SECTION 7. SAFETYING
7-122. GENERAL. The word safetying is a term universally used in the aircraft industry.
Briefly, safetying is defined as: “Securing by various means any nut, bolt, turnbuckle etc., on the aircraft so that vibration will not cause it to loosen during operation.” These practices are not a means of obtaining or maintaining torque, rather a safety device to prevent the disengagement of screws, nuts, bolts, snap rings, oil caps, drain cocks, valves, and parts.
Three basic methods are used in safetying;
safety-wire, cotter pins, and self-locking nuts.
Retainer washers and pal nuts are also some - times used.
a. Wire, either soft brass or steel is used on cylinder studs, control cable turnbuckles, and engine accessory attaching bolts.
b. Cotter pins are used on aircraft and engine controls, landing gear, and tailwheel assemblies, or any other point where a turning or actuating movement takes place.
c. Self-locking nuts are used in applications where they will not be removed often.
Repeated removal and installation will cause the self-locking nut to lose its locking feature.
They should be replaced when they are no longer capable of maintaining the minimum prevailing torque. (See table 7-2.)
d. Pal or speed nuts include designs which force the nut thread against the bolt or screw thread when tightened. These nuts should never be reused and should be replaced with new ones when removed.
7-123. SAFETY WIRE. Do not use stainless steel, monel, carbon steel, or aluminum alloy safety wire to secure emergency mechanisms such as switch handles, guards covering handles used on exits, fire extinguishers, emergency gear releases, or other emergency equipment. Some existing structural equipment or safety-of-flight emergency devices require copper or brass safety wire (.020 inch diameter only). Where successful emergency operation of this equipment is dependent on shearing or breaking of the safety wire, particular care should be used to ensure that safetying does not prevent emergency operation.
a. There are two methods of safety wiring; the double-twist method that is most commonly used, and the single-wire method used on screws, bolts, and/or nuts in a closelyspaced or closed-geometrical pattern such as a triangle, square, rectangle, or circle. The single-wire method may also be used on parts in electrical systems and in places that are diffi - cult to reach. (See figures 7-3 and 7-3a.)
b. When using double-twist method of safety wiring, .032 inch minimum diameter wire should be used on parts that have a hole diameter larger than .045 inch. Safety wire of .020 inch diameter (double strand) may be used on parts having a nominal hole diameter between .045 and .062 inch with a spacing between parts of less than 2 inches. When using the single-wire method, the largest size wire that the hole will accommodate should be used. Copper wire (.020 inch diameter), aluminum wire (.031 inch diameter), or other similar wire called for in specific technical or - ders, should be used as seals on equipment such as first-aid kits, portable fire extinguishers, emergency valves, or oxygen regulators.
CAUTION: Care should be taken not to confuse steel with aluminum wire.
c. A secure seal indicates that the com - ponent has not been opened. Some emergency devices require installation of brass or soft Par 7-122 Page 7-19
SMALL SCREWS IN CLOSELY SINGLE- FASTENER APPLICATION
SPACED CLOSED GEOMETRICAL DOUBLE-TWIST METHOD
PATTERN
SINGLE - WIRE METHOD
EXTERNAL SNAPRING
SINGLE-WIRE METHOD
SCREWHEADS
DOUBLE-TWIST METHOD
BOLTHEADS CASTLE NUTS NOTE THE SAFETYWIRE IS SHOWN INSTALLED FOR RIGHT-HAND THREADS. THE SAFETYWIRE
IS ROUTED IN THE OPPOSITE DIRECTION FOR LEFT-HAND THREADS FIGURE 7-3. Securing screws, nuts, bolts, and snaprings.
6 TO 8 copper shear safety wire. Particular care TWIST PER INCH should be exercised to ensure that the use of safety wire will not prevent emergency operation of the devices.
INCH 7-124. SAFETY-WIRING PROCEDURES.
There are many combinations of safety wiring with certain basic rules common to all applications. These rules are as follows.
a. When bolts, screws, or other parts are closely grouped, it is more convenient to safety wire them in series. The number of bolts, nuts, screws, etc., that may be wired together depends on the application.
FIGURE 7-3a. Wire twisting by hand. b. Drilled boltheads and screws need not be safety wired if installed with self-locking nuts.
Page 7-20 Par 7-123
c. To prevent failure due to rubbing or vibration, safety wire must be tight after installation.
d. Safety wire must be installed in a manner that will prevent the tendency of the part to loosen.
e. Safety wire must never be over - stressed. Safety wire will break under vibrations if twisted too tightly. Safety wire must be pulled taut when being twisted, and maintain a light tension when secured. (See fig - ure 7-3a.)
f. Safety-wire ends must be bent under and inward toward the part to avoid sharp or projecting ends, which might present a safety hazard.
g. Safety wire inside a duct or tube must not cross over or obstruct a flow passage when an alternate routing can be used.
