AC 43.13-1B

Change 1Historical

Advisory circular · Acceptable Methods, Techniques, and Practices—Aircraft Inspection and Repair

A newer version is currentThis is a historical version. AC 43.13-1B CHG 1 Ed Update is the version in force, approved September 27, 2001.
Approved
September 9, 1998
Last reviewed
June 11, 2024
Cancels
AC43.13-1B
Family
AC 43.13-1 · 7 versions
Revision
B, change 1
14 CFR parts
43, 65, 145, 21, 105, 23, 91, 121, 25
Cited by
95 ADs

Guidance, not mandatory unless a rule or AD requires it. DRS record last changed November 21, 2025.

Show pages 325–336
Page 337Open in PDF

TABLE 7-3. Flexible cable construction and physical properties.

MINIMUM BREAKING STRENGTH (Pounds)

NOMINAL

DIAMETER

OF WIRE ROPE CABLE

CONSTRUCTION

TOLERANCE ON

DIAMETER (PLUS ONLY)

ALLOWABLE

INCREASE OF

DIAMETER AT

CUT END MIL-W- 83420 COMP A MIL-W- 83420 COMP B (CRES) MIL-C- 18375 (CRES)

INCHES INCHES INCHES LBS LBS LBS 1/32 3 x 7 0.006 0.006 110 110 3/64 7 x 7 0.008 0.008 270 270 1/16 7 x 7 0.010 0.009 480 480 360 1/16 7 x 19 0.010 0.009 480 480 3/32 7 x 7 0.012 0.010 920 920 700 3/32 7 x 19 0.012 0.010 1,000 920 1/8 7 x 19 0.014 0.011 2,000 1,760 1,300 5/32 7 x 19 0.016 0.017 2,800 2,400 2,000 3/16 7 x 19 0.018 0.019 4,200 3,700 2,900 7/32 7 x 19 0.018 0.020 5,600 5,000 3,800 1/4 7 x 19 0.018 0.021 7,000 6,400 4,900 9/32 7 x 19 0.020 0.023 8,000 7,800 6,100 5/16 7 x 19 0.022 0.024 9,800 9,000 7,600 11/32 7 x 19 0.024 0.025 12,500 3/8 7 x 19 0.026 0.027 14,400 12,000 11,000 7/16 6 x 19 IWRC 0.030 0.030 17,600 16,300 14,900 1/2 6 x 19 IWRC 0.033 0.033 22,800 22,800 19,300 9/16 6 x 19 IWRC 0.036 0.036 28,500 28,500 24,300 5/8 6 x 19 IWRC 0.039 0.039 35,000 35,000 30,100 3/4 6 x 19 IWRC 0.045 0.045 49,600 49,600 42,900 7/8 6 x 19 IWRC 0.048 0.048 66,500 66,500 58,000 1 6 x 19 IWRC 0.050 0.050 85,400 85,400 75,200 1 - 1/8 6 x 19 IWRC 0.054 0.054 106,400 106,400 1 - 1/4 6 x 19 IWRC 0.057 0.057 129,400 129,400 1 - 3/8 6 x 19 IWRC 0.060 0.060 153,600 153,600 1 - 1/2 6 x 19 IWRC 0.062 0.062 180,500 180,500 is caused by friction between strands and be­ tween wires. In bare cable, this is aggravated by dirt and grit working its way into the cable;

and the lubricant working its way out leaving dry, dirty wires rubbing against each other. In long, straight runs of cable, vibration workhardens the wires causing the brittle wires to fracture with eventual failure of the cable.

c. The nylon-jacket protects the cable in a threefold manner. It keeps the lubricant from oozing out and evaporating, it keeps dirt and grit out, and it dampens the vibrations, thereby, greatly reducing their effect on the ca­ ble.

7-144. NONFLEXIBLE CABLES. (Refer to table 7-4 and figure 7-9.) Nonflexible, pre­ formed, carbon steel cables, MIL-W-87161, composition A, are manufactured by the same processes as MIL-W-83420, composition B, flexible corrosion-resistant steel cables. The nonflexible steel cables are of the 1 by 7 (Type I) or 1 by 19 (Type II) construction ac­ cording to the diameter as specified in ta­ ble 7-4. The 1 by 7 cable consists of six Page 7-28 Par 7-143

Page 338Open in PDF

FIGURE 7-8. Flexible cable cross section.

