2008 · N872GA · Doug MD83 · Emergency LightingSDR AALA200802080Light · inoperativeLGA EXTERIOR EMERGENCY LIGHT AT AFT RT HAND INOPERATIVE. REPLACED LAMP FOR EXTERIOR EMERGENCY LIGHT AT RT HAND AFT. SYSTEM GROUND CHECKED NORMAL OPS.Aug 12, 2008 · N951TW · Doug MD83 · Emergency LightingSDR AALA200802081Light · inoperativeLGA EMERGENCY LIGHT AT SEAT 11D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 11D. SYSTEM GROUND CHECKED NORMAL OPS.Aug 12, 2008 · N951TW · Doug MD83 · Emergency LightingSDR AALA200802082Light · missingLGA EMERGENCY LIGHT AT SEAT 5E MISSING LAMP. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 5E. SYSTEM GROUND CHECKED NORMAL OPS.Aug 12, 2008 · N951TW · Doug MD83 · Emergency LightingSDR AALA200802083Lens · missingLGA EMERGENCY LIGHT AT SEAT 5E MISSING LENS. REPLACED LENS FOR EMERGENCY LIGHT AT SEAT 5E. SYSTEM GROUND CHECKED NORMAL OPS.Aug 12, 2008 · N951TW · Doug MD83 · Emergency LightingSDR WX0A070220Battery · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MX DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MX PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFAJul 19, 2008 · N872GA · Doug MD83 · Emergency LightingSDR WX0A070218Battery · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MX DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MX PERSONNEL REMOVED AND REPLACED THE APPROPRIATE BATTERIES IN THE POWER SUPPLY BATTERY PACK. A SATISFAJul 8, 2008 · N872GA · Doug MD83 · Emergency LightingSDR AALA200801753Connector · looseSFO - EMERGENCY LIGHT AT SEAT ROW 27D INOPERATIVE. SECURED CONNECTOR FOR EMERGENCY LIGHT AT SEAT ROW 27D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)Jul 1, 2008 · N9412W · Doug MD83 · Light System WiringSDR AALA200801752Connector · looseSFO - EMERGENCY LIGHT AT SEAT ROW 9D INOPERATIVE. SECURED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 9D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)Jul 1, 2008 · N9412W · Doug MD83 · Light System WiringSDR AALA200801652Wire · brokenSFO - EMERGENCY LIGHT AT SEAT 14D INOPERATIVE. REPAIRED BROKEN WIRE FOR EMERGENCY LIGHT AT SEAT 14D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)Jun 7, 2008 · N9412W · Doug MD83 · Light System WiringSDR WXOA070204Battery Pack · failedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFMay 27, 2008 · N872GA · Doug MD83 · Emergency LightingSDR AALA200801364Battery Pack · dischargedSFO - EMERGENCY LIGHTS AT OVERHEAD SEAT 25D AFT TO TAIL CONE INOPERATIVE. CHARGED BATTERY PACK FOR EMERGENCY LIGHT AT OVERHEAD SEAT 25D AFT TO TAIL CONE. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)May 22, 2008 · N9413T · Doug MD83 · Emergency LightingSDR AALA200801363Connector · brokenSFO - EMERGENCY LIGHT AT SEAT 14D INOPERATIVE. REPLACED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 14D. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)May 22, 2008 · N9413T · Doug MD83 · Light System WiringSDR FE5F200800001Spar · corrodedFOUND LT WING REAR SPAR HAS CORROSION MARKS AT STA 367-361 C (EO) (L-5.875 IN,W-0.875 IN,D-0.125 IN).Apr 22, 2008 · N28035 · Doug MD83 · Wing SparSDR AALA200800744Oven · dirtyEWR INFLIGHT T1905/29MAR - DURING CLIMB FLIGHT ATTENDANT REPORTED OUTBOARD GALLEY OVEN SMOKING AND OVERHEATING. RETURNED TO EWR AND LANDED WITHOUT INCIDENT. FOUND PLASTIC WRAP MELTED ON RACK IN OVEN. REMOVED OVEN RACK AND COLLARED CIRCUIT BREAKER AND PLACARMar 29, 2008 · N951TW · Doug MD83 · Buffet/GalleysSDR AALA200800735Lamp · inoperativePHX - EMERGENCY LIGHT AT SEAT 19D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 19D. