Raytheon BAE 125-800A
Service difficulty reports · 282
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'BAE125800A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'BAE125800A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA110209024Wire · burnedDURING INSP, IN THE AFT EQUIPMENT BAY, THE ENTIRE LENGTH OF THE ABOVE MENTIONED WIRE WAS FOUND BADLY BURNED. 50 PERCENT OF THE WIRE INSULATION HAD BEEN MELTED OFF AND THE SURROUNDING WIRING HAD VISIBLE SCORCH MARKS THIS WIRE WAS USED AS THE GROUND FOR A NR OF SDR CA110209022Diaphragm · corrodedAFTER REMOVAL OF THE VENTRAL FUEL TANK FOR ROUTINE INSP, CORROSION WAS FOUND 1" BELOW FUEL FILLER AT 7 O`CLOCK POSITION. DURING CORROSION REMOVAL, IT WAS FOUND THAT IT HAD PROPAGATED ENTIRELY THROUGH THE AFFECTED AREA OF DIAPHRAGM 9.SDR CA110209021Outflow Valve · crackedDURING INSP OF THE REAR PRESSURE BULKHEAD, THE FLAPPER VALVES ON THE MAIN CABIN NON RETURN VALVE WERE FOUND TO BE STUCK IN THE OPEN POSITION. FURTHER INSP REVEALED THAT THE CTR SHAFT HAD TOOLING MARKS ON IT AND THE SHAFT WAS CRACKED. THE SPRINGS THAT FORCE THESDR CA110209019Pipe · crackedDURING REMOVAL OF THE ENGINE FOR INSP, IT WAS NOTED THAT THE PORTION OF PIPE EXTENDING PAST THE WELD LINE ON THE INNER SURFACE OF THE AFT COUPLING OF THIS TUBE HAD BEEN CRACKED AWAY. THERE WAS NO INDICATION OF CRACKING ON THE OUTER SURFACE OF THE PIPE, ONLY OSDR CA101116017Power Supply · overheated(CAN) STROBE POWER SUPPLY CAPACITOR OVERHEATED AND MELTED INSULATION RESIN CAUSING ODOR AND EYE IRRITATION TO PASSENGERS. OPEN CIRCUIT TO ONE OF THE THREE STROBE OUTPUT CIRCUITS CAUSED AFFECTED CAPACITOR TO OVERHEAT BECAUSE OF INABILITY TO DISCHARGE. THE CONSDR 2010F00225Annunciator · activatedCREW REPORTED THE "ENG 1 FUEL" ANNUNCIATOR ILLUMINATED DURNING FLIGHT.SDR 2010F00224Pump · failed(TM2R) CREW REPORTED THE "ENG NR1 FUEL" ANNUNCIATOR ILLUMINATED DURING FLIGHT.SDR CA100104004Terminal · burned(CAN) PILOTS REPORTED SMOKE IN THE COCKPIT. FIRST REPORTS THAT SMOKE CAME FROM THE INSTRUMENT PANEL. UPON INSP, FOUND LT WINDSHEILD C/B PN 6TC14-10. TERMNIAL A1 WAS BURNED AND DAMAGE TO THE WIRE.SDR CA090909002Seal · leakingNLG ACTUATOR SEAL FAILED OVER NIGHT WHILE ACFT WAS SITTING IN HANGAR. A LARGE AMOUNT OF HYD FLUID LEAKED, REQUIRING REPLACEMENT OF NOSE GEAR TIRES.SDR 2009FA0000202Modulator · failedRT MLG BRAKE MODULATOR FAILED CAUSING NR 4 BRAKE TO DRAG. THE ACFT PULLED TO THE RT DURING TAKEOFF ROLL. (K)SDR CA081104001Hose · leaking(CAN) PILOTS REPORTED LOSS OF HYD PRESSURE AFTER LANDING WHILE TAXING BACK TO AMO. ON INSP, FOUND IN THE RT GEAR WELL A FLEX HYD LINE INSTALLED WITH A SLIGHT TWIST ON IT. THE LOCKWIRE ON THE B-NUT WAS LOOSE, AND