TABLE 7-4. Nonflexible cable construction and physical properties.

STRAND TYPE

NOMINAL

DIAMETER OF WIRE STRAND In.

TOLERANCE ON

DIAMETER (Plus Only) In.

ALLOWABLE

INCREASE IN

DIAMETER

AT THE END In.

CONSTRUCTION MIL-W-87161

MINIMUM BREAK

STRENGTH

COMP A & B Lbs.

I 1/32 0.003 0.006 1 x 7 185 I 3/64 0.005 0.008 1 x 7 375 II 3/64 0.005 0.008 1 x 19 375 I 1/16 0.006 0.009 1 x 7 500 II 1/16 0.006 0.009 1 x 19 500 II 5/64 0.008 0.009 1 x 19 800 II 3/32 0.009 0.010 1 x 19 1,200 II 7/64 0.009 0.010 1 x 19 1,600 II 1/8 0.013 0.011 1 x 19 2,100 II 5/32 0.013 0.016 1 x 19 3,300 II 3/16 0.013 0.019 1 x 19 4,700 II 7/32 0.015 0.020 1 x 19 6,300 II 1/4 0.018 0.021 1 x 19 8,200 II 5/16 0.022 0.024 1 x 19 12,500 II 3/8 0.026 0.027 1 x 19 17,500 FIGURE 7-9. Nonflexible cable cross section.

wires laid around a center wire in a counter­ clockwise direction. The 1 by 19 cable con­ sists of a layer of six wires laid around a center wire in a clockwise direction plus twelve wires laid around the inner strand in a counterclock­ wise direction.

7-145. CABLE SPECIFICATIONS. Cable diameter and strength data are given in ta­ ble 7-3 and table 7-4. These values are accept­ able for repair and modification of civil air­ craft.

7-146. CABLE PROOF LOADS. Cable terminals and splices should be tested for proper strength before installation. Gradually apply a test load equal to 60 percent of the ca­ ble-breaking strengths given in table 7-3 and Par 7-144 Page 7-29

Page 339Open in PDF

table 7-4, for a period of 3 minutes. Place a suitable guard over the cable during the test to prevent injury to personnel in the event of ca­ ble failure.

7-147. REPLACEMENT OF CABLES.

Replace control cables when they become worn, distorted, corroded, or otherwise dam­ aged. If spare cables are not available, prepare exact duplicates of the damaged cable. Use materials of the same size and quality as the original. Standard swaged cable terminals de­ velop the full cable strength and may be sub­ stituted for the original terminals wherever practical. However, if facilities and supplies are limited and immediate corrective action is necessary, repairs may be made by using cable bushings, eye splices, and the proper combina­ tion of turnbuckles in place of the original in­ stallation. (See figure 7-12(c).)

a. Location of Splices. Locate splices so that no portion of the splice comes closer than 2 inches to any fair-lead or pulley. Locate connections at points where jamming cannot occur during any portion of the travel of either the loaded cable or the slack cable in the de­ flected position.

b. Cutting and Heating. Cut cables to length by mechanical means. The use of a torch, in any manner, is not permitted. Do not subject wires and cables to excessive tem­ perature. Soldering the bonding braid to the control cable is not permitted.

c. Ball-and-Socket Type Terminals. Do not use ball-and-socket type terminals or other types for general replacement that do not posi­ tively prevent cable untwisting, except where they were utilized on the original installation by the aircraft manufacturer.

d. Substitution of Cable. Substitution of cable for hard or streamlined wires will not be acceptable unless specifically approved by a representative of the FAA.

7-148. MECHANICALLY-FABRI- CATED CABLE ASSEMBLIES.

a. Swage-Type Terminals. Swage-type terminals, manufactured in accordance with AN, are suitable for use in civil aircraft up to, and including, maximum cable loads. When swaging tools are used, it is important that all the manufacturers’ instructions, including “go and no-go” dimensions, be followed in detail to avoid defective and inferior swaging. Ob­ servance of all instructions should result in a terminal developing the full-rated strength of the cable. Critical dimensions, both before and after swaging, are shown in table 7-5.

