Examples 1, 2, 3, and 4 apply to all types of bolts, fillister-head screws, square-head plugs, and other similar parts which are wired so that the loosening tendency of either part is counteracted by tightening of the other part. The direction of twist from the second to the third unit is counterclockwise in exam - ples 1, 3, and 4 to keep the loop in position against the head of the bolt. The direction of twist from the second to the third unit in example 2 is clockwise to keep the wire in position around the second unit.

The wire entering the hole in the third unit will be the lower wire, except example 2, and by making a counterclockwise twist after it leaves the hole, the loop will be secured in place around the head of that bolt.

Examples 5, 6, 7, & 8 show methods for wiring various standard items, NOTE: Wire may be wrapped over the unit rather than around it when wiring castellated nuts or on other items when there is a clear - ance problem.

Example 9 shows the method for wiring bolts in different planes. Note that wire should always be applied so that tension is in the tightening direction.

Hollow-head plugs shall be wired as shown with the tab bent inside the hole to avoid snags and possible injury to personnel working on the engine.

Correct application of single wire to closely spaced multiple group.

FIGURE 7-5. Safety-wiring procedures.

Par 7-126 Page 7-23

Page 333Open in PDF

Examples 12 and 13 show methods for attaching lead seal to protect critical adjustments.

Example 14 shows bolt Example 15 shows correct Example 16 shows correct wired to a right-angle method for wiring adjustable method for wiring the coubracket with the wire connecting rod. pling nut on flexible line to wrapped around the the straight connector bracket. brazed on rigid tube.

Fittings incorporating wire lugs shall be wired as shown in Exam- Small size coupling nuts ples 17 and 18. Where no lock-wire lug is provided, wire should shall be wired by wrapping be applied as shown in examples 19 and 20 with caution being the wire around the nut exerted to ensure that wire is wrapped tightly around the fitting. and inserting it through the holes as shown.

FIGURE 7-5a. Safety-wiring procedures.

Page 7-24 Par 7-126

Page 334Open in PDF

Coupling nuts attached to straight connectors shall be wired as, shown, when hex is an integral part of the connector.

Coupling nuts on a tee shall be wired, as shown above, so that tension is always in the tightening direction.

Straight Connector (Bulkhead Type) Examples 26, 27, and 28 show the proper method for wiring various standard fittings with checknut wired independently so that it need not be disturbed when removing the coupling nut.

FIGURE 7-5b. Safety-wiring procedures.

Par 7-126 Page 7-25

Page 335Open in PDF

7-127. SECURING WITH COTTER PINS.

a. Cotter pins are used to secure such items as bolts, screws, pins, and shafts. Their use is favored because they can be removed and installed quickly. The diameter of the cotter pins selected for any application should be the largest size that will fit consistent with the diameter of the cotter pin hole and/or the slots in the nut. Cotter pins should not be reused on aircraft.

b. To prevent injury during and after pin installation, the end of the cotter pin can be rolled and tucked.

NOTE: In using the method of cotter pin safetying, as shown in figures 7-6 and 7-7, ensure the prong, bent over the bolt, is seated firmly against the bolt shank, and does not exceed bolt diameter. Also, when the prong is bent over the nut, ensure the bent prong is down and firmly flat against the nut and does not contact the sur - face of the washer.

FIGURE 7-6. Securing with cotter pins.

FIGURE 7-7. Alternate method for securing with cotter pins.

7-128.  7-139. [RESERVED.] Page 7-26 Par 7-127

Page 336Open in PDF

SECTION 8. INSPECTION AND REPAIR OF CONTROL CABLES

AND TURNBUCKLES

7-140. GENERAL. Aircraft control cables are generally fabricated from carbon steel or corrosion-resistant steel wire of either flexible or nonflexible-type construction.

7-141. CABLE DEFINITIONS. T h e f o l ­ lowing cable components are defined in accor­ dance with Military Specifications MIL-W-83420, MIL-C-18375, and MIL-W-87161.

a. Wire Center. The center of all strands shall be an individual wire and shall be desig­ nated as a wire center.

b. Strand Center or Core. A strand cen­ ter is a single, straight strand made of pre­ formed wires, similar to the other strands comprising the cable, in arrangement and number of wires.

c. Independent Wire Rope Center (IWRC) 7 by 7. A 7 by 7 independent wire rope center as specified herein shall consist of a cable or wire rope of six strands of seven wires each, twisted or laid around a strand center or core consisting of seven wires.