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 27, 2008 · N951TW · Doug MD83 · Emergency LightingSDR AALA200800734Lamp · inoperativePHX - EMERGENCY LIGHT AT SEAT 7D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT SEAT 7D. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 27, 2008 · N951TW · Doug MD83 · Emergency LightingSDR 070189Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE DEPARTMENT PERSONNEL REPORTED THE RIGHT AND LEFT OVER WING EXIT LIGHT, FWD EMERGENCY EXIT DOOR (L1)AND THE LEFT FWD FLOOR EMERGENCY EXIT LIGHT INOP WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED Mar 19, 2008 · N892GA · Doug MD83 · Emergency LightingSDR AALA200800500Battery Pack · out of adjustLGA - EMERGENCY LIGHTS AT FIRST CLASS ENTRY INOPERATIVE. ADJUSTED CONTACTS IN BATTERY PACK FOR EMERGENCY LIGHTS AT FIRST CLASS ENTRY. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 4, 2008 · N951TW · Doug MD83 · Emergency LightingSDR AALA200800499Battery Pack · inoperativeLGA - AISLE FLIGHT ATTENDANT EMERGENCY FLASHLIGHT AT GALLEY INOPERATIVE. REPLACED BATTERIES FOR EMERGENCY FLASHLIGHT AT GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 4, 2008 · N951TW · Doug MD83 · Emergency EquipmentSDR AALA200800502Lamp · inoperativeLGA - EMERGENCY LIGHT AT OVERHEAD SEAT 26D INOPERATIVE. REPLACED LAMP FOR EMERGENCY LIGHT AT OVERHEAD SEAT 26D. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 4, 2008 · N951TW · Doug MD83 · Emergency LightingSDR AALA200800501Wire · brokenLGA - EMERGENCY LIGHT AT SEAT 13D INOPERATIVE. REPAIRED BROKEN WIRE FOR EMERGENCY LIGHT AT SEAT 13D. SYSTEM GROUND CHECKED NORMAL OPERATION.Mar 4, 2008 · N951TW · Doug MD83 · Light System WiringSDR AALA200800422Battery Pack · inoperativeLAX - OVERWING EXTERIOR EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK AT B5 125 FOR OVERWING EXTERIOR EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.Feb 27, 2008 · N9413T · Doug MD83 · Emergency LightingSDR AALA200800261Battery Pack · inoperativeLGA - EMERGENCY LIGHT AT AFT OVERWING EXIT SIGN INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY LIGHT AT AFT OVERWING EXIT SIGN. SYSTEM GROUND CHECKED NORMAL OPERATION.Feb 7, 2008 · N9630A · Doug MD83 · Emergency LightingSDR AALA200800262Battery Pack · inoperativeLGA - EMERGENCY LIGHTS AT FORWARD GALLEY INOPERATIVE. REPLACED BATTERY PACK FOR EMERGENCY EXIT LIGHTS AT FORWARD GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.Feb 7, 2008 · N9630A · Doug MD83 · Emergency LightingSDR WX0A070184Battery Pack · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFDec 30, 2007 · N881GA · Doug MD83 · Emergency LightingSDR 070180A/C Pack · smokeFLIGHT 603 FROM BLI, THE FLIGHT CREW DETECTED SMOKE IN THE CABIN, DECLARED AN EMERGENCY AND RETURN TO BLI. ON CALL MX PERSONNEL WERE DISPATCHED TO THE ACFT BY MX CONTROLLER. AIR CONDITIONING SYSTEM WAS INSPECTED AND IT WAS DETERMINED THAT THE LT AIR CONDITIDec 30, 2007 · N865GA · Doug MD83 · Cabin Cooling SystemSDR 070181Fuel Control · leakingFLIGHT 705 AT GSP (GREENVILLE,SC), FLIGHT