N1619A
Service difficulty reports · 297
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1619A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1619A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020051801075Knob · looseWX RADAR TILT KNOB OFF 2 DEGREES FROM ACTUAL POS. 0 DEGREES ON KNOB INDICATES -2 DEGREES(<P>FOUND TILT KNOB LOOSE. SECURED AND PERFORMED WX RADAR OPERATIONAL SYSTEM TEST IAW AMM 34-43-00. OPS AND INDICATION NORMAL.</P>)SDR UIEA2020051801074Control Panel · faultyWX RADAR TILT KNOB 2 DEGREES OFF FROM ACTUAL POSITION, KNOB SHOWS 7 ACTUAL IS 5 ETC.(<P>REMOVED AND REPLACED PANEL EFIS CONTROL IAW AMM 34-43-02, OPS TEST OK IAW AMM 34-22-02.</P>)SDR UIEA2020051500993Control Valve · malfunctionedAPU AUTO SHUTDOWN / APU FAULT.(<P>APU DEFERRED IAW MEL 49-11-01A THIS IS A CAT "C" ITEM. APU ECU SHOWS "HIGH OIL TEMP" FAULT MDDR# 128079. TIME 22:49Z INT: JT DUE DATE 17MAY20.</P><P>LP 1140515: REMOVED AND REPLACED OIL TEMP CONTROL VALVE ASSY IAW AMM 49-27-10SDR UIEA2020050800993Ecu · faultedAPU AUTO SHUTDOWN / APU FAULT.(<P>APU DEFERRED IAW MEL 49-11-01A THIS IS A CAT "C" ITEM. APU ECU SHOWS "HIGH OIL TEMP" FAULT MDDR# 128079. TIME 22:49Z INT: JT DUE DATE 17MAY20.</P>)SDR UIEA2020042870847Terminal · brokenRIGHT ENGINE FIRE LOOP 1 INOPERATIVE. REMOVED AND REPLACED THE CARD ASSY FIRE DETECTOR ENGINE 2 LOOP IAW AMM 26-11-01. FAULT COULD NOT BE DUPLICATED. FOUND LOWER AFT FIRE DETECTOR WITH A BROKEN TERMINAL, REPLACED THE TERMINAL AT TS 682 IAW WDM 26-11-21 AND SDR UIEA2020042300809Fire Warning · false activationAPU FIRE LP 1 STATUS MSG AFTER SHUTDOWN(<P>PERFORMED FIRE OVERHEAT TEST IAW AMM 26-11-01. OPS CHECK NORMAL.</P>)SDR UIEA2020042000773Control Valve · faultyRH PACK TEMP EICAS MSG(<P><SPAN>T/S IAW B767 FIM 21-51 FT 844, FOUND TEMP CONTROL VALVE FAULT LIGHT ON PTC BUS. RIGHT TEMP CONTROL VALVE NOT IN STOCK. PLACED ON REQ WITH MCC. SEE LP #1189889 ITEM M8 FOR REPLACEMENT.</SPAN></P><P>LP 1189889 - M8: ITEM TRANSFERRSDR UIEA2020041700760Status Message · false activationCABIN ALT AUTO 1 STATUS MSG.(<P>COMPLIED WITH BITE TEST OF #1 AUTO CABIN PRESS CONTROLLER, TEST PASS, NO FAULTS LATCHED. OK FOR CONTINUED SERVICE I/A/W MM CH 21-31-00.</P>)SDR UIEA2020040600693Rotary Switch · defective(THIRD GRIPE) APU SWITCH EXTENDS BEYOND START, THEN RETURNS TO START VICE ON POSITION. NEEDS ADJUSTMENT. APU OPERATES 4.0.(<P>TRANSFERRED TO MDDR 126667 IAW DDG 49-11-01A, CAT C, DUE DATE 14APR2020.</P><P>LOG PAGE 1150016 ITEM 2: REMOVED AND REPLACED APU ROTARSDR UIEA2020040600686Switch · looseAPU SWITCH LOOSE, APU OPERATES NORMALLY, SWITCH JUST NEEDS ADJUSTMENT.