CONTENTS (CONTINUED) Paragraph Page SECTION 2. STORAGE BATTERIES
11-15. General11-5
11-16. Battery Charging11-5
11-17. Battery Freezing11-5
Table 11-1. Lead-Acid Battery Electrolyte Freezing Points11-5
11-18. Temperature Correction11-5
Table 11-2. Sulfuric Acid Temperature Correction11-6
11-19. Battery Maintenance11-6
11-20. Electrolyte Spillage11-8
11-21. Noxious Fumes11-9
11-22. Installation Practices11-9
Figure 11-1. Battery Ventilating Systems11-9
11-23.11-29. [RESERVED.]11-10
SECTION 3. INSPECTION OF EQUIPMENT INSTALLATION
11-30. General11-11
11-31. Installation Clearance Provisions11-11
11-32. Wires, Wire Bundles, and Circuit Protective Devices11-11
11-33. Alternator Diodes11-11
11-34. Static Electrical Power Converters11-11
11-35. Acceptable Means of Controlling or Monitoring the Electrical Load11-12
11-36. Electrical Load Determination11-12
11-37. Junction Box Construction11-13
11-38.11-46. [RESERVED.]11-13
SECTION 4. INSPECTION OF CIRCUIT-PROTECTION DEVICES
11-47. General11-15
11-48. Determination of Circuit Breaker Ratings11-15
11-49. DC Circuit Protector Chart11-15
Table 11-3. DC Wire and Circuit Protector Chart11-15
11-50. Resettable Circuit Protection Devices11-15
11-51. Circuit Breaker Usage11-15
11-52. Circuit Breaker Maintenance11-16
11-53. Switches11-16
Table 11-4. Switch Derating Factors11-17
Table 11-5. Selection of Contact Material11-17
11-54. Relays11-19
11-55. Load Considerations11-20
11-56. Operating Conditions for Switches and Relays11-20
11-57.11-65. [RESERVED.]11-20
SECTION 5. ELECTRICAL WIRE RATING
11-66. General11-21
Table 11-6. Tabulation Chart (Allowable Voltage Drop)11-21
Table 11-7. Examples of Determining Required Wire Size Using Figure 11-211-22
Table 11-8. Examples of Determining Maximum Run Length Using Figure 11-311-22
Page xxvi
CONTENTS (CONTINUED) Paragraph Page
Table 11-9. Current Carrying Capacity and Resistance of Copper Wire11-23
Table 11-10. Current Carrying Capacity and Resistance of Aluminum Wire11-24
11-67. Methods for Determining Current Carrying Capacity of Wires11-25
11-68. Instructions for Use of Electrical Wire Chart11-25
11-69. Computing Current Carrying Capacity11-28
Figure 11-2. Conductor Chart, Continuous Flow11-30
Figure 11-3. Conductor Chart, Intermittent Flow11-31
Figure 11-4a. Single Copper Wire in Free Air11-32
Figure 11-4b. Single Copper Wire in Free Air11-33
Figure 11-5. Bundle Derating Curves11-34
Figure 11-6. Altitude Derating Curve11-34a
11-70.11-75. [RESERVED.]11-34a
SECTION 6. AIRCRAFT ELECTRICAL WIRE SELECTION
11-76. General11-35
11-77. Aircraft Wire Materials11-35
11-78. Substitutions11-36
11-79.11-84. [RESERVED.]11-37
SECTION 7. TABLE OF ACCEPTABLE WIRES
11-85. Aircraft Wire Table11-39
Table 11-11. Open Wiring11-40
Table 11-12. Protected Wiring11-41
11-86. Open Airframe Interconnecting Wire11-39
11-87. Protected Wire11-39
11-88. Severe Wind and Moisture Problems (SWAMP)11-39
11-89. Shielded Wire11-39
11-90. 11-95. [RESERVED.]11-41
SECTION 8. WIRING INSTALLATION INSPECTION REQUIREMENTS
11-96. General11-43
11-97. Wiring Replacement11-45
11-98. Terminals and Terminal Blocks11-46
11-99. Fuses and Fuse Holders11-47
11-100. Connectors11-47
11-101. Junction Boxes, Panels, Shields, and Microswitch Housings11-48
11-102. Conduit-Rigid Metallic, Flexible Metallic and Rigid Nonmetallic11-48
11-103. Junctions11-48
11-104. Circuit Breakers11-49
11-105. System Separation11-49
