Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '340B' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '340B' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MALA050207Duct · burnedLEFT INTAKE CAUTION LIGHT ON AND CYCLED OFF. ODOR NOTED ABOUT 5 MN LATER IN FLT DECK. ON POST FLT NOTED DAMAGE TO LEFT INTAKE. REMOVED AND REPLACED BURNED LEFT LOWER INTAKE DUCT, SN OFF L169235 SN ON L198068. ALL CHECKS GOOD.SDR MALA050148Airstair Track · corrodedDURING 4K CHECK FOUND RAIL ASSEMBLY, P/N 7253710-871 BETWEEN FS 258 AND 288 IS CORRODED AND WILL BE REPLACED IAW SRM 51-40-21.SDR MALA050226Brake · overheatedON LANDING ROLL A/C PULLED TO THE RIGHT. POST FLIGHT NOTED LT O/B BRAKE SMOKING. REMOVED LT O/B WHEEL ASSY. INSPECTED WHEEL BEARING AXLE. CONFIRMED BRAKE ASSY ACTUATES. NO OBVIOUS DISCREPANCY NOTED. REINSTALLED WHEEL ASSY IAW JOB CARD 3240-301&302. OBSESDR MALA050173Seat Track · corrodedDURING 4K CHECK IN BNA FOUND SEAT TRACK AT LBL 18.3 IS CORRODED OUT OF LIMITS FROM FS 298 TO FS 345 AND WILL BE REPLACED IAW MESABA EOS53060.SDR PNSA050203Brake Assy · malfunctionedDURING TAXI INTO PARKING AREA AT LIMA GATES IN ANC THE CAPTAIN STATED THERE WAS A BRAKE PROBLEM. COPILOT CHECKED BRAKES AND FOUND FULL TRAVEL OF PEDALS AND NO PRESSURE. AIRCRAFT WAS TURNED AWAY FROM GATE AND CAME TO A SLOW STOP. MAINTENANCE TOWED AIRCRAFT TSDR MALA050206Floor Support · corrodedDURING 4Y/2Y CHECK IN BNA, FOUND FLOOR SUPPORT FLANGE AT PAX DOOR THRESHOLD IS CORRODED OUT OF LIMITS. DAMAGE IS ACCEPTABLE PER EMAIL FROM MESABA ENGINEER, KEN SEVERSON, DATED 2/1/05. REF EAMS WORKORDER 211546 TASK 1517.SDR MALA050185Power Supply · inoperativeEMERGENCY POWER SUPPLY P/N 501-1712-02, S/N 1466 FAILED SCHEDULED CAPACITY CHECK. REPLACED 2 EACH CELL PACKS 549-1324-06. UNIT PASSES CMM CHECKS, RTS 2/4/05.SDR MALA050205Structure · corrodedDURING 4Y/2Y CHECK IN BNA, FOUND LT WRAP AROUND PN 7253711-245 IS CORRODED OUT OF LIMITS AND HAS BEEN REPLACED WITH A NEW PART IAW SRM 51-40-21. REF EAMS WORK ORDER 211546 TASK 1516.SDR MALA050204Seat Track · corrodedDURING 4Y/2Y CHECK IN BNA, FOUND SEAT TRACK AT LBL 18.3 IS CORRODED FROM FS 294 TO FS 319. DAMAGED AREAS HAVE BEEN REPAIRED IAW SRM 53-70-60 REF. EAMS WORK ORDER 211546 TASK 1516.SDR MALA050203Seat Track · corrodedDURING 4Y/2Y CHECK IN BNA, FOUND SEAT TRACK AT BLO IS CORRODED OUT OF LIMITS FROM FS 294 TO FS 319 AND HAS BEEN REPAIRED IAW SRM 53-70-60. REF EAMS WORK ORDER 211546 TASK 1515.SDR MALA050200Seat Track · corrodedGALLEY SEAT TRACK AND PROFILE PN 7253721-459 AND 7253721-495 ARE CORRODED OUT OF LIMITS AND HAVE BEEN REPLACED WITH NEW PARTS IAW SRM 51-40-21 AND SRM 51-40-27. REF EAMS WORK ORDER 211546 TASK 1507, FOUND DURING 4Y/2Y CHECK IN BNA.SDR MALA050202Web · corrodedREINFORCEMENT WEB, PN 7253721-439 IS CORRODED OUT OF LIMITS AND HAS BEEN REPLACED IAW SRM 51-40-21. REF EAMS WORKORDER 211546 TASK 1514, FOUND DURING 4Y/2Y