(<P>ADJUSTED APU SWITCH IAW AMM 49-61-00. OPS TEST OK.</P>)SDR UIEA2020040600704Switch · malfunctionedAPU SWITCH STICKS IN START POSITION(<P>CHECKED APU SWITCH FOUND TO BE IN NORMAL OPERATION IAW AMM 49-61-00. NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)SDR UIEA2020033100578Warning System · false activation"FWD EQPT VAL" EICAS MSG AFTER ENGINE START. COMPLIED WITH QRH.(<P>PERFORMED T/S PER FIM 21-58 FT 939. NO FAULTS NOTED. SYSTEM OPS CHECK NORMAL.</P>)SDR UIEA2020033000565Controller · malfunctioned"LEFT HPSOV" STATUS MESSAGE(<P>TRANSFERRED TO MDDR 126380 PER MEL 36-11-02-01, CAT 'C'.</P><P>REF LOG PAGE 1226389 ITEM M4: REMOVED AND REPLACED #1 ENGINE VALVE HIGH PRESSURE SHUTOFF IAW AMM 36-11-02. OPS TEST AND LEAK CHECK OK. P/N OFF 802170-12, S/N OFF 9406SDR UIEA2020033000567Connector · looseOIL QTY IND READING ZERO AND NO L OIL PRESSURE LIGHT ILLUMINATED.(<P>FOUND A CANON PLUG ON THE LEFT ENGINE LOOSE. TIGHTENED THE CONNECTOR IAW SWPM 20-63-00, OPS TEST GOOD. OIL QTY AND PRESSURE INDICATION WERE NORMAL. CANON PLUG TIGHTENED WAS D4208P. IAW AMM 79SDR UIEA2020033000581Warning System · false activationLH ENG HPSOV EICAS MSG AFTER LANDING MESSAGE CLEARED PRIOR TO BLOCK IN.(<P>PERFORMED BITE CHECK OF THE AIR SUPPLY MODULE IAW B767 FIM 36-20 FT 804. NO FAULTS NOTED AT THIS TIME.</P>)SDR UIEA2020031900492Tru · malfunctionedAPU TRU INOP.(<P>TRANSFERRED TO MEL NO. 24-32-01B, MDDR 125961, CAT 'D'.</P><P>LP 1167868: REMOVED & REPLACED APU START TRANSFOMER RECTIFIER UNIT IAW AMM 24-32-04. OPS CHECK GOOD. THIS CLEARS MDDR 125961.<BR /></P>)SDR UIEA202002210282Status Message · false activationUPON SHUTDOWN THE FOLLOWING STATUS MESSAGE DISPLAYED: CABIN ALT AUTO 2.(<P>PERFORM BIT ON CABIN PRESSURIZATION CONTROLLER AND NO FAULT FOUND, AND ERASED MESSAGE IAW 21-31-TASK 802.</P>)SDR UIEA2020021750256Exhaust Fan · failedFWD EQUIPMENT EXHAUST FAN EICAS MESSAGE DISPLAYED AFTER FAULTY GPU POWER CART FAILURE.(<P>DEFERRED FORWARD EQUIPMENT COOLING EXHAUST FAN PER MEL 21-58-04-02-01, CAT "C", DUE ON 25FEB2020 AS PER MDDR 124720.</P><P>LP 1191221 - ITEM M1: REMOVED AND REPLACED FWD SDR UIEA2020021700267Unknown · odor"WET SOCK" POLYMERIZED OIL SMELL WHEN TAKEOFF THRUST IS SELECTED ON DEPARTURE (<P>INSPECTED PACK BAYS AND ENGINES FOR OIL LEAKS - FOUND NONE. REFERENCE AMM 21-51-02-206-020. RAN PACKS - OBSERVED NO POLYMERIZED OIL SMELL.</P>)SDR UIEA2020021000223Valve · inoperativeAFT COMPARTMENT TRIM AIR VALVE INOP / (ZONE TRIM AIR MODULATING VALVES (ALL CARGO CONFIGURATION))(<P>TRANSFER TO MDDR #124467, REF MEL 21-61-04-02, CAT 'C', DUE 19FEB20. MX ACTION COMPLIED WITH.