N650AE
Service difficulty reports · 267
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N650AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N650AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2022010400013None · noneE892912 - LH CABIN #3 FLOOR SILL CORRODED. ... RAR LH #3 CABIN FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2022010400012None · noneE892911 - LH CABIN #2 FLOOR SILL CORRODED ... REMOVED AND REPLACED LH CABIN #2 FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2022010400011None · noneE892910 - RH CABIN #2 FLOOR SILL CORRODED ... REMOVED AND REPLACED RH CABIN #2 FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2022010400010None · noneE892909 - RH CABIN #1 FLOOR SILL CORRODED. ... RAR RH CABIN #1 FLOOR SILL IAW EMB1145 SRM 51-40-02SDR HNAA2022010400009None · noneE892893 - CARGO DOOR SILL CORRODED ...REMOVED DRILLED AND INSTALLED SERVICEABLE CARGO DOOR LRW CENTER SILL IAW EMB 145 SRM 51-20-03 AND SRM 51-40-02.SDR HNAA2022010400008None · noneE892891 - FR 68 SHEAR CLIP CRACKED BETWEEN STGRS 06L/07L .... COMPLETED INSTALLATION OF SHEAR CLIPS REPAIR FOR FR 68 BETWEEN STGRS 06L/07L IAW EMB 145 SRM 53-31-04-RE, ITEM #2 AND TABLE 203 AND TABLE 205 AND PIEDMONT EO1-53-21-0367.SDR HNAA2022010400007None · noneE892890 - CARGO FR 68 GOUGED AT NUTPLATE HOLES (6EA) BETWEEN STGRS 01L/08L .... INSTALLED 3 EA DOUBLER REPAIRS FOR FR 68 NUTPLATE REPAIR POSITION #3, #4 AND #6 IAW ETD2021-145-042792 REV. B AND PIEDMONT EO1-53-21-0366.SDR HNAA2022010400006None · noneE892866 - R/H WING RIB 21 IS CRACKED. ... COMPLETED FABRICATION, POSITIONING, AND DRILLING OF REPAIR DOUBLER, FILLER, AND SHIM FOR RH WING RIB 21 REPAIR IAW EMB145 SRM 57-20-07 AND PIEDMONT EO1-57-21-0358SDR HNAA2022010400005None · noneE892865 - L/H WING RIB 21 IS CRACKED ...INSTALLED SERVICEABLE REPAIR DOUBLER, FILLER, AND SHIM ON LH WING RIB 21 IAW EMB145 SRM 57-20-07 AND PIEDMONT EO1-57-21-0357.SDR HNAA2022010400004None · noneE892657 - BAGGAGE DOOR WEBBING IS GOUGED 5 EACH ONE ON PREVIOUS REPAIR ... NO. 4 AND 5 GOUGES FOUND TO BE WITHIN ALLOWABLE LIMITS, MATERIAL REMAINING AFTER BLEND OUT IAW EMB 145 SRM 52-30-01. REPAIRED 1, 2 AND 3 DOUBTERS ON CARGO DOOR INNER WEB IAW ETD2021-145SDR HNAA2022010400003None · noneE892626 - DENT ON BAGGAGE DOOR LOWER FRAME ... UPON FURTHER INVESTIGATION FOUND DENT TO BE ON BAGGAGE DOOR LOWER OUTBD "L" PROFILE. RAR "L" PROFILE ON LOWER BAGGAGE DOOR IAW EMB 145 SRM 51-40-02SDR HNAA2022010400002None · noneE892012 - LH SIDE FUSELAGE SKIN HAS POSSIBLE CRACKS AROUND FASTENERS ON FRAME 79 (1) EA ... REPAIRED LH SIDE FUSELAGE SKIN AROUND FASTENERS ON FRAME 79 (1) EA IAW EMB 145 SRM 53-32-01-RE, ITEM 9, FIG 213 AND PIEDMONT EO1-53-21-0360.SDR HNAA2022010400001None · noneE891811 - LIGHTNING STRIKE ON FUSELAGE SKIN AT FR 26-27 AND STR 17R-16R ... ACCOMPLISHED RIVET REPAIR OF LIGHTNING STRIKE ON FUSELAGE SKIN AT FR 26-27 AND STR 17R-16R IAW EMB 145 SRM 53-00-01 ITEM 2B AND PIEDMONT EO1-53-21-0368.SDR HNAA2022010400000None · noneE891808 - LIGHTNING STRIKE ON FUSELAGE SKIN AT FR 24-25 AND STR 17R-18R ... PERFORMED REPAIR ON FUSELAGE SKIN AT FR 24-25 AND STR 17R-18R. IAW EMB 145 SRM 53-22-01 FIG 204 SHEET 1 AND