7-142. FLEXIBLE CABLES. Flexible, preformed, carbon steel, Type I, composition A cables, MIL-W-83420, are manufactured from steel made by the acid-open-hearth, basic-open hearth, or electric-furnace process. The wire used is coated with pure tin or zinc. Flexible, preformed, corrosion-resistant, Type I, compo­ sition B cables, MIL-W-87161, MIL-W-83420, and MIL-C-18375 are manu­ factured from steel made by the electricfurnace process. (See table 7-3 and fig­ ure 7-8.) These cables are of the 3 by 7, 7 by 7, 7 by 19, or 6 by 19 IWRC construction, according to the diameter as specified in ta­ ble 7-3. The 3 by 7 cable consists of three strands of seven wires each. There is no core in this construction. The 3 by 7 cable has a length of lay of not more than eight times or less than five times the nominal cable diame­ ter. The 7 by 7 cable consists of six strands, of seven wires each, laid around a center strand of seven wires. The wires are laid so as to de­ velop a cable which has the greatest bending and wearing properties. The 7 by 7 cable has a length of lay of not more than eight times or less than six times the cable diameter. The 7 by 19 cable consists of six strands laid around a center strand in a clockwise direction.

The wires composing the seven individual strands are laid around a center wire in two layers. The center core strand consists of a lay of six wires laid around the central wire in a clockwise direction and a layer of 12 wires laid around this in a clockwise direction. The six outer strands of the cable consist of a layer of six wires laid around the center wire in a counterclockwise direction and a layer of 12 wires laid around this in a counterclockwise direction. The 6 by 19 cable consists of six strands of 19 wires each, laid around a 7 by 7.

MIL-C-18375 cable, although not as strong as MIL-W-83420, is equal in corrosion resistance and superior in non-magnetic and coefficient of thermal expansion properties.

7-143. NYLON-COATED CABLES.

a. Nylon-coated cable is made by ex­ truding a flexible nylon coating over corro­ sion-resistant steel (CRES) cable. The bare CRES cable must conform and be qualified to MIL-W-83420. After coating, the jacketed ca­ ble must still conform to MIL-W-83420.

b. The service life of nylon-coated cable is much greater than the service life of the same cable when used bare. Most cable wear occurs at pulleys where the cable bends. Wear Par 7-140 Page 7-27

Page 337Open in PDF

TABLE 7-3. Flexible cable construction and physical properties.

MINIMUM BREAKING STRENGTH (Pounds)

NOMINAL

DIAMETER

OF WIRE ROPE CABLE

CONSTRUCTION

TOLERANCE ON

DIAMETER (PLUS ONLY)

ALLOWABLE

INCREASE OF

DIAMETER AT

CUT END MIL-W- 83420 COMP A MIL-W- 83420 COMP B (CRES) MIL-C- 18375 (CRES)

INCHES INCHES INCHES LBS LBS LBS 1/32 3 x 7 0.006 0.006 110 110 3/64 7 x 7 0.008 0.008 270 270 1/16 7 x 7 0.010 0.009 480 480 360 1/16 7 x 19 0.010 0.009 480 480 3/32 7 x 7 0.012 0.010 920 920 700 3/32 7 x 19 0.012 0.010 1,000 920 1/8 7 x 19 0.014 0.011 2,000 1,760 1,300 5/32 7 x 19 0.016 0.017 2,800 2,400 2,000 3/16 7 x 19 0.018 0.019 4,200 3,700 2,900 7/32 7 x 19 0.018 0.020 5,600 5,000 3,800 1/4 7 x 19 0.018 0.021 7,000 6,400 4,900 9/32 7 x 19 0.020 0.023 8,000 7,800 6,100 5/16 7 x 19 0.022 0.024 9,800 9,000 7,600 11/32 7 x 19 0.024 0.025 12,500 3/8 7 x 19 0.026 0.027 14,400 12,000 11,000 7/16 6 x 19 IWRC 0.030 0.030 17,600 16,300 14,900 1/2 6 x 19 IWRC 0.033 0.033 22,800 22,800 19,300 9/16 6 x 19 IWRC 0.036 0.036 28,500 28,500 24,300 5/8 6 x 19 IWRC 0.039 0.039 35,000 35,000 30,100 3/4 6 x 19 IWRC 0.045 0.045 49,600 49,600 42,900 7/8 6 x 19 IWRC 0.048 0.048 66,500 66,500 58,000 1 6 x 19 IWRC 0.050 0.050 85,400 85,400 75,200 1 - 1/8 6 x 19 IWRC 0.054 0.054 106,400 106,400 1 - 1/4 6 x 19 IWRC 0.057 0.057 129,400 129,400 1 - 3/8 6 x 19 IWRC 0.060 0.060 153,600 153,600 1 - 1/2 6 x 19 IWRC 0.062 0.062 180,500 180,500 is caused by friction between strands and be­ tween wires. In bare cable, this is aggravated by dirt and grit working its way into the cable;