</P><P>LP 1183163, ITEM M11: REMOVED AND REPLACED AFT ZONE TEMP TRSDR UIEA2020012750123Exciter · failedNR 2 ENG RISE, NO LIGHT OFF ON FIRST HALF. IGNITION SET TO BOTH AND ENGINE STARTED NORMALLY ON SECOND ATTEMPT. PERFORMED AMM 74-00-00-705-012 AUDIBLE TEST. FAILED ON THE NR 1 POSITION. REMOVED AND REPLACED THE NR 1 IGNITION, NR 2 ENGINE EXCITER BOX IAW SDR UIEA2020012740122Isolation Valve · failedNO RIGHT DUCT PRESSURE INDICATION AFTER SELECTION. REMOVED AND REPLACED THE RIGHT ISOLATION VALVE ASSY IAW AMM TASK 36-11-04-004-001, & TASK 36-11-04-404-013, OPS & LEAK CHECKED GOOD. A/C RELEASED FOR SERVICE.SDR UIEA2020012180089Connector · dirtyAFTER LANDING R ISLN VALVE CAUTION MSG CAME ON. CLEANED CONNECTOR FWD RT ISLN VALVE AND OPS CHK NORMAL, MSG CLEARED, REF AMM 36-11-04-214.SDR UIEA2020011600070Warning System · false activationEICAS R BLEED ISLN VALVE. C/W SUPPLY SYS BITE TEST PER AMM 36-23-00. PERFORMED BITE TEST ON AIR SUPPLY CENTER SYS PER AMM 36-23-00. NO CURRENT FAULTS NOTED. A/C OK FOR SERVICE.SDR UIEA2019121766088Rectifier · failedAPU FAILED TO START AFTER 2 ATTEMPTS. PERFORMED FIM TASK 49-61-00 AND FOUND APU ECU AT FAULT. REMOVED AND REPLACED ECU IAW AMM 49-61-00. OPS CHECKED NORMAL. PERFORMED FIM TASK 49-61-00. FOUND APU STARTER T/R AT FAULT, REMOVED AND REPLACED IAW AMM 49-61-02. SDR UIEA2019121326063Blade · nicked#2 ENGINE #14 C1 FAN BLADE HAS A NICK IN THE TIP AREA.(<P>BLENDED NICK IN TIP AREA ON #2 ENG #14 C 1 FAN BLADE IAW AMM 72-31-02-308-003. REMOVED APPROXIMATELY .030", WITHIN LIMITS.</P><P><BR DATA-MCE-BOGUS="1" /></P><P>(NOTE: LP 1075824 - M6: DMI 121960 OPENEDSDR UIEA2019121326062Apu · faulted"APU FAULT" EICAS MSG ON 1ST ATTEMPT, SECOND ATTEMPT SUCCESSFUL.(<P>PERFORMED APU BITE PROCEDURE AND FOUND NO FAULTS ON THE ECU IAW B767 FIM 49-11 FT 987. OPS CHECK GOOD ON THE APU, NO FURTHER DEFECTS NOTED AT THIS TIME.</P>)SDR UIEA2019102805801Gasket · failedAPU INOPERATIVE, NO DUCT PRESSURE. PERFORMED IGU PUSH PULL TEST OF APU IAW FIM 49-11 FAULT TREE 975 AND FOUND LESS THAN 2 PDS FORCE REQUIRED. ALSO, REMOVED AND REPLACED FLOW SENSE VALVE GASKET IAW AMM 49-53-08 AND SURGE CONTROL VALVE AFT RUBBER DUCT IAW AMMSDR UIEA2019102985802Status Message · false activationAFT EQ EXH FAN 2 STATUS MSG. (<P>TRANSFERRED TO MDDR #119722 IAW MEL 21-58-05, CAT 'C'. PLACARDS INSTALLED, NO OTHER DEFECTS NOTED. </P><P>LP 1100764 - M10: PERFORMED FIM 21-26 FT 808. ERASED MSG PER FIM 31-41-00, OPS CHECK NORMAL. PERFORMED INSPECTION