AC 43.13-1B

Change 1Historical

Advisory circular · Acceptable Methods, Techniques, and Practices—Aircraft Inspection and Repair

A newer version is currentThis is a historical version. AC 43.13-1B CHG 1 Ed Update is the version in force, approved September 27, 2001.
Approved
September 9, 1998
Last reviewed
June 11, 2024
Cancels
AC43.13-1B
Family
AC 43.13-1 · 7 versions
Revision
B, change 1
14 CFR parts
43, 65, 145, 21, 105, 23, 91, 121, 25
Cited by
95 ADs

Guidance, not mandatory unless a rule or AD requires it. DRS record last changed November 21, 2025.

Show pages 421–432
Page 433Open in PDF

9-21. WHEEL INSTALLATION. Various procedures are used for installing wheel assemblies on an aircraft.

a. The axle should first be cleaned and inspected for surface damage, damage to the axle threads, and the general condition and security of bolts holding the axle onto the landing-gear leg. The wheel bearings should be cleaned and packed with approved grease. The wheel bearing and tire must be inspected and assem - bled. Many aircraft have specific torque requirements for the wheel-retaining nuts. These torque requirements may have two values specified. The retaining nut is first tightened to the higher value to seat the bearing. It is then backed off and tightened to the lower value specified. While tightening the wheel retaining nuts, the wheel should be rotated.

b. Great care should be exercised to see that the wheel-retaining nuts are not overtightened. In the absence of specific instructions, the wheel-retaining nut is tightened until bearing drag is felt. The nut is then backed off about one serration (castellation) or one-sixth turn before bending up the tab on the tab-lock washer or installing the cotter pin.

c. The grease cover or wheel cover, if used, is then installed. During this installation any required brake, air-pressure sensors, and speed-sensor components should be installed and connected, as appropriate, for the specific aircraft.

9-22.  9.24. [RESERVED.] Par 9-9 Page 9-12a (and 9-12b)

Page 434Open in PDF

SECTION 2. HYDRAULIC SYSTEMS

9-25. GENERAL. Hydraulic systems in aircraft provide a means for the operation of aircraft components. The operation of landing gear, flaps, flight control surfaces and brakes is largely accomplished with hydraulic power systems. Hydraulic system complexity varies from small aircraft that require fluid only for manual operation of the wheel brakes to large transport aircraft where the systems are large and complex. To achieve the necessary redun­ dancy and reliability, the system may consist of several subsystems. Each subsystem has a power generating device (pump) reservoir, ac­ cumulator, heat exchanger, filtering system, etc. System operating pressure may vary from a couple hundred psi in small aircraft and ro­ torcraft to several thousand psi in large trans­ ports. Generally, the larger the aircraft, the more mechanical work is required to control the aircraft’s various functions. Consequently, the system operating pressure increases ac­ cordingly. Primarily, hydraulic power is gen­ erated by either engine driven or electric motor driven pumps. The majority of hydraulic pumps are pressure compensated to provide a constant output pressure at a flow-rate de­ manded by the system. Some constant dis­ placement pumps with a relief valve are used on the smaller aircraft.

9-26. PURPOSES OF HYDRAULIC SYSTEMS. Hydraulic systems make possible the transmission of pressure and energy at the best weight per horsepower ratio.

9-27. TYPES OF HYDRAULIC FLUID.

There are three principal categories of hydrau­ lic fluids; mineral base fluids, polyalphaolefin base, and phosphate ester base fluids. When servicing a hydraulic system, the technician must be certain to use the correct category of replacement fluid. Hydraulic fluids are not necessarily compatible. For example, con­ tamination of the fire-resistant fluid MIL-H-83282 with MIL-H-5606 may render the MIL-H-83282 non fire-resistant.

a. Mineral-Base Fluids. MIL-H-5606, mineral oil-based hydraulic fluid is the oldest, dating back to the 1940’s. It is used in many systems, especially where the fire hazard is comparatively low. MIL-H-6083 is simply a rust-inhibited version of MIL-H-5606. They are completely interchangeable. Suppliers generally ship hydraulic components with MIL-H-6083.

b. Polyalphaolefin-Based Fluids.

