N7882B, cancelled Feb 17, 2025
Service difficulty reports · 191
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7882B' AND deregistration_id = 'N7882B-2025-02-17' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N7882B' AND deregistration_id = 'N7882B-2025-02-17' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024110154472Bulb · inoperativePASSENGER CABIN EMERGENCY LIGHT AT SEAT 9ABC INOP.<[01] R/R 9ABC EMERGENCY LIGHT BULB AND LENS PER AMM 33-51-03SDR SWAA2024110154473Seal · crackedRIGHT HORIZONTAL STRAP FWD UPPER SLIDING SEAL CRACKED.<[01] R&R RH HORIZONTAL FWD UPPER SLIDING SEAL REF. AMM 53-31-31.SDR SWAA2024041875942Slide · dislodgedFWD MAIN L1 DOOR SLIDE CAME OUT OF SLIDE PACK DID NOT DEPLOY<[01] REINSTALLED L1 SLIDE INTO SLIDE COVER AND INSTALLED ON L1 DOOR PER AMM 25-66-01 AND TASK CARD 725-61-06SDR SWAA2023081688787Handle · looseAFT ENTRY DOOR HANDLE (INSIDE) LOOSE<[01] TIGHTENED HANDLE BOLTS TO AFT ENTRY DOOR REF AMM 52-13-11SDR SWAA2023032118608Sign · missingFLIGHT ATTENDANT REPORTS EXIT SIGN AT OVERWING EXIT ON F/O SIDE MISSING<[01] R&R?D RH OVERWING EXIT EMERGENCY EXIT LIGHT ASSY FWD OF DOOR REF AMM 33-51-01. OPS CHECK GOOD.SDR SWAA2023031717888Megaphone · inoperativeMEGAPHONE IN AFT GALLEY INOP.<[01] REPLACED AFT MEGAPHONE REF. AMM 25-64-00. OPS CHECKS GOOD.SDR SWAA2023021603648Panel · crackedRT WING PANEL #621PB HAS HAS A 2' CRACK EMANATING FROM THE FWD I/B FASTENER HOLE.<[01] REMOVED AND REPLACED PNL 621PB REF SRM 51-40-02SDR SWAA2022120979761Battery Pack · inoperativeLEFT AND RIGHT HAND LOWER AFT SLIDE ILLUMINATION LIGHTS DO NOT OPERATE. REMOVED AND REPLACED EMERGENCY EXIT LIGHT BATTERY PACK AND PERFORMED GOOD OPS CHECK IAW AMM 33-51-06-960-805.SDR SWAA2022120976206Gusset · crackedL/W UPPER T/E PANEL LOWER SUPPORT GUSSET CRACKED AT LOWER TRANSVERSE WEB ATTACH POINT ABOVE #1 PYLON AFT TIP. REMOVED AND REPLACED CRACKED L/W UPPER T/E PANEL; LOWER SUPPORT GUSSET AT LOWER TRANSVERSE WEB ATTACH POINT ABOVE #1 PYLON IAW SRM 51-40-02-0G-0.SDR SWAA2022120976213Gusset · crackedR/W UPPER T/E PANEL; LWR T/E GUSSET CRACKED AT LOWER TRANSVERSE WEB ATTACH POINT ABOVE #2 PYLON AFT TIP. REMOVED AND REPLACED CRACKED R/W UPPER T/E PANEL; LWR T/E GUSSET AT LOWER TRANSVERSE WEB ATTACH POINT ABOVE #2 PYLON IAW SRM 51-40-02-0G-0.SDR SWAA2022120975179Stiffener · crackedLEFT HORIZONTAL STAB INSPAR RIB, HSS 129.50; THIRD VERTICAL STIFFENER IS CRACKED. FABRICATED ANGLE, FILLER, 2 SHIMS, LOCATED AND DRILLED ALL REPAIR PARTS IAW SRM 55-10-09-2R-5, REPAIR 5. APPLIED A CHEMICAL CONVERSION COATING AND PRIMER TO REPAIR PARTS IAW SDR SWAA2022120975180Attach Angle · crackedATTACH ANGLE CRACKED AT MID PASSENGER CABIN BS663+27 RBL1. NO ALLOWABLE DAMAGE FOUND ON SRM FOR THIS PART; PART WILL BE REPAIRED BY REPLACEMENT PER SRM 