and the lubricant working its way out leaving dry, dirty wires rubbing against each other. In long, straight runs of cable, vibration workhardens the wires causing the brittle wires to fracture with eventual failure of the cable.

c. The nylon-jacket protects the cable in a threefold manner. It keeps the lubricant from oozing out and evaporating, it keeps dirt and grit out, and it dampens the vibrations, thereby, greatly reducing their effect on the ca­ ble.

7-144. NONFLEXIBLE CABLES. (Refer to table 7-4 and figure 7-9.) Nonflexible, pre­ formed, carbon steel cables, MIL-W-87161, composition A, are manufactured by the same processes as MIL-W-83420, composition B, flexible corrosion-resistant steel cables. The nonflexible steel cables are of the 1 by 7 (Type I) or 1 by 19 (Type II) construction ac­ cording to the diameter as specified in ta­ ble 7-4. The 1 by 7 cable consists of six Page 7-28 Par 7-143

Page 338Open in PDF

FIGURE 7-8. Flexible cable cross section.

TABLE 7-4. Nonflexible cable construction and physical properties.

STRAND TYPE

NOMINAL

DIAMETER OF WIRE STRAND In.

TOLERANCE ON

DIAMETER (Plus Only) In.

ALLOWABLE

INCREASE IN

DIAMETER

AT THE END In.

CONSTRUCTION MIL-W-87161

MINIMUM BREAK

STRENGTH

COMP A & B Lbs.

I 1/32 0.003 0.006 1 x 7 185 I 3/64 0.005 0.008 1 x 7 375 II 3/64 0.005 0.008 1 x 19 375 I 1/16 0.006 0.009 1 x 7 500 II 1/16 0.006 0.009 1 x 19 500 II 5/64 0.008 0.009 1 x 19 800 II 3/32 0.009 0.010 1 x 19 1,200 II 7/64 0.009 0.010 1 x 19 1,600 II 1/8 0.013 0.011 1 x 19 2,100 II 5/32 0.013 0.016 1 x 19 3,300 II 3/16 0.013 0.019 1 x 19 4,700 II 7/32 0.015 0.020 1 x 19 6,300 II 1/4 0.018 0.021 1 x 19 8,200 II 5/16 0.022 0.024 1 x 19 12,500 II 3/8 0.026 0.027 1 x 19 17,500 FIGURE 7-9. Nonflexible cable cross section.

wires laid around a center wire in a counter­ clockwise direction. The 1 by 19 cable con­ sists of a layer of six wires laid around a center wire in a clockwise direction plus twelve wires laid around the inner strand in a counterclock­ wise direction.

7-145. CABLE SPECIFICATIONS. Cable diameter and strength data are given in ta­ ble 7-3 and table 7-4. These values are accept­ able for repair and modification of civil air­ craft.

7-146. CABLE PROOF LOADS. Cable terminals and splices should be tested for proper strength before installation. Gradually apply a test load equal to 60 percent of the ca­ ble-breaking strengths given in table 7-3 and Par 7-144 Page 7-29

Page 339Open in PDF

table 7-4, for a period of 3 minutes. Place a suitable guard over the cable during the test to prevent injury to personnel in the event of ca­ ble failure.

