N342NW
Service difficulty reports · 219
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N342NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N342NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016111008532Box Beam · crackedLH SIDEBOX BEAM AT LEVEL OF FR43 CRACK WAS FOUND IN FR43 FLANGE AND ATYPICAL CRACK FOUND IN FR43 WEB. REPAIR PER ERA 550228-14SDR DALA2016102007444Doubler · corrodedCORROSION FR 69 TO FR 70 AND BTW STR 32 TO STR 31 ON EXTERNAL SKIN OUT FLOW VALVE AREA AT LOWER FUSELAGE. REPLACED INTERNAL DOUBLER LOCATED OF FRAME 69 TO FRAME 70 AND BETWEEN STRINGER 31R TO STRINGER 32R, OUT FLOW VALVE AREA AT LOWER FUSELAGE AS PER SRM 51-SDR DALA2014122806756Power Supply · no testDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT POWER SUPPLY UNIT 11WL FAILED BITE TEST. REPLACED THE EPSU AND FUNCTIONAL CHECKED NORMAL.SDR DALA2014122706746Skin · dentedDURING INSPECTION, FOUND DENT IN THE FUSELAGE SKIN ONE FOOT AFT OF THE L1 DOOR AND ONE FOOT BELOW FRAME. REPAIRED IAW ER/A 532320-14, REV A.SDR DALA2014122706745Skin · dentedDURING INSPECTION, FOUND FUSELAGE SKIN DENTED 2-4 INCHES AFT OF FRAME 16, BETWEEN STRINGERS 29 & 30L. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-11, FIG 105. REPAIRED IAW ER/A 531227-14, REV-ORIGINAL.SDR DALA2014122506734Skin · corrodedDURING INSPECTION, FOUND CORROSION AT UNDERFLOOR OVERWING FASTENER BETWEEN FRAMES 40-42 LT SIDE AND FLOOR SEAT TRACK Y1292-Y1732. ACCOMPLISHED ER/A 520761-14.SDR DALA2014122506732Skin · dentedDURING INSPECTION, FOUND UPPER FUSELAGE SKIN DENTED. STARTING AT FRAME 13, GOING 1.9" FWD, 3.5" LONG, 4.5" FROM RT LAP SEAM EDGE. REPAIRED IAW ER/A 520763-14, REV ORIGINAL.SDR DALA2014122406699Stringer · corrodedDURING INSPECTION, FOUND STRINGER 42L, FRAME 63 CORRODED. REMOVED CORROSION IAW SRM 51-73-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-13. REPLACED THE STRINGER IAW SRM 51-42-11.SDR DALA2014122506743Angle · crackedDURING INSPECTION, FOUND RT AFT EMERGENCY EXIT HATCH, LT ANGLE SEGMENT CRACKED. REPLACED THE ANGLE SEGMENT IAW SRM 51-42-11 AND DWG D52279040.SDR DALA2014122506742Angle · crackedDURING INSPECTION, FOUND LT FWD EMERGENCY EXIT HATCH, RT ANGLE SEGMENT CRACKED. REPLACED THE ANGLE SEGMENT IAW SRM 51-42-11 AND DWG D52279040.SDR DALA2014122506741Angle · crackedDURING INSPECTION, FOUND LT AFT EMERGENCY EXIT HATCH, RT ANGLE SEGMENT CRACKED. REPLACED THE ANGLE SEGMENT IAW SRM 51-42-11 AND DWG D52279040.SDR DALA2014122506740Angle · crackedDURING INSPECTION, FOUND RT FWD EMERGENGY EXIT HATCH, RT ANGLE SEGMENT CRACKED. REPLACED THE ANGLE SEGMENT IAW SRM 51-42-11 AND DWG D52279040.SDR DALA2014122506739Structure · chafedDURING INSPECTION, FOUND LT NR 1 SLAT LOWER T/E ADJACENT TO TRACK TWO, CHAFED. REMOVED DAMAGE IAW SRM 51-73-00 AND ER/A 494603-14MA .SDR DALA2014122506738Structure · chafedDURING INSPECTION, FOUND LT NR 1 SLAT T/E ADJACENT TO TRACK ONE, CHAFED. REMOVED THE DAMAGE IAW SRM 51-73-00 AND ER/A 494603-14MA.SDR DALA2014122506737Angle · crackedDURING INSPECTION, FOUND RT FWD EMERGENCY EXIT HATCH, LT ANGLE SEGMENT CRACKED. REPLACED THE ANGLE SEGMENT IAW SRM 51-42-11 AND DWG D52279040.SDR DALA2014122506736Angle · crackedDURING INSPECTION, FOUND LT AFT EMERGENCY EXIT HATCH, LT ANGLE SEGMENT CRACKED. REPLACED LT ANGLE SEGMENT IAW SRM 51-42-11 AND DWG D52279040.SDR DALA2014121706566Floor Panel · delaminatedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261DF DELAMINATED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00. REMOVED AND REPLACED THE FLOOR PANEL.SDR DALA2014121406547Floor Support · wrong partWHILE REPLACING THE FLOOR SUPPORT Y +254, FRAMES 12-24 OEM SPLICES FOUND TO BE INCORRECT. CUTOUT FLOOR SUPPORT FROM FRAMES 24- 25.5 IAW SRM 53-00-14, FIG 207. INSTALLED REPAIR IAW SRM 51-42-11 & 53-00-14, FIG 207.SDR DALA2014121006476Floor Panel · damagedDURING INSPECTION, FOUND L1 ENTRY FLOOR PANEL 221FF HAS BROKEN CORNER.SDR DALA2014121006475Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151LF HAS SIDE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006474Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151GF PUNCTURED IN MULTIPLE AREAS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006473Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161AF HAS SIDE DAMAGE HAS WELL AS DELAMINATION. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006472Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 151FF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006471Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 152BF HAS EDGE DAMAGE. FABRICATED A NEW PANEL IAW SRM 53-02-00.SDR DALA2014121006470Floor Panel · puncturedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151DF PUNCTURED IN MULTIPLE AREAS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006469Floor Panel · crackedDURING INSPECTION, FOUND MAIN CABIN FLOOR PANEL 241HF CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006482Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO BAY SLOPING PANEL 152NF PUNCTURED & MULTIPLE DENTS. FABRICATED A NEW PANEL 152NF IAW DWG 3D25-37705.SDR DALA2014121006480Floor Panel · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 262AB HAS SEVERAL CORRODED INSERTS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37498.SDR DALA2014121006479Floor Panel · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261NF HAS SEVERAL CORRODED WASHERS AND INSERTS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37798.SDR DALA2014121006478Floor Panel · delaminatedDURING INSPECTION, FOUND MAIN CABIN FLOOR PANEL 231MF CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37498.SDR DALA2014121006477Floor Panel · delaminatedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261PF HAS CORRODED INSERTS AND DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37498.SDR DALA2014120906444Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO BAY FLOOR PANEL 131AF WITH MULTIPLE DENTS, PUNCTURES & EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW DWG 3D25-37705, REV - G.SDR DALA2014120906443Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CARGO BAY FLOOR PANEL 131BF TOP SKIN LIFTED & DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG 3D25-37705, REV-G.SDR DALA2014120906442Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO BAY FLOOR PANEL 131FF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW DWG 3D25-37705, REV-G.SDR DALA2014120906441Floor Support · corrodedDURING INSPECTION, FOUND FLOOR SUPPORT FRAMES 19-20, Y+254 CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.SDR DALA2014121106508Shackle · wornDURING INSPECTION, FOUND RT PYLON AFT SHACKLE, FWD, FWD FACE HAS WEAR MARK AROUND ALL THREE SLEEVE HOLES. REMOVED DAMAGE IAW SRM 51-73-00. FOUND OUT OF LIMITS IAW ER/A 507720-14MA. INSTALL NEW SHACKLE.SDR DALA2014120506402Girt Bar · delaminatedDURING INSPECTION, FOUND L2 DOOR FWD GIRT BAR FITTING PLATE DELAMINATED. REMOVED DAMAGE IAW SRM 51-73-00. CHECKED DIMENSIONS L= 1.0 ", W= 0.50", D= 0.006". NO ALLOWABLE DAMAGE LIMIT FOUND IN SRM. REPLACED AND INSTALLED ON WC 2500-6602.SDR DALA2014121006484Floor Support · corrodedDURING INSPECTION, FOUND FLOOR SUPPORT BETWEEN FRAMES 68-69, Y125CM, HAS SEVERAL SPOTS OF CORROSION. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15, FIG. 101. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.SDR DALA2014121006481Floor Support · corrodedDURING INSPECTION, FOUND FLOOR SUPPORT BETWEEN FRAMES 65-67, -Y35CM, CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-74-00 AND 53-00-14, FIG 102. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA2014120406388Dummy Rail · corrodedDURING INSPECTION, FOUND DUMMY RAIL FRAMES 20-21, Y-189 CORRODED. REMOVED CORROSION IAW SRM 51-74-00. REPLACED THE DUMMY RAIL IAW TRM 53-21-01.SDR DALA2014120206367Floorbeam · corrodedDURING INSPECTION, FLOORBEAM AT FRAME 68, HAS CORROSION ON THE TOP SURFACE. REMOVED CORROSION IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REPLACED FLOORBEAM IAW SRM 51-42-11 AND SRM 51-44-11.SDR DALA2014120106344Floor Support · corrodedDURING INSPECTION, A FLOOR SUPPORT BETWEEN FRAMES 66-68, Y1292 WAS FOUND CORRODED. BLENDED THE AREA IAW SRM 51-74-00 AND FOUND IT TO BE OUT OF LIMITS IAW TRM 53-41-15. INSTALLED A NEW FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA2014120106343Floor Support · corrodedDURING INSPECTION, FOUND A FLOOR SUPPORT CORRODED AT FRAME 68. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R THE FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA2014120106342Floor Support · corrodedDURING INSPECTION, MAIN CABIN FLOOR SUPPORT, FRAMES 68-69, -Y1292 CORRODED. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND SRM 51-44-11.SDR DALA2014120106340Floor Support · corrodedDURING INSPECTION, MAIN CABIN FLOOR SUPPORT FRAMES 66-68, -Y1260 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND SRM 51-44-11.SDR DALA2014121106507Fitting · corrodedDURING INSPECTION, FOUND RT FWD DOOR FWD GIRT BAR FITTING AREA HAVE CORROSION. BLENDED CORROSION IAW SRM 53-11-14, FIG 108.SDR DALA2014120206368Attach Angle · corrodedDURING INSPECTION, UPPER INBD ATTACH ANGLE BETWEEN FLOORBEAMS AT FRAME 68 CORRODED. REMOVED CORROSION IAW SRM 51-74-00. REPLACED THE ATTACH ANGLE IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA2014112606263Floor Support · corrodedFLOOR SUPPORT FROM FRAMES 64 -66, -Y765 HAS CORROSION. R & R FLOOR SUPPORT IAW SRM.SDR DALA2014112606262Floor Support · corrodedFLOOR SUPPORT FROM FRAMES 66-70, -Y765 HAS CORROSION. R & R FLOOR SUPPORT IAW SRM.SDR DALA2014112506246Floor Panel · damagedMAIN CABIN FLOOR PANEL 232DF INSERT CORRODED. R & R INSERT.
Back to N342NW