(1) Terminals. When swaging terminals onto cable ends, observe the following proce­ dures.

(a) Cut the cable to the proper length allowing for growth during swaging. Apply a preservative compound to the cable ends be­ fore insertion into the terminal barrel.

NOTE: Never solder cable ends to prevent fraying, since the presence of the solder will greatly increase the tendency of the cable to pull out of the terminal.

(b) Insert the cable into the terminal approximately 1 inch, and bend toward the terminal, then push the cable end entirely into the terminal barrel. The bending action puts a kink or bend in the cable end, and provides enough friction to hold the terminal in place until the swaging operation can be performed.

Bending also tends to separate the strands in­ side the barrel, thereby reducing the strain on them.

Page 7-30 Par 7-146

Page 340Open in PDF

TABLE 7-5. Straight-shank terminal dimensions. (Cross reference AN to MS: AN-666 to MS 21259, AN-667 to MS 20667, AN-668 to MS 20668, AN-669 to MS 21260.)

Before swaging After swaging Cable size (inches) Wire strands Outside diameter Bore diameter Bore length Swaging length Minimum breaking strength (pounds) Shank diameter * 1/16 7 x 7 0.160 0.078 1.042 0.969 480 0.138 3/32 7 x 7 .218 .109 1.261 1.188 920 .190 1/8 7 x 19 .250 .141 1.511 1.438 2,000 .219 5/32 7 x 19 .297 .172 1.761 1.688 2,800 .250 3/16 7 x 19 .359 .203 2.011 1.938 4,200 .313 7/32 7 x 19 .427 .234 2.261 2.188 5,600 .375 1/4 7 x 19 .494 .265 2.511 2.438 7,000 .438 9/32 7 x 19 .563 .297 2.761 2.688 8,000 .500 5/16 7 x 19 .635 .328 3.011 2.938 9,800 .563 3/8 7 x 19 .703 .390 3.510 3.438 14,400 .625 *Use gauges in kit for checking diameters.

NOTE: If the terminal is drilled com - pletely through, push the cable into the terminal until it reaches the approximate position shown in figure 7-10. If the hole is not drilled through, insert the cable until the end rests against the bottom of the hole.

FIGURE 7-10. Insertion of cable into terminal.

(c) Accomplish the swaging opera­ tion in accordance with the instructions fur­ nished by the manufacturer of the swaging equipment.

(d) Inspect the terminal after swaging to determine that it is free from the die marks and splits, and is not out-of-round. Check for cable slippage in the terminal and for cut or broken wire strands.

(e) Using a “go no-go” gauge or a micrometer, check the terminal shank diameter as shown in figure 7-11 and table 7-5.

FIGURE 7-11. Gauging terminal shank after swaging.

(f) Test the cable by proof-loading it to 60 percent of its rated breaking strength.

(2) Splicing. Completely severed ca­ bles, or those badly damaged in a localized area, may be repaired by the use of an eye Par 7-148 Page 7-31

Page 341Open in PDF

terminal bolted to a clevis terminal. (See fig­ ure 7-12(a).) However, this type of splice can only be used in free lengths of cable which do not pass over pulleys or through fair-leads.

FIGURE 7-12. Typical cable splices.

(3) Swaged ball terminals. On some aircraft cables, swaged ball terminals are used for attaching cables to quadrants and special connections where space is limited. Single shank terminals are generally used at the cable ends, and double shank fittings may be used at either the end or in the center of the cable.

Dies are supplied with the swaging machines for attaching these terminals to cables by the following method.

(a) The steel balls and shanks have a hole through the center, and are slipped over the cable and positioned in the desired loca­ tion.

(b) Perform the swaging operation in accordance with the instructions furnished by the manufacturer of the swaging equipment.

(c) Check the swaged fitting with a “go no-go” gauge to see that the fitting is properly compressed, and inspect the physical condition of the finished terminal. (See fig­ ure 7-13.)

FIGURE 7-13. Typical terminal gauge.

(4) Cable slippage in terminal. Ensure that the cable is properly inserted in the termi­ nal after the swaging operation is completed.

Instances have been noted wherein only 1/4 inch of the cable was swaged in the termi­ nal. Observance of the following precautions should minimize this possibility.