51-40-02-0G-0 STEP 9. REMOVED ANGLE FROM MID PASSENGER CABIN BS-663+27 RBL-1 PER SRM 51-40-02-0G-0. NO ASDR SWAA2022120975181Floor Support · crackedFLOOR SUPPORT CRACKED AT MID PASSENGER CABIN BS540 LBL23. / [01] REMOVED AND INSTALLED NEW PLATE ON FLOOR SUPPORT AT BS540; AS PER SRM 51-40-02 AND DWG. 143A5240.;[02] VERIFIED CORRECTIVE ACTION #1;[03] CORRECTED MEASUREMENT TABLE;[04] VERIFIED MEASUREMENT TABSDR SWAA2022121574286Repair · detachedL/H LOWER COMPOSITE BULKHEAD AT BS663 PREVIOUS REPAIR COMING OFF LBL10 WL151. VALIDATED REPAIR IS TO REPLACE THE PERMANENT SEALANT REPAIR THAT WAS PREVIOUSLY APPLIED AS PART OF REPAIR PER SRM 57-10-10-2R-2 PAR 5.O;[02] REMOVED PREVIOUS REPAIR ON AFT SIDE ANDSDR SWAA2022121374294Skin · crackedCRACK AROUND THE FASTENER ON THE NR 1 SLAT LOWER SURFACE. REMOVED FASTENERS IAW SRM 51-40-02. HFEC INSPECTED SUSPECTED CRACKED HOLES IAW NDTM PART 6 51-00-00 PROCEDURE 16. CRACKS NOTED. HFEC INSPECTED SUSPECTED CRACKED COUNTERSINKS IAW NDTM PART 6 53-30-SDR SWAA2022121374288Skin · crackedCRACK AROUND THE FASTENER ON THE NR 6 SLAT LOWER SURFACE OF THE L/E SLAT NOSE SKIN AT ACTUATOR RIBS. REMOVED FASTENERS IAW SRM 51-40-02. TRIMMED OUT THE DAMAGE IAW SRM 57-42-01-2R-8. FABRICATED REPAIR DOUBLER, FILLER, AND APPLIED CHEMICAL CONVERSION COATSDR SWAA2022121374289Skin · crackedCRACK AROUND THE FASTENER AT THE NR 7 SLAT LOWER SURFACE, AT ACTUATOR RIBS. REMOVED FASTENERS IAW SRM 51-40-02. HFEC INSPECTED OPEN HOLES IAW NDTM PART 6 51-00-00, PROCEDURE 16. CONFIRMED CRACKS WITHIN INSPECTION AREA. HFEC INSPECTED COUNTERSINKS IAW NDTM SDR SWAA2022091974278Valve · noneFUEL IMBALANCE OF APPROX 350 LBS/10 MIN. FROM #2 TANK TO #1 TANK. FUEL FLOW ON #1 ENGINE .1 TO .05 MORE FUEL BURN THAN #2 ENGINE / [01] ADJUSTED CROSSFEED VALVE PER AMM 28-22-21; NO HELP.;[02] REMOVED AND REPLACED CROSSFEED VALVE REF DAVCOR REPAIR STATION 2200SDR SWAA2022042696849Valve · misalignedBASICALLY THE SAME WRITE-UP FROM 4/12/22. ONCE CENTER TANK FUEL WAS ALL USED BEGAN TO SEE RAPID FUEL IMBALANCE; RIGHT SIDE LOW. APROX 560 LBS IMBALANCE WITHIN 45MIN. LEFT (#1) FF HIGHER BY APPROX 50 LBS/HR. FOR DURATION OF FLIGHT. / [01] PERFORMED CROSS FEED VSDR SWAA2022041893490Valve · out of balanceRECURRING FUEL IMBALANCE OF 380 LBS EVERY 30 MIN WAS OBSERVED. NO. 2 FUEL TANK QUANTITY DROPPED BELOW THE NO. 1 FUEL TANK QUANTITY AT THIS RATE. CROSSFED TO CORRECT THE IMBALANCE. CONTROL... ...COLUMN DEFLECTION WAS NOTED DURING THE IMBALANCE. NO 1 ENGINE FUELSDR SWAA2022031782987Seal · out of positionRT HORIZONTAL STAB LOWER AFT SLIDE SEAL IS NOT ENGAGED IN TRACKS / [01] RE-ENGAGED RT HORIZONTAL STAB AFT LOWER SLIDE SEAL INTO TRACKS PER AMM 20-50-11-910-801.;[02] CAL TOOL USED: PER2109;[03] VERIFIED RE-ENGAGED RT HORIZONTAL STAB AFT LOWER SLIDE SEAL INTO TSDR