MIL-H-83282, is a fire-resistant hydrogenated polyalphaolefin-based fluid developed in the 1960’s to overcome the flammability charac­ teristics of MIL-H-5606. MIL-H-83282 is sig­ nificantly more flame resistant than MIL-H-5606, but a disadvantage is the high viscosity at low temperature. It is generally limited to -40 �F. However, it can be used in the same system and with the same seals, gas­ kets, and hoses as MIL-H-5606.

MIL-H-46170 is the rust-inhibited version of MIL-H-83282. Small aircraft predominantly use MIL-H-5606 but some have switched to MIL-H-83282, if they can accommodate the high viscosity at low temperature.

c. Phosphate Ester-Based Fluid (Sky­ drol/Hyjet). These fluids are used in most commercial transport category aircraft, and are extremely fire-resistant. However, they are not fireproof and under certain conditions, they will burn. The earliest generation of these fluids was developed after World War II as a result of the growing number of aircraft hy­ draulic brake fires which drew the collective concern of the commercial aviation industry.

(1) Progressive development of these fluids occurred as a result of performance re­ quirements of newer aircraft designs. The Par 9-25 Page 9-13

Page 435Open in PDF

airframe manufacturers dubbed these new gen­ erations of hydraulic fluid as “types” based on their performance. Today, types IV and V fluids are used. Two distinct classes of type IV fluids exist based on their density: class I fluids are low density and class II are standard density. The class I fluids provide weight savings advantages versus class II. Monsanto and Exxon are the suppliers of the type IV phosphate ester-based aviation hydraulic flu­ ids.

(2) In addition to the type IV fluids that are currently in use, type V fluids are being developed in response to industry demands for a more thermally stable fluid at higher operat­ ing temperatures. Type V fluids will be more resistant to hydrolytic and oxidative degrada­ tion at high temperature than the type IV flu­ ids.

d. Materials of Construction. Hydraulic systems require the use of special accessories that are compatible with the hydraulic fluid.

Appropriate seals, gaskets, and hoses must be specifically designated for the type of fluid in use. Care must be taken to ensure that the components installed in the system are com­ patible with the fluid. When gaskets, seals, and hoses are replaced, positive identification should be made to ensure that they are made of the appropriate material.

(1) Phosphate ester-based hydraulic fluids have good solvency properties and may act as plasticizer for certain polymers. Care should be taken in handling to keep the fluid from spilling on plastic materials and paint finishes.

(2) If a small amount of the fluid is spilled during handling, it must be cleaned up immediately with a dry cloth. When larger quantities are spilled, an absorbent sweeping compound is recommended. A final cleaning with an approved solvent or detergent should remove any traces of fluid.

9-28. HANDLING HYDRAULIC FLUID.

In addition to any other instructions provided in the aircraft maintenance manual or by the fluid supplier, the following general precau­ tions must be observed in the handling of hy­ draulic fluids:

a. Ensure that each aircraft hydraulic system is properly identified to show the kind of fluid to be used in the system. Identification at the filler cap or valve must clearly show the type of fluid to be used or added.

b. Never allow different categories of hy­ draulic fluids to become mixed. Chemical re­ actions may occur, fire resistant fluids may lose their fire resistance, seals may be dam­ aged, etc.

c. Never, under any circumstances, serv­ ice an aircraft system with a fluid different from that shown on the instruction plate.

d. Make certain that hydraulic fluids and fluid containers are protected from contamina­ tion of any kind. Dirt particles may cause hy­ draulic units to become inoperative, cause seal damage, etc. If there is any question regarding the cleanliness of the fluid, do not use it.

Containers for hydraulic fluid must never be left open to air longer than necessary.

e. Do not expose fluids to high tempera­ ture or open flames. Mineral-based fluids are highly flammable.

f. The hydrocarbon-based hydraulic fluids are, in general, safe to handle. To work with these fluids, reasonable handling proce­ dures must always be followed. Take precau­ tion to avoid fluid getting in the eyes. If fluid contacts the eye, wash immediately with water.