(1) Check the units to be safety wired to make sure that they have been correctly torqued, and that the wiring holes are properly aligned to each other. When there are two or more units, it is desirable that the holes in the units be aligned to each other. Never overtorque or loosen to obtain proper alignment of the holes. It should be possible to align the wiring holes when the bolts are torqued within the specified limits. Washers may be used (see paragraph 7-37) to establish proper alignment.
However, if it is impossible to obtain a proper alignment of the holes without undertorquing or overtorquing, try another bolt which will permit proper alignment within the specified torque limits.
(2) To prevent mutilation of the twisted section of wire, when using pliers, grasp the wires at the ends. Safety wire must not be nicked, kinked, or mutilated. Never twist the wire ends off with pliers; and, when cutting off ends, leave at least four to six complete turns (1/2 to 5/8 inch long) after the loop. When removing safety wire, never twist the wire off with pliers. Cut the safety wire close to the hole, exercising caution.
h. Install safety wire where practicable with the wire positioned around the head of the bolt, screw, or nut, and twisted in such a manner that the loop of the wire fits closely to the contour of the unit being safety wired.
7-125. TWISTING WITH SPECIAL TOOLS. Twist the wire with a wire twister as follows. (See figure 7-4.)
CAUTION: When using wire twisters, and the wire extends 3 inches be - yond the jaws of the twisters, loosely wrap the wire around the pliers to prevent whipping and possible per - sonal injury. Excessive twisting of the wire will weaken the wire.
a. Grip the wire in the jaws of the wire twister and slide the outer sleeve down with your thumb to lock the handles or lock the spring-loaded pin.
b. Pull the knob, and the spiral rod spins and twists the wire.
c. Squeeze handles together to release wire.
7-126. SECURING OIL CAPS, DRAIN COCKS, AND VALVES. (See figure 7-4a.)
When securing oil caps and drain cocks, the safety wire should be anchored to an adjacent fillister-head screw. This method of safety wiring is applied to wingnuts, filler plugs, single-drilled head bolts, fillister-head screws, etc.; which are safety wired individually.
When securing valve handles in the vertical position, the wire is looped around the threads of the pipe leading into one side of the valve, Par 7-124 Page 7-21
FIGURE 7-4. Use of a typical wire twister.
double-twisted around the valve handle, and anchored around the threads of the pipe leading into the opposite side of the valve. When castellated nuts are to be secured with safety wire, tighten the nut to the low side of the se - lected torque range, unless otherwise specified;
and, if necessary, continue tightening until a slot lines with the hole. In blind tapped hole applications of bolts or castellated nuts on studs, the safety wiring should be in accordance with the general instructions of this chapter. Hollow-head bolts are safetied in the manner prescribed for regular bolts.
NOTE: Do not loosen or tighten properly tightened nuts to align safety-wire holes.
NOTE: Although there are numerous safety wiring techniques used to se - cure aircraft hardware, practically all are derived from the basic examples shown in figures 7-5 through 7-5b.
FIGURE 7-4a. Securing oil caps, drain cocks, and valves.
Page 7-22 Par 7-126
Examples 1, 2, 3, and 4 apply to all types of bolts, fillister-head screws, square-head plugs, and other similar parts which are wired so that the loosening tendency of either part is counteracted by tightening of the other part. The direction of twist from the second to the third unit is counterclockwise in exam - ples 1, 3, and 4 to keep the loop in position against the head of the bolt. The direction of twist from the second to the third unit in example 2 is clockwise to keep the wire in position around the second unit.
The wire entering the hole in the third unit will be the lower wire, except example 2, and by making a counterclockwise twist after it leaves the hole, the loop will be secured in place around the head of that bolt.
Examples 5, 6, 7, & 8 show methods for wiring various standard items, NOTE: Wire may be wrapped over the unit rather than around it when wiring castellated nuts or on other items when there is a clear - ance problem.
Example 9 shows the method for wiring bolts in different planes. Note that wire should always be applied so that tension is in the tightening direction.
Hollow-head plugs shall be wired as shown with the tab bent inside the hole to avoid snags and possible injury to personnel working on the engine.
Correct application of single wire to closely spaced multiple group.
FIGURE 7-5. Safety-wiring procedures.