THE TWIST ON THE HYD LINE AIDED IN ALLOWING THESDR CA081021006Jackscrew · frozen(CAN) CREW REPORT THE ELEVATOR TRIM WAS DIFFICULT TO MOVE IN FLIGHT. UPON INSPECTION BY MX IT WAS FOUND THE ACTUATOR WAS CORRODED INTERNALLY AND THE GREASE WAS CONTAMINATED AND HARDENED. HAWKER BEECHCRAFT ALREADY HAS SB 27-3840 R1 TO CHECK FOR THIS SAME ISSUE SDR DGC2008F00002Line · crackedAT CRUISE FLIGHT, AFTER 1 HR 27 MIN INTO FLIGHT, THE LT OIL PRESSURE INDICATOR FLUCTUATED FROM APPROXIMATELY 42-45 PSI DOWN TO 30-35 PSI TWICE PER SECOND CONTINUOUSLY. OIL TEMP REMAINED NORMAL, ALL OTHER ENGINE INDICATIONS NORMAL, (N1, ITT, N2). APPROXIMATELY SDR 2008FA0000594Oxygen Mask · damagedTHREE OXYGEN MASKS WERE FOUND TO HAVE THE SAME FAULT. WHEN THE EMERGENCY/PRESS TO TEST CONTROL WAS TURNED TO EMERGENCY THERE WAS NOT A POSITIVE INCREASE IN PRESSURE. REF MFG MM 35-20-52, PAGE 502 TEST (13). PROBABLE CAUSE: UNKNOWN, RECOMMENDATION: INCREASE HOWSDR 2008FA0000593Oxygen Mask · failedTHREE OXYGEN MASKS WERE FOUND TO HAVE THE SAME FAULT. WHEN THE EMERGENCY/PRESS TO TEST CONTROL WAS TURNED TO EMERGENCY THERE WAS NOT A POSITIVE INCREASE IN PRESSURE. REF MFG MM 35-20-52, PAGE 502 TEST (13). PROBABLE CAUSE: UNKNOWN, RECOMMENDATION: INCREASE HOWSDR JLT2008F00000Pump · failedON THE EVENING OF FRIDAY, JULY 18TH, ON CLIMB, EN ROUTE, THE CREW OBSERVED THE LT ENGINE, SN 91535, FUEL LIGHT ILLUMINATED. THE CREW REDUCED POWER. ENGINE THEN EXPERIENCED AN UNCOMMANDED INFLIGHT SHUTDOWN. CREW SECURED THE ENGINE AND ATTEMPTED A RESTART. RESSDR A8O2008F00000Pump · failedEMERGENCY ACTION TAKEN DURING FLIGHT DUE TO A COMPONENT OR SYSTEM MALFUNCTION. AFTER DUAL ENGINE REPLACEMENT DUE TO MPI, ON TEST FLIGHT, CREW DISCOVERED DUAL FUEL OVERTEMP ANNUNCIATOR LIGHTS CAME ON. CREW DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE WHERE SDR 2008FA0000382Regulator · damagedRECEIVED O/H OIL TEMP REGULATOR FROM MFG UNDER THEIR WO 815978-001, DATED 04/22/2008. WHILE PERFORMING INCOMING PARTS INSPECTION ON 04/24/2008, FOUND FUEL INLET PORT SMASHED. THERE WAS NO DAMAGE TO THE SHIPPING CONTAINER. PROBABLE CAUSE OF DAMAGE WAS MOST LSDR DELA200700009Fuel Filter · unknownENG 2 FUEL LIGHT. ABORTED TAKEOFF DUE TO ENGINE 2 FUEL LIGHT ON. REPLACED FILTER WITH NEW, PERFORMED GROUND ENGINE RUN, NO LEAKS NOTED, (ENG 2 FUEL) ENUNCIATOR DID NOT ILLUMINATE.SDR CA071126007Computer · inoperative(CAN) ENGINES FRESH, NEW INSTALLATION OF DEECS ON AC. DEEC PROBLEMS OCCURRED. THE PROBLEM ENCOUNTERED WITH DIGITAL ENGINE COMPUTERS (DEEC). (TC NR 20071126007)SDR CA071016021Float Valve · stuck(CAN) DURING REFUELLING USING SINGLE-POINT SYS & FILLING BOTH MAIN (WINGS) & VENTRAL TANK. AS VENTRAL TANK REACHED 