Page 172OCROpen in PDF

"А" „040I 2017-T3 SPACER 2D, 3D 3D 202D 3D 3D 20 "В" 2024-T3 SPLICE BAR "Д" "В ". 9120 ---- ti 2117-AD RIVETS 3/32" DIA. MIN. - CRACK 2117-AD RIVETS 3/32" DIA. MIN. 4→ Д

- ЗА ЗА I. STRAIGHTEN CRIMPED OVER PORTION. CRACK

2. INSERT HARDWOOD (ASH) INSERT SHAPED.

TO CONFORM TO T.E. PIECE.

2117-AD RIVETS 20 20 20 2D D 3/32" DIA. MIN.

FLATTEN HEADS (APPROX. 1.5 ₺ ) OUTSIDE

1. STRAIGHTEN CRIMPED PORTION. - CRACK

2. USE SAME AL. ALLOY AS IN ORIGINAL.

NOTE: FOR MINIMUM NUMBER OF RIVETS REQUIRED, SEE PARAGRAPH 4-58g AND SUBSEQUENT.

FIGURE 4-15. Typical repairs of trailing edges.

Par 4-58 Page 4-31

Page 173OCROpen in PDF

(A) ADDED

STIFFENERS TO →15% 2 EACH BACK UP SEAM 24-5/32" PREQ'D OF PATCH.

2117-T4 BACKED PATCH PLATE

BY SAME TO BE OF SAME RIVETS †22-12 MATERIAL AS

ORIGINAL AND 3" HOLE MAX. DIA. HOLE MAX DIA. SAME OR NEXT HEAVIER GAUGE.

16-5/32" RIVET SIZE, -2117-T4 RIVETS SPACING,

MATERIAL, AND

PATTERN "G", "H", AND "K SAME AS ARE ORIGINAL A B.

CIRCULAR PATCH PLATES. DAMAGED SKIN DIMENSIONS OF CIR. PATCH PLATES SHOULD BE DESIGNATION "K" "H" "G" CLEANED OUT DIAMETER (OUTSIDE) 2-1/2" 5" 7-12" SMOOTHLY AS DIA. INNER RIVET CIRCLE 1-3/4" 3" 4" INDICATED BY DIA. OUTER RIVET CIRCLE 4" 6-1/2" CDEF.

SAME RIVET SIZE, SPACING, MATERIAL, & PATTERN AS B C.

SAME RIVET SIZE, SPACING, MATERIAL, & PATTERN AS A D.

PATCH PLATE

TO BE OF SAME

•1" HOLE MATERIAL AS 8-5/32" 2 MAX DIA. ORIGINAL AND

RI SAME OR NEXT

HEAVIER GAUGE CRACK D 2 TIMES LENGTI NOT LESS THAN -PORTION OF SKIN REPLACED OF CRACK:

- ORIGINAL SKIN SHEET. "4 RIVETS REQD. EACH SIDE.

RIVET SPACING AT LEAST 3X RIVET DIA

HOLES DRILLED TO PREVENT CRACK SPREADING.

SKIN GAUGE = .028" (B) RIVET DIA. = 1/8" CRACK 2.5" LONG' FIGURE 4-16. Typical repairs of stressed sheet metal coverings. (Refer to tables 4-9, 4-10, and 4-11 to calculate number of rivets to be used.)

Page 4-32 Par 4-58

Page 174OCROpen in PDF

86/8/6 AC 43.13-1B ....•......

ITAPERED SPLICE MEMBER NOTE: UNSHADED SECTIONS ARE ORIGINAL AND/OR REPLACEMENT SECTIONS. SHADED SECTIONS ARE CONNECTING OR REINFORCING SECTIONS.

NOTE: FOR MINIMUM NUMBER OF RIVETS REQUIRED, SEE PARAGRAPH 4-58g AND SUBSEQUENT.

FIGURE 4-17. Typical stringer and flange splices.

Par 4-58 Page 4-33

Page 175OCROpen in PDF

CUT IN STRINGER TAPERED SPLICE MEMBER 0-0

ON LOWER SURFACE OF WING, MAKE END RIVET SAME SIZE AS SKIN ATTACHING RIVETS.

2 oz, MINIMUM 3 dz, MINIMUM -

THE NUMBER OF BOLTS REQUIRED IN THE "BULB" LEG OF THE STRINGER IS DETERMINED FROM TABLE 4-9 FOR 2017-T3 AS FOLLOWS:

+z= 1/16" (Use .064") de= .190 (AN3 bolt) NO. OF BOLTS PER INCH OF WIDTH FROM TABLE = 3.3.