Page 9-14 Par 9-27

Page 436Open in PDF

g. When handling Skydrol/Hyjet hydraulic fluids, gloves that are impervious to the fluid must be worn. If skin contact occurs, wash with soap and water.

h. When handling phosphate esterbased fluid use eye protection. If the eye is exposed to fluid, severe eye pain will occur.

i. When Skydrol/Hyjet mist or vapor exposure is possible, a respirator capable of removing organic vapors and mists must be worn.

j. Ingestion of any hydraulic fluid should be avoided. Although small amounts do not appear to be highly hazardous, any sig­ nificant amount should be tested in accordance with manufacturer’s direction, followed with hospital supervised stomach treatment.

9-29. HYDRAULIC SYSTEM MAINTE - NANCE PRACTICES. The maintenance of hydraulic and pneumatic systems should be performed in accordance with the aircraft manufacturer’s instructions. The following is a summary of general practices followed when dealing with hydraulic and pneumatic systems.

a. Service. The servicing of hydraulic and pneumatic systems should be performed at the intervals specified by the manufacturer. Some components, such as hydraulic reservoirs, have servicing information adjacent to the compo­ nent. When servicing a hydraulic reservoir, make certain to use the correct type of fluid.

Hydraulic fluid type can be identified by color and smell; however, it is good practice to take fluid from the original marked container and then to check the fluid by color and smell for verification. Fluid containers should always be closed, except when fluid is being removed.

b. Contamination Control. Contamina­ tion, both particulate and chemical, is detri­ mental to the performance and life of compo­ nents in the aircraft hydraulic system. Con­ tamination enters the system through normal wear of components, by ingestion through ex­ ternal seals, during servicing, or maintenance when the system is opened to replace/repair components, etc. To control the particulate contamination in the system, filters are in­ stalled in the pressure line, in the return line, and in the pump case drain line of each system.

The filter rating is given in terms of “micron,” and is an indication of the particle size that will be filtered out. The replacement interval of these filters is established by the manufac­ turer and is included in the maintenance man­ ual. However, in the absence of specific re­ placement instructions, a recommended serv­ ice life of the filter elements is:

Pressure filters3000 hrs.

Return Filters1500 hrs.

Case drain filters600 hrs.

(1) When replacing filter elements, be sure that there is no pressure on the filter bowl.

Protective clothing and a face shield must be used to prevent fluid from contacting the eye.

Replace the element with one that has the proper rating. After the filter element has been replaced, the system must be pressure tested to ensure that the sealing element in the filter as­ sembly is intact.

(2) In the event of a major component failure, such as a pump, consideration must be given to replacing the system filter elements, as well as the failed component. System filters may also be equipped with differential pres­ sure (∆P) indicators. These indicators are de­ signed to “pop-up” when the pressure drop across the element reaches a predetermined value caused by contamination held by the element. The indicators are designed to pre­ vent false indications due to cold start, pump ripple, and shock loads. Consequently, a filter whose indicator has been activated must be re­ placed. In fact, some indicator designs are Par 9-28 Page 9-15

Page 437Open in PDF

such that the indicator cannot be reset, unless the filter bowl is removed and the element re­ placed.

c. Flushing a Hydraulic System. When inspection of hydraulic filters or hydraulic fluid evaluation indicates that the fluid is con­ taminated, flushing the system may be neces­ sary. This must be done according to the manufacturer’s instructions; however, a typical procedure for flushing is as follows:

(1) Connect a ground hydraulic test stand to the inlet and outlet test ports of the system. Verify that the ground unit fluid is clean and contains the same fluid as the air­ craft.

(2) Change the system filters.

(3) Pump clean, filtered fluid through the system, and operate all subsystems until no obvious signs of contamination are found during inspection of the filters. Dispose of contaminated fluid and filter. (Note: A visual inspection of hydraulic filters is not always ef­ fective.)

(4) Disconnect the test stand and cap the ports.

