Service difficulty reports
1,773,593 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IXXA202504150402Floor Support · corrodedBULK CARGO CENTER FLOOR SUPPORT STA 1439 CORRODED AROUND NUTPLATESDR IXXA202504150001Skin · crackedP-31 PNL BONDING STRAP ATTACHMENT STUD SKIN IS CRACKEDSDR WRXR20250415001Hinge Fitting · gougedON RIGHT OUTBOARD FLAP, MIDDLE HINGE LUG LOWER FITTING, SMALL DENT WAS DISCOVERED. DEPTH OF GOUGE READS AT .0085". BLENDED DAMAGE IAW CRJ 900 SRM 51-71-00-001-001-A01. ROTO-PEENED REWORKED AREA IAW CRJ 900 SRM TASK 51-24-11-001-001-A01 AND REO 690-57-53-165.SDR 9WGA2025042854601Ring · corrodedNR# 286 - DURING HEAVY MAINTNENANCE #2 ENGINE L/E OF CONTAINMENT RING HAS CORROSION AROUND BOTTOM HALF. ACCOMPLISHED WITH ENGINE REMOVED AND REPLACEMENT IAW MD-11 T/C: MS-71-00-03-00-00-01-WG, SEQ, W/O#15700 AND AMM 71-00-03-000-801. THE AIRCRAFT WAS APPROVSDR 9WGA2025041445614Bracket · corrodedDURING HEAVY MAINTENANCE CHECK HYDRAULIC DRAIN LINE BRACKET ON FWD WALL, BOTTOM, CENTER INSIDE PNL 316AB CORRODED. REMOVED AND REPLACED BRACKET ON HYDRAULIC DRAINN LINE ON FWD WALL BOTTOM CENTER INSIDE PNL 316AB IAW MD-11 SRM 51-31-01. THE AIRCRAFT WAS APPROSDR 9WGA2025041454609Shroud · crackedDURING HEAVY MAINTENANCE PILOTS SLIDING WINDOW FWD SHROUD COVER HAS A CRACK. REPAIRED AND RE-INSTALLED PILOT SLIDING WINDOW FWD SHROUD COVERS IAW MD-11, AMM 20-20-00 AND 20-20-09. (FWD SHROUD COVER REPAIRED). THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR 9WGA2025041454604Skin · puncturedDURING HEAVY MAINTENANCE PAC #3 DOOR OUTER UPPER SKIN HAS A HOLE IN IT. ACCOMPLISHED REPAIR ON PAC #3 DOOR OUTER UPPER SKIN IAW MD-11 SRM 52-00-00-20-0, SRM 52-40-01, REPAIR 1, SRM 51-33-01 AND BOEING REPAIR SKETCH: WGN-WGN-25-0020-01C. RECEIVED FINAL APPROSDR SWIA2025082500414Skin · chafedEXTERNAL SKIN ON FUSELAGE FS1015-FS1047 STGR26R-25R HAS MULTIPLE CHAFES (C-CHECK RO 8/21/2025) BLENDED CHAFES ON FUSELAGE EXTERNAL SKIN BETWEEN FS1015-FS1047 & STGR26R-25R IAW CRJ900 SRM 51-12-00-001-001-A01 AND COMPLIED WITH ALL STEPS OF REO 690-53SDR SWI2025F00949Housing · gougedAFT CARGO DOOR EXTERIOR HANDLE HOUSING IS GOUGED IN MULTIPLE AREAS. (C-CHECK RO 07/16/2025)REPLACED AFT CARGO DOOR EXTERIOR HANDLE HOUSING ASSY. REF CRJ900 SRM 51-42-21-001-001-A01 AND DWG CC670-38702 REV. F. LEAK CHECK GOOD. COMPLIED WITH 51-900-1002-SKY. OSDR SWI2025F00948Stringer · corrodedCORROSION ON STRINGER 18R BETWEEN FS661 AND FS661+16. REPAIRED STRINGER 18R BETWEEN FS661.00 AND FS661+16 REF REO 690-53-31-994 REV-- DATED 2025-06-03 ALL STEPS COMPLIED WITHCOMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWI2025F00947Tie Down · corrodedFWD BAGGAGE BAY NET TIE DOWN BRACKET HAS CORROSION IN MULTIPLE LOCATIONS AT APPROX FS565 BETWEEN STGR 22L AND STGR 23L. )INSTALLED NEW TIE DOWN BRACKET IAW SRM 51-42-21-001-001-A01 AND DWG SH670-33600 REV -AD. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.SDR SWI2025F00946Bracket · corrodedFWD BAGGAGE BAY NET TIE DOWN BRACKET HAS CORROSION IN MULTIPLE LOCATIONS AT APPROX FS517 BETWEEN STGR 26L AND STGR 27. REPLACED FWD BAGGAGE BAY NET TIE DOWN BRACKET AT APPROX FS517 BETWEEN STGR 26L AND STGR27, REF. SRM 51-42-21-001-001-A01 AND SRM 51-42-22-0SDR SWI2025F00945Stringer · corrodedCORROSION ON STRINGER 24R BETWEEN FS661+16 AND FS661+32. COMPLIED WITH REO 690-53-31-997 REV -- DATE 2025-06-13 TO REPAIR CORROSION ON STR 24R BETWEEN FS 661+16 & FS 661+32 AND FWD OF FS 661+16..COMPLIED WITH 51-900-1002-SKY.SDR SWIA202507160414Longeron · nickedRIGHT OVERWING LONGERON NICKED BETWEEN FS807.00 - FS817.00 APPROXIMATELY, ON INBOARD LOWER SIDE AS MARKED (C-CHECK RO 07/15/2025)BLENDED DAMAGE AND FOUND OUT OF LIMITS. REPAIRED PER MHIRJ REO 690-53-41-537 REV. -- DATE: 2025-05-19. SEE CONTINUATION CARD FOR DESDR SWIA2025070200414Roller · wornLH SLAT TRACK 3-3 UPPER OUTBOARD AFT ROLLER WORN. REMOVED AND REPLACED LH SLAT TRACK 3-3 TOP OUTBOARD AFT ROLLER REF AMM 27-81-43-000-806-A01 AND 27-81-43-400-806-A01.SDR AALA202506135460Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND LATERAL WINDOW FRAME HORIZONTAL UPPER STIFFENER FR4 LH L= 0.125 IN. MAINTENANCE PERFORMED TIME LIMITED REPAIR LOC LATERAL WINDOW FRAME HORIZONTAL UPPER STIFFENER FR 4 LH AND Y511 IAW EA 364298 AND A319 SRM 5SDR IPXA2025052507731Frame · crackedCRACK FOUND IN HOLE G ON FR47 LH HORIZONTAL JUNCTION. COMPLIED WITH STEP 15 OF PRELIM 1 EA-300-5710-27-A3893.SDR IPXA2025052508352Floor Support · crackedMDC FLOOR STRUCTURE RH SIDE FR38.1 SUPPORT (DOG BONE) CRACKED. DOT 11-056 THE SPARE PART IS CONSUMABLE AND DOES NOT HAVE A UPS PARTS TAG. (SEE ATTACHMENT).SDR IPXA2025060308262Floor Support · crackedMDC FLOOR STRUCTURE RH SIDE FR38.2 SUPPORT (DOG BONE) CRACKED.SDR SWI2025F00694Skin · dentedREPAIR FOR DENTS TO LOWER FUSELAGE SKIN BETWEEN FS625.30 - FS640.00 AND STR24L - STR27. (C-CHECK RO 05/28/2025)COMPLIED WITH REO 601R-53-61-8315 DATED: 2025-04-18 REPAIR FOR DENTS TO LOWER FUSELAGE SKIN BETWEEN FS625.30 - FS640.00 AND STR24L - STR27. COMPLETSDR SWIA20250530414Skin · dentedDENT TO LOWER