(a) Measure the length of the termi­ nal end of the fitting to determine the proper length of cable to be inserted into the barrel of the fitting.

(b) Lay off this length at the end of the cable and mark with masking tape. Since the tape will not slip, it will provide a positive marking during the swaging process.

(c) After swaging, check the tape marker to make certain that the cable did not slip during the swaging operation.

(d) Remove the tape and paint the junction of the swaged fitting and cable with red tape.

(e) At all subsequent service inspec­ tions of the swaged fitting, check for a gap in the painted section to see if cable slippage has occurred.

b. Nicopress Process. A patented process using copper sleeves may be used up to the full rated strength of the cable when the cable is looped around a thimble. This process may also be used in place of the five-tuck splice on Page 7-32 Par 7-148

Page 342Open in PDF

cables up to and including 3/8 inch diameter.

The use of sleeves that are fabricated of mate­ rials other than copper will require engineering approval for the specific application by the FAA.

(1) Before undertaking a nicopress splice, determine the proper tool and sleeve for the cable to be used. Refer to table 7-6 and ta­ ble 7-7 for details on sleeves, tools, and the number of presses required for the various sizes of aircraft cable. The tool must be in good working condition and properly adjusted to ensure a satisfactory splice.

(2) To compress a sleeve, have it wellcentered in the tool groove with the major axis of the sleeve at right angles to the tool. If the sleeve appears to be out of line after the press is started, open the tool, re-center the sleeve, and complete the press.

c. Thimble-Eye Splice. Before under­ taking a thimble-eye splice, initially position the cable so the end will extend slightly be­ yond the sleeve, as the sleeve will elongate somewhat when it is compressed. If the cable end is inside the sleeve, the splice may not hold the full strength of the cable. It is desir­ able that the oval sleeve be placed in close proximity to the thimble points, so that when compressed, the sleeve will contact the thimble as shown in figure 7-14. The sharp ends of the thimble may be cut off before being used;

however, make certain the thimble is firmly secured in the cable loop after the splice has been completed. When using a sleeve requir­ ing three compressions, make the center com­ pression first, the compression next to the thimble second, and the one farthest from the thimble last.

d. Lap Splice. Lap or running splices may also be made with copper oval sleeves.

When making such splices, it is usually neces­ sary to use two sleeves to develop the full FIGURE 7-14. Typical thimble-eye splice.

strength of the cable. The sleeves should be positioned as shown in figure 7-12(b), and the compressions made in the order shown. As in the case of eye splices, it is desirable to have the cable ends extend beyond the sleeves suffi­ ciently to allow for the increased length of the compressed sleeves.

e. Stop Sleeves. Stop sleeves may be used for special cable end and intermediate fittings.

They are installed in the same manner as nico­ press oval sleeves.

NOTE: All stop sleeves are plain cop - per. Certain sizes are colored for identification.

f. Terminal Gauge. To make a satisfac­ tory copper sleeve installation, it is important that the amount of sleeve pressure be kept uni­ form. The completed sleeves should be checked periodically with the proper gauge.

Hold the gauge so that it contacts the major axis of the sleeve. The compressed portion at the center of the sleeve should enter the gauge opening with very little clearance, as shown in figure 7-15. If it does not, the tool must be adjusted accordingly.

g. Other Applications. The preceding in­ formation regarding copper oval sleeves and stop sleeves is based on tests made with flexi­ ble aircraft cable. The sleeves may also be Par 7-148 Page 7-33

Page 343Open in PDF

TABLE 7-6. Copper oval sleeve data.

Copper oval sleeve stock No.

Cable size Plain Plated* Manual tool No.

Sleeve length before compression (approx.)

(inches) Sleeve length after compression (approx.)