(5) Ensure that the reservoir is filled to the FULL line or proper service level.

d. Inspections. Hydraulic and pneumatic systems are inspected for leakage, worn or damaged tubing, worn or damaged hoses, wear of moving parts, security of mounting for all units, safetying, and any other condition speci­ fied by the maintenance manual. A complete inspection includes considering the age, cure date, stiffness of the hose, and an operational check of all subsystems.

(1) Leakage from any stationary con­ nection in a system is not permitted, and if found, it should be repaired. A small amount of fluid seepage may be permitted on actuator piston rods and rotating shafts. In a hydraulic system, a thin film of fluid in these areas indi­ cates that the seals are being properly lubri­ cated. When a limited amount of leakage is allowed at any point, it is usually specified in the appropriate manual.

(2) Tubing should not be nicked, cut, dented, collapsed, or twisted beyond approved limits. The identification markings or lines on a flexible hose will show whether the hose has been twisted. (See figure 9.9.)

(3) All connections and fittings associ­ ated with moving units must be examined for play evidencing wear. Such units should be in an unpressurized condition when they are checked for wear.

(4) Accumulators must be checked for leakage, air or gas preload, and position. If the accumulator is equipped with a pressure gauge, the preload can be read directly.

(5) An operational check of the system can be performed using the engine-driven pump, an electrically-operated auxiliary pump (if such a pump is included in the system), or a ground test unit. The entire system and each subsystem should be checked for smooth op­ eration, unusual noises, and speed of operation for each unit. The pressure section of the sys­ tem should be checked with no subsystems to see that pressure holds for the required time without the pump supplying the system. Sys­ tem pressure should be observed during opera­ tion of each subsystem to ensure that the en­ gine-driven pump maintains the required pres­ sure.

e. Troubleshooting. Hydraulic system troubleshooting varies according to the com­ plexity of the system and the components in the system. It is, therefore, important that the Page 9-16 Par 9-29

Page 438Open in PDF

technician refer to the troubleshooting infor­ mation furnished by the manufacturer.

(1) Lack of pressure in a system can be caused by a sheared pump shaft, defective re­ lief valve, the pressure regulator, an unloading valve stuck in the “kicked-out” position, lack of fluid in the system, the check valve installed backward, or any condition that permits free flow back to the reservoir or overboard. If a system operates satisfactorily with a ground test unit but not with the system pump, the pump should be examined.

(2) If a system fails to hold pressure in the pressure section, the likely cause is the pressure regulator, an unloading valve, a leak­ ing relief valve, or a leaking check valve.

(3) If the pump fails to keep pressure up during operation of the subsystem, the pump may be worn or one of the pressure-control units may be leaking.

(4) High pressure in a system may be caused by a defective or improperly-adjusted pressure regulator, an unloading valve, or by an obstruction in a line or control unit.

(5) Unusual noise in a hydraulic system, such as banging and chattering, may be caused by air or contamination in the system. Such noises can also be caused by a faulty pressure regulator, another pressure-control unit, or a lack of proper accumulator action.

(6) Maintenance of hydraulic system components involves a number of standard practices together with specialized procedures set forth by manufacturers such as the re­ placement of valves, actuators, and other units, including tubing and hoses. Care should be exercised to prevent system contamination damage to seals, packings, and other parts, and to apply proper torque in connecting fittings.

When installing fittings, valves, etc. always lubricate the threads with hydraulic fluid.

(7) Overhaul of hydraulic and pneu­ matic units is usually accomplished in ap­ proved repair facilities; however, replacement of seals and packings may be done from time to time by technicians in the field. When a unit is disassembled, all O-ring and Chevron seals should be removed and replaced with new seals. The new seals must be of the same material as the original and must carry the cor­ rect manufacturer’s part number. No seal should be installed unless it is positively iden­ tified as the correct part and the shelf life has not expired.

(8) When installing seals, care should be exercised to ensure that the seal is not scratched, cut, or otherwise damaged. When it is necessary to install a seal over sharp edges, the edges must be covered with shim stock, plastic sheet, or electrical tape.