FUSELAGE SKIN BETWEEN FS574.00 - FS589.00 AND STR24L - STR25L. (C-CHECK RO 05/28/2025)COMPLIED WITH REO 601R-53-61-8314 REV "--" DATED 2025-05-22 REPAIR FOR DENT TO LOWER FUSELAGE SKIN AND FOR CORROSION TO STRINGER BETWEEN FS574.00 - FS589.00 SDR VNAA20250525030Stringer Splice · corrodedAFTER SPLICE REMOVAL CORROSION ON SPLICE STGR 26 RH FS 333.00 WAS FOUND. SPLICE STGR 26 RH FS 333.00 WAS EVALUATED OUT OF LIMITS AND REPLACED PER CRJ700 SRM 53-00-00-101-001-A01 AND MUST BE INSTALLED UNDER NRC 00193.SDR IPXA2025052307518Crossbeam · bentMAIN DECK CROSSBEAM AT FR 48 BETWEEN -Y450 AND -Y953 BENT.DOT# 110-61 JP-110. INSTALLED NEW CROSSBEM I.A.W A300-600 SREO 75878-REQ001.SDR IPXA2025052395256Bracket · gougedLH WING, UPPER SURFACE, ATTACHMENT WTB FAIRIG AREA, BRACKET SUPPORT HAS GOUGE (2EA). DOT 103-34 (ATTACHED PHOTO). NSTALLED NEW BRACKET IAW A300-600 SRM 51-40-21. RIVET P/N: CR3213-6-03 BATCH: 0004194656, HI-LOCK P/N: DAN5-6-6 BATCH: 0004178101, COLLAR P/N: NSSDR IPXA2025052307579Crossbeam · bentMAIN DECK CROSSBEAM AT FR 49 BETWEEN -Y450 AND -Y953 BENT. DOT# 110-62 JP-110. INSTALLED NEW CROSSBEM I.A.W A300-600 SREO 75878-REQ001. REVIEWEDSDR SWAA2025051957378Access Panel · crackedCRACK SEAL - PLATE ACCESS PANEL 333AT AT LT HORIZONTAL STAB 2025-250486<[01] REPLACED BLADE ON ACCESS PANEL 333AT AT LT HORIZONTAL STAB IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG: 186A3101 SHEET: 19 REV - ; FOR INSTALLATION SEE FAULT TTG8Q00ZFCLW;[SDR SWAA2025051956464Doubler · crackedEGPR SURROUND DOUBLER IS CRACKED BS233 WL175 8' ABOVE S-24R MARKED<[01] TRIMMED OUT THE DAMAGED AREA OF THE EGPR SURROUND DOUBLER IAW SRM 53-10-15-2R-4 REPAIR 4 PARG 4(C); FABRICATED -2 DOUBLER; MADE FROM 2024T3#0.050 LOT# 1558343-1 AND -3 FILLER; MADE FROM 20SDR SWAA2025051957380Rib · crackedCRACK LEADING EDGE RIB LOCATED LE STA 95.96 AT RT HORIZONTAL STABILIZER. REPLACED RIB LOCATED LE STA 95.96 AT RT HORIZONTAL STABILIZER IAW B737-700 SRM 51-10-02-0G PARAGRAPH 9; SRM 51-40-02-0G AND DWG: 186A1001; SHEET: 19; REV: -.SDR SWAA2025051957381Access Panel · crackedCRACK LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA 105.26 AT LT HORIZONTAL STABILIZER 2025-250492<[01] REPLACED LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA 105.26 AT LT HORIZONTAL STABILIZER IAW B737-700 SRM 51-40-02 AND DWG:186A1001 SHEET: 19; REV:SDR SWAA2025051456764Stub Frame · crackedCRACK FOUND ON FSD STUB FRAME AT BS 291.5+8; .2' ABOVE SEAL DEPRESSOR; 1.6' IN LENGTH<[01] EVALUATED DAMAGE; NO ALLOWABLE DAMAGE FOUND