(inches) Number of presses Tested strength (pounds) 3/64 18-11-B4 28-11-B4 51-B4-887 3/8 7/16 1 340 1/16 18-1-C 28-1-C 51-C-887 3/8 7/16 1 550 3/32 18-2-G 28-2-G 51-G-887 7/16 1/2 1 1,180 1/8 18-3-M 28-3-M 51-M-850 9/16 3/4 3 2,300 5/32 18-4-P 28-4-P 51-P-850 5/8 7/8 3 3,050 3/16 18-6-X 28-6-X 51-X-850 1 1 1/4 4 4,350 7/32 18-8-F2 28-8-F2 51-F2-850 7/8 1 1/16 4 5,790 1/4 18-10-F6 28-10-F6 3-F6-950 1 1/8 1 1/2 3 7,180 5/16 18-13-G9 28-13-G9 3-G9-950 1 1/4 1 5/8 3 11,130 No. 635 Hydraulic tool dies 3/8 18-23-H5 28-23-H5 Oval H5 1 1/2 1 7/8 1 16,800 7/16 18-24-J8 28-24-J8 Oval J8 1 3/4 2 1/8 2 19,700 1/2 18-25-K8 28-25-K8 Oval K8 1 7/8 2 1/2 2 25,200 9/16 18-27-M1 28-27-M1 Oval M1 2 2 5/8 3 31,025 5/8 18-28-N5 28-28-N5 Oval N5 2 3/8 3 1/8 3 39,200 *Required on stainless cables due to electrolysis caused by different types of metals.

TABLE 7-7. Copper stop sleeve data.

Cable size (inch) Sleeve No. Tool No. Sleeve Sleeve Tested strength (pounds) 3/64 871-12-B4 51-B4-887 7/32 11/64 280 1/16 871-1-C 51-C-887 7/32 13/64 525 3/32 871-17-J (Yellow) 51-MJ 5/16 21/64 600 1/8 S71-18-J (Red) 51-MJ 5/16 21/64 800 5/32 871-19-M 51-MJ 5/16 27/64 1,200 3/16 871-20-M (Black) 51-MJ 5/16 27/64 1,600 7/32 871-22-M 51-MJ 5/8 7/16 2,300 1/4 871-23-F6 3-F6-950 11/16 21/32 3,500 5/16 871-26-F6 3-F6-950 11/16 21/32 3,800 NOTE: All stop sleeves are plain copper. Certain sizes are colored for identification.

used on wire ropes of other construction, if each specific type of cable is proof-tested ini­ tially. Because of variation in rope strengths, grades, construction, and actual diameters, the test is necessary to insure proper selection of materials, the correct pressing procedure, and an adequate margin of safety for the intended use. FIGURE 7-15. Typical terminal gauge.

Page 7-34 Par 7-148

Page 344Open in PDF

7-149. CABLE SYSTEM INSPECTION.

Aircraft cable systems are subject to a variety of environmental conditions and deterioration.

Wire or strand breakage is easy to visually rec­ ognize. Other kinds of deterioration such as wear, corrosion, and/or distortion are not easily seen; therefore, control cables should be re­ moved periodically for a more detailed inspec­ tion.

a. At each annual or 100 hour inspec - tion, all control cables must be inspected for broken wires strands. Any cable assembly that has one broken wire strand located in a critical fatigue area must be replaced.

b. A critical fatigue area is defined as the working length of a cable where the cable runs over, under, or around a pulley, sleeve, or through a fair-lead; or any section where the cable is flexed, rubbed, or worked in any man­ ner; or any point within 1 foot of a swaged-on fitting.

c. A swaged-on fitting can be an eye, fork, ball, ball and shank, ball and double shank, threaded stud, threaded stud and turn­ buckle, compression sleeve, or any hardware used as a termination or end fitting on the ca­ ble. These fittings may be attached by various swaging methods such as rotary swaging, roll swaging, hydraulic pressing, and hand swaging tools. (See MIL-T-781.) The pressures ex­ erted on the fittings during the swaging proc­ ess sometimes pinch the small wires in the ca­ ble. This can cause premature failure of the pinched wires, resulting in broken wires.

d. Close inspection in these critical fa - tigue areas, must be made by passing a cloth over the area to snag on broken wires. This will clean the cable for a visual inspection, and detect broken wires if the cloth snags on the cable. Also, a very careful visual inspection must be made since a broken wire will not al­ ways protrude or stick out, but may lie in the strand and remain in the position of the helix as it was manufactured. Broken wires of this type may show up as a hairline crack in the wire. If a broken wire of this type is sus­ pected, further inspection with a magnifying glass of 7 power or greater, is recommended.