(9) The replacement of hydraulic units and tubing usually involves the spillage of some hydraulic fluid. Care should be taken to ensure that the spillage of fluid is kept to a minimum by closing valves, if available, and by plugging lines immediately after they are disconnected. All openings in hydraulic sys­ tems should be capped or plugged to prevent contamination of the system.

(10) The importance of the proper torque applied to all nuts and fittings in a sys­ tem cannot be over-emphasized. Too much torque will damage metal and seals, and too little torque will result in leaks and loose parts.

The proper torque wrenches with the appropri­ ate range should be used in assembling system units.

f. Disposal of Used Hydraulic Fluids. In the absence of organizational guidelines, the Par 9-29 Page 9-17

Page 439Open in PDF

technician should be guided by local, state, and federal regulations, with regard to means of disposal of used hydraulic fluid. Presently, the most universally accepted procedure for dis­ posal of phosphate ester-based fluid is incin­ eration.

9-30. HYDRAULIC LINES AND FIT - TINGS. Carefully inspect all lines and fittings at regular intervals to ensure airworthiness.

Investigate any evidence of fluid loss or leaks.

Check metal lines for leaks, loose anchorage, scratches, kinks, or other damage. Inspect fit­ tings and connections for leakage, looseness, cracks, burrs, or other damage. Replace or re­ pair defective elements. Make sure the lines and hoses do not chafe against one another and are correctly secured and clamped.

a. Replacement of Metal Lines. W h e n inspection shows a line to be damaged or de­ fective, replace the entire line or, if the dam­ aged section is localized, a repair section may be inserted. In replacing lines, always use tubing of the same size and material as the original line. Use the old tubing as a template in bending the new line, unless it is too greatly damaged, in which case a template can be made from soft iron wire. Soft aluminum tubing (1100, 3003, or 5052) under ¼-inch outside diameter may be bent by hand.. For all other tubing use an acceptable hand or power tube-bending tool. Bend tubing carefully to avoid excessive flattening, kinking, or wrin­ kling. Minimum bend radii values are shown in table 9-2. A small amount of flattening in bends is acceptable, but do not exceed 75 percent of the original outside diameter.

Excessive flattening will cause fatigue failure of the tube. When installing the replacement tubing, line it up correctly with the mating part so that it is not forced into alignment by tight­ ening of the coupling nuts.

b. Tube Connections. Many tube con­ nections are made using flared tube ends with standard connection fittings: AN-818 (MS 20818) nut and AN-819 (MS 20819) sleeve. In forming flares, cut the tube ends square, file smooth, remove all burrs and sharp edges, and thoroughly clean. The tubing is then flared using the correct 37-degree aviation flare forming tool for the size of tubing and type of fitting. A double flare is used on soft aluminum tubing 3/8-inch outside diameter and under, and a single flare on all other tub­ ing. In making the connections, use hydraulic fluid as a lubricant and then tighten. Overtightening will damage the tube or fitting, which may cause a failure. Under-tightening may cause leakage which could result in a system failure.

CAUTION: Mistaken use of 45-degree automotive flare forming tools may result in improper tubing flare shape and angle; causing misfit, stress and strain, and probable system failure.

c. Repair of Metal Tube Lines. Minor dents and scratches in tubing may be repaired.

Scratches or nicks not deeper than 10 percent of the wall thickness in aluminum alloy tubing, that are not in the heel of a bend, may be re­ paired by burnishing with hand tools. Replace lines with severe die marks, seams, or splits in the tube. Any crack or deformity in a flare is unacceptable and cause for rejection. A dent less than 20 percent of the tube diameter is not objectionable unless it is in the heel of a bend.

A severely-damaged line should be replaced;

however, it may be repaired by cutting out the damaged section and inserting a tube section of the same size and material. Flare both ends of the undamaged and replacement tube sec­ tions and make the connection by using stan­ dard unions, sleeves, and tube nuts. If the damaged portion is short enough, omit the in­ sert tube and repair by using one union and two sets of connection fittings.

Page 9-18 Par 9-29

Page 440Open in PDF

TABLE 9-2. Tube data.

Dash Nos.

Ref.

Tubing OD inches Wrench torque for tightening AN-818 Nut (pound inch) Minimum bend radii measured to tubing centerline. Dimension in inches.