PIEDMONT EO1-53-21-0369.SDR HNAA2021111700561Warning Message · false indicationON REJECTED T/O EICAS WARNING T/O NO CONFIG APPEARED WITH NO AURAL CALLOUT. T/S PERFORMED FIM TASK 31-51-00-810-804-A BLOCK 1 THROUGH BLOCK 7 R&R RELAY K0212 IAW AMM 20-13-02 OPS CHECK PERFORMED IAW AMM 31-51-00 OPS CHECK GOOD A/C OK FOR SERVICE AT THIS TIME.SDR HNAA2021083100438Pump · failedHYD SYS 1 LOW QTY IN FLT ( HYD SYS 2 REMAIN FULL) R&R NR 1 ENG DRIVEN PUMP IAW EMB 145 AMM 29-10-03. OPS CHECK GOOD NO FURTHER LEAKS DETECTED A/C OK FOR SERVICESDR HNAA2021041400153Eicas · faultyPDIS 650, 31-41, 13APR21 PHL CLOSE, 300 FEET AFTER ROTATION, EICAS DISPLAY FLASHED BRIGHTLY AND WENT BLANK MOMENTARILY FOLLOWED BY AN ELECTRICAL ODOR. R&R'D EICAS DISPLAY UNIT AS REQUIRED PER AMM 34-22-01-400-801-A, OPS CHECK IAW 34-22-00-700-801A GOOD ON GROSDR HNAA2020123100384Unknown · odorAFTER T/O FUMES WERE SMELLED, SIMILAR TO A WET MUSTY SOCK ODOR. GROUND RAN AIRCRAFT ENGINE NR 1 AND NR 2 ALSO OPERATIONS CHECKED AIRCRAFT AIR CONDITION SYSTEM. NO DEFECTS OR ABNORMAL SMELLS FOUND, IN REF TO FIM TASK 21-20-00-810-801-A. A/C OK FOR SERVICE.SDR HNAA2020052300153Warning Message · false activationSPOILER FAIL EICAS MESSAGE DISPLAYED ON TAKE OFF.CW FIM 27-63-00-810-802A STEPS 1-9, DETERMINED TO BE TRANSITORY. R+R SCU IAW 27-63-02 AND 27-63-01 FOR POSITIVE MAIN ACTION . OPS CHECK GOOD. OK FOR SERVICESDR HNAA2020052310153Control Unit · malfunctionedSPOILER FAIL EICAS MESSAGE DISPLAYED ON TAKE OFF. CW FIM 27-63-00-810-802A STEPS 1-9, DETERMINED TO BE TRANSITORY. R & R SCU IAW 27-63-02 AND 27-63-01 FOR POSITIVE MAIN ACTION . OPS CHECK GOOD. OK FOR SERVICE.SDR HNAA2020021200056Unknown · odorPDIS 650 21-01 2289391 11FEB20 PHL CLOSE
CREW NOTICED FUMES DURING TAKE OFF. THEN WENT AWAY. FUMES CAME BACK IN CRUISE FLIGHT AND GOT STRONGER TH
ROUGH DESCENT
FACT 11FEB20 18:43 PHL
EVALUATION FLIGHT REQUIRED. RAN BOTH SDR HNAA2020021100055Unknown · odorOIL FUME SMELL-VERY APPARENT IN COCKPIT- WHEN BOTH PACKS ARE ACTIVATED THROUGHOUT WHOLE FLIGHT. FOUND LOOSE DUCT IN #1 PACK. OPERATED APU AND BOTH ENGINES AFTER TIGHTENING DUCTS WITH BOTH PACKS ON AND FULL HEAT, NO SMELL PRESENT. OK FOR SERVICE AT THIS TIME.SDR HNAA2020020500044Relay · faultedEICAS CT MESS, RUDDER SYS 2 INOP, IN FLT (TAKE-OFF). R+R RUDDER #2 PRESSURE SWITCH IAW AMM 27-23-04. OPS CHECK GOOD OK FOR SERVICE. EICAS MESS, RUDDER SYS 2 INOP, IN FLT. T/S IAW FIM TASK 27-23-00-810-802-A. FOUND RUDDER PRIORITY RELAY K0384 TO AT FAULT. R/R'DSDR HNAA2020020100032Unknown · odorSTRONG FUMY SMELL IN FLT DECK DURING ALL PHASES OF FLIGHT.MORE NOTICEABLE ON GROUND....FIX:PERFORMED HIGH POWER ENGINE RUNS WITH CREW. COULD NOT DUPLICATE ANY SMELLS WHILE ON APU,ENGINES AND WITH BOTH PACKS ON. A/C OK FOR SERVICE AT THIS TIMESDR HNAA2020010600013Computer · inoperativePDIS 650 27-36 2289051 05JAN20 PHL CLOSE
SPS 2 INOP AND SPS ADVANCED DURING REJECTED TAKEOFF
FACT 05JAN20 20:15 PHL
PERFORMED OPS CHECK IAW AMM 27-26-00. DETERMINED FAU
LT ON STALL PROTECTION COMPUTER. R&R SPC COULSDR HNAA2019102800327A/C Pack · odorPDIS 650 21-50 1891911 27OCT19 DCA CLOSE
BURNING RUBBER SMELL NOTICED IN CABIN AND COCKPIT. S
MELL WENT WHEN PACK 1 WAS TURNED OFF.