SWAA2022031782210Fuse · inoperativeWHILE PERFORMING BATTERY PACK INSTALLATION TEST ON STA 500C+7.5 WL213 LBL67 L1065 AISLE LIGHT STA500C WL274 LBL30 FAILED TEST. / [01] THE L1065 AISLE LIGHT INOP AT STA500C WL 274 LBL 30;SHOULD BE AT STA 580 WL 274 LBL 30.;[02] COMPLETED STEPS 1;2 AND 3.;[03] VSDR SWAA2022031782209Light · blownEMERGENCY EXIT LIGHT BATTERY PACK M1672 HAS BLOWN THE FUSE RELATED TO PINS 9 AND 10. / [01] REPLACED FUSE AND ISOLATED LIGHT RELATED TO PIN 9 (L1076 LEFT AFT OVERDOOR EXIT SIGN). PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHTS FOUND FUSE TO BE INTACT; SUSPECT ASDR SWAA2022031780517Light · inoperativeFOUND M1672 AND M1673 BATTERY CHARGERS TO BE NOT EFFECTIVE FOR A/C / [01] REMOVED AND REPLACED M1672 AND M1673 BATTERY CHARGERS; PERFORMED A GOOD OPERATIONAL TEST PER AMM 33-51-06-960-806;[02] REMOVED AND REPLACED M1673 AND M1672 BATTERY CHARGERS; PERFORMED A SDR SWAA2022031780518Charger · faultyFOUND M1674 AND M1675 BATTERY CHARGERS TO BE NOT EFFECTIVE FOR A/C / [01] PARTIAL WOORK ACCOMPLISHED FOR STEP 1.;[02] COMPLETED STEPS 3 AND 4.;[03] CORRECTED STEP 2 AND 3 FOR CORRECT REFERENCE.;[04] VERIFIED STEP 2 AND 3 ARE COMPLETE;[05] PARTIAL WORK FOR STEPSDR SWAA2022031784939Charger · faultyFOUND M1674 AND M1675 BATTERY CHARGERS TO BE NOT EFFECTIVE FOR A/C / [01] PARTIAL WOORK ACCOMPLISHED FOR STEP 1.;[02] COMPLETED STEPS 3 AND 4.;[03] CORRECTED STEP 2 AND 3 FOR CORRECT REFERENCE.;[04] VERIFIED STEP 2 AND 3 ARE COMPLETE;[05] PARTIAL WORK FOR STEPSDR SWAA2022031784940Charger · faultyFOUND M1674 AND M1675 BATTERY CHARGERS TO BE NOT EFFECTIVE FOR A/C / [01] PARTIAL WOORK ACCOMPLISHED FOR STEP 1.;[02] COMPLETED STEPS 3 AND 4.;[03] CORRECTED STEP 2 AND 3 FOR CORRECT REFERENCE.;[04] VERIFIED STEP 2 AND 3 ARE COMPLETE;[05] PARTIAL WORK FOR STEPSDR SWAA2022031780519Charger · faultyFOUND M1668 AND M1669 BATTERY CHARGERS TO BE NOT EFFECTIVE FOR A/C / [01] PARTIAL WORK ACCOMPLISHED FOR STEP 1.<BR>COMPLETED STEPS 2;3;4;[02] CORECTION TO STEP 2 AND 3 EDIT REMOVE AND REPLACE TO REMOVED AND REPLACED.;[03] VERIFIED PARTIAL UPDATE STEP 1.<BR>VERSDR SWAA2022031784942Charger · faultyFOUND M1668 AND M1669 BATTERY CHARGERS TO BE NOT EFFECTIVE FOR A/C / [01] PARTIAL WORK ACCOMPLISHED FOR STEP 1.<BR>COMPLETED STEPS 2;3;4;[02] CORECTION TO STEP 2 AND 3 EDIT REMOVE AND REPLACE TO REMOVED AND REPLACED.;[03] VERIFIED PARTIAL UPDATE STEP 1.<BR>VERSDR SWAA2022031767158Tab · brokenFLOOR PANEL 221B HAS BROKEN TAB ON AFT OUTBOARD EDGE / [01] CORRECT PANEL IS NUMBER 221BF NOT 221B.<BR><BR>IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 2; TABLE 2.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR 4.F.