N1511A
Service difficulty reports · 334
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1511A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1511A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2022012500076Shutoff Valve · leakingAIR RETURN, HYDRAULIC QUANTITY DROPPING DURING FLIGHT. .86 DROPPED TO .72 HYD QTY IN FLIGHT. .96 QTY HYD ON TAXI OUT.(<P>FOUND HYRAULIC LEAK @ RUDDER & ELEVATOR SHUT OFF VALVE (V 101). REMOVED AND REPLACED L EMPENNAGE SHUTOFF VALVE IAW AMM 267-3001 27-23.01. OSDR UIEA2021111502420None · noneRIGHT CENTER BOOST PUMP INOP / ( CENTER TANK FUEL PUMPS, ONE INOPERATIVE, CENTER TANK FUEL USED (NOTIFY DISPATCH) )(<P>TRANSFERRED TO MDDR 156676 IAW MEL 28-22-02A CAT C. PLACARD INSTALLED.</P> / <P>14NOV21 - LP 1429978 - ITEM #8 - CVG - CTR RT FUEL PUMP REQSDR UIEA2021110802363None · noneMANUAL OUTFLOW VALVE TO OPERATE NORMALLY(<P>OUTFLOW VALVE OPS CK C/W IAW AMM 21-31-03, OPS CHK GOOD</P>)SDR UIEA2021110302336None · noneSTATUS MSG CARGO A/C TEMPP CAME ON DURING CRUISE(<P><SPAN>PERFORMED FIM 21-287 FT 809 NO PRESSENT STATUS MSG AT THIS TIME OPERATIONAL TEST OK PER FIM 21-28 FT 809</SPAN></P>)SDR UIEA2021110302335None · noneFWD EQUIP EXHAUST FAN STAUS MSG ( FORWARD EQUIPMENT COOLING EXHAUST FAN, ONE SUPPLY FAN INSTALLATION, -200/-300 )(<P>AIRCRAFT RELEASED ON MEL 21-58-04-02-01, CAT C. MDDR #156093.</P> / <P>04NOV21 - LP 1596338 - ITEM# 3 - STL - PERFORMED OPS CHECK PER AMM 21-58SDR UIEA2021110302334Relay · noneSTATUS MSG FWD EQ EXH FAN(<P>PERFORMED T/S IAW FIM 21-58 FAULT TREE 905. FOUND RELAY K345 AT FAULT. REMOVED AND REPLACED RELAY IAW SWPM 20-81-22. OPS CK GOOD. MSG CLEARED. OK FOR SERVICE.</P>)SDR UIEA2021110102315None · noneFWD EQ EXH FAN STATUS MESSAGE WHILE IN FLIGHT.(<P><SPAN>CYCLED BREAKER PER AMM 21-58-06. MSG CLEARED. A/C OK AT THIS TIME.</SPAN></P>)SDR UIEA2021110102322None · noneFWD EQ EXH FAN STATUS MESSAGE IN FLIGHT(<P>CYCLED FWD EXHAUST FAN CIRCUIT BREAKER, PER AMM 21-58-06. STATUS CLEARED AT THIS TIME.</P>)SDR UIEA2021102602288Sensor · noneR PACK AUTO FUNCTION INOP/INTERMITTENT.(<P>TRANSFERRED TO MDDR # 155732, MEL 21-51-03-01. CAT C. DUE ON 05NOV21. MCC: 0928Z D.L.</P> / <P>29OCT21 - LP 1394801 - ITEM# 7 - AFW - PERFORMED B767 FIM 21-51 FT. 870. FOUND COMPRESSOR SENSOR FAULT LIGHT ON. REMOVED &SDR UIEA2021102602285None · noneINTERMITTENT " R PACK TEMP" EICAS MESSAGE DURING ARRIVAL WITH "INOP" LIGHT IN PACK RESET SWITCH.(<P>TROUBLESHOT PER FIM 21-51 FAULT TREE 803. VERIFIED NO MESSAGE ON ECS PAGE. PERFORMED BITE ON RIGHT PACK TEMP CONTROLLER IAW B767 AMM 21-51-00-700-805-006. NO FASDR UIEA2021102202271None · nonePOSSIBLE FOD INGESTION NBR 2 ENGINE.