OF BOTHSDR UIEA2019102325782Apu · unknownAPU FAILED TO START ON TAXI IN. (<P>PERFORMED TWO SUCCESSFUL APU STARTS IN A ROW WITH NO DEFECTS NOTED PER AMM 49-00-00, OPS NORMAL. </P>)SDR UIEA2019102325781Latch · broken#2 ENGINE OIL ACCESS PANEL UPPER LATCH BROKEN. (<P>TRANSFERRED TO NON-MEL MDDR 119475 IAW GMM 3.24.2, DUE 31-OCT-2019. </P><P>LP 1113028 - M8: REMOVED AND REPLACED #2 ENGINE OIL ACCESS PANEL, UPPER LATCH IAW AMM 71-11-08. OPS CHECK GOOD AT THIS TIME. THIS CLEASDR UIEA2019100905682Light · unknownLEFT ENG VALVE LIGHT DID NOT CYCLE ON AND OFF DURING ENGINE START. C/W OPERATIONAL TEST OF LEFT ENGINE START VALVE LIGHT SEVERAL TIMES IAW AMM 80-11-00, COMES ON AND OFF AS REQUIRED.SDR UIEA2019100805675Nozzle · obstructedFIRE NOZZLE BLOCKED IN AFT CARGO AT STATION 1150.(<P>REMOVED OBSTRUCTION FROM NOZZLE AS PER AMM 26-23-00, ALL OTHER NOZZLES OK (CLEAR).<BR /></P>)SDR UIEA2019100325629Sensor · malfunctionedAPU AUTO SHUTDOWN WITH APU FAULT EICAS MSG. PERFORMED APU BITE CHECK IAW FIM 49-11 FAULT TREE 958. ON LAST THREE STARTS/AUTO SHUTDOWNS, FOUND HIGH OIL TEMP FAULT. STARTED APU TWICE WITH NO FAULTS OR ISSUES, PERFORMED FIM 49-11 FAULT TREE 958. NO CURRENT MINISDR UIEA2019091705519Shutoff Valve · leakingHYD FLUID NOTED ON WING FAIRING ABOVE LEFT MAIN GEAR. REMOVED AND REPLACED HYD VALVE ASSY - SHUTOFF CONTROL IAW AMM 24-25-01. OPS CHECK GOOD, NO LEAKS AT THIS TIME.SDR UIEA2019090905473Warning System · false activationAPU FAULT MESSAGE ON LOWER EICAS. PERFORMED APU CONTROL UNIT BITE TEST IAW AMM 49-61-05 - FAULT NO LONGER PRESENT. PERFORMED APU START IAW AMM 49-11-00 NO FAULTS NOTED. NOTE: PER MCC REQUEST - AN APU COLD SOAK START VERIFICATION DEFERRAL WAS OPENED (MDDR 11752SDR UIEA2019082305271Outflow Valve · inoperativeDURING WINDOW PRESSURE LEAK CHECK, FOUND CABIN OUTFLOW VALVE DC-MAN INOP.(<P>REMOVED AND REPLACED CABIN PRESSURE OUTFLOW VALVE. OPS CHECK NORMAL PER B767 AMM 21-31-03.</P>)SDR UIEA2019082305270Thermocouple · failedDURING ENGINE CHECK, FOUND PIMU MSG EEC CH-A T 29 RNG FAIL. REMOVED AND REPLACED LEFT 2.9 BLEED VALVE THERMOCOUPLE PROBE IAW AMM 75-32-06, OPS CHECK GOOD.SDR UIEA2019082305267Shutoff Valve · inoperativeLEFT FUEL SHUTOFF VALVE INOPERATIVE. REMOVED AND REPLACED FUEL SHUTOFF VALVE ASSY IAW AMM 28-21-02. OPS CHECK AND LEAK CHECK NORMAL, NO LEAKS NOTED AT THIS TIME.SDR UIEA2019082305265Starter · leaking#1 STARTER OIL QTY DRAIN IS LESS THAN 17 OZ. REMOVED AND REPLACED #1 STARTER IAW B767 AMM 80-11-01, OPS CHECK GOOD. </P>)SDR UIEA2019082305264Hinge · damagedLEFT RAM AIR MODULATION DOOR HINGE PIN (INLET), AFT HINGE DAMAGED.