1.5 TO 3 QUARTERS CAPACITY FUEL WOULD FLOW THROUGH VENT SYS INTO LT SURGE TANK & SHUTDOWN BY CLOSING MAIN VALVE. COMPLETION OF REFUELLING COULD OSDR IJO2007F00000Warning Light · false indicationAFTER TAKEOFF, LANDING GEAR SELECTED UP. AT ABOUT 1,000 FT AGL, NOSE & RT MLG RED TRANSITION LIGHTS WERE STILL ILLUMINATED. SELECTED LANDING GEAR DOWN, AT WHICH TIME ALL 3 GREEN SAFE LIGHTS ILLUMINATED, ALONG WITH AN INCREASED WIND NOISE LEVEL FROM THE EXTENSDR 2007FA0000885Vane · corrodedLT IB FLAP VANE, UPPER SKIN CORRODED BEYOND LIMITS. POSSIBLE CAUSE: DISSIMILAR METAL CORROSION AS TRAILING EDGE IS MAGNESIUM AND SKIN IS ALUMINUM OR ENVIRONMENT IN WHICH THE VANE OPERATES. IT IS LOCATED BEHIND THE MLG. ASSURE THE SKIN IS PROPERLY TREATED IAWSDR 2007FA0000801Support · corrodedLT MLG DOOR IB AFT SUPPORT REMOVED FOR OTHER MAINTENANCE AND SEVERE INTERGRANULAR CORRODION DISCOVERED FROM LAVATORY LEAKAGE AS INDICATED BY STAINING ON PART LOCATION WHERE BONDING STRAP ATTACHES. CORROSION SEVERE AND IS ENOUGH TO CAUSE PART TO FAIL. (K)SDR 2007FA0000800Actuator · unserviceableRT MLG ACTUATOR CRACKED ATTACH HOUSING DISCOVERED DURING WHEEL WELL INSPECTION, PART WAS NOT LEAKING BUT COULD SEPARATE AT ANY MOMENT AND CAUSE SEVERE DAMAGE TO AIRCRAFT DATE OF ASSY OF ACTUATOR 1/92. (K)SDR CA070827003Seal · deteriorated(CAN) UPON CLIMB OUT WITH CABIN DIFFERENTIAL PRESSURE APPROACHING APPROXIMATELY 6 PSI, A DISTINCT AUDIABLE DISCERNING NOISE WAS HEARD FROM THE CENTER AREA OF THE CABIN. DURING DESCENT WHERE CABIN DIFFERENTIAL PRESSURIZATION FELL BELOW 6 PSI, NOISE WOULD SUBSIDSDR IJ02007F00000Strut · collapsed(REF CNTRL NR: 1-15-07) DURING THE TAKEOFF ROLL (APPROXIMATELY 100 KTS), THE CREW EXPERIENCED BOUNCING OF THE AIRCRAFT NOSE WITH INCREASING SEVERITY. THE CREW CONTINUED THE TAKE-OFF SEQUENCE, AND NOTED A RED NOSE GEAR (UNSAFE) INDICATION LIGHT AFTER THE LANDISDR 2007FA0000072Bearing · failedFORWARD BEARING FAILED.SDR 2007FA0000054Bearing · failedFORWARD BEARING FAILEDSDR AMCR200600003Tire · leakingAFTER MOUNTING A NEW GOODYEAR TIRE ON AN AHA1814 WHEEL, THE TIRE FAILED THE 24 HOUR LEAK CHECK. EXCESSIVE VENTING WAS SEEN FROM MANY VENT HOLES IN THE BEAD AREA. TWO ADDITIONAL 24 HOUR CHECKS WERE PERFORMED AND LEAK RATE WAS ABOUT 19 PERCENT LOSS. AGAIN, EXCESSDR CA061104001Plate · corroded(CAN) UPON VISUAL INSPECTION AND CLEANING OF ATTACHMENT LUG AREA OF VERTICAL FIN TO HORIZONTAL STABILIZER, MECHANIC NOTICED MATERIAL FLAKING OFF OF ONE BOLT HOLE. FURTHER INSPECTION REVEALED EXFOLIATION CORROSION. SINCE THIS TYPE OF CORROSION IS DIFFICULT TO DSDR AOQ2006F00003Switch · intermittent(REF NR: ON 800FH101706JC) AFTER TAKEOFF, COULD NOT RAISE LANDING