<BRSDR SWAA2022031766638Flange · corrodedCORROSION ON BS 259.5 BULKHEAD LOWER FLANGE; LOCATED AT BS 260; LBL 4.5; WL 199.9 / [01] UPDATED STEPS 1 AND 2;[02] STEP 1;2 COMPLETE;[03] PARTIAL UPDATED STEP 3.;[04] VERIFIED AND COMPLETED STEP 3;[05] REPAIRED DAMAGE ON BS 259.5 BULKHEAD LOWER FLANGE; LOCATESDR SWAA2022031767003Intercostal · corrodedCORROSION ON INTERCOSTAL SUPPORT ANGLE AT B.S. 312+4 - 312 + 12 STRINGER 23 LEFT IN MAIN EBAY. / REMOVED DAMAGE AT ALL LOCATIONS BS 312+4 IN AN AREA OF 2.5' X 1'AND BS 312+12' IN AN AREA OF 0.8'X 0.5' PER SRM 51-10-02-0G-0;[03] VERIFIED CORRECTIVE ACTION 2.;[0SDR SWAA2022031766640None · brokenP18 ATTACH CLIP BROKEN BS261 STRINGER 8LT / [01] REMOVED ATTACH CLIP AT BS 261 STRINGER 8LT IAW SRM 51-40-02;[02] STEP 1 COMPLETE;[03] PARTIAL UPDATE STEP 2.;[04] PARTIAL UPDATE STEP 3.;[05] LOCATED AND DRILLED NEW P18 ATTACH CLIP PER SRM 51-40-05 AND DWG#141ASDR SWAA2022031766254Web · crackedRT WING TE ANGLE AT IB END OF TRANSVERSE WEB IS CRACKED WHERE IT ATTACHES TO DEFLECTION CONTROL RIB RT WING TE ANGLE AT O/B END OF TRANSVERSE WEB (CLIP) IS CRACKED WHERE IT ATTACHES TO DEFLECTION CONTROL RIB / [01] CORRECTION TO WRITE UP NAME; RT WING TE ANGLESDR SWAA2022031574070Angle · crackedRT WING TE BULB SEAL SUPPORT ANGLE AT ORSS 273 (WBL 201.9) ABOVE PYLON STRUT FAIRING TIP / [01] REMOVED R/H WING T/E BULB SEAL SUPPORT ANGLE AT ORSS 273 IAW SRM 51-40-02-0G-0.;[02] REPLACED R/H WING T/E BULB SEAL SUPPORT ANGLE AT ORSS 273 IAW SRM 51-40-02-0G-0SDR SWAA2022020766454Seat Track · corrodedCORROSION IN SEAT TRACK WELL BS540-727B RBL45 WL208 ; / [01] VERIFY STEP 1.; [02] VERIFIED STEP 1. REMOVED CORROSION IN SEAT TRACK WELL FROM BS540-685 RBL45 WL208 PER SRM 51-10-02.SDR SWAA2022031766022Support · crackedCRACKED FLOOR SUPPORT BS 270-294 BL 0 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT AT BS 270-294 BL 0 WL 208 AND LOCATED AND DRILLED NEW FLOOR SUPPORT PER SRM 51-40-02 AND SRM 51-40-05. DRW 141A5400. REQUEST OK TO INSTALL.;[02] INSPECTED AND VERIFIED ACTION 1; SDR SWAA2022031766017Support · crackedCRACKED FLOOR SUPPORT BS 312-328 RBL 31 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT AT BS 312-328 RBL 31 WL 208 AND LOCATED AND DRILLED NEW FLOOR SUPPORT PER SRM 51-40-02 AND SRM 51-40-05. DRW 141A5400. REQUEST OK TO INSTALL.;[02] STEP 1 APPLICABILITY STATEMENSDR SWAA2022031766016Stringer Clip · crackedSTRINGER CLIP CRACKED BS294.5 STRINGER 13LT / [01] REMOVED CRACKED CLIP AT BS 294.5 STRINGER 13 LT IAW SRM 51-40-02;[02] FABRICATED NEW CLIP FROM BAC1489-360 7075T6; LOT #1464682-1 PER DWG 141A1311 <BR>REV C 12/11/97;[03] VERIFIED CORRECTIVE ACTION 1 AND 2; OKSDR SWAA000066018Floor Panel · brokenFLOOR PANEL 221B HAS UPPER SURFACE DAMAGE AND TAB IS BROKEN ON AFT OUTBD EDGE / [01] CORRECT PANEL IS 221BF WITH DAMAGE TO UPPER SURFACE AND TAB AT O/B EDGE NOT 221B.