7-147. REPLACEMENT OF CABLES.

Replace control cables when they become worn, distorted, corroded, or otherwise dam­ aged. If spare cables are not available, prepare exact duplicates of the damaged cable. Use materials of the same size and quality as the original. Standard swaged cable terminals de­ velop the full cable strength and may be sub­ stituted for the original terminals wherever practical. However, if facilities and supplies are limited and immediate corrective action is necessary, repairs may be made by using cable bushings, eye splices, and the proper combina­ tion of turnbuckles in place of the original in­ stallation. (See figure 7-12(c).)

a. Location of Splices. Locate splices so that no portion of the splice comes closer than 2 inches to any fair-lead or pulley. Locate connections at points where jamming cannot occur during any portion of the travel of either the loaded cable or the slack cable in the de­ flected position.

b. Cutting and Heating. Cut cables to length by mechanical means. The use of a torch, in any manner, is not permitted. Do not subject wires and cables to excessive tem­ perature. Soldering the bonding braid to the control cable is not permitted.

c. Ball-and-Socket Type Terminals. Do not use ball-and-socket type terminals or other types for general replacement that do not posi­ tively prevent cable untwisting, except where they were utilized on the original installation by the aircraft manufacturer.

d. Substitution of Cable. Substitution of cable for hard or streamlined wires will not be acceptable unless specifically approved by a representative of the FAA.

7-148. MECHANICALLY-FABRI- CATED CABLE ASSEMBLIES.

a. Swage-Type Terminals. Swage-type terminals, manufactured in accordance with AN, are suitable for use in civil aircraft up to, and including, maximum cable loads. When swaging tools are used, it is important that all the manufacturers’ instructions, including “go and no-go” dimensions, be followed in detail to avoid defective and inferior swaging. Ob­ servance of all instructions should result in a terminal developing the full-rated strength of the cable. Critical dimensions, both before and after swaging, are shown in table 7-5.

(1) Terminals. When swaging terminals onto cable ends, observe the following proce­ dures.

(a) Cut the cable to the proper length allowing for growth during swaging. Apply a preservative compound to the cable ends be­ fore insertion into the terminal barrel.

NOTE: Never solder cable ends to prevent fraying, since the presence of the solder will greatly increase the tendency of the cable to pull out of the terminal.

(b) Insert the cable into the terminal approximately 1 inch, and bend toward the terminal, then push the cable end entirely into the terminal barrel. The bending action puts a kink or bend in the cable end, and provides enough friction to hold the terminal in place until the swaging operation can be performed.

Bending also tends to separate the strands in­ side the barrel, thereby reducing the strain on them.

Page 7-30 Par 7-146

Page 340Open in PDF

TABLE 7-5. Straight-shank terminal dimensions. (Cross reference AN to MS: AN-666 to MS 21259, AN-667 to MS 20667, AN-668 to MS 20668, AN-669 to MS 21260.)

Before swaging After swaging Cable size (inches) Wire strands Outside diameter Bore diameter Bore length Swaging length Minimum breaking strength (pounds) Shank diameter * 1/16 7 x 7 0.160 0.078 1.042 0.969 480 0.138 3/32 7 x 7 .218 .109 1.261 1.188 920 .190 1/8 7 x 19 .250 .141 1.511 1.438 2,000 .219 5/32 7 x 19 .297 .172 1.761 1.688 2,800 .250 3/16 7 x 19 .359 .203 2.011 1.938 4,200 .313 7/32 7 x 19 .427 .234 2.261 2.188 5,600 .375 1/4 7 x 19 .494 .265 2.511 2.438 7,000 .438 9/32 7 x 19 .563 .297 2.761 2.688 8,000 .500 5/16 7 x 19 .635 .328 3.011 2.938 9,800 .563 3/8 7 x 19 .703 .390 3.510 3.438 14,400 .625 *Use gauges in kit for checking diameters.

NOTE: If the terminal is drilled com - pletely through, push the cable into the terminal until it reaches the approximate position shown in figure 7-10. If the hole is not drilled through, insert the cable until the end rests against the bottom of the hole.

FIGURE 7-10. Insertion of cable into terminal.