FACT 27OCT19 02:33 ALB
MX INSP AND DETERMINED SMELL IS ONLY ASSOCIATED WITH PACK 1. OPERSDR HNAA2019102500320Acm · smokeSMOKE FOUND IN CABIN DURING FLIGHT....FIX: R&RD RH ACM, MAINT FOUND FROZEN, IAW AMM 21-51-03. OPS AND LEAK CHECK GOOD.OK FOR SERVICE. NO SMOKE FOUND WITH ENGINES RUNNING. NOTE: CREW REPORTED EMERGENCY, NO EVACUATION, NO EMERGENCY EQUIPMENT USEDSDR HNAA2019051300139Relay · burnedNDIS 650 05-50 0001550 24APR19 RIC CLOSE PITOT NR 3 RELAY K0058 AND BASE VISIBLY BURNT AND DEFORMED RELAY K0057 WAS PHYSICALLY DAMAGED AND SILICONE GASKET WAS STICKING AND NOT RETAINING ORIGINAL FORM 34793 00 SJU FACT 24APR19 10:50 RIC RR RELAY SDR SIMA20190409004Floor Support · dentedDENT ON RH OMEGA BEAM BETWEEN FR. 49-50-C/A-ACCOMPLISHED REPAIR ON RH OMEGA BEAM BETWEEN FR49 AND 50 IAW ERS-EM-5300-3734 AND EMB145 SRM 53-23-10SDR SIMA201904098001Channel · out of limitsSERVICE DOOR CUT-OUT FRAME 22 AFT LOWER CORNER OUT OF LIMITS.-C/A-ACCOMPLISHED SERVICE DOOR CUTOUT FR22 REPAIR IAW ERS-EM-53MR-3728SDR SIMA201904053001Firewall · canningAPU FIREWALL AT RH UPPER CORNER IS OIL CANNING-C/A-REPAIRED APU FIREWALL IAW ERS-EM-49MR-141SDR SIMA201904012Wire · broken#8 EMERGENCY LIGHT STRIP WIRE BROKEN-C/A-REMOVED AND REPLACED # 8 EMERGENCY LIGHT STRIP IAW EMB 145 AMM 33-50-12.SDR SIMA20190306005Crossbeam · corrodedCENTER AISLE CROSSMEMBER AT FRAME 25 IS CORRODED. C/A-COMPLETE:REMOVED AND REPLACED CENTER AISLE CROSSMEMBER AT FRAME 25 IAW SRM 53-22-10, ETN-EM-53-139R4, AND ETN-EM-53-150R2.SDR SIMA20190306004Floor Support · corrodedPREVIOUS REPAIR IS CORRODED ON CENTER OMEGA BEAM BETWEEN FRAMES 24-25. C/A-COMPLETE:REMOVED CORROSION ON PREVIOUS REPAIR ON CENTER OMEGA BEAM BETWEEN FRAMES 24-25 VIA BLENDING IAW SRM 51-10-03.SDR SIMA20180726004Transducer · failedDIVR STL E2 A/I ICE FAIL IN ICING CONDITIONS / EMER DECL. DEFERRED E2 A/I VLV M PROCEDURES C/W. FOUND CMC MSG E2 A/ICE VALVE FAIL, E2 A/ICE LOW PRESS, AND A/ICE OVERPRESS REMOVED AND REPLACED RT A/ICE VALVE IAW AMM 30-21-01 AND REMOVED AND REPLACED TRANSDUCER SDR SIMA2018072318002Controller · malfunctionedON DESENT TO LANDING PASSING THROUGH FL 240, AURAL ALERT CABIN AND CABIN ALT REACHED 11,000 FT. TS PRESN AUTO FAIL MSG PER FIM 21-31-00-810-801-Z. R&R DIGITAL CONTROLLER IAW AMM 21-31-01-000-801-A/21-31-01-400-801-A FNC TASK 21-31-00-700-802-A GOOD.SDR SIMA2018071613004Controller · malfunctionedON DESCENT TO LANDING AUTO MODE PRESS FAIL. TS PRESN AUTO FAIL MSG PER FIM 21-31-00-810-801-Z. REMOVED AND REPLACED DIGITAL