CHECK IN BNA.SDR MALA505201Seat Track · corrodedSEAT TRACK AT BLO IS CORRODED FROM FS 630 TO FS 686. DAMAGE HAS BEEN REPAIRED IAW MESABA EO NR S53076. REF EAMS WORK ORDER 211546 TASK 1505, FOUND DURING 4Y/2Y CHECK.SDR MALA050196Warning Light · illuminatedLT "ALPHA" LIGHT AFTER T/O. AIR RETURN TO MEMPHIS DUE TO ICE RESTRICTION.SDR MALA050199Power Supply · failedEMERGENCY POWER SUPPLY 20LN FAILED CAPACITY CHECK IAW JOB CARD 335003.SDR MALA050176Power Supply · failedEMERGENCY POWER SUPPLY P/N 501-1712-02, S/N 2089 FAILED SCHEDULED CAPACITY CHECK. REPLACED 2 EA CELL PACKS P/N 549-1329-06. UNIT PASSES CMM CHECKS, UNIT RTS 1/31/05.SDR 01262005Warning Light · illuminatedAVIONICS SMOKE LIGHT ILLUMINATED ON THE GROUND.SDR MALA050208Monitor · malfunctionedLEFT PITOT LIGHT ILLUMINATED IN FLIGHT. QRH COMPLETED. RETURNED TO DTW. REMOVED AND REPLACED 5HG CURRENT MONITOR, PN ON/OFF 006WS00 SN 1581, SN OFF 1627. LEFT PITOT TUBE PN ON/OFF 856ML3, SN ON 214837, SN OFF 215686. ALL CHECKS GOOD IAW SF 340 M/M CH 31 ANSDR MALA050198Smoke Detector · malfunctionedAFTER STARTING NR 2 ENGINE CREW NOTED CARGO SMOKE LIGHT WAS ILLUMINATED. FA INVESTIGATED. NO SMOKE FOUND. CREW HAD RAMP AGENTS CHECK CARGO BAY AND NO SMOKE WAS FOUND IN CARGO BAY. LIGHT STAYED ON WITH NO SMOKE IN CARGO BAY. REPLACED NR 2 CARGO BIN SMOKE DSDR MALA050210Sensor · malfunctionedIN FLIGHT RT BLEED FAULT ILLUMINATED WITH RT DUCT OVERTEMP. RAN QRH AND THEY CAME BACK ON. RETURNED TO MEM. REMOVED AND REPLACED RT DUCT TEMP SENSOR PN 754691-1 AND TEMP SWITCH PN M2035-501 IAW AMM CH 21. OPS CHECK GOOD.SDR MALA050140Inlet · chafedDURING 6Y/4Y INSPECTION IN YYC, LT NACELLE, INLET PROTECTION DEVICE P/N NF24668-057 IS CHAFED COMPLETELY THROUGH AND IS BEING REPLACED. AIRCRAFT RETURNED TO SERVICE 01/18/2005.SDR MALA050139Seat Track · corrodedDURING 6Y/4Y INSPECTION IN YYC, GALLEY SEAT TRACK P/N 7253721-459 IS CORRODED OUT OF LIMITS AND WILL BE REPLACED IAW SRM 51-40-27. AIRCRAFT RETURNED TO SERVICE 01/18/2005.SDR MALA050137Engine · malfunctionedRIGHT GEN FAIL LIGHT ILLUMINATED RIGHT ENGINE OIL PRESSURE WARNING LIGHT ILLUMINATED. OIL PRESSURE DROPPED TO ZERO ENGINE SHUT DOWN IN COMPLIANCE WITH QRH. DIVERTED A/C TO RST. MAINTENANCE REPLACED RIGHT ENGINE PER TASK CARD 7100-301, P/N ON CT7-9B, S/N ON SDR MALA050115Seat Track · corrodedDURING 6Y/4Y INSPECTION IN YYC, SEAT TRACK AT LBL 18.3 CORRODED OUT OF LIMITS FROM FS 520 TO FS 686.888. DAMAGE WILL BE REPAIRED IAW MESABA EO S53060. AIRCRAFT RETURNED TO SERVICE 1/18/05.SDR SIMA200501903Light · inoperativeCREW REPORTED FLOOR PROXIMITY EMERGENCY LIGHT STRIP AT ROW 9/10 TO BE INOPERATIVE. LIGHT WAS PUT ON MEL AT THIS TIME. MAINTENANCE REMOVED AND REPLACED THE LIGHT STRIP IAW MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (SW21200502551) (SDR CX7A194J0508Fire Loop · chafedNR 2 ENGINE SPORADIC SHORT FIRE WARNINGS AT LOW POWER SETTINGS, FIRE DETECT FAIL