Figure 7-16 shows a cable with broken wires that was not detected by wiping, but was found during a visual inspection. The damage be­ came readily apparent when the cable was re­ moved and bent as shown in figure 7-16.

FIGURE 7-16. Cable inspection technique.

e. Kinking of wire cable can be avoided if properly handled and installed. Kinking is caused by the cable taking a spiral shape as the result of unnatural twist. One of the most common causes for this twist is improper un­ reeling and uncoiling. In a kinked cable, strands and wires are out of position, which creates unequal tension and brings excessive wear at this part of the cable. Even though the kink may be straightened so that the damage appears to be slight, the relative adjustment between the strands has been disturbed so that the cable cannot give maximum service and should be replaced. Inspect cables for a popped core or loose strands. Replace any ca­ ble that has a popped core or loose strands re­ gardless of wear or broken wires.

Par 7-149 Page 7-35

Page 345Open in PDF

f. Nylon-jacketed cable with any cracks or necking down in the diameter of the jacket shall be replaced. Usable cable life is over when these conditions begin to appear in the nylon jacket.

g. External wear patterns will extend along the cable equal to the distance the cable moves at that location and may occur on one side of the cable or on its entire circumference.

Replace flexible and nonflexible cables when the individual wires in each strand appear to blend together (outer wires worn 40 to 50 per­ cent) as depicted in figure 7-17. Actual in­ stances of cable wear beyond the recom­ mended replacement point are shown in fig­ ure 7-18.

FIGURE 7-17. Cable wear patterns.

h. As wear is taking place on the exterior surface of a cable, the same condition is taking place internally, particularly in the sections of the cable which pass over pulleys and quad­ rants. This condition (shown in figure 7-19) is not easily detected unless the strands of the ca­ ble are separated. This type of wear is a result of the relative motion between inner wire sur­ faces. Under certain conditions, the rate of this type of wear can be greater than that occurring on the surface.

FIGURE 7-18. Worn cable (replacement necessary).

i. Areas especially conducive to cable corrosion are battery compartments, lavatories, wheel wells, etc.; where a concentration of corrosive fumes, vapors, and liquids can ac­ cumulate. Carefully examine any cable for corrosion, when it has a broken wire in a sec­ tion that is not in contact with a wearproducing airframe component, such as a pul­ ley, fair-lead, etc. If the surface of the cable is corroded, relieve cable tension and carefully force the cable open by reverse twisting and visually inspect the interior. Corrosion on the interior strands of the cable constitutes failure, and the cable must be replaced. If no internal corrosion is detected, remove loose external rust and corrosion with a clean, dry, coarseweave rag, or fiber brush. Do not use metallic Page 7-36 Par 7-149

Page 346Open in PDF

FIGURE 7-19. Internal end view of cable wear.

wool or solvents to clean installed cables. Use of metallic wool will embed dissimilar metal particles in the cables and create further corro­ sion problems. Solvents will remove internal cable lubricant allowing cable strands to abrade and further corrode. After thorough cleaning, sparingly apply specification MIL-C-16173, grade 4, corrosion-preventive compound to cable. Do not apply the material so thick that it will interfere with the operation of cables at fair-leads, pulleys, or grooved bellcrank areas.

j. Examine cable runs for incorrect rout­ ing, fraying, twisting, or wear at fair-leads, pulleys, antiabrasion strips, and guards. Look for interference with adjacent structure, equipment, wiring, plumbing, and other con­ trols. Inspect cable systems for binding, full travel, and security of attaching hardware.

Check for slack in the cable system by at­ tempting to move the control column and/or pedals while the gust locks are installed on the control surfaces. With the gust locks removed, actuate the controls and check for friction or hard movement. These are indications that ex­ cessive cable tension exists.

NOTE: If the control movement is stiff after maintenance is performed on control surfaces, check for parallel cables twisted around each other, or cables connected in reverse.

k. Check swaged terminal reference marks for an indication of cable slippage within the fitting. Inspect the fitting assembly for distortion and/or broken strands at the ter­ minal. Ensure that all bearings and swivel fit­ tings (bolted or pinned) pivot freely to prevent binding and subsequent failure. Check turn­ buckles for proper thread exposure and broken or missing safety wires/clips.

l. Inspect pulleys for roughness, sharp edges, and presence of foreign material em­ bedded in the grooves. Examine pulley bear­ ings to ensure proper lubrication, smooth rota­ tion; and freedom from flat spots, dirt, and paint spray. During the inspection, rotate the pulleys, which only turn through a small arc, to provide a new bearing surface for the cable.