(c) Accomplish the swaging opera­ tion in accordance with the instructions fur­ nished by the manufacturer of the swaging equipment.

(d) Inspect the terminal after swaging to determine that it is free from the die marks and splits, and is not out-of-round. Check for cable slippage in the terminal and for cut or broken wire strands.

(e) Using a “go no-go” gauge or a micrometer, check the terminal shank diameter as shown in figure 7-11 and table 7-5.

FIGURE 7-11. Gauging terminal shank after swaging.

(f) Test the cable by proof-loading it to 60 percent of its rated breaking strength.

(2) Splicing. Completely severed ca­ bles, or those badly damaged in a localized area, may be repaired by the use of an eye Par 7-148 Page 7-31

Page 341Open in PDF

terminal bolted to a clevis terminal. (See fig­ ure 7-12(a).) However, this type of splice can only be used in free lengths of cable which do not pass over pulleys or through fair-leads.

FIGURE 7-12. Typical cable splices.

(3) Swaged ball terminals. On some aircraft cables, swaged ball terminals are used for attaching cables to quadrants and special connections where space is limited. Single shank terminals are generally used at the cable ends, and double shank fittings may be used at either the end or in the center of the cable.

Dies are supplied with the swaging machines for attaching these terminals to cables by the following method.

(a) The steel balls and shanks have a hole through the center, and are slipped over the cable and positioned in the desired loca­ tion.

(b) Perform the swaging operation in accordance with the instructions furnished by the manufacturer of the swaging equipment.

(c) Check the swaged fitting with a “go no-go” gauge to see that the fitting is properly compressed, and inspect the physical condition of the finished terminal. (See fig­ ure 7-13.)

FIGURE 7-13. Typical terminal gauge.

(4) Cable slippage in terminal. Ensure that the cable is properly inserted in the termi­ nal after the swaging operation is completed.

Instances have been noted wherein only 1/4 inch of the cable was swaged in the termi­ nal. Observance of the following precautions should minimize this possibility.

(a) Measure the length of the termi­ nal end of the fitting to determine the proper length of cable to be inserted into the barrel of the fitting.

(b) Lay off this length at the end of the cable and mark with masking tape. Since the tape will not slip, it will provide a positive marking during the swaging process.

(c) After swaging, check the tape marker to make certain that the cable did not slip during the swaging operation.

(d) Remove the tape and paint the junction of the swaged fitting and cable with red tape.

(e) At all subsequent service inspec­ tions of the swaged fitting, check for a gap in the painted section to see if cable slippage has occurred.

b. Nicopress Process. A patented process using copper sleeves may be used up to the full rated strength of the cable when the cable is looped around a thimble. This process may also be used in place of the five-tuck splice on Page 7-32 Par 7-148

Page 342Open in PDF

cables up to and including 3/8 inch diameter.

The use of sleeves that are fabricated of mate­ rials other than copper will require engineering approval for the specific application by the FAA.

(1) Before undertaking a nicopress splice, determine the proper tool and sleeve for the cable to be used. Refer to table 7-6 and ta­ ble 7-7 for details on sleeves, tools, and the number of presses required for the various sizes of aircraft cable. The tool must be in good working condition and properly adjusted to ensure a satisfactory splice.

(2) To compress a sleeve, have it wellcentered in the tool groove with the major axis of the sleeve at right angles to the tool. If the sleeve appears to be out of line after the press is started, open the tool, re-center the sleeve, and complete the press.

c. Thimble-Eye Splice. Before under­ taking a thimble-eye splice, initially position the cable so the end will extend slightly be­ yond the sleeve, as the sleeve will elongate somewhat when it is compressed. If the cable end is inside the sleeve, the splice may not hold the full strength of the cable. It is desir­ able that the oval sleeve be placed in close proximity to the thimble points, so that when compressed, the sleeve will contact the thimble as shown in figure 7-14. The sharp ends of the thimble may be cut off before being used;

however, make certain the thimble is firmly secured in the cable loop after the splice has been completed. When using a sleeve requir­ ing three compressions, make the center com­ pression first, the compression next to the thimble second, and the one farthest from the thimble last.

d. Lap Splice. Lap or running splices may also be made with copper oval sleeves.