CAME ON, ON THE GROUND AND WENT OUT.SDR 01142005Fire Warning · illuminatedLT TAIL PIPE HOT LIGHT ILLUMINATED AFTER TAKE OFF.SDR 019105Warning Light · illuminatedLEFT TAIL PIPE HOT LIGHT ILLUMINATED AFTER TAKEOFF.SDR CX7A194J0507Smoke Detector · defectiveDURING CLIMB SHORTLY AFTER TAKEOFF, CARGO SMOKE WARNING ILLUMINATED, RAN CHECKLIST AND DISCHARGED FIRE BOTTLE. RETURNED TO AIRPORT. AFT CARGO SMOKE DETECTOR FOUND DEFECTIVE.SDR MALA050134Duct · damagedRIGHT INTAKE HEAT INOP. AIR RETURN TO MEM. MAINTENANCE REPLACED RIGHT LOWER INLET DUCT REFER AMM CHAP 30 P/N ON/OFF NH24668, S/N OFF L211774, S/N ON L197704. TEST IS GOOD.SDR MALA050132Starter Gen · failedDURING BATTERY START ON NR 2 ENGINE MOTORED TO 22 PERCENT, INTRODUCED FUEL GOT LIGHT OFF, FOLLOWED BY A DECREASE IN ROTATION AND A FIRE SIGNAL FROM THE RAMP AGENT. RIGHT HANDLE PULLED AND FIRE BOTTLE FIRED. RAN, NO FIRE. MAINTENANCE REMOVED AND REPLACED RIGSDR MALA050128Power Supply · inoperativeEMERGENCY LIGHTS AT 7LN, 9LN, 10LN, 42LN, 43LN & 44LN INOP. MAINTENANCE REPLACED EMERGENCY POWER SUPPLY AT 20LN. P/N 3301-51.SDR MALA050195Arm · crackedBRACKET FOR HOLD OPEN ARM ON SPR DOOR IS CRACKED AND WILL BE REPLACED IAW SRM 51-40-21. REF EAMS WORK ORDER 211360 TASK 6501.SDR CA050113005Landing Gear · failed(CAN) AFTER A NORMAL LANDING, THE AIRCRAFT TAXIED OFF THE RUNWAY AND STOPPED IN FRONT OF THE AIRPORT TERMINAL. THE ENGINES WERE SHUT DOWN AND THE CREW COMPLETED THEIR COCKPIT CHECKS. WHEN THE ELECTRICAL MASTER SWITCH WAS TURNED TO OFF THE NOSE UNDERCARRIAGE RSDR MALA050127Stiffener · corrodedDURING 4Y/2Y INSPECTION IN BNA, WEB REINFORCEMENT PN 7253721-439 IS CORRODED OUT OF LIMITS. THE DAMAGED AREAS HAVE BEEN REPAIRED IAW SRM REFER EAMS WO NR 211360, TASK 2503 FOR ADDITIONAL INFORMATION. AIRCRAFT RETURNED TO SERVICE 1/15/05.SDR MALA050126Bracket · crackedDURING 4Y/2Y INSPECTION IN BNA, BRACKET PN 7252456-003 FOR HOLD OPEN ARM ON SPR DOOR IS CRACKED AND WILL BE REPLACED IAW SRM 51-40-21. REFER EAMS WO NR 211360, TASK 6501 FOR ADDITIONAL INFORMATION. AIRCRAFT RETURNED TO SERVICE 1/15/05.SDR MALA050130Connector · looseLEFT PROP NP INDICATION WENT TO ZERO WHEN PROPS WENT TO MAX ON FINAL. AFTER LANDING IT WENT BACK TO NORMAL. MAINTENANCE COULD NOT DUPLICATE PROBLEM. UPON INSPECTION OFF LEFT ENGINE YELLOW HARNESS FOUND CONNECTOR TO DECU EXTREMELY LOOSE AND CONNECTOR TO NP SSDR MALA050114Lead · damagedWITH PROP DEICE SELECTED NORM, THE LEFT PROP CAUTION LIGHT ILLUMINATED AND THE LEFT PROP DEICE LIGHT WENT OUT. AIR RETURN TO MSP. MAINTENANCE FOUND BAD PROP LEAD, REPLACED NR 3 PROP BLADE LEAD PN 666000219, OPS CHECK GOOD PER DOWTY PROP CMM 61-10-39.SDR MALA050113Pad · obstructedGEAR INTRANSIT LIGHT STAYS ILLUMINATED IN THE RETRACTED POSITION. AIR RETURN TO MSP. MAINTENANCE JACKED A/C PER AMM 07-10-00, SWUNG GEAR VERIFIED INTRANSIT LIGHT STAYED ON REMOVED ICE BUILD UP ON GEAR STOP PADS, SWUNG GEAR SEVERAL