What was found
WHEN FLAPS 25 SELECTED GOT A LE SLAT DISAGREE EICAS. DECLARED AN EMERGENCY RAN QRH CHECKLIST AND UNEVENTFUL LANDING WMKP 04, WE DID EXECUTE A MISSED APPROACH FSEU BITE CHK FOUND FAULT CODE 27-81045 LEG 0. NO EXISTING FAULT. CYCLED FLAP 3 TIMES, PERFORMED TEST OF THE LEADING EDGE SLAT SYSTEM, FOUND SATISFACTORY. PERFORMED PSEU BITE TEST , SATIS . WORK CARRIED OUT IAW AMM 27-51-00-5, 27-81-00-5 , FIM 27-51-00-1 AND FIM 32-09. ALL TEST FOUND SATIS. A/C OK FOR SERVICE.