11-106. Electromagnetic Interference (EMI)11-49
11-107. Interference Tests11-49
11-108. Identification Stencils and Placards On Electrical Equipment11-50
11-109.11-114. [RESERVED.]11-50
Page xxvii
CONTENTS (CONTINUED) Paragraph Page SECTION 9. ENVIRONMENTAL PROTECTION AND INSPECTION
11-115. Maintenance and Operations11-51
Figure 11-9a. Slack Between Supports11-52a
Figure 11-9b. Drainage Hole in Low Point of Tubing11-52a
11-116. Group and Bundle Ties11-51
Figure 11-7. Group and Bundle Ties11-51
Figure 11-8. Comb for Straightening Wires in Bundles11-51
11-117. Minimum Wire Bend Radii11-51
11-118. Slack11-52
11-118a.Drip Loop in Wire Bundle11-52
11-119. Power Feeders11-52
11-120. RF Cable11-52
11-121. Precautions11-52
11-122. Moisture Protection, Wheel Wells, and Landing Gear Areas11-53
11-123. Protection Against Personnel and Cargo11-53
11-124. Heat Precautions11-53
11-125. Movable Controls Wiring Precautions11-53
11-126. Flammable Fluids and Gases11-53
Figure 11-10. Separation of Wires From Plumbing Lines11-54
11-127.11-134. [RESERVED.]11-55
SECTION 10. SERVICE LOOP HARNESSES (PLASTIC TIE STRIPS)
11-135. General11-55
11-136. Support11-55
11-137. Anti-Chafing Material11-55
11-138. Strain Relief11-55
11-139. Service Loop11-55
11-140.11-145. [RESERVED.]11-56
SECTION 11. CLAMPING
11-146. General11-57
Figure 11-11. Safe Angle for Cable Clamps11-58
Figure 11-12. Typical Mounting Hardware for MS-21919 Cable Clamps11-58
Figure 11-13. Installing Cable Clamp to Structure11-59
Figure 11-14. Clamping at a Bulkhead Hole11-60
11-147. Wire and Cable Clamps Inspection11-57
11-148.11-154. [RESERVED.]11-60
SECTION 12. WIRE INSULATION AND LACING STRING TIE
11-155. General11-61
11-156. Insulation Materials11-61
11-157. Stripping Insulation11-61
Table 11-13. Allowable Nicked or Broken Strands11-62
11-158. Lacing and Ties11-61
Figure 11-15. Single Cord Lacing11-63
Figure 11-16. Double Cord Lacing11-63
Figure 11-17. Making Ties11-64
11-159. Insulation Tape11-62
Page xxviii
CONTENTS (CONTINUED) Paragraph Page
11-160.11-166. [RESERVED.]11-64
Page xxviii-a (and xxviii-b)
CONTENTS (CONTINUED) Paragraph Page SECTION 13. SPLICING .
11-167 General11-65
Figure 11-18. Staggered Splices in Wire Bundle11-65
11-168.11-173. [RESERVED.]11-65
SECTION 14. TERMINAL REPAIRS
11-174. General11-67
11-175. Attachment of Terminals to Studs11-68
11-176. Studs and Insulators11-68
11-177. Wire Terminals and Binding Posts11-69
11-178. Crimp On Terminal Lugs and Splices11-69
11-179. Lock Washers for Terminals On Equipment11-70
11-180.11-184. [RESERVED.]11-70
SECTION 15. GROUNDING AND BONDING
11-185. General11-71
11-186. Grounding11-71
11-187. Bonding11-73
11-188. Bonding Inspection11-73
Figure 11-19. Millivolt Drop Test11-74
11-189. Bonding Jumper Installations11-75
Table 11-14. Stud Bonding or Grounding to Flat Surface11-76
Table 11-15. Plate Nut Bonding or Grounding to Flat Surface11-77
Table 11-16. Bolt and Nut Bonding or Grounding to Flat Surface11-78
Figure 11-20. Copper Jumper Connector to Tubular Structure11-79
Figure 11-21. Bonding Conduit to Structure11-79
Figure 11-22. Aluminum Jumper Connection to Tubular Structure11-79
11-190. Creepage Distance11-75
11-191. Fuel Systems11-80
11-192. Electric Shock Prevention Bonding11-80
11-193. Lightning Protection Bonding11-80
11-194. Lightning Protection for Antennas and Air Data Probes11-81
11-195. Static-Discharge Devices11-81
11-196. Cleaning11-81