Par 7-126 Page 7-23
Examples 12 and 13 show methods for attaching lead seal to protect critical adjustments.
Example 14 shows bolt Example 15 shows correct Example 16 shows correct wired to a right-angle method for wiring adjustable method for wiring the coubracket with the wire connecting rod. pling nut on flexible line to wrapped around the the straight connector bracket. brazed on rigid tube.
Fittings incorporating wire lugs shall be wired as shown in Exam- Small size coupling nuts ples 17 and 18. Where no lock-wire lug is provided, wire should shall be wired by wrapping be applied as shown in examples 19 and 20 with caution being the wire around the nut exerted to ensure that wire is wrapped tightly around the fitting. and inserting it through the holes as shown.
FIGURE 7-5a. Safety-wiring procedures.
Page 7-24 Par 7-126
Coupling nuts attached to straight connectors shall be wired as, shown, when hex is an integral part of the connector.
Coupling nuts on a tee shall be wired, as shown above, so that tension is always in the tightening direction.
Straight Connector (Bulkhead Type) Examples 26, 27, and 28 show the proper method for wiring various standard fittings with checknut wired independently so that it need not be disturbed when removing the coupling nut.
FIGURE 7-5b. Safety-wiring procedures.
Par 7-126 Page 7-25
7-127. SECURING WITH COTTER PINS.
a. Cotter pins are used to secure such items as bolts, screws, pins, and shafts. Their use is favored because they can be removed and installed quickly. The diameter of the cotter pins selected for any application should be the largest size that will fit consistent with the diameter of the cotter pin hole and/or the slots in the nut. Cotter pins should not be reused on aircraft.
b. To prevent injury during and after pin installation, the end of the cotter pin can be rolled and tucked.
NOTE: In using the method of cotter pin safetying, as shown in figures 7-6 and 7-7, ensure the prong, bent over the bolt, is seated firmly against the bolt shank, and does not exceed bolt diameter. Also, when the prong is bent over the nut, ensure the bent prong is down and firmly flat against the nut and does not contact the sur - face of the washer.
FIGURE 7-6. Securing with cotter pins.
FIGURE 7-7. Alternate method for securing with cotter pins.
7-128. 7-139. [RESERVED.] Page 7-26 Par 7-127
SECTION 8. INSPECTION AND REPAIR OF CONTROL CABLES
AND TURNBUCKLES
7-140. GENERAL. Aircraft control cables are generally fabricated from carbon steel or corrosion-resistant steel wire of either flexible or nonflexible-type construction.
7-141. CABLE DEFINITIONS. T h e f o l lowing cable components are defined in accor dance with Military Specifications MIL-W-83420, MIL-C-18375, and MIL-W-87161.
a. Wire Center. The center of all strands shall be an individual wire and shall be desig nated as a wire center.
b. Strand Center or Core. A strand cen ter is a single, straight strand made of pre formed wires, similar to the other strands comprising the cable, in arrangement and number of wires.
c. Independent Wire Rope Center (IWRC) 7 by 7. A 7 by 7 independent wire rope center as specified herein shall consist of a cable or wire rope of six strands of seven wires each, twisted or laid around a strand center or core consisting of seven wires.
7-142. FLEXIBLE CABLES. Flexible, preformed, carbon steel, Type I, composition A cables, MIL-W-83420, are manufactured from steel made by the acid-open-hearth, basic-open hearth, or electric-furnace process. The wire used is coated with pure tin or zinc. Flexible, preformed, corrosion-resistant, Type I, compo sition B cables, MIL-W-87161, MIL-W-83420, and MIL-C-18375 are manu factured from steel made by the electricfurnace process. (See table 7-3 and fig ure 7-8.) These cables are of the 3 by 7, 7 by 7, 7 by 19, or 6 by 19 IWRC construction, according to the diameter as specified in ta ble 7-3. The 3 by 7 cable consists of three strands of seven wires each. There is no core in this construction. The 3 by 7 cable has a length of lay of not more than eight times or less than five times the nominal cable diame ter. The 7 by 7 cable consists of six strands, of seven wires each, laid around a center strand of seven wires. The wires are laid so as to de velop a cable which has the greatest bending and wearing properties. The 7 by 7 cable has a length of lay of not more than eight times or less than six times the cable diameter. The 7 by 19 cable consists of six strands laid around a center strand in a clockwise direction.
The wires composing the seven individual strands are laid around a center wire in two layers. The center core strand consists of a lay of six wires laid around the central wire in a clockwise direction and a layer of 12 wires laid around this in a clockwise direction. The six outer strands of the cable consist of a layer of six wires laid around the center wire in a counterclockwise direction and a layer of 12 wires laid around this in a counterclockwise direction. The 6 by 19 cable consists of six strands of 19 wires each, laid around a 7 by 7.