GEAR. INSPECTED LANDING GEAR. FOUND LEFT WEIGHT ON WHEELS SWITCH TO BE INTERMITTENT. REPLACED LEFT MAIN GEAR WEIGHT ON WHEEL MICROSWITCH. ACCOMPLISHED SEVERAL GEAR SWINGS WITH SATISFACTORY SDR DJFA2006330Skin · crackedA CRACK WAS DISCOVERED IN THE RIGHT SIDE INBOARD AIRBRAKE ON THE UPPER SKIN 3/4 OF AN INCH FROM THE TRAILING EDGE AND APPROXIMATELY 10 TO 12 INCHES IN LENGTH. THE UPPER AIRBRAKE ASSEMBLY WAS REPLACED IN ACCORDANCE WITH THE HAWKER 800 MAINTENANCE MANUAL AND THSDR COZ2006F00000Display · unreliableAT FLIGHT LEVEL 34 K, FLIGHT CREW ENCOUNTERED STATIC BUILD UP IN THE COMM SYSTEM. IT WENT AWAY SHORTLY FOLLOWED BY AUTOPILOT DISCONNECTING AND PRIMARY DISPLAYS BECAME UNRELIABLE. THE AIRCRAFT LANDED SAFELY. ON THE GROUND, FLIGHT CREW POWERED DOWN THE AIRCRSDR DJFA2006304Seat Track · crackedDURING A SCHEDULED MAINTENANCE VISIT THE CO-PILOTS SEAT RAIL WAS FOUND CRACKED. THE BASE AND LIFT MECHANISM ON THE SIDE PLATE OF THE CO-PILOTS SEAT ASSEMBLY WAS REPLACED IAW THE IPECO COMPONENT MM. NO FURTHER DEFECTS WERE NOTED.SDR DJFA2006301Seat Track · crackedDURING A SCHEDULED MAINTENANCE VISIT A CRACKED WAS DISCOVERED IN THE CO-PILOTS RIGHT COCKPIT SEAT RAIL WEB BETWEEN FRAMES 5 AND 7.SDR DJFA2006308Seat Track · crackedDURING A SCHEDULED MAINTENANCE VISIT A CRACK WAS DISCOVERED IN THE CO-PILOTS RIGHT COCKPIT SEAT RAIL WEB BETWEEN FRAMES 5 AND 7. THE CRACK WAS REPAIRED IN ACCORDANCE WITH RAYTHEON AIRCRAFT FIELD REPAIR DRAWING SR-HK-02034 REVISION 1 BY INSTALLATION OF A REPAISDR YNTA200690401Pump · malfunctionedFUEL FILTER BYPASS ANNUNCIATION DUE TO INTERNAL FUEL PUMP ANTI ICE VALVE FAILURE DIVERTING FUEL PREMATURELY TO THE FUEL HEATER. (THE ANNUNCIATOR PICKS UP FUEL OVERHEAT CONDITION AS WELL AS DIFFERENTIAL PRESSURE RANGES INDICATING CLOGGED FILTER ELEMENTS.)SDR 2006FA0000474Wheel Half · crackedDURING ROUTINE TIRE CHANGE AND EDDY CURRENT INSPECTION OF DUNLOP MAIN WHEEL HALF AND FLANGE. EDDY CURRENT INSPECTION REVEALED TWO CRACKS WHICH RADIATED OUT FROM WHEEL TIE BOLT HOLE. BOTH CRACKS WERE APPROMIXATELY .050 INCHES IN LENGTH. PART WAS REJECTED AND RESDR DJFA2006221Valve · failedCLIMBING FROM FL 230 TO FL 270 FLT DECK HEAT VALVE OPENED, THEN AN UNSUCCESSFUL ATTEMPT WAS MADE TO CLOSE VALVE. HEAT EMANATING FROM DUCTS BECAME UNBEARABLE & APPROX 5 MINS LATER SMOKE BEGAN TO EMANATE FROM HEATING DUCTS. CREW DONNED THEIR OXYGEN MASKS AND DSDR DJFA2006216Exhaust Duct · leakingDURING A SCHEDULED MAINTENANCE VISIT WHILE PERFORMING APU METER READINGS, THE APU EXHAUST WAS FOUND TO HAVE AN EXTENSIVE LEAK WHERE THE EXHAUST FLANGE MOUNTS TO THE AIRFRAME. THE EXHAUST GASKETS WERE REPLACED. OPERATIONAL CHECKS WERE GOOD, AND THE AIRCRAFT WSDR