11-197. Hardware Assembly11-81
11-198.11-204. [RESERVED.]11-81
SECTION 16. WIRE MARKING
11-205. General11-83
11-206. Wire Identification11-83
11-207. Identification and Information Related to the Wire and Wiring Diagrams11-83
11-208. Placement of Identification Markings11-83
Figure 11-23. Spacing of Printed Identification Marks (Direct Marking)11-84
Figure 11-24. Spacing of Printed Identification Marks (Indirect Marking)11-84
11-209. Types of Wire Markings11-83
11-210. Hot Stamp Marking11-84
Page xxix
CONTENTS (CONTINUED) Paragraph Page
11-211. Dot Matrix Marking11-85
11-212. Ink Jet Marking11-85
11-213. Laser Marking11-85
11-214. Identification Sleeves11-85
11-215. Identification Tape11-86
11-216. Operating Conditions11-86
11-217. Installation of Printed Sleeves11-86
Table 11-17. Recommended Size of Identification Sleeving11-86
11-218. Identification of Wire Bundles and Harnesses11-86
Figure 11-25. Identification of Wire Bundles and Harnesses11-87
11-219. Terminal Marking Sleeve and Tags11-87
Figure 11-26. Standard Sleeves (135 °C)11-87
Figure 11-27. Installation of Heat-Shrinkable Insulation Sleeves11-87
11-220. Sleeves and Cable Markers Selection11-87
Figure 11-28. Cable Markers11-88
Figure 11-29. Tie-Down Strap Installation11-88
Table 11-18. Selection Table for Standard Sleeves11-88
Table 11-19. Selection Table for Thin-Wall Sleeves11-89
Table 11-20. Selection Table for High-Temperature Sleeves11-89
Table 11-21. Selection Table for Cable Markers11-89
Table 11-22. Plastic Tie-Down Straps (MS3367, Type I, Class 1)11-89
Figure 11-30. Tie-Down Strap Installation Tool11-90
Figure 11-31. Completed Installation11-90
11-221. Temporary Wire and Cable Marking Procedure11-90
Figure 11-32. Temporary Wire Identification Marker11-90
11-222. Marker Sleeve Installation After Printing11-90
Figure 11-33. Inserting Wire Into Marker11-90a
Figure 11-34. Shrinking Marker on Wire11-90a
11-223.11-229. [RESERVED.]11-90a
SECTION 17. CONNECTORS
11-230. General11-91
11-231. Selection11-91
11-232. Types of Connectors11-91
Figure 11-35. Connector Information Example11-91b
Figure 11-36. Different Types of Connectors11-93
Figure 11-37. Coax Cable Connectors11-94
11-233. Voltage and Current Rating11-91a
11-234. Spare Contacts (Future Wiring)11-97
11-235. Installation11-97
11-236. Feed-Through Bulkhead Wire Protection11-98
11-237. Special Purpose Connector11-98
11-238. Potting Compounds11-98
11-239. Potting Connectors11-98
Figure 11-38. Spare Wires for Potting Connector11-99
11-240. Through Bolts11-99
11-241.11-247. [RESERVED.]11-99
Page xxx
CONTENTS (CONTINUED) Paragraph Page SECTION 18. CONDUITS
11-248. General11-101
11-249. Size of Conduit11-101
11-250. Conduit Fittings11-101
11-251. Conduit Installation11-101
11-252. Rigid Conduit11-101
Table 11-23. Bend Radii for Rigid Conduit11-101
11-253. Flexible Conduit11-102
Table 11-24. Minimum Bending Radii for Flexible Aluminum or Brass Conduit11-102
11-254.11-259. [RESERVED.]11-102
SECTION 19. PROTECTION OF UNUSED CONNECTORS
11-260. General11-103
11-261. Quick Reference Chart11-103
Table 11-25. Contact Cavity Sealing-Quick Reference11-104
11-262. Unpressurized Area Connectors11-103
Figure 11-39. Stub Wire Installation11-104
Table 11-26. Sealing Rod Dimensions11-104
11-263. Pressurized Areas11-103
Figure 11-40. Sealing Unused Contact Cavities-Unpressurized Areas-(Cut-Away View)11-104
11-264.11-270. [RESERVED.]11-104