MIL-C-18375 cable, although not as strong as MIL-W-83420, is equal in corrosion resistance and superior in non-magnetic and coefficient of thermal expansion properties.
7-143. NYLON-COATED CABLES.
a. Nylon-coated cable is made by ex truding a flexible nylon coating over corro sion-resistant steel (CRES) cable. The bare CRES cable must conform and be qualified to MIL-W-83420. After coating, the jacketed ca ble must still conform to MIL-W-83420.
b. The service life of nylon-coated cable is much greater than the service life of the same cable when used bare. Most cable wear occurs at pulleys where the cable bends. Wear Par 7-140 Page 7-27
TABLE 7-3. Flexible cable construction and physical properties.
MINIMUM BREAKING STRENGTH (Pounds)
NOMINAL
DIAMETER
OF WIRE ROPE CABLE
CONSTRUCTION
TOLERANCE ON
DIAMETER (PLUS ONLY)
ALLOWABLE
INCREASE OF
DIAMETER AT
CUT END MIL-W- 83420 COMP A MIL-W- 83420 COMP B (CRES) MIL-C- 18375 (CRES)
INCHES INCHES INCHES LBS LBS LBS 1/32 3 x 7 0.006 0.006 110 110 3/64 7 x 7 0.008 0.008 270 270 1/16 7 x 7 0.010 0.009 480 480 360 1/16 7 x 19 0.010 0.009 480 480 3/32 7 x 7 0.012 0.010 920 920 700 3/32 7 x 19 0.012 0.010 1,000 920 1/8 7 x 19 0.014 0.011 2,000 1,760 1,300 5/32 7 x 19 0.016 0.017 2,800 2,400 2,000 3/16 7 x 19 0.018 0.019 4,200 3,700 2,900 7/32 7 x 19 0.018 0.020 5,600 5,000 3,800 1/4 7 x 19 0.018 0.021 7,000 6,400 4,900 9/32 7 x 19 0.020 0.023 8,000 7,800 6,100 5/16 7 x 19 0.022 0.024 9,800 9,000 7,600 11/32 7 x 19 0.024 0.025 12,500 3/8 7 x 19 0.026 0.027 14,400 12,000 11,000 7/16 6 x 19 IWRC 0.030 0.030 17,600 16,300 14,900 1/2 6 x 19 IWRC 0.033 0.033 22,800 22,800 19,300 9/16 6 x 19 IWRC 0.036 0.036 28,500 28,500 24,300 5/8 6 x 19 IWRC 0.039 0.039 35,000 35,000 30,100 3/4 6 x 19 IWRC 0.045 0.045 49,600 49,600 42,900 7/8 6 x 19 IWRC 0.048 0.048 66,500 66,500 58,000 1 6 x 19 IWRC 0.050 0.050 85,400 85,400 75,200 1 - 1/8 6 x 19 IWRC 0.054 0.054 106,400 106,400 1 - 1/4 6 x 19 IWRC 0.057 0.057 129,400 129,400 1 - 3/8 6 x 19 IWRC 0.060 0.060 153,600 153,600 1 - 1/2 6 x 19 IWRC 0.062 0.062 180,500 180,500 is caused by friction between strands and be tween wires. In bare cable, this is aggravated by dirt and grit working its way into the cable;
and the lubricant working its way out leaving dry, dirty wires rubbing against each other. In long, straight runs of cable, vibration workhardens the wires causing the brittle wires to fracture with eventual failure of the cable.
c. The nylon-jacket protects the cable in a threefold manner. It keeps the lubricant from oozing out and evaporating, it keeps dirt and grit out, and it dampens the vibrations, thereby, greatly reducing their effect on the ca ble.
7-144. NONFLEXIBLE CABLES. (Refer to table 7-4 and figure 7-9.) Nonflexible, pre formed, carbon steel cables, MIL-W-87161, composition A, are manufactured by the same processes as MIL-W-83420, composition B, flexible corrosion-resistant steel cables. The nonflexible steel cables are of the 1 by 7 (Type I) or 1 by 19 (Type II) construction ac cording to the diameter as specified in ta ble 7-4. The 1 by 7 cable consists of six Page 7-28 Par 7-143
FIGURE 7-8. Flexible cable cross section.
TABLE 7-4. Nonflexible cable construction and physical properties.
STRAND TYPE
NOMINAL
DIAMETER OF WIRE STRAND In.