(<P>PERFORMED A VISUAL INSPECTION OF THE INLET APU IAW AMM 72-00-00-211-239-N00. NO EVIDENCE OF ANY INGESTION OF FOD.</P>)SDR UIEA2021101602242None · noneAFT EQ EXH FAN 1 STATUS MESSAGE DISPLAYED PRIOR TO PUSH(<P>MOVED TO DMI #155236 OPERATE PER MEL 21-58-05 CAT C</P> / <P>20OCT21 - LP 1395573 - ITEM #3 - TPA - REMOVED & REPLACED #1 AFT EXHAUST FAN IAW AMM 21-58-41. OPS CHECK GOOD. PLACARDS REMOVED. THIS CLEARSSDR UIEA2021100602196None · noneRT AFT FUEL PUMP LOW PRESSURE EICAS WITH SWITCH DEPRESSED. REF DMI 154604 L/P 1407456 RIGHT AFT FUEL PUMP LOW PRESSURE.(<P>TRANSFERRED TO MDDR 154604 IAW MEL 28-22-01, CAT 'C', DUE 15OCT21. PLACARD INSTALLED.</P> / <P>12OCT21, LP 1407456, ITEM M18. REMOVED ANDSDR UIEA2021100402174Card · noneFWD EQ EXH FAN STATUS DISPLAYED AFTER BLOCK OUT.(<P>REMOVED AND REPLACED ECS FAN CONTROL CARD (M990) USING FIM 21-58 FAULT TREE 905 BLOCK 41 AND AMM 21-58-24-404-010. PREFORMED EQUIPMENT COOLING SYSTEM OPERATION TEST IAW B767 AMM 21-58-00-710-806-015. OPS CHESDR UIEA2021100102153Control Card · fault messageAFT EQ EXH FAN 1 STATUS MESSAGE TRANSFERRED TO MDDR# 154433 IAW MEL 21-58-05. DUE DATE: 11OCT21, CAT C.LP 1407448, ITEM M7: T/S IAW FIM 21-26 FAULT TREE 805. REMOVED AND REPLACED AFT EQUIP/LAV/GALLEY VENT FAN 1 (PN 4101487, IAW AMM 21-26-01. OPS CHECK GOOD. MSDR UIEA2021100402183Valve · failedFW EQUIP VLV EICAS MESSAGE AFTER START. REMOVED AND REPLACED MANIFOLD INTERCONNECT VALVE IAW AMM 21-58-00. OPS CHECK GOOD AND LEAK CHECK GOODSDR UIEA2021100402184Oil Cap · unsecureAPU LOW OIL QTY STATUS MSG ( AUXILIARY POWER UNIT (APU), ER OPERATIONS NOT ALLOWED (NOTIFY DISPATCH) R60 ) TRANSFERRED TO MDDR 154385 IAW MEL 49-11-01A, CAT 'C' .LP 1372392: FOUND APU OIL CAP NOT SECURED, SERVICED APU OIL TO FULL @ APU HOURS: 2616.5 AND RESECUSDR UIEA2021092702138Circuit Card · warning messageSTATUS MESSAGE. AFT EQ EXH FAN 2(<P>REMOVED AND REPLACED #1 AFT EXH FAN CIRCUIT CARD M861 IAW AMM 21-58-24. OPS CHECK GOOD. FOUND #1 FAN ALSO NOT WORKING DURING T/S. FAN REPLACED SEE ABOVE. P/N OFF: 4101487, S/N OFF: 0375</P>)SDR UIEA2021092402109Fan · inoperativeFWD EQUIPMENT EXHAUST FAN INOP(<P>TRANSFER TO MDDR 153992 IAW MEL 21-58-04-02-01. CAT "C", DUE 03OCT21. MCC NOTIFIED. 