Aluminum-alloy tubing Steel tubing Aluminum-alloy tubing (Flare MS33583) for use on oxygen lines only Minimum Maximum Minimum Maximum Minimum Maximum Alum.

Alloy Steel -2 1/8 20 30 75 85 -­ -­ 3/8 -­ -3 3/16 25 35 95 105 -­ -­ 7/16 21/32 -4 1/4 50 65 135 150 -­ -­ 9/16 7/8 -5 5/16 70 90 170 200 100 125 3/4 1-1/8 -6 3/8 110 130 270 300 200 250 15/16 1-5/16 -8 1/2 230 260 450 500 300 400 1-1/4 1-3/4 -10 5/8 330 360 650 700 -­ -­ 1-1/2 2-3/16 -12 3/4 460 500 900 1000 -­ -­ 1-3/4 2-5/8 -16 1 500 700 1200 1400 -­ -­ 3 3-1/2 -20 1-1/4 800 900 1520 1680 -­ -­ 3-3/4 4-3/8 -24 1-1/2 800 900 1900 2100 -­ -­ 5 5-1/4 -28 1-3/4 -­ -­ -­ -­ -­ -­ -­ -­ -32 2 1800 2000 2660 2940 -­ -­ 8 7

d. Replacement of Flexible Lines. When replacement of a flexible line is necessary, use the same type, size, part number, and length of hose as the line to be replaced. Check TSO requirements. If the replacement of a hose with a swaged-end type fitting is necessary, obtain a new hose assembly of the correct size and composition. Certain synthetic oils re­ quire a specially compounded synthetic rubber hose, which is compatible. Refer to the air­ craft manufacturer’s service information for the correct part number for the replacement hose. If the fittings on each end are of the cor­ rect type or sleeve type, a replacement may be fabricated as shown in figure 9-8. Before cut­ ting new flexible wire braided hose to the proper size, tape the hose tightly with masking tape and cut in the center of the masking tape to prevent fraying. The use of a mandrel will prevent cutting the inside of the hose when in­ serting the fittings. Typical aircraft hose speci­ fications and their uses are shown in table 9-3.

Install hose assemblies without twisting. (See figure 9-9.) A hose should not be stretched tight between two fittings as this will result in overstressing and eventual failure. The length of hose should be sufficient to provide about 5 to 8 percent slack. Avoid tight bends in flex lines as they may result in failure. Never exceed the minimum bend radii as indicated in figure 9-10.

(1) Teflon hose is used in many aircraft systems because it has superior qualities for certain applications. Teflon is compounded from tetrafluoroethylene resin which is unaf­ fected by fluids normally used in aircraft. It has an operating range of -65°F to 450 °F. For these reasons, Teflon is used in hydraulic and engine lubricating systems where temperatures and pressures preclude the use of rubber hose.

Although Teflon hose has excellent perform­ ance qualities, it also has peculiar characteris­ tics that require extra care in handling. It tends to assume a permanent set when exposed to high pressure or temperature. Do not attempt to straighten a hose that has been in service.

Any excessive bending or twisting may cause kinking or weakening of the tubing wall. Re­ place any hose that shows signs of leakage, abrasion, or kinking. Any hose suspected of kinking may be checked with a steel ball of proper size. Table 9-4 shows hose and ball sizes. The ball will not pass through if the hose is distorted beyond limits.

(2) If the hose fittings are of the reus­ able type, a replacement hose may be Par 9-30 Page 9-19

Page 441Open in PDF

fabricated as described in figure 9-8. Refer to figure 9-10 for minimum bend radii. When a hose assembly is removed, the ends should be tied as shown in figure 9-11, so that the pre­ formed shape will be maintained. Refer to figure 9-12 for minimum bend radii for teflon hose.