ACTUAL NO. OF BOLTS ON EACH SIDE OF CUT = WX 3.3 = (1.0) × 3.3 = 3.3 BOLTS USE 4 BOLTS

WHEN BOTH RIVETS AND BOLTS

ARE USED, BOLT HOLES SHOULD BE REAMED TO SIZE. (ź) -KEEP LARGE HOLES BACK FROM END OF SPLICE.

THE NUMBER OF RIVETS REQUIRED IN

THE UPPER LEG OF THE STRINGER IS DETERMINED FROMTABLE 4-9 FOR 2017-T3 AS FOLLOWS:

t, = 1/16" (Use „064") d,= 1/8" (2117-AD rivet) NO. OF RIVETS PER INCH OF WIDTH FROM TABLE = 9.9 ACTUAL NO. OF RIVETS ON EACH SIDE OF CUT = WIx 9.9 = (.5) × 9.9 = 4.95 RIVETS. USE 5 RIVETS.

d, (1/8), RIVET DIA. PREFERABLY 12tTO 3t, BUT NOT GREATER THAN W/4.

Wz.

(1.0)

- "B" SPLICE BAR. SHADED AREA SPLICE ANGLE "A" dz (16). GREATER THAN W, Xt,.

SHADED AREA GREATER THAN W2xt2. STRINGER

AREA REPRESENTING BULB

SECTION A-A FIGURE 4-18. Example of stringer splice (material-2017 alloy).

Page 4-34 Par 4-58

Page 176Open in PDF

NOTE: FOR MINIMUM NUMBER OF RIVETS REQUIRED, SEE PARAGRAPH 4-58g AND SUBSEQUENT.

NOTE: STRENGTH INVESTIGATION IS USUALLY REQUIRED FOR THIS TYPE OF REPAIR.

FIGURE 4-19. Application of typical flange splices and reinforcement.

Par 4-58 Page 4-35

Page 177Open in PDF

(3) To avoid concentration of load on the end rivet and consequent tendency toward progressive rivet failure, the splice is tapered at the ends by tapering the backing angle and by making it shorter than the splice bar. (See fig­ ure 4-18.)

(4) The preceding principles are espe­ cially important in splicing stringers on the lower surface of stressed skin wings, where high-tension stresses may exist. When several adjacent stringers are spliced, stagger the splices if possible.

k. Size of Splicing Members. When the same material is used for the splicing members as for the original member, the cross-section area (i.e., the shaded areas in figure 4-17), of the splice material will be greater than the area of the section element which it splices. The area of a section element (e.g., each leg of an angle or channel) is equal to the width multi­ plied by the thickness. For example, the bar “B” in figure 4-18 is assumed to splice the up­ per leg of the stringer, and the angle “A” is as­ sumed to splice the bulbed leg of the stringer.

Since the splice bar “B” is not as wide as the adjacent leg, its thickness must be increased such that the area of bar “B” is at least equal to the area of the upper leg of the stringer.

l. The Diameter of Rivets in Stringers .

The diameter of rivets in stringers might pref­ erably be between two and three times the thickness “t” of the leg, but must not be more than 1/4th the width “W” of the leg. Thus, 1/8-inch rivets are chosen in the example, fig­ ure 4-18. If the splices were in the lower sur­ face of a wing, the end rivets would be made the same size as the skin-attaching rivets, or 3/32 inch.

m. The Number of Rivets . The number of rivets required on each side of the cut in a stringer or flange may be determined from standard text books on aircraft structures, or may be found in tables 4-9 through 4-11.

(1) In determining the number of rivets required in the example, figure 4-18, for at­ taching the splice bar “B” to the upper leg, the thickness “t” of the element of area being spliced is 1/16 inch (use 0.064), the rivet size is 1/8 inch, and table 4-9 shows that 9.9 rivets are required per inch of width. Since the width “W” is 1/2 inch, the actual number of rivets required to attach the splice bar to the upper leg on each side of the cut is 9.9 (rivets per inch) x 0.5 (inch width) = 4.95 (use 5 rivets).