AT SRM; UPPER STUB FRAME TO BE REPAIRABLE BY REPLACEMENT PER SRM 51-10-02; STEP 9. REMOVED FWD SERVICE DOOR UPPER STUB FRAME SDR SWAA2025051456759Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT NUTPLATE HOLE RBL 43; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.;[03] CHANGED MEASUREMENTS FIELD ON RII TO NO AND MAJOR REPAIR TO NO DAMAGE REPAIRED OSDR SWAA2025051456760Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT BOTTOM SIDE OF NUTPLATE HOLE RBL 35.5; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.SDR SWAA2025051456761Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT BOTTOM SIDE OF NUTPLATE HOLE RBL 31.5; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.SDR SWAA2025051456762Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT BOTTOM SIDE OF NUTPLATE HOLE RBL 27.5; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.SDR SWAA2025051251345Bracket · crackedLT WING CONDUIT BRACKET ABOVE AND AFT OF MLG MAIN RETRACT ACTUATOR CRACKED. SEE ATTACHED PICS.<[01] REMOVED AND REPLACED CONDUIT BRACKET. IAW SRM 51-40-02;[02] 02 - INSPECTED PER [SRM 51-40-02-0G-0-B00069 (GENERAL - FASTENER INSTALLATION AND REMOVAL - AIRFRAMESDR ASAA2025041457773Bushing · out of roundLH HORIZONTAL REAR SPAR, AFT FAILSAFE LUG & CLEVIS BUSHINGS ARE OUT OF ROUND. GROUNDED - YES. ACCOMPLISHED ASA EA CMPT-55EA-28559.SDR SWI2025F00629Floor Support · corrodedCORROSION, AFT WET AREA, ON RH INTERCOSTAL BETWEEN FRAMES 89 AND 90. (C-CHECK RO 05/05/2025)REMOVED AND REPLACED AFT WET AREA RH INTERCOSTAL BETWEEN FRAMES 89 AND 90. REF SRM 51-40-08.(SEE CONTINUE CARD FOR ALL WORK ACCOMPLISHED.)FACTORY REPLACEMENT PARTS NO SDR SWI2025F00628Floorbeam · corrodedCORROSION, AFT WET AREA, ON RH LONGITUDINAL FLOOR BEAM AT FRAME 87 WHERE THE BEAM PASSES BETWEEN THE CENTER AND RH SHEAR PANELS AND FORWARD END AT FR 88. (C-CHECK RO 05/05/2025)REMOVED AND REPLACED AFT WET AREA RH LONGITUDINAL FLOOR BEAM REF EMB SRM 51-40-08.SDR SWI2025F00627Floorbeam · corrodedCORROSION, AFT WET AREA, ON LH LONGITUDINAL FLOOR BEAM AT FRAME 87 WHERE THE BEAM PASSES BETWEEN THE LH AND CENTER SHEAR PANELS. (C-CHECK RO 05/05/2025) REMOVED AND REPLACED AFT WET AREA, ON LH LONGITUDINAL FLOOR BEAM AT FRAME 87 WHERE THE BEAM PASSES BETWEESDR SWIA20250506414Rib · crackedRH HORIZONTAL STABILIZER RIB 12A HAS A SUSPECTED CRACK ALONG AFT EDGE OF THE UPPER FORWARD FLANGE. (C-CHECK RO 05/05/2025)REMOVED AND REPLACED RH HORIZONTAL STABILIZER RIB 12A REF ETD2025-170-906560 AND EMB SRM 51-40-08 O.E.M. PART INSTALLED NO