27 SEP 21 - LP 1238699 ITEM 3 - CVG - R/R #1 AFT EXH FAN IAW AMM 21-26-01. R/R CARD M861 IAW AMM 21-58-24. OPS CHECK GOOD. FOUND #1 FAN ALSO NSDR UIEA2021092002058Apu · false indicationAPU DOOR STATUS MSG(<P><SPAN>PERFORMED FIM 49-11 FAULT TREE 959, APU STARTING PROBLEMS. NO DEFECTS FOUND. PERFORMED APU BITE PROCEDURE IAW FIM 49-11 FAULT TREE 958. NO FAULTS FOUND AT THIS TIME. STARTED AND SHUTDOWN APU MULTIPLE TIMES IAW B767 AMM 49-11-00. OSDR UIEA2021091702042Sensor · inoperativeR/H ENGINE HPSOV INOP ( HIGH PRESSURE SHUTOFF VALVE (HPSOV) SYSTEMS / ALL EXCEPT CF6-80C2 )(<P>TRANSFERRED TO MDDR 153619 MEL 36-11-02-01 CAT C DUE DATE 26SEP21. PLACARD INSTALLED. REF LOGPAGE 1207824 #4 CVG 22 SEP 21 AND LOGPAGE 1207825 #9 CVG22SEP21</P> / <SDR UIEA2021091602030Control Card · inoperativeAFT EQ EXH FAN 1 INOP. TRANSFER TO MDDR 153546(<P>PER FIM 21-26 FT 805 FOUND R ECS FAN CONTROL CARD TO BE AT FAULT. MDDR REMAINS OPEN # 153546 <SPAN>MEL 21-58-05 CAT C</SPAN></P> / <P>20SEP21 - LP 1207811 - ITEM 5 - CVG - REMOVED AND REPLACED M862 CIRCUIT CARDSDR UIEA2021091502027Warning Message · illuminatedAFTER TAKEOFF PASSING 6000FT THE R AFT FUEL PUMP EICAS DISPLAYED WITH ASSOCIATED PRESS SW LIGHT.R/R R/H AFT FUEL PRESS SW IAW AMM 28-42-01 NO HELP. TRANSFERRED TO DMI 153571 MEL 28-22-01 CAT C DUE DATE 25 SEP21 P/N OFF ASP4560 S/N OFF 1715 </P> / <P>20SEP21 -SDR UIEA2021091402020Module · warning lightAFTER ENG. START AND DURING LOW POWER SETTINGS, THE RIGHT ENG BLEED VALVE LIGHT ILLUMINATES INTERMITTENTLY WITH ASSOCIATED EICAS THEN EXTINGUISHES A FEW SECONDS LATER.(<P>TRANSFERRED TO MDDR 153490 PER DDG 36-11-02-01 CAT C DUE 24SEP21. PLACARDS INSTALLED.</P>SDR UIEA2021090601957Relay · failedR AFT FUEL PUMP EICAS MESSAGE. RAN QRH PROCEDURE.(<P>PLACED R AFT FUEL PUMP ON MEL 28-22-01, EXP 9/15/21, MDDR 153033. MX ACTION C/W.</P> / <P>REMOVED AND REPLACED RELAY K189 IAW SWPM 20-81-13 - RESET RELAY K 10702 - ALL OPS CHECKS GOOD. THIS CLEARS MDDR 15303SDR UIEA2021090761958Controller · faultedCABIN ALT AUTO 2 MSG. TRANSFERRED TO MDDR 153020, MEL 21-31-01A, CAT C, DUE 14 SEP 21. T/S PER B767 FIM 21-31 FT 810 - PRESSURE CONTROLLER FAULTED. REPLACED PRESSURE CONTROLLER IAW AMM 21-31-02 - OPS CHECKS GOOD. THIS CLEARS MDDR 153020. PLACARDS REMOVED. MCSDR UIEA2021082001831Cdu · faultedPRIOR TO BLOCK OUT, ELECTRICAL SMOKE WAS SMELLED AND 2 CBS POPPED. FMC CDU AND IND LIGHT.(<P><SPAN>REMOVED AND REPLACED FMC CDU IAW AMM 34-61-02. OPS CHECK NORMAL.</SPAN></P>)SDR UIEA2021080901748Warning Message · false activationAFT EQ EXH FAN 1 STATUS MESSAGE(<P>TRANSFERRED TO MDDR # 151553 PER MEL 21-58-05. CAT C. DUE 19AUG21. MCC NOTIFIED, PLACARDS INSTALLED. T.I.: STR 0509Z.</P> / <P>CVG MX, 09AUG, LP 1391199, ITEM M6: PERFORMED FIM 21-26 FT 805 TO STEP 40, NO MSG DISPLAYED. SYSTESDR UIEA2021080501705Fault Message · false indicationAPU FAULT MSG. ON TAXI IN(<P>PERF. APU BITE IAW FIM 49-11 F/T 958 NO FAULTS NOTED. PERF FIM 49-11 F/T 959 NO DEFECTS NOTED. APU IS SATISFACTORY. PERF APU OPS CHECK IAW 49-11-00. NO DEFECTS NOTED. PLACED WIDE PNEUMATIC & ELECTRICAL LOAD, APU OPERATED NORMAL.