What was found
RIGHT ENG FIRE DETECTION LIGHT ILLUMINATED ON CLIMB OUT APPROX 4000-5000 FT FOR ONE SECOND. RECEIVED 1 AURAL RT ENG FIRE CALL & RED CAS MSG FOR LESS THAN 1 SECOND. IMMEDIATELY CHECKED ENG PARAMETERS. ALL INDS NORMAL, NO SECONDARY INDS OF A FIRE. ALL INDS NORMAL REMAINDER OF FLT. PERFORMED ARES DOWNLOAD & SENT TO MANUF.FOR REVIEW. REMOVED PCB & FOUND A CLEAR THICK SUBSTANCE ON CONNECTOR FACES. CLEANED CONNECTIONS IAW SPM 20·30-05. PERFORMED SATIS WIRING CHECKS FROM PCB TO RT ENG FIRE DETECTOR ASSY. NSTALLED PCB & CONNECTOR IAW MM 24-60-35. OPS CHKED GOOD. PERFORMED A SATIS ENG FIRE SENSOR VISUAL CHK OF RT ENG LOOP IAW HM 26-10-00.