(2) For the bulbed leg of the stringer “t” = 1/16 inch (use 0.064); AN-3 bolts are chosen, and the number of bolts required per inch of width = 3.3. The width “W” for this leg, however, is 1 inch; and the actual number of bolts required on each side of the cut is 1 x 3.3 = 3.3 (use 4 bolts). When both rivets and bolts are used in the same splice, the bolt holes must be accurately reamed to size. It is preferable to use only one type of attachment, but in the above example, the dimensions of the legs of the bulb angle indicated rivets for the upper leg and bolts for the bulb leg.

n. Splicing of Intermediate Frames.

The same principles used for stringer splicing may be applied to intermediate frames when the following point is considered. Conven­ tional frames of channel or Z sections are rela­ tively deep and thin compared to stringers, and usually fail by twisting or by buckling of the free flange. Reinforce the splice joint against this type of failure by using a splice plate heavier than the frame and by splicing the free flange of the frame with a flange of the splice plate. (See figure 4-20.) Since a frame is likely to be subjected to bending loads, make the length of splice plate “L” more than twice the width “W 2,” and the rivets spread out to cover the plate.

Page 4-36 Par 4-58

Page 178Open in PDF

TABLE 4-9. Number of rivets required for splices (single-lap joint) in bare 2014-T6, 2024-T3, 2024-T36, and 7075-T6 sheet, clad 2014-T6, 2024-T3, 2024-T36, and 7075-T6 sheet, 2024-T4, and 7075-T6 plate, bar, rod, tube, and extrusions, 2014-T6 extrusions.

Thickness “t” in inches No. of 2117-T4 (AD) protruding head rivets required per inch of width “W” No. of Bolts Rivet size 3/32 1/8 5/32 3/16 1/4 AN-3 .016 6.5 4.9 - ­ - ­ - ­ - ­ .020 6.9 4.9 3.9 - ­ - ­ - ­ .025 8.6 4.9 3.9 - ­ - ­ - ­ .032 11.1 6.2 3.9 3.3 - ­ - ­ .036 12.5 7.0 4.5 3.3 2.4 - ­ .040 13.8 7.7 5.0 3.5 2.4 3.3 .051 - ­ 9.8 6.4 4.5 2.5 3.3 .064 - ­ 12.3 8.1 5.6 3.1 3.3 .081 - ­ - ­ 10.2 7.1 3.9 3.3 .091 - ­ - ­ 11.4 7.9 4.4 3.3 .102 - ­ - ­ 12.8 8.9 4.9 3.4 .128 - ­ - ­ - ­ 11.2 6.2 3.2 NOTES:

a. For stringers in the upper surface of a wing, or in a fuselage, 80 percent of the number of rivets shown in the table may be used.

b. For intermediate frames, 60 percent of the number shown may be used.

c. For single lap sheet joints, 75 percent of the number shown may be used.

ENGINEERING NOTES:

a. The load per inch of width of material was calculated by assuming a strip 1 inch wide in tension.

b. Number of rivets required was calculated for 2117-T4 (AD) rivets, based on a rivet allowable shear stress equal to 40 percent of the sheet allowable tensile stress, and a sheet allowable bearing stress equal to 160 percent of the sheet allowable tensile stress, using nominal bolt diameters for rivets.

c. Combinations of sheet thickness and rivet size above the underlined numbers are critical in (i.e., will fail by) bearing on the sheet; those below are critical in shearing of the rivets.

d. The number of AN-3 bolts required below the underlined number was calculated based on a sheet allowable tensile stress of 70,000 psi and a bolt allowable single shear load of 2,126 pounds.

Par 4-58 Page 4-37

Page 179Open in PDF

TABLE 4-10. Number of rivets required for splices (single-lap joint) in 2017, 1017 ALCLAD, 2024-T3 ALCLAD sheet, plate, bar, rod, tube, and extrusions.

Thickness “t” in inches No. of 2117-T4 (AD) protruding head rivets required per inch of width “W” No. of Bolts Rivet size 3/32 1/8 5/32 3/16 1/4 AN-3 .016 6.5 4.9 - ­ - ­ - ­ - ­ .020 6.5 4.9 3.9 - ­ - ­ - ­ .025 6.9 4.9 3.9 - ­ - ­ - ­ .032 8.9 4.9 3.9 3.3 - ­ - ­ .036 10.0 5.6 3.9 3.3 2.4 - ­ .040 11.1 6.2 4.0 3.3 2.4 - ­ .051 - ­ 7.9 5.1 3.6 2.4 3.3 .064 - ­ 9.9 6.5 4.5 2.5 3.3 .081 - ­ 12.5 8.1 5.7 3.1 3.3 .091 - ­ - ­ 9.1 6.3 3.5 3.3 .102 - ­ - ­ 10.3 7.1 3.9 3.3 .128 - ­ - ­ 12.9 8.9 4.9 3.3 NOTES:

a. For stringers in the upper surface of a wing, or in a fuselage, 80 percent of the number of rivets shown in the table may be used.

b. For intermediate frames, 60 percent of the number shown may be used.

c. For single lap sheet joints, 75 percent of the number shown may be used.