CREW REPORTED DURING TAXI TO THE GATE UPON APU START THE SMELL OF FUEL AND SMOKE FILLED THE CABIN. ON CALL MTX INSPECTED THE AIRCRAFT AND APU AND DETERMINE THAT THE FUEL CONTROL WAS LEAKING FUEL INTO THE AIR DUCT. APDec 28, 2007 · N892GA · Doug MD83 · APU Engine Fuel and ControlSDR 070183Battery Pack · no testDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFDec 18, 2007 · N883GA · Doug MD83 · Emergency LightingSDR ANCF200700030Warning System · false activationDURING ROLL T/O FLAPS CONFIGURATION ALARM SOUNDS WITH THE FLAPS T/O SELECTOR IN TO POSITION AT 60 KTS. IAW AMM 27-53-01 PAG 201. FLAPS WARNING SWITCH CHECK AND TEST WERE EFECTUATED. FAULT NOT DUPLICATED.Dec 4, 2007 · N632CT · Doug MD83 · Central WarningSDR ASMF200711002Engine · failedAIRCRAFT REJECTED TAKEOFF AT 130 KNOTS DUE TO RT ENGINE HAS LOSS OF POWER AND BRAKES REACHED 350 DEGREE C. DURING MAINTENANCE CHECK, T4 STAGE WAS DETECTED WITH LOSS OF MATERIAL, THEREFORE, RT ENGINE WAS REPLACED AND TESTED IAW MPSM 71-00-02 AND 71-00-01. HIGH Nov 13, 2007 · N838AM · Doug MD83 · Engine (Turbine/Turboprop)SDR 070178Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFNov 9, 2007 · N892GA · Doug MD83 · Emergency LightingSDR 070179Battery Pack · dischargedDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFNov 9, 2007 · N892GA · Doug MD83 · Emergency LightingSDR 070175Unknown · odorAFTER TAKEOFF HAD A BURNING OIL ODOR, THEN BOTH AFT LAVATORY SMOKE DETECTORS ALARMS WENT OFF. RETURNED TO LAS PER CONVERSATION WITH MAINTENANCE CONTROL PERSONNEL. LAS MAINTENANCE DEPARTMENT PERSONNEL PERFORMED HIGH POWER ENGINE GROUND RUNS, REFERENCE AMM 71-Nov 2, 2007 · N872GA · Doug MD83 · Air Distribution SystemSDR ANCF200700023Packing · brokenDURING APP AT BOG, R HYD QTY DROPPED TO 1 QT WITH THE SYSTEMS PRESSURIZED. THERE WAS NOT R HYD QTY ANNU ON THE EOAP. (THIS CAUSES EMERGENCY LANDING) SEVERE HYD LEAK FOUND AT FWD OUTLET LINE FITTING OF MOTOR OPERATED DUAL SHUTOFF VALVE. DURING INSPECTION FITTOct 16, 2007 · N632CT · Doug MD83 · Hydraulic System, MainSDR 070167Skin · puncturedON THE GROUND IN CHA, AIRCRAFT OUTER SKIN WAS PUNCTURED BY BELT LOADER. ACCOMPLISHED TEMPORARY REPAIR TO DAMAGED FUSELAGE BETWEEN STA 229 AND STA 275 IN ACCORDANCE WITH ERO 5330-002. AIRCRAFT FERRIED TO TUL FOR PERMENANT REPAIR. OPEN ITEMOct 14, 2007 · N892GA · Doug MD83 · Fuselage Main, Plate/SkinSDR 070170Battery Pack · inoperativeDURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE APPROPRIATE POWER SUPPLY BATTERY PACK. A SATISFOct 5, 2007 · N873GA · Doug MD83 · Emergency LightingSDR AALA20071838Circuit Breaker · trippedLGA FLIGHT T1060/02OCT - AUXILIARY POWER UNIT AND EXTERNAL POWER FAILED AFTER PARKING. PASSENGERS REPORTED EMERGENCY LIGHTS IN CABIN INOPERATIVE. FLIGHT ATTENDANTS REPORTED EXIT LIGHTS ON. RESET CIRCUIT BREAKER FOR EMERGENCY LIGHTS IN CABIN. SYSTEM GROUNDOct 2, 2007 · N9414W · Doug MD83 · Light System WiringSDR ANCF200700021Electrical Sys · multiple failDURING TAKEOFF ROLL, HAD AN ELECTRICAL FAILURE: TAKEOFF WAS ABBORTED AT 90 KNOTS. THE FLIGHT GUIDANCE STATUS AND MAINT PNL C/B G 25 WAS TRIPPED. THE AC BUSS PHASE B C/B WAS ALSO TRIPPED. ART WAS ACCURATED. IAW AMM 24-20-00/201 GCU`S WERE CHECKED AND RESET Sep 24, 2007 · N632CT · Doug MD83 · Electrical Power System
Back to Mcdonnell Douglas MD 83