FAA incident reports · 4
FAA accident and incident reports matched to this aircraft by N830EX and the event date: up to this one’s cancellation.
Incident 19990722014989INormal Cruise · Pittsburgh, PAThe pilot stated that on August 22, 1999, at 1320 local time, allegheny ailrines (pcaa) flight 3911 encountered unexpected turbulence. The flight was enroute from harrisburg, PA (MDT) to Pittsburgh., PA (pit) at 14,000 feet and approximately 12 miles east of…Incident 19960303007009IFinal Approach · Binghamton, NYNarrative: on March 3, 1996, at 1450 EST, a Dehavilland dhc 8-102, N830EX, flight 3574, operated by allegheny commuter airlines, during approach to runway 28 at edward a. Link airfield, experienced an unsafe right main landing indication. Aircraft landed and…Incident 19950701020799ITo Init Climb(1st Pwr Reduct) · Syracuse, NYUnsafe gear light on climbout. Returned. Uplock proximity sensor out of adjustment.Incident 19950523014649INormal Cruise · Albany, NYHydraulic system failure en route. Used backup system. NR1 system returned to normal on ramp. Indicator a suspect.
Service difficulty reports · 31
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR PCAA0312148Engine · overservicedFLIGHT 3760, DIVERTED DUE TO SEVERAL PASSENGERS DETECTED A BURNING ODOR THROUGHOUT CABIN, PILOT ALSO DETECTED BURNING ODOR COMING FROM ALL VENT UPON OPENING COCKPIT DOOR. EMERGENCY WAS DECLARED AND THE PASSENGER COMPARTMENT WAS PREPPED FOR SAME. AIRCRAFT LANSDR PCAA0301019Connector · disconnectedDURING ROUTINE MAINTENANCE VISIT 3 EMERGENCY FLOOR LIGHTS WERE FOUND INOPERATIVE AT ROW 5. AFTER REMOVING CENTER FLOORBOARD, WIRING FOR LIGHTS FOUND TO BE UNPLUGGED. CONNECTOR RECONNECTED. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR PCAA0204047Frame · crackedDURING ROUTINE MAINTENANCE VISIT A CRACK WAS DISCOVERED IN AFT EQUIPMENT BAY (APU AREA) AT FRAME NR 4 RIGHT SIDE. CRACK WAS REPAIRED IN NR 4 FRAME IN ACCORDANCE WITH DEHAVILLAND REPAIR DRAWING. REPAIR FABRICATED AND INSTALLED PER RD8-55-199. EDDY CURRENT IN
See all 31 reports