ENGINEERING NOTES:

a. The load per inch of width of material was calculated by assuming a strip 1 inch wide in tension.

b. Number of rivets required was calculated for 2117-T4 (AD) rivets, based on a rivet allowable shear stress equal to percent of the sheet allowable tensile stress, and a sheet allowable bearing stress equal to 160 percent of the sheet allowable tensile stress, using nominal hole diameters for rivets.

c. Combinations of sheet thickness and rivet size above the underlined numbers are critical in (i.e., will fail by) bearing on the sheet; those below are critical in shearing of the rivets.

d. The number of AN-3 bolts required below the underlined number was calculated based on a sheet allowable tensile stress of 55,000 psi and a bolt allowable single shear load of 2,126 pounds.

Page 4-38 Par 4-58

Page 180Open in PDF

TABLE 4-11. Number of rivets required for splices (single-lap joint) in 5052 (all hardnesses) sheet.

Thickness “t” in inches No. of 2117-T4 (AD) protruding head rivets required per inch of width “W” No. of Bolts Rivet size 3/32 1/8 5/32 3/16 1/4 AN-3 .016 6.3 4.7 - ­ - ­ - ­ .020 6.3 4.7 3.8 - ­ - ­ - ­ .025 6.3 4.7 3.8 - ­ - ­ - ­ .032 6.3 4.7 3.8 3.2 - ­ - ­ .036 7.1 4.7 3.8 3.2 2.4 - ­ .040 7.9 4.7 3.8 3.2 2.4 - ­ .051 10.1 5.6 3.8 3.2 2.4 - ­ .064 12.7 7.0 4.6 3.2 2.4 - ­ .081 - ­ 8.9 5.8 4.0 2.4 3.2 .091 - ­ 10.0 6.5 4.5 2.5 3.2 .102 - ­ 11.2 7.3 5.1 2.8 3.2 .128 - ­ - ­ 9.2 6.4 3.5 3.2 NOTES:

a. For stringers in the upper surface of a wing, or in a fuselage, 80 percent of the number of rivets shown in the table may be used.

b. For intermediate frames, 60 percent of the number shown may be used.

c. For single lap sheet joints, 75 percent of the number shown may be used.

ENGINEERING NOTES:

a. The load per inch of width of material was calculated by assuming a strip 1 inch wide in tension.

b. Number of rivets required was calculated for 2117-T4 (AD) rivets, based on a rivet allowable shear stress equal to 70 percent of the sheet allowable tensile stress, and a sheet allowable bearing stress equal to 160 percent of the sheet allowable tensile stress, using nominal hole diameters for rivets.

c. Combinations of sheet thickness and rivet size above the underlined numbers are critical in (i.e., will fail by) bearing on the sheet, those below are critical in shearing of the rivets.

Par 4-58 Page 4-39

Page 181Open in PDF

4-59. REPAIRING CRACKED MEM­ BERS. Acceptable methods of repairing vari­ ous types of cracks in structural elements are shown in figures 4-21 through 4-24. The fol­ lowing general procedures apply in repairing such defects.

a. Drill small holes 3/32 inch (or 1/8 inch) at the extreme ends of the cracks to minimize the possibility of their spreading further.

b. Add reinforcement to carry the stresses across the damaged portion and to stiffen the joints. (See figures 4-14 through

4-17.) The condition causing cracks to de­ velop at a particular point is stress concentra­ tion at that point in conjunction with repetition of stress, such as produced by vibration of the structure. The stress concentration may be due to the design or to defects such as nicks, scratches, tool marks, and initial stresses or cracks from forming or heat-treating opera­ tions. It should be noted, that an increase in sheet thickness alone is usually beneficial but does not necessarily remedy the conditions leading to cracking.

4-60. STEEL AND ALUMINUM FIT­ TINGS.

a. Steel Fittings. Inspect for the follow­ ing defects.