<BR>IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND ALL DAMAGE TO BE OSDR SWAA2022031765632Panel · delaminatedPANEL 194CR UPPER EDGEBAND IS DELAMINATED ON OUTER SURFACE (MARKED) / [01] IDENTIFIED PANEL 194CR MATERIAL IAW SRM 53-60-70-0I-1 FIG.2; SHT.1 AND TABLE 2; ITEM 6.<BR><BR>REMOVED FINISH FOR EVALUATION IAW AMM 51-21-11-150-815 PARA. 17. C. AND D.;[02] VISUAL INSSDR SWAA2022031765638None · corrodedCORROSION ON STRINGER CLIP AT AREA AFT OF ACB BS986 S-27L. MARKED. / [01] EVALUATED STRINGER CLIP BS 986 STRINGER 27 L/H LBL 5 WL 183; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVESDR SWAA2022031765636Gusset · corrodedCORROSION ON GUSSET AT AREA AFT OF ACB BS984 S-24R. / [01] EVALUATED GUSSET BS 984 STRINGER 24 R/H WL 187 RBL 11; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1;[03] REMOVESDR SWAA2022031765155Attach Angle · crackedINTERCOSTAL ATTACH ANGLE IS CRACKED AT FWD CARGO BAY BS400 AFT SIDE RBL25. / [01] CRACKED ANGLE FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1;[03] REMOVED DAMAGED ATTACH ANGLE;LOCATED AND DRILLED NEW ATTACH SDR SWAA2022031765148Attach Angle · crackedINTERCOSTAL ATTACH ANGLE IS CRACKED AT FWD CARGO BAY BS400 AFT SIDE LBL25. / [01] CRACKED ANGLE FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1;[03] REMOVED DAMAGED ATTACH ANGLE;LOCATED AND DRILLED NEW ATTACH SDR SWAA2022031765150Attach Angle · crackedINTERCOSTAL ATTACH ANGLE IS CRACKED AT FWD CARGO BAY BS500B AFT SIDE LBL25. / [01] CRACKED ANGLE FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1;[03] REMOVED DAMAGED ATTACH ANGLE;LOCATED AND DRILLED NEW ATTACHSDR SWAA2022031765156Attach Angle · crackedINTERCOSTAL ATTACH ANGLE IS CRACKED AT FWD CARGO BAY BS500C FWD SIDE RBL25. / [01] CRACKED ANGLE FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1;[03] CLEANED ATTACH ANGLE AT BS 500C FWD SIDE RBL 25 AND AFTER FSDR SWAA2022031765628Stringer · crackedCRACKED STRINGER AT AREA AFT OF FCB BS536 S-26L WL153. MARKED / [01] DAMAGED REMOVED AT BS 500D +10' - 540 S-26L AND PERFORMED VISUAL INSPECTION IAW SRM 53-00-03-2R-1 REP.1 PAR 4(A-B1);[02] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1;[03] VERIFIED CORRECTIVE ASDR SWAA2022031765627Stringer · crackedCRACKED STRINGER AT AREA AFT OF FCB BS536 S-26R WL153. MARKED / [01] DAMAGED REMOVED AT BS 500D +10' - 540 S-26R AND PERFORMED VISUAL INSPECTION IAW SRM 53-00-03-2R-1 REP.1 PAR 4(A-B1);[02] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1;[03] VERIFIED CORRECTIVE ASDR SWAA2022031765631Stringer · crackedCRACKED STRINGER AT AREA AFT OF FCB BS536 S-25R WL155. MARKED / [01] DAMAGED REMOVED AT BS 500D +10' - 540 S-25R AND PERFORMED VISUAL INSPECTION IAW SRM 53-00-03-2R-1 REP.1 PAR 4(A-B1);[02] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1;[03] VERIFIED CORRECTIVE A
Back to N7882B, cancelled Feb 17, 2025