As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON DEPARTURE FROM SBA, "KRUEGER FAIL" EICAS MESSAGE CAME ON & KRUEGER & SLATS WOULD NOT RETRACT. ON THE GROUND FLAPS & SLATS OPS NORMAL. PER CUSTOMER REQUEST PERFORMED CMP 275101 FLAP/SLAT CONTROL AND DRIVE SYSTEM- FUNCTIONAL TEST. NO DEFECTS NOTED. PERFORMED ENGINE RUNS TO CHECK OUTPUT OF ENGINE DRIVEN HYD PUMP DURING KRUGER OPERATION WITH NO DEFECTS NOTED.