CONTROLLER IAW AMM 21-31-01-000-801-A/21-31-01-400-801-A FNC TASK 21-31-00-700-802-A.SDR SIMA20171219003Holder · brokenAFT FA FLASHLIGHT HOLDER BROKEN. R&R AFT FA'S FLASHLIGHT HOLDER BRACKET IAW AMM 33-50-16 OPS CHK GOOD AT THIS TIME LED LIGHT IS ON.SDR SIMA20171011001Rheostat · failedELECTRICAL BURNING ODOR ENROUTE, DESCENT & LANDING, ODOR IN COCKPIT AND NEAR F/A JUMPSEAT. INSPECTED AND FOUND THE CAPTAIN'S FLOODLIGHT RHEOSTAT TO BE AT FAULT. REMOVED AND REPLACED THE INSTRUMENT AND CONTROL PANEL LIGHT PANEL ASSEMBLY IAW AMM 20-13-10 AND OSDR SIMA20170310001Lamp · inoperativeSERVICE DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. R & R THE LAMP IAW AMM 33-50-10-000-801-A, & 33-50-10-400-801-A. OPS CHECKED GOOD.SDR SIMA20170112002Door · unknownMAIN DOOR HARD TO OPEN AND CLOSE. REMOVED BRACKET AND BELLCRANK BOLT IAW AMM 52-18-02 ALL WORK ACCOMPLISHED ON NRWC 650-DFW-03000, 03001, AND 03002. PERFORMED OPERATIONAL CHECK IAW AMM 52-18-00 ON MAIN CABIN DOOR. OPS CHECKED GOOD.SDR SIMA20170106003Flashlight · inoperativeFLIGHT ATTENDANT FORWARD FLASHLIGHT RED CHARGING LIGHT NOT ILLUMINATING. REMOVED AND REPLACED THE FLASHLIGHT IAW AMM 33-50-16 OPS CHECKED GOOD.SDR SIMA20161207005Light · brokenNR 3 FLOOR PROX LIGHT STRIP BROKEN. REMOVED AND REPLACED NR 3 FLOOR PROX LIGHT STRIP IAW AMM 33-50-12. OPS CHECK GOOD.SDR SIMA20161207006Light · brokenLT NR 5 EMERGENCY LIGHT STRIP BROKEN. REMOVED AND REPLACED LT NR 5 EMERGENCY LIGHT STRIP IAW AMM 33-50-12. OPS CHECK GOOD.SDR SIMA20161128011Trunnion · crackedRT AFT UPPER TRUNNION CRACKED. INSTALLED SERVICEABLE RT MLG AFT UPPER TRUNNION IAW ERS-EM-57MR-731.SDR SIMA20161128010Frame · chafedCHAFE ON FR 61 BETWEEN STGRS 4R-5R. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-2442. DOUBLER P/N 145-64146-001.SDR SIMA20161128006Structure · crackedPOSSIBLE CRACK LOCATED APPROX 1" BELOW CARGO DOOR HANDLE CUTOUT. INSTALLED REPAIR DOUBLER, CARGO DOOR IAW ERS-EM-52MR-661.SDR SIMA20161128009Door Sill · corrodedCARGO DOOR ENTRANCE SILL CORRODED. R&R CARGO DOOR SILL IAW SRM 51-40-02.SDR SIMA20161128007Floor Support · corrodedCORROSION IN GALLEY AREA ON RT OMEGA BEAM FRAME 23 AT PREVIOUS REPAIR. INSTALLED DOUBLER AT RT OMEGA BEAM AT FR 23 IAW ERS-EM-53MR-2447.SDR SIMA20161128008Trunnion · crackedWHILE PERFORMING HFEC INSPECTION ON LT MLG AFT UPPER TRUNNION, FOUND TRUNNION TO BE CRACKED. FREQUENCY 400KHZ,ANGLE 130 DEGREES, H-GAIN 63.6,V-GAIN 77.6. USED EASI 6581. INSTALLED SERVICEABLE LT MLG AFT UPPER TRUNNION IAW ERS-EM-57MR-722.