When making such splices, it is usually neces­ sary to use two sleeves to develop the full FIGURE 7-14. Typical thimble-eye splice.

strength of the cable. The sleeves should be positioned as shown in figure 7-12(b), and the compressions made in the order shown. As in the case of eye splices, it is desirable to have the cable ends extend beyond the sleeves suffi­ ciently to allow for the increased length of the compressed sleeves.

e. Stop Sleeves. Stop sleeves may be used for special cable end and intermediate fittings.

They are installed in the same manner as nico­ press oval sleeves.

NOTE: All stop sleeves are plain cop - per. Certain sizes are colored for identification.

f. Terminal Gauge. To make a satisfac­ tory copper sleeve installation, it is important that the amount of sleeve pressure be kept uni­ form. The completed sleeves should be checked periodically with the proper gauge.

Hold the gauge so that it contacts the major axis of the sleeve. The compressed portion at the center of the sleeve should enter the gauge opening with very little clearance, as shown in figure 7-15. If it does not, the tool must be adjusted accordingly.

g. Other Applications. The preceding in­ formation regarding copper oval sleeves and stop sleeves is based on tests made with flexi­ ble aircraft cable. The sleeves may also be Par 7-148 Page 7-33

Page 343Open in PDF

TABLE 7-6. Copper oval sleeve data.

Copper oval sleeve stock No.

Cable size Plain Plated* Manual tool No.

Sleeve length before compression (approx.)

(inches) Sleeve length after compression (approx.)

(inches) Number of presses Tested strength (pounds) 3/64 18-11-B4 28-11-B4 51-B4-887 3/8 7/16 1 340 1/16 18-1-C 28-1-C 51-C-887 3/8 7/16 1 550 3/32 18-2-G 28-2-G 51-G-887 7/16 1/2 1 1,180 1/8 18-3-M 28-3-M 51-M-850 9/16 3/4 3 2,300 5/32 18-4-P 28-4-P 51-P-850 5/8 7/8 3 3,050 3/16 18-6-X 28-6-X 51-X-850 1 1 1/4 4 4,350 7/32 18-8-F2 28-8-F2 51-F2-850 7/8 1 1/16 4 5,790 1/4 18-10-F6 28-10-F6 3-F6-950 1 1/8 1 1/2 3 7,180 5/16 18-13-G9 28-13-G9 3-G9-950 1 1/4 1 5/8 3 11,130 No. 635 Hydraulic tool dies 3/8 18-23-H5 28-23-H5 Oval H5 1 1/2 1 7/8 1 16,800 7/16 18-24-J8 28-24-J8 Oval J8 1 3/4 2 1/8 2 19,700 1/2 18-25-K8 28-25-K8 Oval K8 1 7/8 2 1/2 2 25,200 9/16 18-27-M1 28-27-M1 Oval M1 2 2 5/8 3 31,025 5/8 18-28-N5 28-28-N5 Oval N5 2 3/8 3 1/8 3 39,200 *Required on stainless cables due to electrolysis caused by different types of metals.

TABLE 7-7. Copper stop sleeve data.

Cable size (inch) Sleeve No. Tool No. Sleeve Sleeve Tested strength (pounds) 3/64 871-12-B4 51-B4-887 7/32 11/64 280 1/16 871-1-C 51-C-887 7/32 13/64 525 3/32 871-17-J (Yellow) 51-MJ 5/16 21/64 600 1/8 S71-18-J (Red) 51-MJ 5/16 21/64 800 5/32 871-19-M 51-MJ 5/16 27/64 1,200 3/16 871-20-M (Black) 51-MJ 5/16 27/64 1,600 7/32 871-22-M 51-MJ 5/8 7/16 2,300 1/4 871-23-F6 3-F6-950 11/16 21/32 3,500 5/16 871-26-F6 3-F6-950 11/16 21/32 3,800 NOTE: All stop sleeves are plain copper. Certain sizes are colored for identification.

used on wire ropes of other construction, if each specific type of cable is proof-tested ini­ tially. Because of variation in rope strengths, grades, construction, and actual diameters, the test is necessary to insure proper selection of materials, the correct pressing procedure, and an adequate margin of safety for the intended use. FIGURE 7-15. Typical terminal gauge.