Maintain pulley alignment to prevent the cable from riding on the flanges and chafing against guards, covers, or adjacent structure. Check all pulley brackets and guards for damage, alignment, and security.

m. Various cable system malfunctions may be detected by analyzing pulley condi­ tions. These include such discrepancies as too much tension, misalignment, pulley bearing problems, and size mismatches between cables and pulleys. Examples of these condition are shown in figure 7-20.

Par 7-149 Page 7-37

Page 347Open in PDF

FIGURE 7-20. Pulley wear patterns.

n. Inspect fair-leads for wear, breakage, alignment, cleanliness, and security. Examine cable routing at fair-leads to ensure that defec­ tion angles are no greater than 3°€ maximum.

Determine that all guides and anti-abrasion strips are secure and in good condition.

o. Examine pressure seals for wear and/or material deterioration. Seal guards should be positioned to prevent jamming of a pulley in case pressure seal fails and pieces slide along the cable.

7-150. CORROSION AND RUST PRE - VENTION. To ensure a satisfactory service life for aircraft control cables, use a cable lu­ bricant to reduce internal friction and prevent corrosion.

a. If the cable is made from tinned steel, coat the cable with rust-preventive oil, and wipe off any excess. It should be noted that corrosion-resistant steel cable does not require this treatment for rust prevention.

b. Lubrication and corrosion preventive treatment of carbon steel cables may be ef­ fected simultaneously by application of com­ pound MIL-C-16173, grade 4, or MIL-C-11796, Class I. MIL-C-16173 com­ pound should be brushed, sprayed, or wiped on the cable to the extent it penetrates into the strands and adequately covers the cable sur­ faces. It will dry “tack free” in 24 hours at 77 °F. MIL-C-11796 compound is applied by dipping the cable for 1/2 minute into a tank of compound heated to 77 ° ± 5 °C (170 ° ± 9 °F) for 1/2 minute then removing it and wiping off the excess oil. (An example of cable corro­ sion, attributable to battery acid, is shown in figure 7-21.)

Page 7-38 Par 7-149

Page 348Open in PDF

FIGURE 7-21. Corrosion.

7-151. WIRE SPLICES. Standard manu­ facturing splices have been mistaken for de­ fects in the cable because individual wire end splices were visible after assembly of a fin­ ished cable length. In some instances, the pro­ cess of twisting outer strands around the core strand may also slightly flatten individual outer wires, particularly in the area of a wire splice.

This flattening is the result of die-sizing the cable, and does not affect the strength of the cable. These conditions (as shown in fig­ ure 7-22) are normal, and are not a cause for cable rejection.

FIGURE 7-22. Manufacturer’s wire splice.

7-152. CABLE MAINTENANCE. Fre­ quent inspections and preservation measures such as rust-prevention treatments for bare carbon steel cable areas, will help to extend cable service life. Where cables pass through fair-leads, pressure seals, or over pulleys, re­ move accumulated heavy coatings of corro­ sion-prevention compound. Provide corrosion protection for these cable sections by lubricat­ ing with a light coat of grease or generalpurpose, low-temperature oil.

7-153. CABLE TENSION ADJUST - MENT. Carefully adjust, control cable tension in accordance with the airframe manufacturer’s recommendations. On large aircraft, take the temperature of the immediate area into consid­ eration when using a tension meter. For long cable sections, use the average of two or three temperature readings to obtain accurate tension values. If necessary, compensate for extreme surface temperature variations that may be en­ countered if the aircraft is operated primarily in unusual geographic or climatic conditions such as arctic, arid, or tropic locations. Use rigging pins and gust locks, as necessary, to en­ sure satisfactory results. At the completion of rigging operations, check turnbuckle adjustment and safetying in accordance with section 10 of this chapter.

7-154.  7-164. [RESERVED.] Par 7-151 Page 7-39 (and 7-40)