SECTION 20. ELECTRICALAND ELECTRONIC SYMBOLS
11-271. General11-105
11-272. Symbols11-105
Table 11-27. Electronic/Electrical Symbols11-105
11-273.11-283. [RESERVED.]11-118
CHAPTER 12. AIRCRAFT AVIONICS SYSTEMS SECTION 1. A VIONICS EQUIPMENT MAINTENANCE
12-1. General12-1
12-2. Handling of Components12-1
12-3.12-7. [RESERVED.]12-1
SECTION 2. GROUND OPERATIONAL CHECKS FOR A VIONICS EQUIPMENT (ELECTRICAL)
12-8. General12-3
12-9. Inspection of Avionics System12-3
12-10. Communication Systems12-4
Page xxxi
CONTENTS (CONTINUED) Paragraph Page
12-11. VHF Omni-Directional Range (VOR)12-5
12-12. Distance Measuring Equipment (DME)12-5
12-13. Automatic Direction Finder (ADF)12-5
12-14. Instrument Landing Systems (ILS)12-6
12-15. Marker Beacon12-6
12-16. Long Range Navigation (LORAN)12-6
12-17. Global Positioning System (GPS)12-7
12-18. Autopilot Systems12-7
12-19. Altimeters12-7
12-20. Transponders12-8
12-21. Emergency Locator Transmitters (ELT)12-8
12-22. Inspection of ELT12-8
12-23. Flight Data Recorder12-9
12-24. Cockpit Voice Recorders (CVR)12-10
12-25. Weather Radar12-10
12-26. Radome Inspection12-11
12-27. Data Bus12-11
12-28. 12-36. [RESERVED.]12-11
SECTION 3. GROUND OPERATIONAL CHECKS FOR A VIONICS EQUIPMENT (NON ELECTRICAL)
12-37. Compass Check Swing12-13
12-38. Pneumatic Gyros12-15
Figure 12-1. Venturi System For Providing Airflow Through Gyro Instruments12-15
Figure 12-2. Instrument Vacuum System Using a Wet-Type Vacuum Pump12-17
Figure 12-3. Instrument Vacuum system Using a Dry-Type Air Pump12-18
Figure 12-4. Instrument Pressure System Using a Dry-Type Air Pump12-18
12-39.12-50. [RESERVED.]12-18
SECTION 4. PITOT/STATIC SYSTEM
12-51. General12-19
12-52. System Components12-19
Figure 12-5. Pitot/Static system for a small aircraft12-19
12-53. Pitot/Static Tubes and Lines12-19
12-54. Static Ports12-19
12-55. Heater Elements12-19
Figure 12-6. Pitot/Static Tube Head12-20
12-56. System Inspection12-19
12-57. System Leak Test12-20
12-58. Static System Test12-21
12-59. Test Pitot System12-21
12-60. Maintenance Precautions12-21
12-61. Replacing Lines12-22
12-62. Relocation of Pitot Tube12-22
12-63. Troubleshooting the Pitot/Static Pressure System12-22
Table 12-1. color codes for pitot-static systems12-23
12-64. 12-69. [RESERVED.]12-23
Page xxxii
CONTENTS (CONTINUED) Paragraph Page SECTION 5. AVIONICS TEST EQUIPMENT
12-70. General12-25
12-71. Test Equipment Calibration Standards12-25
12-72. Test Equipment Calibration12-25
12-73.12-83. [RESERVED.]12-25
CHAPTER 13. HUMAN FACTORS
13-1. Human Factors Influence on Mechanic's Performance13-1
13-2 The FAA Aviation Safety Program13-1
Figure 13-1. Personal Minimum's Checklist13-1
APPENDIX 1. GLOSSARY. (10 PAGES) APPENDIX 2. ACRONYMS AND ABBREVIATIONS (4 PAGES) APPENDIX 3.METRIC-BASED PREFIXES AND POWERS OF 10 (1 PAGE) Page xxxiii (and xxxiv)
CHAPTER 1. WOOD STRUCTURE
SECTION 1. MATERIALS AND PRACTICES
1-1. GENERAL. Wood aircraft construction dates back to the early days of certificated aircraft. Today only a limited number of wood aircraft structures are produced. However, many of the older airframes remain in service.
With proper care, airframes from the 1930’s through the 1950’s have held up remarkably well considering the state of technology and long term experience available at that time. It is the responsibility of the mechanic to carefully inspect such structures for deterioration and continuing airworthiness.