(3) All flexible hose installations should be supported at least every 24 inches. Closer supports are preferred. They should be care­ fully routed and securely clamped to avoid abrasion, kinking, or excessive flexing. Ex­ cessive flexing may cause weakening of the hose or loosening at the fittings.

e. O-Ring Seals. An understanding of O - ring seal applications is necessary to determine when replacement should be made. The sim­ plest application is where the O -ring merely serves as a gasket when it is compressed within a recessed area by applying pressure with a packing nut or screw cap. Leakage is not normally acceptable in this type of instal­ lation. In other installations, the O -ring seals depend primarily upon their resiliency to ac­ complish their sealing action. When moving parts are involved, minor seepage may be normal and acceptable. A moist surface found on moving parts of hydraulic units is an indi­ cation the seal is being properly lubricated.

In pneumatic systems, seal lubrication is pro­ vided by the installation of a greaseimpregnated felt wiper ring. When systems are static, seepage past the seals is not nor­ mally acceptable.

f. Storage of replacement seals.

(1) Store O-ring seals where tempera­ ture does not exceed 120° F.

(2) Keep seals packaged to avoid expo­ sure to ambient air and light, particularly sun­ light.

g. During inspection, consider the fol­ lowing to determine whether seal replacement is necessary.

(1) How much fluid is permitted to seep past the seals? In some installations minor seepage is normal. Refer to the manufacturer’s maintenance information.

(2) What effect does the leak have on the operation of the system? Know the sys­ tem.

(3) Does the leak of fluid create a haz­ ard or affect surrounding installations? A check of the system fluid and a knowledge of previous fluid replenishment is helpful.

(4) Will the system function safely without depleting the reservoirs until the next inspection?

h. Do’s and Don’ts that apply to O-ring seals.

(a) Correct all leaks from static seal installations.

(b) Don’t retighten packing gland nuts; retightening will, in most cases, increase rather than decrease the leak.

(c) Never reuse O-ring seals because they tend to swell from exposure to fluids, and become set from being under pressure. They may have minor cuts or abrasions that are not readily discernible by visual inspection.

(d) Avoid using tools that might damage the seal or the sealing surface.

(e) Do not depend upon color-coding.

Coding may vary with manufacturer

(f) Be sure that part number is correct

(g) Retain replacement seals in their package until ready for use. This provides proper identification and protects the seal from damage and contamination.

(h) Assure that the sealing surfaces are clean and free of nicks or scratches before installing seal.

Page 9-20 Par 9-30

Page 442Open in PDF

(i) Protect the seal from any sharp surfaces that it may pass over during installa­ tion. Use an installation bullet or cover the sharp surfaces with tape.

(j) Lubricate the seal so it will slide into place smoothly.

(k) Be sure the seal has not twisted during installation.

i. Hydraulic System Pressure Test.

When a flexible hose has been repaired or overhauled using existing hardware and new hose material, before the hose is installed on the aircraft it is recommended that the hose is tested to at least 1.5 system pressure. A new hose can be operationally checked after it is in­ stalled in the aircraft using system pressure.

j. Hydraulic Components. Hydraulic components such as pumps, actuating cylin­ ders, selector valves, relief valves, etc., should be repaired or adjusted following the airplane and component manufacturer’s instructions.

Inspect hydraulic filter elements at frequent intervals and replace as necessary.

Par 9-30 Page 9-20a (and 9-20b)

Page 443OCROpen in PDF

LOCATE AND SLIT

COVER WITH KNIFE

TO WIRE BRAD

TWIST OFF

COVER WITH PLIERS

1. Place hose in vise and cut to 2. Locate length of hose to be cut desired length using fine tooth off and slit cover with knife to wire hacksaw or cut off wheel. braid. After slitting cover, twist off with pair of pliers. (see note below)

3. Place hose in vise and screw socket on nose counterclockwise.

5. Screw nipple into socket using wrench on hex of nipple and leave .005 inches to .031 inches clearance between nipple hex and socket.

4. *Lubricate inside of hose and nipple threads liberally.

NOTE:

Hose assemblies fabricated per MIL-H-8790 must have the exposed wire braid coated with a special sealant.

NOTE:

Step 2 applies to high pressure hose only.

*CAUTION:

Do not use any petroleum product with hose designed for synthetic fluids, "SKYDROL and /or HYJET product. For a lubricant during assembly use a vegetable soap liquid.