TIMES NO INTRANSIT LIGHT NOSDR MALA050112Duct · burnedLEFT INTAKE LIGHT ILLUMINATED INTERMITTENTLY ABOUT EVERY 20 SECONDS IN FLIGHT. NO OTHER ABNORMAL INDICATIONS. AIR RETURN TO DTW. MAINTENANCE FOUND LOWER DUCT BURNED. REMOVED AND REPLACED LOWER DUCT LT SIDE, OPS CHECK GOOD IAW SAAB MM 30 SN/OFFL180888, SN/OSDR MALA050209Smoke Detector · malfunctionedLAV SMOKE DETECTOR LIGHT ILLUMINATED ON TAKEOFF ROLL. RETURNED TO GATE. REPLACED DETECTORSDR MALA050125Post · corrodedDURING C-CHECK IN YYC, COCKPIT DOOR RT VERTICAL POST AT RBL 10.5 IS CORRODED AT FLOOR LEVEL AND WILL BE REPAIRED IAW MESABA EO. REFER EAMS WORK ORDER 211363, TASK 1509 FOR ADDITIONAL INFORMATION A/C RETURNED TO SERVICE 1/12/2005.SDR MALA050120Seat Track · corrodedDURING 4Y/2Y CHECK IN BNA, SEAT TRACK AT LBL 18.3 BETWEEN FS 294-319 IS CORRODED OUT OF LIMITS AND HAS BEEN REPAIRED IAW MESABA EO NR S53079. REFER EAMS WO NR 211363, TASK 1511 FOR ADDITIONAL INFORMATION. AIRCRAFT WAS RELEASED 1/11/05.SDR MALA050119Seat Track · corrodedDURING 4Y/2Y CHECK IN BNA, SEAT TRACK AT BL0 BETWEEN FS 294 AND FS 319 IS CORRODED OUT OF LIMITS AND HAS BEEN REPAIRED IAW MESABA EO NR 53079. REFER EAMS WO NR 211363, TASK 1512 FOR ADDITIONAL INFORMATION. AIRCRAFT WAS RELEASED 1/11/05.SDR MALA050118Structure · corrodedDURING 4Y/2Y CHECK IN BNA, LT WRAP AROUND PN 7253710-243 IS CORRODED OUT OF LIMITS AND HAS BEEN REPLACED IAW SRM 51-40-21 REFER EAMS WO NR 211363, TASK 1534 FOR ADDITIONAL INFORMATION. AIRCRAFT WAS RELEASED 1/11/05.SDR MALA050110Strut · underservicedLANDING GEAR INTRANSIT LIGHT REMAINED ON WELL AFTER GEAR HANDLE WAS SELECTED UP. PERFORMED QRH. CONDITION REMAINED. AIR RETURN TO CID. MAINTENANCE SUSPECT NLG NEVER EXTENDED FULLY TO ENGAGE CENTERING CAM. AFTER PROPER SERVICING STRUT RAN GEAR EXTENSION/RESDR MALA050122Seat Track · corrodedDURING 4Y/2Y CHECK IN BNA, GALLEY SEAT TRACK PROFILE PN 7253721-495 IS CORRODED OUT OF LIMITS AT FS 272. DAMAGED PART WILL BE REMOVED AND REPLACED IAW SRM NR 514021. REFER EAMS WO NR 211363, TASK 1514 FOR ADDITIONAL INFORMATION. AIRCRAFT WAS RELEASED 1/11/0SDR MALA050123Seat Track · corrodedDURING 4Y/2Y CHECK IN BNA, SEAT TRACK AT LBL 18.3 BETWEEN FS 294-319 IS CORRODED OUT OF LIMITS AND HAS BEEN REMOVED AND REPLACED AS NEEDED IAW MESABA EO NR S53060. REFER EAMS WO NR 211363, TASK 1511 FOR ADDITIONAL INFORMATION. AIRCRAFT WAS RELEASED 1/11/05.SDR MALA050121Seat Track · corrodedDURING 4Y/2Y CHECK IN BNA, GALLEY SEAT TRACK IS CORRODED OUT OF LIMITS AND HAS BEEN REPLACED PN 7253721-459 IAW SRM 51-40-27. REFER EAMS WO NR 211363, TASK 1503 FOR ADDITIONAL INFORMATION. AIRCRAFT WAS RELEASED 1/11/05.SDR MALA050117Structure · corrodedDURING 4Y/2Y CHECK IN BNA, RT WRAPAROUND PN 7253710-243 IS CORRODED OUT OF LIMITS AND HAS BEEN REPLACED IAW SRM 51-40-21 REFER EAMS WO NR 211363, TASK 1535 FOR ADDITIONAL INFORMATION. AIRCRAFT WAS RELEASED 1/11/05.
Back to Saab 340B