RU32006F00002Landing Gear · malfunctionedGEAR HANDLE WOULD NOT MOVE TO UP POSITION. AC LANDED WITH GEAR LEFT IN DOWN POSITION. OVERWEIGHT LANDING INSPECTION REQUIRED. VISIBLE PRECIP. ICING PREVAILED ON GROUND AT T/O AND AT LEVEL OFF ALT OF 5000MSL. CLEANED SELECTOR LEVER AND MICROSWITCH IN NOSE SDR SQJ2006F00000Wire · chafedEVERY TIME THE NAV LIGHTS WERE SELECTED THE NAV LIGHT CIRCUIT BRAKER WOULD OPEN. LT AND TAIL NAVE LIGHTS WOULD MOMENTARILY ILLUMINATE THEN EXTINGUISH, RT WOULD NEVER ILLUMINATE. TROUBLESHOT PROBLEM TO A CHAFED WIRE IN A CONDUIT BEHIND THE RT WING LEADING EDGSDR DJFA2006187Floor Skin · leakingUNSCHEDULED MX VISIT DISCREPANCY - LEAK AROUND THE LAVATORY AREA, CORROSION ON ACFT SKIN BELOW FLOOR PANEL F-84 BETWEEN FR 17 & 18. TWO CRACKS ON STR 16 UNDER LAVATORY ON LT OF FUSELAGE BETWEEN FR 16 & 19. NUMEROUS CORRODED WIRE SPLICES & CONNECTORS REPLACEDSDR SQJ2006F00001Tube · brokenBLEED AIR TUBE (PN C46P181211) WAS REMOVED TO GAIN ACCESS TO PYLON. WHEN TUBE WAS REMOVED 2 PIECES OF CURLED METAL FOUND LODGED IN NACELLE ANTI-ICE SHUTOFF VALVE (PN 27441482). PIECES OF METAL WERE REMOVED W/O EFFORT. INSP WAS PERFORMED ON TUBE, FOUND WHENSDR CA051130010Bracket · unserviceableON APPROACH WITH FLAPS SELECTED TO 15 DEG STALL IDENT LIGHT CAME ON THE ANNUNCIATOR PANEL. ON INVESTIGATION FOUND FLAP OUTBD MICROSWITCH OFF THE CAM FROM SWITCH ASSY. FURTHER INVESTIGATION WAS CARRIED OUT AND FOUND THE OUTBD BRACKET BROKEN FOR SWT SUPPORT. SDR CA051130009Wire Harness · failedON APPROACH WHEN GEAR SELECTED DOWN, GEAR UNSAFE LIGHT CAME ON, GEAR IN TRANSIT. GOT ALL (3) GREENS LEFT, RIGHT AND NOSE, BUT NOSE UNSAFE LIGHT REMAINED ON. DID FLY BY, TOWER REPORTED NOSE GEAR APPEARS TO BE DOWN. PILOTS CONFIRMED (3) GREENS FOR GEAR, IT WASDR DJFA2005155Autopilot Sys · malfunctionedWHEN CREW SELECTED VERTICAL SPEED ON MODE CONTROL PANEL TO BEGIN DESCENT, AC BEGAN STEEP CLIMB, AIRSPEED INDICATOR WAS NEAR BARBER POLE. CONTROL COLUMN YOKE WAS PUSHED FWD TO REDUCE CLIMB. AC FOUGHT CREW BY TRIMMING AC FURTHER NOSE UP. CLIMB WAS REPORTED TSDR 2005FA0001474Bulb · improper partA SELA FLORESCENT BULB WAS FOUND IN THE CABIN LIGHTING SYSTEM. THIS SYSTEM IS AN ALC SYSTEM. THE SELA BULB HAD IMPROPER CONNECTORS ON IT AS WELL. WE CHANGED OUT THE SELA BULB WITH AN ALC BULB AND USED THE PROPER CONNECTORS WHEN INSTALLING IAW AD 95-22-01 ANSDR 2005FA0001334Brake Assy · overheatedPILOT NOTICED LT OB TIRE WAS FLAT. MAINT FLEW TO AIRPORT AND CHANGED BOTH LT MAIN GEAR WHEEL AND TIRE ASSYS. AC WAS THEN FLOWN BACK. UPON INSPECTION OF FLAT TIRE IT WAS FOUND THAT ALL 3 FUSIBLE PLUGS HAD MELTED. INSPECTED THE LT OB BRAKE AND FOUND IT HAD OVE
Back to Raytheon BAE 125-800A