1-2. WOODS.
a. Quality of Wood. All wood and ply - wood used in the repair of aircraft structures should be of aircraft quality (reference Army Navy Commerce Department Bulletin ANC-19, Wood Aircraft Inspection and Fabrication). Table 1-1 lists some permissible variations in characteristics and properties of aircraft wood. However, selection and approval of woodstock for aircraft structural use are specialized skills and should be done by personnel who are thoroughly familiar with inspection criteria and methods.
b. Substitution of Original Wood. T h e wood species used to repair a part should be the same as that of the original whenever possible; however, some permissible substitutes are given in table 1-1. Obtain approval from the airframe manufacturer or the Federal Aviation Administration (FAA) for the re - placement of modified woods or other nonwood products with a substitute material.
c. Effects of Shrinkage. When the moisture content of a wooden part is lowered, the part shrinks. Since the shrinkage is not equal in all directions, the mechanic should consider the effect that the repair may have on the completed structure. The shrinkage is greatest in a tangential direction (across the fi - bers and parallel to the growth rings), somewhat less in a radial direction (across the fibers and perpendicular to the growth rings), and is negligible in a longitudinal direction (parallel to the fibers). Figure 1-1 illustrates the differ - ent grain directions and the effects of shrinkage on the shape of a part. These dimensional changes can have several detrimental effects upon a wood structure, such as loosening of FIGURE 1-1. Relative shrinkage of wood members due to drying.
Par 1-1 Page 1-1
TABLE 1-1. Selection and Properties of Aircraft Wood. (See notes following table.)
Species of Wood Strength properties as compared to spruce Maximum permissible grain deviation (slope of grain) Remarks
1. 2. 3. 4.
Spruce(Picea) Sitka (P.
Sitchensis) Red (P. Rubra) White (P. Glauca).
100% 1:15 Excellent for all uses. Considered as standard for this table.
Douglas Fir (Pseudotsuga Taxifolia).
Exceeds spruce. 1:15 May be used as substitute for spruce in same sizes or in slightly reduced sizes providing reductions are substantiated. Difficult to work with handtools.
Some tendency to split and splinter during fabrication and considerable more care in manufacture is necessary. Large solid pieces should be avoided due to inspection difficulties. Gluing satisfactory.
Noble Fir (Abies Nobiles).
Slightly exceeds spruce except 8% deficient in shear.
1:15 Satisfactory characteristics with respect to work - ability, warping, and splitting. May be used as direct substitute for spruce in same sizes providing shear does not become critical. Hardness somewhat less than spruce. Gluing satisfactory.
Western Hemlock (Tsuga Heterpphylla).
Slightly exceeds spruce. 1:15 Less uniform in texture than spruce. May be used as direct substitute for spruce. Upland growth superior to lowland growth. Gluing satisfactory.
Pine, Northern White (Pinus Strobus).
Properties between 85 % and 96 % those of spruce.
1:15 Excellent working qualities and uniform in properties, but somewhat low in hardness and shockresisting capacity. Cannot be used as substitute for spruce without increase in sizes to compensate for lesser strength. Gluing satisfactory.
White Cedar, Port Orford (Charaecyparis Lawsoniana).
Exceeds spruce. 1:15 May be used as substitute for spruce in same sizes or in slightly reduced sizes providing reductions are substantiated. Easy to work with handtools. Gluing difficult, but satisfactory joints can be obtained if suitable precautions are taken.
Poplar, Yellow (Liriodendrow Tulipifera).
Slightly less than spruce except in compression (crushing) and shear.
1:15 Excellent working qualities. Should not be used as a direct substitute for spruce without carefully ac - counting for slightly reduced strength properties.
Somewhat low in shock-resisting capacity. Gluing satisfactory.