CHANGE TO WEIGSDR ASAA2025041457694Bushing · out of roundLH HORIZONTAL REAR SPAR, AFT FAILSAFE LUG & CLEVIS BUSHINGS ARE OUT OF ROUND. GROUNDED - YES. ACCOMPLISHED ASA EA CMPT-55EA-28559.SDR IPXA2025042908379Floor Panel · damagedMDC FLOOR PANEL 231KJ IS DAMAGED AND BROKEN. FABRICATED MAIN DECK FLOOR PANEL 231KJ IAW SREO-16407-REQ001.SDR 2025FA0000336Terminal Block · faultedPILOT NOTED THE SMELL OF OZONE OR ELECTRICAL CIRCUIT GETTING HOT WHILE DEPARTING NK-71. NO SMOKE OR SYSTEM FAILURE WAS INDICATED. AS HE WAS STILL NEAR BASE OF OPERATION, AT NIGHT OVER A HEAVILY WOODED AREA HE DECIDED TO RETURN TO BASE. DURING INSPECTION THE BSDR 9WGA2025042954622Inlet · corroded#3 INLET HAS PITTING CORROSION AT 11 O'CLOCK POS. REMOVED MILD SURFACE CORROSION AND LITE PITTING BY HAND RUBBING ON #3 INLET AT 11 O'CLOCK POSITION. FOUND WITHIN LIMITS IAW MD-11 SRM 54-12-02-1A-0, FIGURE 103 DETAIL IV AND SRM 51-21-01. NO MATERIAL LOSS ATSDR 9WGA2025042954621Inlet · corroded#3 INLET HAS PITTING CORROSION BETWEEN 8 & 9 O'CLOCK POS. REMOVED MILD SURFACE CORROSION AND LITE PITTING BY HAND RUBBING ON #3 INLET BETWEEN 8 AND 9 O'CLOCK POSITION. FOUND WITHIN LIMITS IAW MD-11 SRM 54-12-02-1A-0, FIGURE 103 DETAIL Q AND SRM 51-21-01. NOSDR 9WGA2025042954620Inlet · corroded3# INLET HAS PITTING CORROSION AT 3 O'CLOCK POS. REMOVED MILD SURFACE CORROSION AND LITE PITTING BY HAND RUBBING ON #3 INLET AT 3 O'CLOCK POSITION. FOUND WITHIN LIMITS IAW MD-11 SRM 54-12-02-1A-0, FIGURE 103, DETAIL IV AND SRM 51-21-01. NO MATERIAL LOSS AT SDR 9WGA2025042954619Inlet · corroded#3 INLET HAS PITTING CORROSION BETWEEN 5 & 6 O'CLOCK POS. REMOVED MILD SURFACE CORROSION AND LITE PITTING BY HAND RUBBING ON #3 INLET BETWEEN 5 & 6 O'CLOCK POSITION. FOUND WITHIN LIMITS IAW MD-11 SRM 54-12-02. NO MATERIAL LOSS AT THIS TIME. O. ARILA D0011. SDR 9WGA2025042954618Ring · corroded#3 ENGINE CONTAINMENT RING FWD SIDE HAS CORROSION @ THE 8 O'CLOCK POSITION.SDR 9WGA2025042854617Ring · corrodedDURING HEAVY MAINTENANCE CHECK NR 1 ENGINE CONTAINMENT RING FWD SIDE HAS CORROSION @ 8 O'CLOCK POSITION. ACCOMPLISHED WITH ENGINE REMOVAL AND REPLACEMENT IAW MD-11 T/C: MS-71-00-01-00-00-01-WG, SEQ,1,W/O# 15701 AND AMM 71-00-03-000-801. THE AIRCRAFT WAS APPRSDR 9WGA2025042854616Ring · corrodedDURING HEAVY MAINTENANCE CHECK NR 2 ENGINE L/E OF CONTAINMENT RING HAS CORROSION AROUND BOTTOM HALF. ACCOMPLISHED WITH ENGINE REMOVAL ANF REPLACEMENT IAW MD-11 T/C: MS-71-00-03-00-00-01-WG, SEQ, W/O# 15700 AND AMM 71-00-03-000-801.THE AIRCRAFT WAS APPROVED FO