(1) Fittings are to be free from scratches, vise and nibbler marks, and sharp bends or edges. A careful examination of the fitting with a medium power (at least 10 power) magnifying glass is acceptable as an inspection.

(2) When repairing aircraft after an ac­ cident or in the course of a major overhaul, in­ spect all highly-stressed main fittings, as set forth in the manufacturer’s instruction manual.

(3) Replace torn, kinked, or cracked fit­ tings.

(4) Elongated or worn bolt holes in fit­ tings, which were designed without bushings, are not to be reamed oversize. Replace such fittings, unless the method of repair is ap­ proved by the FAA. Do not fill holes with welding rod. Acceptable methods of repairing elongated or worn bolt holes in landing gear, stabilizer, interplane, or cabane-strut ends are shown in figure 4-25.

b. Aluminum and Aluminum Alloy Fit­ tings.

(1) Replace damaged fittings with new parts that have the same material specifica­ tions.

(2) Repairs may be made in accordance with data furnished by the aircraft manufac­ turer, or data substantiating the method of re­ pair may be submitted to the FAA for ap­ proval.

4-61. CASTINGS. Damaged castings are to be replaced and not repaired unless the method of repair is specifically approved by the air­ craft manufacturer or substantiating data for the repair has been reviewed by the FAA for approval.

4-62. SELECTIVE PLATING IN AIR­ CRAFT MAINTENANCE. Selective plating is a method of depositing metal from an elec­ trolyte to the selected area. The electrolyte is held in an absorbent material attached to an in­ ert anode. Plating contact is made by brushing or swabbing the part (cathode) with the elec­ trolyte-bearing anode.

a. Selective Plating Uses . This process can be utilized for any of the following rea­ sons.

Page 4-40 Par 4-59

Page 182Open in PDF

THE NUMBER OF RIVETS REQUIRED IN EACH LEG ON EACH SIDE OF THE CUT IS DETERMINED BY THE WIDTH “W,” THE THICKNESS OF THE FRAME “t,” AND THE RIVET DIAMETER “d” USING TABLE 4- 10 IN A MANNER SIMILAR TO THAT FOR STRINGERS IN FIGURE 4 -

20.

NOTE b. IN TABLE 4-10 INDICATES THAT ONLY 60 PERCENT OF

THE NUMBER OF RIVETS SO CALCULATED NEED BE USED IN SPLICES IN INTERMEDIATE.

EXAMPLE: (FOR 2017-T3 aluminum alloy frame)

FLANGE LEG t = .040”

d = 1/8” 2117-T4 (AD)

W1 & W 3 = .6 inch

NO. OF RIVETS PER INCH OF WIDTH

FROM TABLE 4-10 = 6.2

No. of rivets required = W x 6.2 =

.6 x 6.2 = 3.72 or 4 rivets.

60 percent of 4 rivets = 2.4 rivets.

USE 3 RIVETS ON EACH SIDE OF THE

CUT IN EACH FLANGE LEG.

WEB OF ZEE (OR CHANNEL) t = .040” d = 1/8” 2117-T4 (AD) rivet W = 2.0 inches NO. OF RIVETS PER INCH OF WIDTH FROM TABLE 4-10 = 6.2 No. of rivets required = W x 6.2 =

2.0 x 6.2 = 12.4 or 13 rivets.

60 percent of 13 rivets = 7.8 rivets.

USE 8 RIVETS ON EACH SIDE OF CUT

IN THE WEB OF ZEE (OR CHANNEL).

“L” SHOULD BE MORE THAN TWICE W2

Thickness of splice plate to be greater than that of the frame to be spliced.

FIGURE 4-20. Example of intermediate frame stringer splice (material 2017-T3 AL alloy).

Par 4-62 Page 4-41

Page 183OCROpen in PDF

CHANNELS

TRAILING EDGE

FORWARD

HORIZONTAL RIBS SKIN

OVERTARL CRACKS CRACKS ANCHOR

NUTS FOR RIB

ATTACH-

MENT OF

FIN TO SKIN

STABILIZER

AND TIP

TO FIN CRACK TRAILING EDGE ¡ 0

REAR SHEAR

FRONT BEAM SPAR CRACKS

LEADING

EDGE AILERON NOTE: ALL REINFORCING PLATES TO BE OF REAR SAME ALLOY & APPROX. 1.5 THICKNESS OF ORIGINAL FIGURE 4-21. Typical methods of repairing cracked leading and trailing edges and rib intersections.

Page 4-42 Par 4-62