</PSDR UIEA2021073001657Shutoff Valve · faultedNO RT BLEED PRESSURE AT IDLE THRUST, NORMAL FOR TAXI. ON CLIMB, LEFT DUCT 40 PSI, RT 20+/- 5 PSI.SLOWLY BECAME NORMAL DURING CRUISE, ON DESCENT RT DUCT PSI WAS HALF OF LEFT PSI. ( HIGH PRESSURE SHUTOFF VALVE (HPSOV)(<P>TRANSFER TO MDDR 151023 IAW MEL 36-11-02-SDR UIEA2021071401546Warning Message · false activationFWD CGO BACKUP EICAS ILLUMINATED ON DEPARTURE.(<P>PERFORMED FIM 21-61 FT 803, NO FAULTS FOUND, ERASED MSG, OK FOR SERVICE.</P>)SDR UIEA2021070101457Start Valve · faultedRH ENG START VALVE INOP ( ENGINE START VALVES, -200/-300 )(<P>TRANSFERRED TO MDDR 149489 IAW DDG 80-00-02-01 CAT C DUE 10JUL21</P> / <P>01JUL21 - LP1396438 - ITEM#1 - TPA - REMOVED AND REPLACED RT ENG START VALVE IAW AMM 80-11-02. OPS TEST GOOD IAW AMM 80-11-0SDR UIEA2021070101456Starter · failedR ENG EICAS R ENG STARTER ENGINE FAILED TO START.(<P>REMOVED AND REPLACED #2 ENGINE STARTER IAW AMM 80-11-01. OPS CHECK GOOD AT THIS TIME. </P>)SDR UIEA2021062901437Apu · no testAPU FAIL (FAULT EICAS)(<P>PERFORMED APU ECU BITE CHECK IAW B767 FIM 49-11 FAULT TREE 958. NO FAULTS NOTED. PERFORMED APU STARTING/OPERATION IAW B767 AMM 49-11-00-802-002. OPS CHECK NORMAL. NO DEFECTS NOTED AT THIS TIME</P>)SDR UIEA2021062801434Warning Message · false activationAFT EQ EXHAUST FAN STATUS MSG.(<P>PERFORMED DIM TASK 21-26 FT 804 BLOCK 1. MSG CLEARED.</P>)SDR UIEA2021062201401Pressure Switch · contaminatedDURING DECENT "R AFT FUEL PUMP" EICAS ILLUMINATED. / PUMP TURNED OFF PER QRH(<P>REF FIM 28-22 FT 819 TO STEP 49 FIG 106, FOUND MOISTURE CONTAMINATION ON FUEL PRESSURE SWITCH. CLEANED CANNON PLUG, RESECURED, COULD NOT DUPLICATE FAULT ON GROUND. RAN FUEL PUMP RSDR UIEA2021061401352Start Valve · failedRT ENGINE START VALVE WON'T OPEN(<P>REMOVED AND REPLACED STARTER CONTROL VALVE IAW AMM 80-11-02. OPS CHECK NORMAL AT THIS TIME.</P>)SDR UIEA2021060101235Warning Message · false activationSTATUS MSG "FWD EQ SUP FAN 1".(<P>PERF FIM 21-58 FT 904, MESSAGE CLEARED, FOUND TRANSITORY. NO FURTHER DEFECTS NOTED.</P>)SDR UIEA2021050301058Warning Message · false activationAPU DOOR STATUS MESSAGE(<P>T/S IAW FIM TASK 49-11 FAULT TREE 959. FOUND SYSTEM TO BE OK, NO FAULTS AT THIS TIME</P>)SDR UIEA2021043001029Warning Message · false indication"OVERSPEED" EICAS WARNING FLASHED ON #2 ENG START. C/W FIM 71-08 FAULT TREE 801, A/C OK FOR RETURN TO SERVICE.SDR UIEA2021042701009Valve · leakingFUEL DRIPPING FROM RIGHT ENG(<P>ISOLATED FUEL LEAKAGE FROM AIR/FOIL HEAT EXCHANGER VALVE AND 2.5 BLEED VALVE ACTUATOR AT A RATE OF 8 TO 10 DROPS PER MIN. AFTER SHUTDOWN, LEAKAGE PERMITTED PER AMM 71-71-00-216-001-N00</P>)SDR UIEA2021042200960Warning Message · false indicationLEFT GEN FIELD ILLUMINATED(<P>CYCLED L/H GEN FIELD & RESET FIELD REF AMM 24-22-02. OPS CHECK GOOD, NO ACTIVE FAULTS NOTED.