(<P>REMOVED AND REPLACED TWO HINGES AND HARDWARE AS NECESSARY. OPS CHECK OK PER B767 AMM 21-53-01.</P><P><BR DATA-MCE-BOGUS="1" /></P><P>FWD HINGE OFF PART (SN: NSN, PN: 213T3109Y16)</P>)SDR UIEA2019081985209Charger · inoperativeAPU BATT CHARGER STATUS MESSAGE. REMOVED AND REPLACED APU BATTERY CHARGER IAW AMM 24-31-05. RAN APU BATT CHARGER TEST, NO FAULTS NOTED. NO MSG PRESENT.SDR UIEA2019081965199Charger · inoperativeDURING DAILY CHECK DISCOVERED APU CHARGER INOPERATIVE. DURING DAILY CHECK DISCOVERED APU BATTERY LOW VOLTAGE. AFTER ONE HOUR OF APU OPERATION, DISCOVERED APU BATTERY CHARGER STATUS MESSAGE. UNABLE TO CLEAR MESSAGE. REMOVED AND REPLACED APU BATTERY CHARGER IASDR UIEA2019081645172Gauge · faultedCABIN ALT DISPLAY INDICATES ERRATIC AT FL 40 ALT. VARIED FROM 7.000 TO 10.000 WITH RATE FULLY PEGGED IN BOTH A CLIMB AND DESCENT. DIFF PRESSURE WAS CONSTANT. FOUND CABIN PRESSURE GAUGE FAULTY, REMOVED AND REPLACED PRESSURE GAUGE IAW REF AMM 21-33-01, OPS CHESDR UIEA2019080964957Warning Message · false activationON TAXI OUT, L CTR FUEL PUMP AND R CTR FUEL PUMP EICAS MSG WITH 2.2 IN CENTER TANK. ASSOCIATED FUEL CONFIG WITH PUMPS OFF. BOTH PUMPS OPS CHECKED GOOD DURING FUNCTIONAL CHECK. OPS CHECK IAW AMM 28-22-00.SDR UIEA2019072904885Unknown · malfunctionedLEGITIMATE RADAR RETURNS INTERMITTENTLY DISPLAYED WITH GCS ON, OPS OK WITH GCS OFF. (<P>PERFORMED OPERATIONAL TEST OF WEATHER RADAR SYSTEM REF AMM 34-43-02-715-001-001. OPS CHECKED NORMAL AT THIS TIME. </P>)SDR UIEA2019071504761Control Panel · malfunctionedMAIN CARGO FIRE LOOP B WONT EXTINGUISH. (<P>TRANSFER TO MDDR # 114806 IAW DDG 26-16-02-01. PLACARD INSTALLED.</P><P>LP 1089248 - ITEM 1: REMOVED AND REPLACED CARGO FIRE CONTROL PANEL IAW AMM 26-22-03. OPS CHECKED GOOD IAW AMM 26-11-01. THIS CLEARS DMI 114806. SDR UIEA2019071004732Oxygen Mask · inoperativeRT SUPERNUMERY SEAT O-2 MASK INOP.(<P>TRANSFERRED TO MDDR #114438</P><P><SPAN>REMOVED AND REPLACED RIGHT SUPERNUMERY OXYGEN MASK BOX IAW AMM 35-11-51</SPAN><BR DATA-MCE-BOGUS="1" /></P>)SDR UIEA2019062194529Wire · disconnectedRT ENG FIRE LOOP 1 STATUS MESSAGE. T/S IAW FIM 26-11 FT 804, FOUND WIRE AT FIRE LOOP TERMINAL DISCONNECTED. INSTALLED NEW TERMINAL IAW SWPM 20-30-11. PERFORMED FIRE LOOP TEST IAW AMM 26-11-00, SYSTEM TEST NORMAL.SDR UIEA2019061704509Status Message · false activationSTATUS MSG AFT EQ EXH FAN 2. PERFORMED SYSTEM TEST OF THE EQUIPMENT COOLING SYSTEM NO FAULTS FOUND AFT EQUIPMENT EXHAUST FAN 2 APPEARS TO OPERATE NORMAL IAW AMM 21-58-00</P>)
Back to N1619A