DISASSEMBLE IN REVERSE ORDER FIGURE 9-8. Hose assembly instructions (can be used for low pressure hydraulic fluid, and oil line applications).

Par 9-30 Page 9-21

Page 444Open in PDF

TABLE 9-3. Aircraft hose specifications.

SINGLE WIRE BRAID FABRIC COVERED

MIL.

PART NO.

TUBE SIZE O.D.

HOSE SIZE I.D.

HOSE SIZE O.D.

RECOMM.

OPER.

PRESS.

MIN.

BURST PRESS.

MAX.

PROOF PRESS.

MIN BEND RADIUS MIL-H-8794- 3-L 3/16 1/8 .45 3,000 12,000 6,000 3.00 MIL-H-8794- 4-L 1/4 3/16 .52 3,000 12,000 6,000 3.00 MIL-H-8794- 5-L 5/16 1/4 .58 3,000 10,000 5,000 3.38 MIL-H-8794- 6-L 38 5/16 .67 2,000 9,000 4,500 4.00 MIL-H-8794- 8-L 1/2 13/32 .77 2,000 8,000 4,000 4.63 MIL-H-8794-10-L 5/8 1/2 .92 1,750 7,000 3,500 5.50 MIL-H-8794-12-L 3/4 5/8 1.08 1,750 6,000 3,000 6.50 MIL-H-8794-16-L 1 7/8 1.23 800 3,200 1,600 7.38 MIL-H-8794-20-L 1 1/4 1 1/8 1.50 600 2,500 1,250 9.00 MIL-H-8794-24-L 1 1/2 1 3/8 1.75 500 2,000 1,000 11.00 MIL-H-8794-32-L 2 1 13/16 2.22 350 1,400 700 13.25 MIL-H-8794-40-L 2 1/2 2 3/8 2.88 200 1,000 300 24.00 MIL-H-8794-48-L 3 3 3.56 200 800 300 33.00 Construction: Seamless synthetic rubber Uses: Hose is approved for use in aircraft inner tube reinforced with one fiber braid, hydraulic, pneumatic, coolant, fuel and oil one braid of high tensile steel wire and cov- systems.

ered with an oil resistant rubber impregnated fiber braid. Operating Temperatures:

Sizes-3 through 12: Minus Identification: Hose is identified by specifi- 65 °F. to plus 250 °F.

cation number, size number, quarter year and year, hose manufacturer’s identification. Sizes - 16 through 48: Minus 40 °F. to plus 275 °F.

Note: Maximum temperatures and pressures should not be used simultaneously.

MULTIPLE WIRE BRAID RUBBER COVERED TUBE HOSE HOSE RECOMM. MIN. MIN. MIN.

MIL SIZE SIZE SIZE OPER. BURST PROOF BEND PAR NO. O.D. I.D. O.D. PRESS. PRESS. PRESS. RADIUS MIL-H-8788- 4-L 1/4 7/32 0.63 3,000 16,000 8,000 3.00 MIL-H-8788- 5-L 5/16 9/32 0.70 3,000 14,000 7,000 3.38 MIL-H-8788- 6-L 3/8 11/32 0.77 3,000 14,000 7,000 5.00 MIL-H-8788- 8-L 1/2 7/16 0.86 3,000 14,000 7,000 5.75 MIL-H-8788-10-L 5/8 9/16 1.03 3,000 12,000 6,000 6.50 MIL-H-8788-12-L 3/4 11/16 1.22 3,000 12,000 6,000 7.75 MIL-H-8788-16-L 1 7/8 1.50 3,000 10,000 5,000 9.63 Hose Construction: Seamless synthetic rubber inner Uses: High pressure hydraulic, pneu­ tube reinforced with one fabric braid, two or more steel matic, coolant, fuel and oil.

wire braids, and covered with a synthetic rubber cover (for gas applications request perforated cover). Operating Temperatures:

Minus 65 °F. to plus 200 °F.

Identification: Hose is identified by specification number, size number, quarter year and year, hose manufacturer’s identification.

Page 9-22 Par 9-30