</P>)SDR UIEA2021042100948Status Message · false activation"APU DOOR" STATUS MESSAGE IN FLIGHT(<P>PERFORMED FIM TEST 49-11 FAULT TREE 959 NO FAULTS NOTED. OPS CK GOOD<BR /></P>)SDR UIEA2021040200785Lamp · inoperativeLEFT AOA OVERHEAD LAMP INOP / ( ANGLE OF ATTACK SENSOR HEATER SYSTEMS (NOTIFY DISPATCH) )(<P>TRANSFERED TO MDDR# 144693 UNDER MEL 30-32-01 CAT C. PLACARDS INSTALLED</P><P>02 APR 21- LP 1187012 ITEM 5 - RFD - REPLACED MISC ANN PANEL ASSY IAW AMM 31-00-00. OPS SDR UIEA2021032200681Seal · brokenDURING MAINTENANCE VISIT AT MEXICANA MRO, IT WAS FOUND THAT THE COCKPIT CABIN ELT WAS FOUND WITH THE SAFETY SEAL BROKEN.(<P STYLE="MARGIN: 0IN; MARGIN-BOTTOM: .0001PT;"><SPAN>THE COCKPIT CABIN ELT WAS REPLACED / PER AMM 25-63-03-400-802. </SPAN>ON PART P/N 11SDR UIEA2021032200685Strut · crackedDURING THE LAST PHASE OF THE C-CHECK ON ABOVE REFERRED AIRCRAFT, WE HAVE FOUND CRACK DAMAGES ON THE RH STRUT INBD SIDE SKIN PANEL BETWEEN NAC STA 172.00 / NAC STA 182.00. THE CRACK DAMAGES ARE LOCATED AROUND THE ACCESS PANEL 442AL AND ARE COMMON TO THE RUB-STRSDR UIEA2021032200686Skin · corrodedCORROSION DAMAGES WERE FOUND ON THE RH HORIZONTAL STABILIZER UPPER SKIN AT REAR SPAR AND STGR 3, BETWEEN RIB 3 / RIB 15.(<P ><SPAN>CORROSION WAS REMOVED AND / REPAIRED IN ACCORDANCE WITH MEXICANA MRO TRE6755034 REV. A AND TRE6755037 REV. / A, ALSO WITH THE INSSDR UIEA2021032200687Skin · corrodedCORROSION DAMAGES WERE FOUND ON THE RH HORIZONTAL STABILIZER UPPER SKIN BETWEEN RIB 6 / RIB 9 AND OVER THE FRONT SPAR.(<P ><SPAN>CORROSION WAS REPAIRED ON / ACCORDANCE WITH MEXICANA MRO TRE6755036 REV. A AND BOEING SR 3-5023179131</SPAN></P>)SDR UIEA2021032200688Skin · corrodedCORROSION DAMAGES WERE FOUND ON THE LH HORIZONTAL STABILIZER UPPER SKIN, BETWEEN RIB 3 / RIB 13, AT THE REAR SPAR ATTACHMENT HOLES.(<P ><SPAN>CORROSION WAS REMOVED AND / REPAIRED IN ACCORDANCE WITH MEXICANA MRO TRE6755038 AND BOEING SR 3-5021676078.</SPAN></P>SDR UIEA2021022400418Actuator · malfunctionedAPU FAILED TO START. INLET DOOR ACTUATOR C\B POPPED.(<P>TRANSFERRED APU TO MDDR 142875 IAW DDG 49-11-01A, CAT C.</P><P>24 FEB LP 1338863 ITEM 7 IAH - REMOVED AND REPLACED ACTUATOR ASSY PER AMM 49-15-06. OPS CHECK IS NORMAL. THIS CLEARS DMI 142875 PLACARD REMO
Back to N1511A