TOLERANCE ON
DIAMETER (Plus Only) In.
ALLOWABLE
INCREASE IN
DIAMETER
AT THE END In.
CONSTRUCTION MIL-W-87161
MINIMUM BREAK
STRENGTH
COMP A & B Lbs.
I 1/32 0.003 0.006 1 x 7 185 I 3/64 0.005 0.008 1 x 7 375 II 3/64 0.005 0.008 1 x 19 375 I 1/16 0.006 0.009 1 x 7 500 II 1/16 0.006 0.009 1 x 19 500 II 5/64 0.008 0.009 1 x 19 800 II 3/32 0.009 0.010 1 x 19 1,200 II 7/64 0.009 0.010 1 x 19 1,600 II 1/8 0.013 0.011 1 x 19 2,100 II 5/32 0.013 0.016 1 x 19 3,300 II 3/16 0.013 0.019 1 x 19 4,700 II 7/32 0.015 0.020 1 x 19 6,300 II 1/4 0.018 0.021 1 x 19 8,200 II 5/16 0.022 0.024 1 x 19 12,500 II 3/8 0.026 0.027 1 x 19 17,500 FIGURE 7-9. Nonflexible cable cross section.
wires laid around a center wire in a counter clockwise direction. The 1 by 19 cable con sists of a layer of six wires laid around a center wire in a clockwise direction plus twelve wires laid around the inner strand in a counterclock wise direction.
7-145. CABLE SPECIFICATIONS. Cable diameter and strength data are given in ta ble 7-3 and table 7-4. These values are accept able for repair and modification of civil air craft.
7-146. CABLE PROOF LOADS. Cable terminals and splices should be tested for proper strength before installation. Gradually apply a test load equal to 60 percent of the ca ble-breaking strengths given in table 7-3 and Par 7-144 Page 7-29
table 7-4, for a period of 3 minutes. Place a suitable guard over the cable during the test to prevent injury to personnel in the event of ca ble failure.
7-147. REPLACEMENT OF CABLES.
Replace control cables when they become worn, distorted, corroded, or otherwise dam aged. If spare cables are not available, prepare exact duplicates of the damaged cable. Use materials of the same size and quality as the original. Standard swaged cable terminals de velop the full cable strength and may be sub stituted for the original terminals wherever practical. However, if facilities and supplies are limited and immediate corrective action is necessary, repairs may be made by using cable bushings, eye splices, and the proper combina tion of turnbuckles in place of the original in stallation. (See figure 7-12(c).)
a. Location of Splices. Locate splices so that no portion of the splice comes closer than 2 inches to any fair-lead or pulley. Locate connections at points where jamming cannot occur during any portion of the travel of either the loaded cable or the slack cable in the de flected position.
b. Cutting and Heating. Cut cables to length by mechanical means. The use of a torch, in any manner, is not permitted. Do not subject wires and cables to excessive tem perature. Soldering the bonding braid to the control cable is not permitted.
c. Ball-and-Socket Type Terminals. Do not use ball-and-socket type terminals or other types for general replacement that do not posi tively prevent cable untwisting, except where they were utilized on the original installation by the aircraft manufacturer.
d. Substitution of Cable. Substitution of cable for hard or streamlined wires will not be acceptable unless specifically approved by a representative of the FAA.
7-148. MECHANICALLY-FABRI- CATED CABLE ASSEMBLIES.
a. Swage-Type Terminals. Swage-type terminals, manufactured in accordance with AN, are suitable for use in civil aircraft up to, and including, maximum cable loads. When swaging tools are used, it is important that all the manufacturers’ instructions, including “go and no-go” dimensions, be followed in detail to avoid defective and inferior swaging. Ob servance of all instructions should result in a terminal developing the full-rated strength of the cable. Critical dimensions, both before and after swaging, are shown in table 7-5.
(1) Terminals. When swaging terminals onto cable ends, observe the following proce dures.
(a) Cut the cable to the proper length allowing for growth during swaging. Apply a preservative compound to the cable ends be fore insertion into the terminal barrel.
NOTE: Never solder cable ends to prevent fraying, since the presence of the solder will greatly increase the tendency of the cable to pull out of the terminal.
(b) Insert the cable into the terminal approximately 1 inch, and bend toward the terminal, then push the cable end entirely into the terminal barrel. The bending action puts a kink or bend in the cable end, and provides enough friction to hold the terminal in place until the swaging operation can be performed.
Bending also tends to separate the strands in side the barrel, thereby reducing the strain on them.
Page 7-30 Par 7-146