Notes for Table 1-1
1. Defects Permitted.
a. Cross grain. Spiral grain, diagonal grain, or a combination of the two is acceptable providing the grain does not diverge from the longitudinal axis of the material more than specified in column 3. A check of all four faces of the board is necessary to determine the amount of divergence. The direction of free-flowing ink will frequently assist in determining grain direction.
b. Wavy, curly, and interlocked grain. Acceptable, if local irregularities do not exceed limitations specified for spiral and diagonal grain.
c. Hard knots. Sound, hard knots up to 3/8 inch in maximum diameter are acceptable providing: (1) they are not projecting portions of I-beams, along the edges of rectangular or beveled unrouted beams, or along the edges of flanges of box beams (except in lowly stressed portions); (2) they do not cause grain divergence at the edges of the board or in the flanges of a beam more than specified in column 3; and (3) they are in the center third of the beam and are not closer than 20 inches to another knot or other defect (pertains to 3/8 inch knots—smaller knots may be proportionately closer). Knots greater than 1/4 inch must be used with caution.
d. Pin knot clusters. Small clusters are acceptable providing they produce only a small effect on grain direction.
e. Pitch pockets. Acceptable in center portion of a beam providing they are at least 14 inches apart when they lie in the same growth ring and do not exceed 1-1/2 inches length by 1/8 inch width by 1/8 inch depth, and providing they are not along the projecting portions of I-beams, along the edges of rectangular or beveled unrouted beams, or along the edges of the flanges of box beams.
f. Mineral streaks. Acceptable, providing careful inspection fails to reveal any decay.
Page 1-2 Par 1-2
TABLE 1-1. Selection and Properties of Aircraft Wood. (See notes following table.) (continued)
2. Defects Not Permitted.
a. Cross grain. Not acceptable, unless within limitations noted in 1a.
b. Wavy, curly, and interlocked grain. Not acceptable, unless within limitations noted in 1b.
c. Hard knots. Not acceptable, unless within limitations noted in 1c.
d. Pin knot clusters. Not acceptable, if they produce large effect on grain direction.
e. Spike knots. These are knots running completely through the depth of a beam perpendicular to the annual rings and appear most frequently in quarter-sawed lumber. Reject wood containing this defect.
f. Pitch pockets. Not acceptable, unless within limitations noted in 1e.
g. Mineral streaks. Not acceptable, if accompanied by decay (see 1f).
h. Checks, shakes, and splits. Checks are longitudinal cracks extending, in general, across the annual rings.
Shakes are longitudinal cracks usually between two annual rings. Splits are longitudinal cracks induced by artificially induced stress. Reject wood containing these defects.
i. Compression wood. This defect is very detrimental to strength and is difficult to recognize readily. It is characterized by high specific gravity, has the appearance of an excessive growth of summer wood, and in most species shows little contrast in color between spring wood and summer wood. In doubtful cases reject the material, or subject samples to toughness machine test to establish the quality of the wood. Reject all material containing compression wood.
j. Compression failures. This defect is caused from the wood being overstressed in compression due to natural forces during the growth of the tree, felling trees on rough or irregular ground, or rough handling of logs or lumber.
Compression failures are characterized by a buckling of the fibers that appear as streaks on the surface of the piece substantially at right angles to the grain, and vary from pronounced failures to very fine hairlines that require close inspection to detect. Reject wood containing obvious failures. In doubtful cases reject the wood, or make a further inspection in the form of microscopic examination or toughness test, the latter means being the more reliable.
k. Decay. Examine all stains and discoloration carefully to determine whether or not they are harmless, or in a stage of preliminary or advanced decay. All pieces must be free from rot, dote, red heart, purple heart, and all other forms of decay.
fittings and wire bracing and checking or splitting of wood members. A few suggestions for minimizing these shrinkage effects are:
(1) Use bushings that are slightly short so that when the wood member shrinks the bushings do not protrude and the fittings may be tightened firmly against the member.
(2) Gradually drop off plywood faceplates by feathering as shown in figure 1-2.
(3) Thoroughly seal all wood surfaces, particularly end grain and bolt holes, with varnish, epoxy, or other acceptable sealer to slow or prevent moisture changes in the member.
(See Section 5. Finishing Wood Structures.)
1-3. MODIFIED WOOD PRODUCTS.
The most common forms of modified woods found in aircraft construction are plywood.
Although not a wood product, Phenolic parts are sometimes incorporated into structures.
These products are used whenever the manu- FIGURE 1-2. Tapering of faceplate.
facturer requires specialized strength or durability characteristics.
1-4. ADHESIVES. Because of the critical role played by adhesives in aircraft structure, the mechanic must employ only those types of adhesives that meet all of the performance requirements necessary for use in certificated civil aircraft. Use each product strictly in accordance with the aircraft and adhesive manufacturer’s instructions.
a. Adhesives acceptable to the FAA can be identified in the following ways:
Par 1-2 Page 1-3